PARAGON CUTTER ERROR CODE INFORMATION

ErrorIDCode ErrorLevel ErrorMessage ErrorCause ErrorRemedy


Not caused by anything. Used as the default value for the
0 5 No Error none
error enumeration to indicate there is no error.
An unknown error number has been posted. This is due to a
1 1 An unknown error number {0} has been posted. Report as a software bug.
software bug.
Go to the Diagnostics, EtherCat Nodes screen and
observe the first node that is not connected. Make
A device has crashed, lost power, experienced a hardware sure the EtherCat cables are seated fully in their
2 1 Device {0} : {1} is not connected.
failure, or lost network connection. connectors, particularly at that first node. Restart
the Paragon software first, if problem still persists
then restart the cutter.
Use diagnostics to ensure the motor, encoder, and
3 5 Axis {0} failed to home. A failure prevented an axis from homing. limit switches are functioning properly. Repair as
need. Retry homing sequence.
Use diagnostics to ensure the tool actuator and
4 3 Position of tool {0} failed to change. The tool actuator or position sensor(s) failed. position sensors are functioning properly. Repair as
needed and resume interrupted function.

Use diagnostics to ensure the tool actuator and


5 3 Position of tool {0} is unknown. The tool position sensor(s) failed. position sensors are functioning properly. Repair as
needed and resume interrupted function.

Use diagnostics to ensure the tool actuator and


Low or no power to motor/encoder, encoder failure, motor
6 1 Axis {0} experienced a following error. position sensors are functioning properly. Repair as
failure, or amplifier failure.
needed and resume interrupted function.

Visually inspect chaff vacuum path and remove any


No power to or failure of chaff vacuum generator. Clogged material clogging the path. Use diagnostics to
7 1 Chaff removal device {0} reported a vacuum error.
vacuum pathway. ensure the chaff vacuum is functioning. Repair as
needed and resume interrupted function.

Vacuum level is below the minimum required, for the Ensure the table is sufficiently sealed to maintain
configured time duration, to move the conveyor when the the required vacuum level. Use diagnostics to
8 5 Table vacuum too low to move conveyor.
vacuum system is on. Table is not sufficiently sealed, ensure the vacuum system is functioning properly.
vacuum is off or vacuum is malfunctioning. Repair as needed and resume interrupted function.

Vacuum level is below the minimum required, for the Ensure the table is sufficiently sealed to maintain
configured time duration, to cut material when the vacuum the required vacuum level. Use diagnostics to
9 3 Table vacuum too low cut.
system is on. Table is not sufficiently sealed, vacuum is off or ensure the vacuum system is functioning properly.
vacuum is malfunctioning. Repair as needed and resume interrupted function.
Vacuum level is above the maximum allowed, for the Use diagnostics to ensure the vacuum system is
10 5 Table vacuum too high to convey. configured time duration, to move the conveyor when the functioning properly. Repair as needed and resume
vacuum system is on. interrupted function.
Use diagnostics to ensure proper operation of the
Knife Intelligence sesnsor. Verify straightness of
11 1 Knife Intelligence Sensor Failure on {0}. Due to broken wire(s), sensor failure, or bent knife.
knife. Repair as needed and resume interrupted
function.
Use diagnostics to ensure proper operation of the
Knife Intelligence sesnsor. Verify straightness of
12 1 Knife Intelligence Calibration Failure. Due to broken wire(s), sensor failure, or bent knife.
knife. Repair as needed and resume interrupted
function.
The head was commanded to move outside of the allowed
Commanded position for axis {0} is outside the range for the origin tool as a result of checking fabric width. The job may still process OK, try resuming cutting.
13 2
valid range. This may occur on jobs that are very close to the max width Reduce job width if problem persists.
of the table.
Controller has determined that two beams would have
Collision between beam {0} and beam {1}
14 1 collided if the system was not stopped. This is considered to Report as a software bug.
imminent.
be a flaw in planning.
Some conveyors have poor position control. It is possible for
Jog the conveyor in reverse until the parts are
the conveyor to over or under shoot the desired position. If
reachable by their assigned tools. When moving the
15 3 Conveyor moved too far. the conveyor moved too far one or more process items
conveyor backwards be careful to move conveyor
could be positioned outside their assigned work areas and
forward again to eliminate slack.
cannot be processed.
The operator is required to calibrate (also know as null)
16 5 Knife Intelligence not calibrated. Perform the knife intelligence calibration.
knife intelligence before cutting begins.
Attempt to move an axis to a position before it has been
17 5 Axis {0} is not homed. Initiate the homing sequence.
homed.
A tool was expected to be on and is not. This could be
Use diagnostics to ensure the tool motor is
because the operator did not turn the tool on or a hardware
18 5 Tool {0} is off. functioning properly. Repair as needed and resume
failure is preventing the tool motor from running. Examples
interrupted function.
of such tools are recipricating knives and spinning drills.
19 4 Table vacuum off. The table vacuum must be on in automatic mode. Turn on the vacuum.
Use diagnostics to ensure proper operation of the
The tool pressure failed to reach the commanded pressure
20 3 Failed to set pressure for tool {0}. tool pressure system and sensor. Repair as needed
within the configured timeout.
and resume interrupted function.
21 1 Drive Faulted {0}. FSR: {1} ESR: {2} The drive detected a fault. Re-enable Servos.
22 3 Drive {0} did not enable - Error Register Value 0x{1} The drive failed to enable. Re-enable Servos.
23 5 Can not trim cut with selected tool {0}. A tool that can not cut was selected to trim cut. Selected a tool that has cutting capabilities.
24 5 Trim cut failed to complete. Trim cut failed. Retry trim cut.
Cut engine {0} failed to pause within the expected
25 1 The cut engine failed to pause. Report as a software bug.
amount of time.
Some conveyors have poor position control. It is possible for
the conveyor to over or under shoot the desired position. If
Jog the conveyor forward until the parts are
26 3 Conveyor stopped too soon. the conveyor did not move far enough one or more process
reachable by their assigned tools.
items could be positioned outside their assigned work areas
and cannot be processed.
27 1 Cannot find tool {0}. A tool with the specified device Id can not be found. Restart the system.
The conveyor has failed to move or the operator paused Manually move the conveyor so that the process
28 3 Process item not in its assigned work area.
cutting, moved the conveyor, and resumed cutting. item can be reached by its assigned tool.
AdsSyncWriteReqEx Failed in SetMasterState with
29 1 Error setting Master EtherCAT state. TBD
error code {0}.
AdsSyncWriteReqEx Failed in SetSlaveState with
30 1 Error setting Slave EtherCAT state. TBD
error code {0}.
31 1 Equipment Factory cannot create device "{0}" Error creating software representation of a device. TBD
32 1 Device Node Factory cannot create device "{0}" Error creating software representation of a device. TBD
A Channel does not exist for Connection {0}.
33 1 TBD TBD
Exception: {1}: {2}.
34 1 Cant find channel {0} TBD TBD
35 5 Command has no completion handler pointer. TBD TBD
36 5 Command has no execution handler. TBD TBD
37 5 Command object is null. TBD TBD
Exception occurred while configuring
38 5 TBD TBD
ControllerComponent: {0} at {1}
39 5 Open failed accepted connection %s disposed. TBD TBD
40 5 {0} TBD TBD
41 5 {0}: {1} TBD TBD
Exception occurred while configuring
42 5 TBD TBD
ConnectionManager: {0} at {1}
43 5 The control panel called {0} is not connected. TBD TBD
44 5 Dequeue() returned {0}. TBD TBD
45 5 Error Occurred sending SDO List for {0} TBD TBD
Error Occurred sending Velocity Loop Output Filter
46 5 TBD TBD
{0}
47 5 Factory not found for the following object {0}. TBD TBD
Failed to convert enum type {0}, value {1} to a
48 5 TBD TBD
string.
49 5 Handshake error. Sent {0}. Received {1} TBD TBD
Invalid Equipment Model configuration file.
50 1 TBD TBD
Abandoning load.
Invalid Device Node configuration file. Abandoning
51 1 TBD TBD
load.
Invalid TwinCat configuration file. Missing Node
52 1 TBD TBD
{0}. Abandoning load.
53 1 Configuration node {0} is missing. TBD TBD
54 5 Configuration value {0} for node {1} is missing. TBD TBD
Device {0} was not found in the parameter registry.
55 5 TBD TBD
All IParameter classes must be registered.

56 5 Publisher Not Found For GetValue Request For {0} TBD TBD
57 5 Read Failure. {0}: {1} TBD TBD
58 5 Exception occurred in read thread: {0}: {1}. TBD TBD
Failed to find relative nest for setting a relative
59 5 TBD TBD
origin.
60 5 Reply received does not match pending command. TBD TBD
61 5 Read Error {0} TBD TBD
62 5 SDO Write Error {0} - SDO 0x{1} {2} TBD TBD
Device "{0}" does not recognize the
63 5 TBD TBD
parameter"{1}".
Maximum x for tool {0} exceeds maximum table x.
64 5 TBD TBD
({1} - {2} is greater than {3})
Maximum y for tool {0} exceeds maximum table y.
65 5 TBD TBD
({1} - {2} is greater than {3})
Minimum x for tool {0} exceeds minimum table x.
66 5 TBD TBD
({1} - {2} is less than {3})
Minimum y for tool {0} exceeds minimum table y.
67 5 TBD TBD
({1} - {2} is less than {3})
68 5 Unable to find a tool associated with device id {0}. TBD TBD

69 5 Unable to find a head associated with device id {0}. TBD TBD


Command %s execution threw an exception: {0} at
70 5 TBD TBD
{1}.
71 2 Unhandled Exception {0} at {1} An internal software error has occurred Report as a software bug.
72 5 Unpack failure deserializing {0} object of {1}. TBD TBD
73 5 Write Failure. {0}: {1} TBD TBD
The Process Managers tool configuration does not match
74 5 Invalid tool configuration. Shutdown the system and re-install software.
the equipment model.
Configuration for the controller named {0} does
Process Manager has a tool model configuration that does
75 5 not match the tool model. Details of the mismatch Shutdown the system and re-install software.
not match one of the controllers equipment model.
follow: {1}.
The status monitor has detected an error The status monitor has detected a value that exceeded its Switch to the status monitor for detailed
76 3
condition. error threshold. information.
A controller has crashed, lost power, experienced a Ensure controller is running and physically
77 1 Lost connection to controller {0}.
hardware failure, or lost network connection. connected.
The software has encountered an unrecoverable
78 1 An unhandled exception occurred in the workflow. Unhandled exception in workflow error. Press OK to cancel all jobs in progress and
restart the current workflow.
A control panel has crashed, lost power, experienced a Ensure control panel is running and physically
79 1 Lost connection to control panel {0}.
hardware failure, or lost network connection. connected.
80 1 Table vacuum is set to the wrong level. Software failure. Report as a software bug.
Vacuum level is below the minimum required, for the Ensure the table is sufficiently sealed to maintain
configured time duration, for the current vacuum level. the required vacuum level. Use diagnostics to
81 3 Table vacuum is too low.
Table is not sufficiently sealed, vacuum is off or vacuum is ensure the vacuum system is functioning properly.
malfunctioning. Repair as needed and resume interrupted function.
Use diagnostics to ensure the vacuum system is
Vacuum level is above the maximum allowed, for the
82 3 Table vacuum too high. functioning properly. Repair as needed and resume
configured time duration, for the current vacuum level.
interrupted function.
To ensure jobs are deleted when complete or
The job file could not be deleted due to one or more of the
canceled only queue jobs that can be deleted by
83 3 Unable to delete job file. ({0}: {1}) following: insufficient access rights, file is read only, file is
the currently logged in user. Alternatively, disable
open, file not found.
the option to delete job files.
Ensure the table is sufficiently sealed to maintain
the required vacuum level. One way is to cover
The vacuum level did not change within the operator
open areas and cut lines with additional pieces of
Table vacuum failed to change in the required defined time. Table may not be sufficiently sealed, the
84 3 plastic. Increase the vacuum timeout if it is too
time. timeout may be too small, vacuum may be off or
short. Use diagnostics to ensure the vacuum system
malfunctioning.
is functioning properly. Repair as needed and
resume interrupted function.
Unhandled Exception in Process Manager: ({0} :
85 5 TBD TBD
{1})
86 1 Invalid configuration file \{0}\ TBD TBD
Error occurred trying to turn off startup
87 5 TBD TBD
performance timer.
88 5 ComponentCommandsClient error: {0} TBD TBD
Reconnect number {0} for component {1}
89 5 TBD TBD
exceeded the maximum of {2}.
Exception occurred on component {0}, exception:
90 5 TBD TBD
{1}
Version mismatch: Component {0}, Current version
91 5 TBD TBD
{1}, Expected version {2}
Command raised an exception: component {0},
92 5 TBD TBD
exception {1}
Configuration value {0} not found for
93 5 TBD TBD
ComponentService.
94 5 Configuration Node {0} is missing. TBD TBD
95 5 Configuration Parameter {0} is missing. TBD TBD
Attempted to update an error recovery session
96 5 TBD TBD
with id {0} but none was found.
Attempted to begin a recovery session while a
97 5 previous recovery session was in progress. Only TBD TBD
one session may be active at a time.
98 5 Central Host Proxy Not Set. TBD TBD
Cannot register. Either IPublisher or
99 5 TBD TBD
PublisherAddress is null.
Cannot have Discrete subscription to non-discrete
100 5 TBD TBD
{0} publisher.
Publisher With Address {0} Exists. Cannot
101 5 TBD TBD
Reregister.
102 5 Missing IRemoteSubscribersAgent For {0}. TBD TBD
103 5 Get Publisher Failed. PublisherAddress is null. TBD TBD
Cannot subscribe. Either ISubscription or
104 5 TBD TBD
ISubscription.PublisherAddress is null.
105 5 Couldnt load queue history file: {0} TBD TBD
Cant copy QueueService history file \"{0}\" to
106 5 TBD TBD
\"{1}\": {2}
107 5 Cant delete QueueService history file \"{0}\": {1} TBD TBD
108 5 Exception occurred during Enqueue: \"{0}\" TBD TBD
109 5 Exception in DigitizeImage {0} TBD TBD
110 5 File Error: {0}, Exception: {1} TBD TBD
111 5 No points. Cant create job {0} TBD TBD
Register Publication Failed. PublisherAddress is
112 5 TBD TBD
null.
113 5 Cannot use color with a grayscale scanner. TBD TBD
114 5 Cannot find free boards TBD TBD
115 5 Cannot load dummyeval.dll TBD TBD
116 5 InitScanner Exception: {0} TBD TBD
117 5 Cannot set output channel {0} TBD TBD
118 5 Slink failed to open error TBD TBD
119 5 Slink error on camera: {0} TBD TBD
120 5 Reference values file cannot be found at: {0} TBD TBD
121 5 Overlap file could not be found at location: {0} TBD TBD
122 5 Settings.ini file could not be found at location: {0} TBD TBD
Empty line in overlap file! Please recalibrate the
123 5 TBD TBD
overlap.
Overlap in the overlap file is not valid for this
124 5 TBD TBD
scanner model.
125 5 Acquire Exception: {0} TBD TBD
Invalid Configuration Node Value: File: {0}, Name:
126 5 TBD TBD
{1}, Value: {2}, Location: {3}.
127 5 SimplexChannel: No connection. TBD TBD
128 5 {0} Controller Faulted {1} TBD TBD
ExecutionEngineFsm::GetConveyorPaused not
129 5 TBD TBD
Implemented yet.
Timeout occurred while requesting the current
130 5 TBD TBD
material. Another attempt will be made.
131 1 NurbsPlusPlusWrapper library is missing. TBD TBD
ProcessItem (Id={0}, DeviceId={1},
ToolHolderDeviceId={2}) too big for work area.
Nest (JobGuid={3}, Id={4}, origin=(x={5}, y={6})).
132 2 TBD TBD
itemBoundary=(x={7}, y={8}, width={9},
height={10}). workArea=(x={11}, y={12},
width={13}, height={14}).
Planning Failed: Attempted to populate start
constraints, but a process item {2} in nest {1} in job
133 2 TBD TBD
{0} is too wide for work area of tool {3} in holder
{4}.
134 5 Removing Client Due To Exception: {0} TBD TBD
135 5 NestPosition received from controller was null. TBD TBD
ControlParameter {0} is missing or not in double
136 5 TBD TBD
precision format. Using {1} as {2}
137 5 Cannot enqueue job will null database id. TBD TBD
138 5 Cannot enqueue null job file TBD TBD
Error occurred processing the run time parameters
139 5 TBD TBD
for job {0}, message: {1}
Error occurred processing the run time parameters
140 5 TBD TBD
for job {0}.
141 5 Error occurred reading the job file {0}. TBD TBD
142 5 Could not open file: {0} TBD TBD
143 5 Could not delete file: {0}
144 1 Cant find WorkflowType in Components.config TBD TBD
Cant find WorkflowFolderLocation in
145 1 TBD TBD
Components.config
A new set of materials was received, but an error
146 5 TBD TBD
occured: {0}
A new current material value was received, but an
147 5 TBD TBD
error occured: {0}
A create material event was received, but an error
148 5 TBD TBD
occured: {0}
A delete material event was received, but an error
149 5 TBD TBD
occured: {0}
150 5 Error loading app.config file: {0} TBD TBD
Load ProcessParameter Groups threw exception:
151 5 TBD TBD
{0}
152 5 Add ProcessParameter Group threw exception: {0} TBD TBD
Remove ProcessParameter Group threw exception:
153 5 TBD TBD
{0}
154 5 Load vision preferences threw exception: {0} TBD TBD
A bad parameter was provided, cannot change tool
155 5 TBD TBD
without a tool holder.
A bad parameter was provided, cannot change tool
156 5 TBD TBD
without a tool.
A bad parameter was provided, cannot locate the
157 5 TBD TBD
specified tool holder
A bad parameter was provided, cannot locate the
158 5 TBD TBD
specified tool.
Timeout occurred while attempting to change a
159 5 TBD TBD
tool.
160 5 A connection is not available. Try again later. TBD TBD
Timeout occurred while attempting to remove a
161 5 TBD TBD
tool from a tool holder: {0}
A bad parameter was provided, cannot update tool
162 5 TBD TBD
wear without a tool.
A bad parameter was provided, cannot locate the
163 5 TBD TBD
specified Tool.
Timeout occurred while attempting to update the
164 5 TBD TBD
tool wear for a tool.
A bad parameter was provided, cannot move
165 5 TBD TBD
ToolHolder to the tool change position.
A bad parameter was provided, cannot locate the
166 5 TBD TBD
specified tool holder.
Timeout occurred while attempting to move a tool
167 5 TBD TBD
holder to the tool change position.
168 5 Register client exception: {0}. TBD TBD
169 5 Client Removed. {0} TBD TBD
Stopping EventQueue In
170 5 StatusDistributorCallbackHandler Due To TBD TBD
Exception: {0}
Cant get remote configuration file {0} from
171 5
controller {1}: {2}
An exception occurred while processing a Log On:
172 5 TBD TBD
{0}
An exception occurred while processing a Log Off:
173 5 TBD TBD
{0}
An exception occurred while processing a Shift
174 5 TBD TBD
Start: {0}
An exception occurred while processing a Shift
175 5 TBD TBD
End: {0}
Unable to fetch global parameters from database:
176 5 TBD TBD
{0}
178 5 Unable to determine available workflows: {0} TBD TBD
Validation failed: Requested workflow does not
179 5 TBD TBD
exist. Workflow change requested from {0} to {1}.
180 5 Unable to load workflow: {0} Exception: {1} TBD TBD
181 5 Unhandled exception on a workflow service: {0} TBD TBD
182 5 File is in use: {0}, Exception: {1} TBD TBD
183 5 {0} Interal Limit Active {1} TBD TBD
184 5 Could not create nurbs++ curve. TBD TBD
185 5 StreamOperation Failed: {0} TBD TBD
186 1 Cannot find Workflow file {0} TBD TBD
Timeout occurred attempting to reach vacuum
187 3 TBD TBD
level {0}.
188 5 Exception: Communication object aborted {0} TBD TBD
189 5 Exception: Communication object faulted {0} TBD TBD
190 5 Exception:TimeoutException {0} TBD TBD
191 5 Exception:ObjectDisposedException {0} TBD TBD
192 5 Communication Exception {0} TBD TBD
193 5 Exception during BeginFetchReportFields: \"{0}\". TBD TBD
Exception during begin fetch remote side
194 5 TBD TBD
operation state \"{0}\"
195 5 Configuration Parameter {0} exists, but is incorrect. TBD TBD
Configuration Parameter {0} {1} may exist, but it
196 5 conflicts with a already defined {1} Parameter of a TBD TBD
different node.
Connecting to database table {0} with ID {1}, threw
197 5 TBD TBD
exception {2}.
Connecting to database table {0} to persist {1}
198 5 TBD TBD
failed.
Configuration Parameter {0} is incompatible with
199 5 TBD TBD
type {1}
Configuration Parameter {0} exists, but is incorrect,
200 5 TBD TBD
Using default value {1}.
StatusMonitor: Opening file {0} to persist to failed:
201 5 TBD TBD
{1}
202 5 Subscription timed out: {0} TBD TBD
203 5 Subscription objected already disposed: {0} TBD TBD
204 5 Remote Vision Server threw an exception: {0} TBD TBD
205 1 Configuration file {0} not found: {1} TBD TBD
206 5 Cannot set default parameters on startup. TBD TBD
207 5 Cannot find default parameters to copy. TBD TBD
208 5 Process Image exception: {0}. TBD TBD
209 5 Vision Service link was not found. TBD TBD
210 5 Vision Service program was not found: {0} TBD TBD
211 5 Vision Service was not started. TBD TBD
212 5 Unregister client exception: {0}. TBD TBD
Could not connect to the database. Database not
214 1 TBD TBD
found.
215 5 The specified parameter cannot be null. TBD TBD
216 5 Database error occured when submitting data. TBD TBD
217 5 Vision Group was not found: {0} {1} in database. TBD TBD
218 5 Vision Group already exists for {0} {1} TBD TBD
219 5 Parameter {0} format error: {1} TBD TBD
Unable to refresh control parameters - error
220 5 TBD TBD
fetching global parameters from database: {0}
Connecting to database table {0} with ID {1}, threw
221 5 TBD TBD
exception {2}.
222 5 No NestProcessArea defined in ToolModel.config TBD TBD

223 5 No EffectiveWorkZone defined in ToolModel.config TBD


224 5 No TakeOffZone defined in ToolModel.config TBD TBD
225 5 No Table Zones were defined in ToolModel.config TBD TBD

226 1 Tool {0}.{1} is not registered in the Tool Factory. TBD TBD
227 5 Serialization error {0} for command {1} TBD TBD
228 5 No factory registered for command {0} TBD TBD
229 5 No channel defined for this connection: {0} TBD TBD
230 5 Unable to identify connection: {0} TBD TBD
231 5 SocketException: {0} TBD TBD
232 1 Adapter TypeName Not Recognized: {0}. TBD TBD
Cant Subscribe to State Model because service isnt
233 5 TBD TBD
opened.
Unable to correctly assign the device id of Control
234 5 TBD TBD
Parameter [Key:{0}, Value:{1}]
Unable to correctly assign the device id of Control
235 5 TBD TBD
Parameter [Key:{0}, Value:{1}] : {2}
Unable to correctly assign the key of Control
236 5 TBD TBD
Parameter [Key:{0}, Value:{1}]
Unable to correctly assign the key of Control
237 5 TBD TBD
Parameter [Key:{0}, Value:{1}] : {2}
A save was requested for queue item with GUID
238 5 TBD TBD
{0}, but the filename was bad or missing. {1}
239 1 Invalid tool configuration file: {0} TBD TBD
The system is attempting to open a job file that is no longer Open the "Jobs Queue" and inspect the "In
240 1 Unable to locate file: {0} available. The job may have been previously canceled or Progress" queue. Remove or Cancel the job
removed from the Jobs Queue. matching the reported filename.
Unable to locate a tool while sending tool holder
241 5 TBD TBD
information to the controller: {0}
242 5 {0} Path not found. TBD TBD
Unable to fetch current material from database:
243 5 TBD TBD
{0}
Unknown ProcessItem, cannot generate a time
244 1 TBD TBD
estimate for type {0}.
The constant rate conveyor velocity is greater than
245 1 TBD TBD
the maximum velocity for the conveyor.
The specified path plan sequence places a process
246 2 TBD TBD
item beyond the work area.
Timeout occurred attempting to reach idle
247 5 TBD TBD
vacuum.
StatusMonitor: Error threshold triggered on {0}
248 3 TBD TBD
with value {1} exceeding {2} limit {3} : {4}
249 1 Unhandled exception in workflow: {0} An internal software error has occurred Report as a software bug.
250 1 Unknown Error in Biting Workflow. TBD TBD
Timeout occurred while requesting a tool model.
251 5 TBD TBD
Another attempt will be made.
252 5 Unable to connect to database. TBD TBD
253 5 An error ocurred while executing your query. TBD TBD
254 5 The specified global parameter cannot be null. TBD TBD
A global parameter cannot be created without a
255 5 TBD TBD
valid Name field.
A global parameter cannot be created without a
256 5 TBD TBD
valid Value field.
A material parameter already exists with the
257 5 TBD TBD
name: {0}.
An error occurred while submitting to database.
258 5 TBD TBD
The changes have not been made: {0} : {1}
A global parameter cannot be updated without a
259 5 TBD TBD
valid Name field.
A global parameter cannot be updated without a
260 5 TBD TBD
valid Value field.
261 5 The specified global parameter does not exist. TBD TBD
A global parameter already exists with the name:
262 5 TBD TBD
{0}.
263 5 The specified material cannot be null. TBD TBD
A material cannot be created without a valid Name
264 5 TBD TBD
field.
265 5 A material already exists with the name: {0}. TBD TBD
A material cannot be updated without a valid
266 5 TBD TBD
Name field.
267 5 The specified material does not exist. TBD TBD
268 5 The specified material parameter cannot be null. TBD TBD
A material parameter cannot be created without a
269 5 TBD TBD
valid Name field.
A material parameter cannot be created without a
270 5 TBD TBD
valid Value field.
A material parameter cannot be created without a
271 5 TBD TBD
valid material id field.
272 5 The specified material could not be found. TBD TBD
A material parameter cannot be updated without a
273 5 TBD TBD
valid Name field.
A material parameter cannot be updated without a
274 5 TBD TBD
valid Value field.
A material parameter cannot be updated without a
275 5 TBD TBD
valid material id field.
276 5 The specified material parameter does not exist. TBD TBD
277 5 The specified override cannot be null. TBD TBD
An override cannot be created without an
278 5 TBD TBD
associated Control Parameter.
An override already exists for name {0} on this
279 5 TBD TBD
material.
An override cannot be updated without a valid id
280 5 TBD TBD
field.
281 5 The specified override does not exist. TBD TBD
The control parameter for the specified override
282 5 TBD TBD
does not exist.
An override cannot be deleted without a valid id
283 5 TBD TBD
field.
Database does not exist. Cannot update job
284 1 TBD TBD
instance.
Database does not exist. Cannot retrieve job
285 1 TBD TBD
instances.
Database does not exist. Cannot clone job
286 1 TBD TBD
instance.
Database does not exist. Cannot delete job
287 1 TBD TBD
instance.
288 5 Failed to clone a job instance. Exception: {0}. TBD TBD
289 5 Failed to delete a job instance. Exception: {0}. TBD TBD
290 5 Failed to update a job instance. Exception: {0}. TBD TBD
291 5 Unable to configure Tools, null tools parameter. TBD TBD
Unable to configure ToolHolders, null toolholders
292 5 TBD TBD
parameter.
294 5 The tool type cannot be null. TBD TBD
295 5 The tool name cannot be null. TBD TBD
296 5 Tool wear cannot be less than zero. TBD TBD
This tool name and type combination already
297 5 TBD TBD
exists in the database. Tool: {0}.{1}.
298 5 Unable to locate the specified tool in the database. TBD TBD
299 5 Cannot change a tool without a tool holder. TBD TBD
Tool change not reflected in the database. Unable
300 5 to find installed tool in the database. ToolHolder: TBD TBD
{0}.{1}, Tool: {2}.{3}.
Unable to locate the specified tool in database, the
301 5 TBD TBD
id field is missing.
Tool change not reflected in the database. Unable
302 5 to find tool holder in the database. ToolHolder: TBD TBD
{0}.{1}.
303 5 Cannot remove a tool without a tool holder. TBD TBD
Tool removal not reflected in the database. Unable
304 5 to find tool holder in the database. ToolHolder: TBD TBD
{0}.{1}.
305 5 Job instance information cannot be null. TBD TBD
306 5 Tool holder mapping cannot be null. TBD TBD
307 5 Job instance database id cannot be null or empty. TBD TBD
A job instance does not exist for the specified
308 5 TBD TBD
database id.
ToolHolder Mapping - unable to locate a tool
309 5 TBD TBD
within the tool model.
Unable to configure ToolHolder: {0}, a configured
310 5 tool does not exist in the ToolModel with a TBD TBD
matching id.
Unable to parse string {0}, using stored value of {1}
311 5 TBD TBD
seconds.
Calibration Factory cannot create calibration Error creating software representation of a calibration
312 1 TBD
strategy "{0}" strategy.
Invalid Calibration configuration file. Abandoning
313 1 TBD TBD
load.
314 4 The knife enable switch on {0} is not on. The knife enable switch is off. Turn the knife enable switch on.
315 3 The knife drive amplifier on {0} is disabled. The knife drive is disabled. Disable and re-enable servos.
The knife drive amplifier on {0} is not at the
316 3 The knife motor may be damaged. Check the knife motor.
required velocity.
Exception during begin fetch remote side
317 5 TBD TBD
operation state \"{0}\"
Database does not exist. Cannot retrieve process
318 1 TBD TBD
item.
Database does not exist. Cannot delete process
319 5 TBD TBD
item.
320 5 Failed to delete a process item. Exception: {0}. TBD TBD
321 5 Failed to update a process item. Exception: {0}. TBD TBD
Database does not exist. Cannot update active
322 5 TBD TBD
nest.
Database does not exist. Cannot retrieve active
323 5 TBD TBD
nest.
324 1 Database does not exist. Cannot delete active nest. TBD TBD
325 1 Failed to delete a active nest. Exception: {0}. TBD TBD
326 5 Failed to update a active nest. Exception: {0}. TBD TBD
Database does not exist. Cannot update process
327 5 TBD TBD
item.
328 5 Job instance Id or nest id cannot be empty or null. TBD TBD

329 5 Job instance Id or nest id cannot be empty or null. TBD TBD


It is possible that the belt is slipping and not reaching Lower vacuum and restart, or check conveyor belt
330 3 Conveyor move did not complete in expected time
position in the expected time tension.
The servo amplifiers were reprogrammed which The servo amplifiers were reprogrammed which requires a
331 1 Cycle the system power.
requires a power cycle of the machine power cycle of the machine
Failed to communicate with printer, check printer
332 3 Printer has an internal error or is off TBD
before continuing.
333 5 Error no take-on zone defined. unknown unknown
334 5 Error no post cutting area defined. unknown unknown
The Control Parameter Id {0} was not found when
335 5 internal database data error Shutdown the system and re-install software.
defining a material override.
Material Selector {0} not found when defining a
336 5 internal database data error Shutdown the system and re-install software.
material override.
The Controller received a bad check sum from the A communication error occurred internally between the Cycle Power. If the error persists, check voltages
337 1
PIC on the I/O board {0} Copley Amplifier and PIC microcontroller on the I/O board. and cabling on the I/O board. Replace I/O board.
The PIC received a bad check sum from the
338 1 Communcation Error Cycle the system power.
Controller on the I/O board {0}
The PIC received a unimplemented multiplexed
339 1 Communcation Error Cycle the system power.
request from the Controller on the I/O board {0}
The auxiliary PLL on the PIC failed on the I/O board
340 1 Communcation Error Cycle the system power.
{0}
Drive Faulted {0}. FSR: {1} ESR: {2}. Main circuit DC
341 1 Main circuit DC voltage is excessively high
voltage is excessively high
Re-enable servos and try to continue. If problem
Drive Faulted {0}. FSR: {1} ESR: {2}. The motor was The servo power supply voltage being supplied to the
persists, check cabling and connectors to the I/O
342 1 operating for several seconds to several tens of amplifier was below the lower limit threshold of the
board, check incoming power and servo power
seconds under a torque largely exceeding ratings. amplifier possibly froma power sag.
supply output level.
Drive Faulted {0}. FSR: {1} ESR: {2}. The motor was
The motor was operating for several seconds to several tens
343 1 operating for several seconds to several tens of
of seconds under a torque largely exceeding ratings.
seconds under a torque largely exceeding ratings.
Drive Faulted {0}. FSR: {1} ESR: {2}. The motor was
The motor was operating continuously under a torque
344 1 operating continuously under a torque largely
largely exceeding ratings.
exceeding ratings.
Drive Faulted {0}. FSR: {1} ESR: {2}. The main circuit
345 1 The main circuit power was frequently turned ON and OFF
power was frequently turned ON and OFF
Drive Faulted {0}. FSR: {1} ESR: {2}. All the power
All the power supplies for the absolute encoder have failed
346 1 supplies for the absolute encoder have failed and
and position data was cleared.
position data was cleared.
Drive Faulted {0}. FSR: {1} ESR: {2}. This warning
This warning occurs before the overload alarms (710h or
occurs before the overload alarms (710h or 720h)
347 1 720h) occur. If the warning is ignored and operation
occur. If the warning is ignored and operation
continues, an overload alarm may occur.
continues, an overload alarm may occur.

Drive Faulted {0}. FSR: {1} ESR: {2}. The EtherCAT


The EtherCAT AL state became not "Operational" while the
348 1 AL state became not Operational while the DS402
DS402 drive state is in "Operation enabled."
drive state is in Operation enabled.

Drive Faulted {0}. FSR: {1} ESR: {2}. The events,


The events, receive process data and sync0, do not
349 1 receive process data and sync0, do not
synchronize. (Failed to receive the process data.)
synchronize. (Failed to receive the process data.)
Drive Faulted {0}. FSR: {1} ESR: {2}.
Communications between the SERVOPACK and the encoder
350 1 Communications between the SERVOPACK and the
is not possible.
encoder is not possible.
Drive Faulted {0}. FSR: {1} ESR: {2}. Position error
351 1 Position error pulses exceeded parameter (Pn520)
pulses exceeded parameter (Pn520)
Drive Faulted {0}. FSR: {1} ESR: {2}. Short circuit The motor wiring may be incorrect or the motor may have Verify that the motor wiring matches the
352 1
detected over heated causing an internal short circuit in the motor. schematic. Check if the motor is hot.
Drive Faulted {0}. FSR: {1} ESR: {2}. Amplifier over
353 1
temperature
Drive Faulted {0}. FSR: {1} ESR: {2}. Motor
354 1
temperature sensor active
355 1 Drive Faulted {0}. FSR: {1} ESR: {2}. Feedback error
Drive Faulted {0}. FSR: {1} ESR: {2}. Motor phasing Verify that the motor wiring matches the
356 1 The motor wiring may be incorrect.
error schematic.
Drive Faulted {0}. FSR: {1} ESR: {2}. Current output Verify that the motor wiring is seated correctly in
357 1 One of the motor wires may be loose or not connected.
limited the connector.
Drive Faulted {0}. FSR: {1} ESR: {2}. Voltage output Verify that the motor wiring is seated correctly in
358 1 One of the motor wires may be loose or not connected.
limited the connector.
Drive Faulted {0}. FSR: {1} ESR: {2}. Positive limit
359 1
switch active
Drive Faulted {0}. FSR: {1} ESR: {2}. Negative limit
360 1
switch active
Drive Faulted {0}. FSR: {1} ESR: {2}. Enable input
361 1
not active
Drive Faulted {0}. FSR: {1} ESR: {2}. Amp is disabled
362 5
by software
Drive Faulted {0}. FSR: {1} ESR: {2}. Trying to stop
363 5
motor
Drive Faulted {0}. FSR: {1} ESR: {2}. Motor brake
364 5
activated
Drive Faulted {0}. FSR: {1} ESR: {2}. Positive
365 1
software limit condition
Drive Faulted {0}. FSR: {1} ESR: {2}. Negative
366 1
software limit condition
Re-enable servos and try to continue. If problem
An excessive amount of following error occurred. This may
persists, reduce cutting speed and/or acceleration,
have been the result of an invalid position generation in the
ensure proper knife sharpening and check for
367 1 Drive Faulted {0}. FSR: {1} ESR: {2}. Tracking error contouring, or excess mechanical loading on the servo
mechanical binding in the axes. If problem is
system due to cutting conditions, or mechanical
repeatable with the same job, report as a software
maintenance is required.
bug.
Drive Faulted {0}. FSR: {1} ESR: {2}. Tracking
368 5
warning
Drive Faulted {0}. FSR: {1} ESR: {2}. Amplifier is
369 1
currently in a reset condition
Drive Faulted {0}. FSR: {1} ESR: {2}. Position has
wrapped. The Position variable cannot increase
370 1 indefinitely. After reaching a certain value the
variable rolls back. This type of counting is called
position wrapping or modulo count.
Drive Faulted {0}. FSR: {1} ESR: {2}. Amplifier fault.
371 5
See the fault latch for more info.
Re-enable servos and try to continue. If problem
An excessive amount of following error occurred. This may
persists, reduce cutting speed and/or acceleration,
Drive Faulted {0}. FSR: {1} ESR: {2}. Position Error have been the result of an invalid position generation in the
ensure proper knife sharpening and check for
372 1 (index 0x60F4, p. 139) is outside Position Tracking contouring, or excess mechanical loading on the servo
mechanical binding in the axes. If problem is
Window (index 0x6067, p. 138). system due to cutting conditions, or mechanical
repeatable with the same job, report as a software
maintenance is required.
bug.
Drive Faulted {0}. FSR: {1} ESR: {2}. Velocity
373 5 window. Set if the absolute velocity error exceeds
the velocity window value.
Drive Faulted {0}. FSR: {1} ESR: {2}. Phase not yet
initialized. If the amplifier is phasing with no Halls,
374 1
this bit is set until the amplifier has initialized its
phase.
Drive Faulted {0}. FSR: {1} ESR: {2}. Command fault.
PWM or other command signal not present. . If
Allow 100% Output option is enabled, by setting
375 1
Bit 3 of Digital Input Command Configuration
(Object 0x2320, p. 121), this fault will not detect a
missing PWM command.

Drive Faulted {0}. FSR: {1} ESR {2}. Overcurrent.


376 1 In Manual In Manual
Output current has exceeded trip level.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Analog input
377 1 In Manual In Manual
AI1 signal has fallen below limit.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Analog input
378 1 In Manual In Manual
AI2 signal has fallen below limit.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Motor
temperature estimation is too high due to
379 1 In Manual In Manual
excessive load, insufficient power, incorrect start-
up data, or exceeding fault limit set by parameter.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Control panel
380 1 selected as active control location for drive has In Manual In Manual
ceased communicating.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Motor ID run is
381 1 In Manual In Manual
not completed successfully.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Motor is
382 1 operating in stall region to to excessive load or In Manual In Manual
insufficient motor power.
Drive Faulted {0}. FSR: {1}. ESR: {2}. An external
383 1 In Manual In Manual
device has faulted.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Drive has
384 1 detected earth (ground) fault in motor or motor In Manual In Manual
cable or an internal short circuit has occurred.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Motor load is
385 1 too low due to eg release mechanism in driven In Manual In Manual
equipment.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Temperature of
the drive exceeds the operating level of the
386 1 In Manual In Manual
thermistor or the thermistor is open or short-
circuited.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Current
387 1 In Manual In Manual
measurement is out of range.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Intermediate
388 1 circuit DC voltage is oscillating due to missing input In Manual In Manual
power line phase or blown fuse.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Motor is
turning faster than 120% of the highest allowed
389 1 speed due to incorrectly set min/max speed, In Manual In Manual
insufficient braking torque, or changes in load
when using torque reference.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Internal
390 1 In Manual In Manual
configuration file error.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Fieldbus
391 1 In Manual In Manual
communication break.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Error reading
392 1 In Manual In Manual
configuration file.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Trip command
393 1 In Manual In Manual
received from fieldbus
Drive Faulted {0}. FSR: {1}. ESR: {2}. Incorrect input
394 1 In Manual In Manual
power and motor cable connection.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Loaded
395 1 In Manual In Manual
software is not compatible.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Drive Control
396 1 In Manual In Manual
board overheated. Fault trip limit is 95C.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Safe Torque Off
input channel 1 has not been de-energized, but
397 1 channel 2 has. Opening contacts on channel 1 In Manual In Manual
might have been damaged or there is a short
circuit.
Drive Faulted {0}. FSR: {1}. ESR: {2}. Safe Torque Off
input channel 2 has not been de-energized, but
398 1 channel 1 has. Opening contacts on channel 2 In Manual In Manual
might have been damaged or there is a short
circuit.
Possible causes are a job is currently in progress, the Do not attempt to change a material while jobs are
399 1 Failed to set the current material to {0}. {1} requested material was not found in the database, there in progress. Ensure the database contains valid
was a failure updating the database. data, if not, regenerate the database.
Ensure that all nodes are connected in the proper
order as diagrammed in the schematic for EtherCat,
The EtherCat Nodes are not connected correctly. and that all wires are properly seated in their
400 1 The EtherCat Nodes are not connected in the proper order.
Node {0} is in the spot of {1} connectors. Then try restarting the Paragon
Software. If problem persists try cycling power to
the cutter.
Go to the Diagnostics, EtherCat Nodes screen to
observe the first node that is not connected. Make
One of the EtherCat nodes is no longer in an operation state sure the EtherCat cables are seated fully in their
401 1 The EtherCat Node {0} is not in operational state.
at startup. connectors, particularly at that first node. Then try
restarting the Paragon software. If the problem
persists try cycling power to the cutter.
Please ensure that all EtherCat wires are properly
seated in their connectors. Then try restarting the
402 1 The EtherCAT bus is not communicating. The EtherCat bus state went to zero.
Paragon software. If the problem persists try cycling
power to the cutter.
Please notify your service technician next time they are on
The ABB {0} VFD has not been updated with the
403 5 site to update the ABB VFDs with their identification
EtherCAT identification number.
numbers.
404 3 The drill drive amplifier on {0} is disabled. The drill drive is disabled. Disable and re-enable servos.
Knife Intelligence Null value of {0} volts is out of
405 2 The null value is outside the proper range. In Manual
the valid range.
Please inspect and replace or fix the knife as
406 1 A broken knife has been detected. The knife has broken.
necessary.
Please check the connections to the knife
Error communicating with the Knife Intelligence There has been a problem with the knife intelligence boards
407 1 intelligence circuit board that there is not damage
circuit board communicaiton.
to it or the wire connecting the cirucit board.
408 1 KI broken wire detected. The KI wire on the bowl has broken. The wire needs to be fixed or replaced.
409 1 The chaff presser foot is clogged. The chaff presser foot is clogged. Remove the clog from the chaff presser foot.
A tool not found error occurred while processing JobFactory: While importing a queue job, a ToolNotFound
410 5 The job has not been submitted.
the run-time parameters in the JOB file: {0} exception was generated.
An error occurred while processing the run-time JobFactory: While importing a queue job, a
411 5 The job has not been submitted.
parameters in the JOB file: Filename: {0} InvalidJobInstanceException exception was generated.
A Distance Mapping error occurred while
JobFactory: While importing a queue job, a
412 5 processing the run-time parameters in the JOB file: The job has not been submitted.
InvalidOperationException exception was generated.
{0}
A Material Export Serialization Exception occurred:
413 5 TBD TBD
{0} - {1}
414 5 A Material Export IO Exception occurred: {0} - {1} TBD TBD

415 5 A Material Export SQL Exception occurred: {0} - {1} TBD TBD
A Material Export General Exception occurred: {0} -
416 5 TBD TBD
{1}
A Material Import Serialization Exception occurred:
417 5 TBD TBD
{0} - {1}
418 5 A Material Import IO Exception occurred: {0} - {1} TBD TBD

419 5 A Material Import SQL Exception occurred: {0} - {1} TBD TBD
A Material Import General Exception occurred: {0} -
420 5 TBD TBD
{1}
421 5 Material Import non-Exception error: {0} TBD TBD
422 5 Material Export non-Exception error: {0} TBD TBD
Exception thrown by JobSerializer.DeserializeFromFile(string
423 5 IO Exception reading file: {0} Ignore
file)
424 5 The tool in {0} cannot perform a trim cut. The tool is not a cutting tool. Put a cutting tool in the holder specified.
The specified JOB requires a velocity below the
425 5 TBD TBD
fixed rate velocity in order to be processed.
426 1 Unknown Error in Continuous Workflow. TBD TBD
There was an erroneous position command generated for Re-enable servos and try to continue. Try to
The delta commanded position ({0}) for axis {1} is
427 2 the axis. This could be due to an bug in the contour builder determine if the error is repeatable with the same
outside the valid range.
or related to the job file being cut. job file. Report as a software bug.

You might also like