g o t o wiki.larnitech.com go to contents
CONTENTS
About Us............................................................................................................................................................3
Our advantages..................................................................................................................................................4
Larnitech Smart Home System Architecture........................................................................................................5
Metaforsa – DE-MG comparison.........................................................................................................................8
Safety requirements...........................................................................................................................................10
Metaforsa series.................................................................................................................................................11
Metaforsa MF-10.............................................................................................................................................12
DW-HT07.........................................................................................................................................................13
DW-HT05.........................................................................................................................................................14
DIN rail equipment.............................................................................................................................................15
DE-MG.............................................................................................................................................................16
DE-GW.............................................................................................................................................................17
DW-LC18..........................................................................................................................................................18
DW-LC10..........................................................................................................................................................19
DW-LC07.........................................................................................................................................................20
DW-DM04........................................................................................................................................................21
DW-DM02........................................................................................................................................................22
DW-HC10.........................................................................................................................................................23
DW-HC08........................................................................................................................................................24
DW-RGB03......................................................................................................................................................25
DW-BC03.........................................................................................................................................................26
DW-WL02........................................................................................................................................................27
DW-SW16.........................................................................................................................................................28
DW-RS485.......................................................................................................................................................29
DW-RS232.......................................................................................................................................................30
DW-UART.........................................................................................................................................................31
DW-010............................................................................................................................................................32
DW-DALI..........................................................................................................................................................33
DW-DISPATCH.................................................................................................................................................34
1
g o t o wiki.larnitech.com go to contents
2
g o t o wiki.larnitech.com go to contents
About Us
Larnitech is a developer and manufacturer of ‘Smart Home’ systems for home
and office automation. The head office of the company is located in Cologne
(Germany).
Our new product line combines easy mounting and installation with a wide
range of the system functional features. The use of modern elements allows us
to create compact and economical devices.
Our team of designers and software developers has created user-friendly
software for managing the system, which allows our clients to manage the most
sophisticated tasks.
The modern world is experiencing an unprecedented boost in the sphere of
IT. We, at Larnitech, are fully aware of this trend and are doing everything in
our power to provide our own share of innovations in the field of smart house
technology. We strive to become a leader in our market niche. Through our high-
tech environment-friendly products, we contribute to saving the world’s natural
resources and fulfil our mission of developing modern housing that combines
progressive ideas, comfort and safety.
3
g o t o wiki.larnitech.com go to contents
Our advantages
• Really quick and easy equipment setup with true Plug&Play technology
• The basic setup of the system is done from a tablet and does not require special
coding skills
• Reliable support service, which responds to any queries fast
• Great conditions for cooperation
• Training provided
• Numerous ready-made scenarios (that enable the creation of a home that’s
truly smart)
• Voice control (Alexa, Siri and Google Home integrated)
• Free software for iOS, Android, Windows, Mac, Linux
• Remote control from any point of the world (Using cloud connection)
• German quality
• Integration with Nest, Philips Hue, Sonos and others
• The multiroom system is fully integrated into the Smart Home system (it is used
in scenarios, voice announcements, ‘following’ sound and others)
• Distributed logic with flexible architecture (there is no ‘central element’,
increased reliability, varying scope of the project, connection of up to 1000
devices)
• A wide range of equipment on offer allows to control all systems of a building
4
g o t o wiki.larnitech.com go to contents
POWER
ACTIVITY
DE-MG
ERROR
IRR
+24VDC
GROUND
CAN-L 120 Ohm
CAN-H
24VDC LAN
Terminator
CAN1 Terminator
CAN2
Terminator Terminator
Topology BUS
CAN BUS wire type FTP/UTP CAT 5E
Number of wires used 4-wire bus (two twisted pairs)
Max CAN BUS length 100 m
Max devices per CAN BUS 20
Terminator type Resistance 120 Ohm
The following diagram shows how modules can be connected to the system. In the drawing below a 7-channel
actuator, a leak control module and a heating control module have been connected to the first CAN bus.
The second CAN bus has a four-in-one multi-sensor, a dimmer and a two-channel pattress box space actuator. In such
a manner up to 40 devices can be connected to the main gateway.
5
g o t o wiki.larnitech.com go to contents
PWR
POWER PWR PWR
ACT
ACTIVITY ACT ACT
ERR
DE-MG
ERROR ERR ERR
IRR
DW-LC07 DW-WL02 DW-HC08
24VDC LAN
Terminator
CAN1 Terminator
CAN2
Terminator Terminator
BW-BC-PW.A BW-BC-PW.A
In its turn, the main gateway is connected to the Local Area Network.
If the building where the system is set up has several floors or 40 devices are not sufficient for performing all of your
tasks, additional extension modules are connected to the system. Each of them gives the user the ability to connect
40 more devices.
As many extension modules as needed may be added, therefore the system can be expanded almost indefinitely.
This way via the Local Area Network numerous CAN networks can be united into one network with the total number
of up to 1000 controlled modules.
Tablets or smartphones get connected to the local area network via Wi-Fi. After installing the Larnitech application on
your tablet or phone, you can control the devices in the system.
The main gateway is connected to the cloud, which allows to get authorized remote access to the Smart Home.
Cloud LAN
6
g o t o wiki.larnitech.com go to contents
The multiroom system is integrated via the local area network. The media points allow to reproduce music from
your home storage and internet radio. The multiroom system is deeply integrated into the Smart Home system,
which allows using it in various scenarios. For example, when you leave your home, the scenario ‘I’m gone’ can be
activated. In this scenario the system turns off the lighting, puts the climate control system in the energy saving mode
and with the help of the multiroom system can tell you about the unlocked back door or an open window.
Many media points can be connected to the system, which will allow listening to music in various areas. The music
may be taken from your network attached storage (NAS).
The system allows the use of the intercom. When someone rings your doorbell, the multiroom system will play the
notification about it. Of course, it will only do that in the areas where you want the notification to be played. If the
property owner is not at home, the system will let them speak to the visitor via the application on their smartphone
or tablet.
The multiroom system lets the user control smart TV and other devices which support the DLNA standard.
If you connect the IP cameras to the system, you will be able to see the corresponding areas through our application.
The API can be provided by Larnitech, which lets the third-party applications, after they are authorized, get the
information from the Smart Home system and control its devices.
POWER POWER
ACTIVITY ACTIVITY
ERROR
MEDIA POINT
FE-MP
ERROR
MEDIA POINT
FE-MP
NAS
Line Ethernet USB Power Line Ethernet USB Power
In In
Cloud LAN
API
ERR ERR ERR
DE-MG
ERROR ERR ERR ERR ERR
IRR
DW-LC07 DW-WL02 DW-HC08 DE-GW DW-LC07 DW-WL02 DW-HC08
7
g o t o wiki.larnitech.com go to contents
8
g o t o wiki.larnitech.com go to contents
Remote control
Remote connection that allows to control all Smart Home systems through direct or + +
cloud connection
API
Application programming interface that allows to exchange data and commands with + +
third party applications
Plug & Play
Technology that automatically detects and preconfigures new devices connected to + +
the system
Video cloud
Possibility to view the image from IP cameras with the help of cloud connection
limited +
Built-in inputs/outputs
Quantity of input and output channels that are built into the module in order to 16/10 –
connect the load and sensors
Number of CAN ports
1 2
Quantity of CAN ports in order to connect additional modules
Built-in IR receiver
Infrared receiver used to set up a universal remote – +
1
Can be extended with the license
2
Can be extended to 999 if requested
3
Continually expands
9
g o t o wiki.larnitech.com go to contents
Safety requirements
CAUTION! All work related to the installation, connection, setting up, service
and support must be carried out by qualified personnel with sufficient skills
and experience in working with electrical equipment.
To avoid the risk of fire, electric shock, damage to the system and / or personal
injury, the system installation and assembly must be performed in accordance
with the instructions listed below:
• all connection work must be carried out without power;
• use appropriate tools and personal protection against electric shock;
• do not use damaged cables, wires and connectors;
• avoid folding cables and wires;
• do not pinch or kink the cables and wires by applying excessive force. Otherwise,
inner conductors of the cables and wires may be stripped or broken;
• do not use the power socket with poor contacts to connect;
• do not exceed the load limit parameters specified in this manual;
• the supply conductors wire section is subject to the specifications for current
density limit, insulation type and wire material. Light section can result in cable
overheating and fire.
10
g o t o wiki.larnitech.com go to contents
Metaforsa series
11
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 10
Discrete input channels qty 16
Digital input channels qty 4
Input voltage 0-250 V
Current type AC/DC
Max load per channel 8A
Max load per group 20A
Power supply 11.5 … 12.5 V DC
X1 X2 X3 X4 X5 Max current(12V) 1A
BUS type CAN
C1
C2
C3
C4
C9
L5
C10
L3
L4
L1
L2
C5
C6
C7
C8
+12V
+12V
+12V
GND
GND
GND
GND
In10
In12
In13
In14
In15
In16
In11
LAN
Size 9U, 156x90x58 mm
In1
In2
In3
In4
In5
In6
In7
In8
In9
Power
X6 X7 X8 X9
+24V
GND
L
H
Weight 350 g
Сonnection example
220V AC
N L
AC/DC
12V 40A M
C1
C2
C3
C4
C9
L5
C10
L3
L4
L1
L2
C5
C6
C7
C8
Metaforsa series
POWER
ACTIVITY
ERROR METAFORSA
+12V
+12V
+12V
GND
GND
GND
GND
In10
In12
In13
In14
In15
In16
In11
LAN
In1
In2
In3
In4
In5
In6
In7
In8
In9
Ethernet
Temperature
sensors OW
12
g o t o wiki.larnitech.com go to contents
DW-HT07 This module has 7 outputs for connecting the load and 12
inputs for connecting various sensors/buttons.
7-CHANNEL
EXTENSION MODULE
Module parameters
Parameter name Value
Output channels qty 7
Discrete input channels qty 12
Digital input channels qty 4
Input voltage 0-250 V
Current type AC/DC
Max load per channel 8A
Max load per group 20A
Close
L1
L2
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
L3
GND
GND
In10
In12
In11
+5V
+5V
+5V
In1
In2
In3
In4
In5
In6
In7
In8
In9
Сonnection example
N
AC 220V
L M
Open
Close
L1
L2
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
L3
POWER
Metaforsa series
ACTIVITY
ERROR DW-HT07
+–LH One-Wire
GND
GND
GND
In10
In12
In11
+5V
+5V
+5V
In1
In2
In3
In4
In5
In6
In7
In8
In9
Temperature
sensors OW
Buttons SENSORS
13
g o t o wiki.larnitech.com go to contents
DW-HT05 Has 5 outputs for connecting load and 8 inputs for connecting
various sensors/buttons.
5-CHANNEL
MODULE
Module parameters
Parameter name Value
Output channels qty 5
Discrete input channels qty 8
Input voltage 0-250 V
Current type AC/DC
Max load per channel 8A
Max load per group 20A
Close
Ch1
Ch2
Ch3
Ch4
L1
L2
L3
GND
+5V
+5V
Weight 110 g
In1
In2
In3
In4
In5
In6
In7
In8
X4 X5
+24V
GND
L
H
Сonnection example
N
AC 220V
L M
Open
Close
L3
L1
L2
Ch1
Ch2
Ch3
Ch4
PWR
Metaforsa series
ACT
ERR
DW-HT05
+–LH
GND
GND
+5V
+5V
In1
In2
In3
In4
In5
In6
In7
In8
+24V
GND
L
H
Buttons SENSORS
14
g o t o wiki.larnitech.com go to contents
15
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Type of connection CAN, Ethernet
Input/output interfaces Ethernet, 2xCAN
Data speed 10/100Mb/s
Max CAN devices 40(20 per CAN)
CAN bus topology BUS
Number of CAN ports 2
Power supply 11.5 … 27.5 V DC
24V, 2.5A Recommended
Max own current (24V) 140mA
Max CAN bus length 100m
Max CAN bus current 700mA
IR Receiver angle 30°
Case material ABS
Protection IP40
Equipment installation type DIN rail(EN 60715)
1. Indicators 5. Power supply
2. IR Receiver 6. CAN1 Temperature range -10 … +50°C
3. Recovery button 7. CAN2 Size 6U, 104x90x58 mm
4. Recovery LED 8. Ethernet Weight 145 g
Сonnection example
DIN railequipment
16
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Type of connection CAN, Ethernet
Input/output interfaces Ethernet, 2xCAN
Data speed 10/100Mb/s
Max CAN devices 40(20 per CAN)
CAN bus topology BUS
Number of CAN ports 2
Power supply 11.5 … 27.5 V DC
24V, 2.5A Recommended
Max own current (24V) 60mA
Max CAN bus length 100m
Max CAN bus current 700mA
Case material ABS
Protection IP40
Equipment installation type DIN rail(EN 60715)
Temperature range -10 … +50°C
Size 2U, 35x90x58 mm
Сonnection example
DIN railequipment
17
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 18
Input voltage 0-250V
Current type AC/DC
Max load per channel 8A
Max load per group 20 A
Max load per device 100 A
C4
C5
C6
C7
L1
L2
L3
L4
L5
L6
C8
C9
C12
C13
C14
C15
C16
C17
C18
L10
L8
L7
L9
Сonnection example
L
~220V
N
Water/gas
valve
DIN railequipment
C11
C10
L1
C8
C9
C1
C2
C3
C4
C5
C6
C7
L5
L6
L3
L4
L2
POWER
ACTIVITY
ERROR DW-LC18
+–LH
C12
C13
C14
C15
C16
C17
C18
L10
L8
L7
L9
+24V
GND
L
H
Fancoil
Gate
actuator control
unit
18
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 10
Input voltage 0-250V
Current type AC/DC
Max load per channel 8A
Max load per group 20 A
Max load per device 60 A
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 315 mA
Permissible section of power
supply cable to connect in socket:
single-conductor cable 0.5 … 4mm2
multiple-conductor cable 0.5 … 4mm2
tipped multiple-conductor cable 0.5 … 2.5mm2
Bus type CAN (4-wire)
+–LH
Equipment installation type DIN rail(EN 60715)
Case material ABS
+24V
GND
L
H
Protection IP40
Temperature range -10 … +50 °C
Size 6U, 104x90x58 mm
Weight 250 g
Сonnection example
L
~220V
N
Water/gas
valve
DIN railequipment
C1
C2
C3
C4
C5
C6
C7
L1
L2
L3
L4
POWER
ACTIVITY
ERROR DW-LC10
+–LH
C10
C8
C9
L5
L6
+24V
GND
L
H
Gate
actuator
19
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 7
Input voltage 0-250V
Current type AC/DC
Max load per channel 8A
Max load per group 20 A
Max load per device 40 A
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 315 mA
Permissible section of power
supply cable to connect in socket:
single-conductor cable 0.5 … 4mm2
multiple-conductor cable 0.5 … 4mm2
tipped multiple-conductor cable 0.5 … 2.5mm2
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
+–LH
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
+24V
GND
L
H
Сonnection example
L
~220V
N
DIN railequipment
C1
C2
C3
C4
L1
L2
PWR
ACT
ERR
DW-LC07
+–LH
C5
C6
C7
L3
L4
+24V
GND
L
H
Gate
actuator
20
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 4
Input voltage 100-240V AC, 50-60 Hz
Current type AC
Max load per device 9.1A (2000W at 220V)
Max load per channel 2.27A (500W at 220V)
Dimmer type MOSFET
Dimming type trailing edge
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 35 mA
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 4U, 69x85x58 mm
Weight 360 g
Conventional
N
L
0-500W
incandescent lamps
Led N
LED lamps with dimming
0-500W
support
21
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 2
Input voltage 100-240V AC, 50-60 Hz
Current type AC
Max load per device 9.1A (2000W at 220V)
Max load per channel 4.55A (1000W at 220V)
Dimmer type MOSFET
Dimming type trailing edge
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 35 mA
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 4U, 69x85x58 mm
Weight 360 g
Conventional
Ch2
Ch2
Ch1
Ch1
0-1000W
PE
incandescent lamps
N
L
L
Led N
LED lamps with dimming
0-1000W
support
22
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Input channels qty 10
Output channels qty 10
Input voltage 20-250 V
Current type AC/DC
Max load per channel 0.5A (110W at 220V)
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 110 mA
Sensors line max length 30 m
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 4U, 69x85x58 mm
Weight 140 g
ts
ts
DIN railequipment
ts
ts
ts
ts
ts
ts
ts
N ts
+5V
6A
L
23
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 8
Input channels qty 8
Input voltage 20-250V
Current type AC/DC
Max load per channel 0.5A (110W at 220V)
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 90 mA
Sensors line max length 30 m
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 4U, 69x85x58 mm
Weight 140 g
ts
ts
ts
DIN railequipment
ts
+5V
GND
ts
ts
ts
N
ts
+5V
6A
L
24
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 9
Input voltage 11.5 … 25V DC
Current type DC
Adjustment type PWM
Max current (per channel) 1.67A (20W at 12V)
Max current (device) 15A (180W at 12V)
Power supply 11.5 … 27.5 V DC from CAN
X1 connector
Max current(24V) 55 mA
X2 conneсtor
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Power LED PWR
Case material ABS
Activity LED ACT
Error LED ERR Protection IP40
X3 conneсtor
CAN connector
+
+12V
GND
RGB LED
power
–
G
R
B
supply
X1,X2,X3
connectors
B G R +
DIN railequipment
+
CAN connector power
– supply
H
L
B G R +
25
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 3
Input voltage 100-250 V AC
Current type AC
Max load per channel 2A
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 55 mA
Connection type CAN
X1 connector
Permissible section of power 0.5 … 2.5mm2
supply cable to connect in socket
X2 conneсtor
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Power LED PWR
Activity LED ACT Case material ABS
Error LED ERR Protection IP40
DW-BC03 Temperature range -10 … +50 °C
Size 2U, 35x90x58 mm
Weight 95g
CAN connector
Connection of curtain/jalousie/
shutter actuators
C1 L1 C2
X1 connector 6A L
1-st channel
Close
Open M N
C5 L3 C6 C3 L2 C4
C1 L1 C2
X2 conneсtor
DIN railequipment
3-th 2-nd
channel channel
6A L
M
Close
Open N
Close
CAN connector Open
M
GND
+24V
C5 L3 C6 C3 L2 C4
H
L
26
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 2
Number of sensor inputs 4
Number of dry contact inputs 4
Input voltage 100-250 V AC
Current type AC
Max load per channel 2А
Power supply 11.5 … 27.5 V DC from CAN
X1 connector
Max current(24V) 60 mA
Sensors VCC output 8..12 V
X2 conneсtor
Sensors max VCC current 70 mA
S1-S4 inputs max current 3 mA
Power LED PWR
Sensor line max length 30m
Activity LED ACT
Error LED ERR Bus type CAN (4-wire)
X1 connector
Connection of valves and sensors
+ + S2 S3 I4 I2 GND
in
+ + S4 S1 I3 I1 ++ S2 S3 I4 I2
++ S4 S1 I3 I1
GND
Input Leakage
DIN railequipment
+12V Sensor
C1 L1 C2 C3 L2 C4
X2 conneсtor ~220
N L
Single-
pole
valve
Close
Bipolar
Open valve
CAN connector
GND
+24V
H
L
C1 L1 C2 C3 L2 C4
27
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 16
Buttons 15
LED Buttons 8
Backlight voltage 3V
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 45mA
Bus type CAN (4-wire)
X1
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
+–LH
+24V
GND
L
H
Сonnection example
GND
X1 connector Button1...Button 15
DIN railequipment
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
LED LED
Button1...Button 8
28
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
RS485 ports qty 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 40mA
Data transfer speed 1200-115200 b/s
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
GND
NC
A
B
DW-RS485
+–LH
+24V
GND
L
H
Сonnection example
External
device
A
B
DIN railequipment
GND
NC
A
B
PWR
ACT
ERR
DW-RS485
29
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
RS232 ports qty 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 40mA
Data transfer speed 1200-115200 b/s
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
GND
NC
Protection IP40
Rx
Tx
+–LH
+24V
GND
L
H
Сonnection example
External
device
Rx
Tx
DIN railequipment
GND
NC
Rx
Tx
PWR
ACT
ERR
DW-RS232
30
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
UART ports qty 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 40mA
Data transfer speed 1200-115200 b/s
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
GND
NC
Rx
Tx
Protection IP40
PWR
Temperature range -10 … +50 °C
ACT Size 2U, 36x90x58 mm
ERR
Weight 130g
DW-UART
+–LH
+24V
GND
L
H
Сonnection example
External
device
Rx
Tx
DIN railequipment
GND
NC
Rx
Tx
PWR
ACT
ERR
DW-UART
31
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels quantity 4
Max load per channel 15mA
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 50mA
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
X1 Protection IP40
4321-
Temperature range -10 … +50 °C
Size 2U, 36x90x58 mm
PWR
Weight 130g
ACT
ERR
DW-010
+–LH
+24V
GND
L
H
Сonnection example
4321- 0-10V
device
DIN railequipment
PWR 0-10V
ACT device
ERR
DW-010 0-10V
device
0-10V
+–LH device
32
g o t o wiki.larnitech.com go to contents
DW-DALI This is the module needed to connect the lamp drivers that
are controlled with the help of DALI protocol.
2-CHANNEL DALI
INTERFACE ADAPTER
Module parameters
Parameter name Value
DALI ports qty 2
DALI-line voltage supply 23.5 ... 24.5 V DC
Max current of DALI-line power 1A
supply
Max current in DALI-line 300 mA
Maximum DALI devices quantity 641
DALI-line maximum length 100 m
D1+
D2–
D1–
+24V
GND
Сonnection example
Power
D2+
D1+
D2–
D1–
DALI DALI
+24V
GND
supply
DIN railequipment
DALI DALI
DEVICE +– LH
DEVICE
33
g o t o wiki.larnitech.com go to contents
DW-DISPATCH This module is for the dispatch system only. It is not used in
the main Larnitech Smart Home system.
AMR (AUTOMATIC
METER READING)
MODULE
Module parameters
Parameter name Value
M-BUS port quantity 1
RS485 port quantity 1
Pulse inputs quantity 20
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 300 mA
Bus type CAN (4-wire)
Equipment installation type DIN rail(EN 60715)
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
X1 X2
RS/Mbus Size 4U, 69x85x58 mm
In6
In7
In8
In9
In10
GND
In1
In2
In3
In4
In5
GND
Weight 130g
PWR
ACT
ERR Сonnection example
DW-DISPATCH
Pulse water
Electricity counters counters
Max qty 10
+–LH
GND
GND
In16
In17
In18
In19
In20
In12
In13
In14
In15
In11
Heating counters
Max qty 10
X3 X4
+24V
GND
L
H
In6
In7
In8
In9
In10
GND
In1
In2
In3
In4
In5
GND
RS/Mbus
PWR
ACT
ERR
DW-DISPATCH
DIN railequipment
GND
GND
In16
In17
In18
In19
In20
In12
In13
In14
In15
In11
Pulse water
counters
34
g o t o wiki.larnitech.com go to contents
35
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 2
Input channels qty 6
Buttons 6
LED Buttons 5
Input voltage 100-250 V
Current type AC
Max load per channel 2 A (440W at 220V)
Backlight voltage 3V
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 35 mA
Permissible section of power
supply cable to connect in socket:
single-conductor cable 0.5 … 2.5mm2
multiple-conductor cable 0.5 … 2.5mm2
tipped multiple-conductor cable 0.5 … 2.5mm2
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
Сonnection example
Pattress box equipment
Temperature
sensor
L
GND
6 N
BW-LC02.A
3 buttons
36
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 1
Input channels qty 3
Input voltage 100-250 V 50Hz
Current type AC
Max load 0.9A (200W at 220V)
Min load 0.09A (20W at 220V)
Max current(24V) 40 mA
Load type Value Bus type CAN (4-wire)
Mounting Free
Conventional
20-200W
incandescent lamps Case material ABS
Protection IP40
Halogen light sources 20-200W Temperature range -10 … +50 °C
Size 45x42x14 mm
Led
LED lamps with Weight 25 g
20-200W
dimming support
Сonnection example
DIN railequipment
GND
L
BW-DM.A N
3 buttons
37
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 1
Input channels qty 6
Buttons 6
LED Buttons 5
Input voltage 100-250 V AC
Current type AC
Max load per channel 2A
Backlight voltage 3V
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 30 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
Сonnection example
Pattress box equipment
Temperature
sensor
L
GND
Open Blinds N
Close M
6
BW-BC-PW.A
3 buttons
38
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 1
Input channels qty 6
Buttons 6
LED Buttons 5
Input voltage 0-50V
Current type AC/DC
Max load per channel 0.5 A
Backlight voltage 3V
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 30 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
Сonnection example
Temperature
sensor
DIN railequipment
GND M
CO
Gate
6
controller
BW-BC-LC.A
3 buttons
39
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Output channels qty 3
Input voltage 11.5 … 25V
Current type DC
Adjustment type PWM
Max load per channel 1 A (12W at 12V)
Max load power per device 3A (36W at 12V)
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
Сonnection example
+12V GND
Pattress box equipment
BW-RGB.A
+12V
CAN
Red COM H
R L
G GND
Green B + 24V
Blue
40
g o t o wiki.larnitech.com go to contents
6-CHANNEL INPUT
MODULE
Module parameters
Parameter name Value
Input channels qty 6
Buttons 6
LED Buttons 5
Backlight voltage 3V
Max current(24V) 30 mA
Power supply 11.5 … 27.5 V DC from CAN
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
Сonnection example
Temperature BW-SW06.A
sensor
G CAN
H
DIN railequipment
L
GND
+ 24V
3 buttons
41
g o t o wiki.larnitech.com go to contents
BW-LSA This module allows connecting two leakage sensors and has
the function of detecting the presence of the sensor.
LEAKAGE SENSOR
ADAPTER
Module parameters
Parameter name Value
Input channels qty 2
Power supply 23 … 25 V DC from CAN
Max current(24V) 65 mA
Bus type CAN (4-wire)
EW-WL
Compatible with
FW-WL
Output voltage 12V
Output current 20 mA
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
BW-LSA.A
Pattress box equipment
CAN
+9V
In 1 H
GND L
+9V
In 2
GND
GND + 24V
42
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Input channels qty 3
Output channels qty 3
Voltage that may be applied to
0...15 V DC
the input channels
Min detected voltage threshold 2.5V
Max output switching voltage 60V AC/DC
Max output switching current 50mA
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
Input 1+
–
Input 2+ BW-IO.A
–
Input 3
+
– CAN
1 6 H
DIN railequipment
2 5
L
GND
3 4 + 24V
Output 1
Output 2
Output 3
43
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Input channels qty 5
Power supply 23 … 25 V DC from CAN
Max current(24V) 70 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
BW-NA.A
Pattress box equipment
W1 CAN
W2 H
Y1
L
NEST Y2
G GND
C
RH
+ 24V
44
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
RS485 port quantity 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
BW-RS485.A
CAN
DIN railequipment
B B
RS485
H
A A L
COM COM
device
GND
NC + 24V
45
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
RS232 port quantity 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
Pattress box equipment
BW-RS232.A
CAN
Tx Rx
RS232
H
Rx Tx L
COM COM
device
GND
NC + 24V
46
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
UART port quantity 1
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 15 g
Сonnection example
BW-UART.A
CAN
DIN railequipment
Tx Rx
UART
H
Rx Tx L
COM COM
device
GND
NC + 24V
47
g o t o wiki.larnitech.com go to contents
Сonnection example
0-10V device
Pattress box equipment
BW-010.A
0-10V device
48
g o t o wiki.larnitech.com go to contents
Sensors
49
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Control parameters Humidity, lighting, motion
Angle of vision IR 360°
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 100 mA
Bus type CAN (4-wire)
Mounting Wall, ceiling
Case material ABS
Humidity Motion Protection IP40
& lighting sensor
sensor Temperature range -10 … +50 °C
Size 80x70x25 mm
Weight 30g
IR transmitters
Сonnection example
IR transmitter
coverage area 30°
100°
Motion sensor
coverage area
IR transmitter
coverage area
Sensors
IR transmitter IR transmitter
coverage area coverage area
50
g o t o wiki.larnitech.com go to contents
CW-MLI.A / CW-M.A This module contains motion, lighting (CW-MLI only) sensors
and an IR transmitter (CW-MLI only).
MICRO-SIZED 3 IN 1
SENSOR
Module parameters
Parameter name Value
Control parameters Motion, lighting(optional)
Angle of vision IR 30°
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 50 mA
Max detection distance 10m
Bus type CAN (4-wire)
Mounting Cell.
Protection IP40
Temperature range -10 … +50 °C
Size 17x17x60 mm
Weight 15 g
Сonnection example
Direc
tion o
f IR s
ignal
100°
Motion sensor
coverage area
CAN
Sensors
IR transmitter
30°
coverage area
51
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Control parameters Temperature, humidity, lighting
Temperature measuring range -10 … +50°C
Humidity measuring range 0 … 100%
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Bus type CAN (4-wire)
Mounting Wall, ceiling
Case material ABS
Protection IP40
Size 40x40x12
Weight 50 g
Sensors
52
g o t o wiki.larnitech.com go to contents
TEMPERATURE
SENSOR
Module parameters
Parameter name Value
Control parameters Temperature
Temperature measuring range -20 … +60°C
Power supply 5 V DC
Max current 5 mA
Bus type One Wire
DW-HCxx
BW-LC/BCxx/SW
Compatible with
DW-HTO7
Metaforsa MF-10
Mounting Wall
Case material ABS
Protection IP40
Size 40x40x12 mm
Weight 35 g
Сonnection example
WW-TS
GND
GND
+5v
Data
6
Sensors
BW-LC02.A
53
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Control parameters Temperature
Temperature measuring range -20 … +60°C
Power supply 5 V DC
Max current 5 mA
Bus type One Wire
DW-HCxx
BW-LC/BCxx/SW
Compatible with
DW-HTO7
Metaforsa MF-10
Mounting Free
Protection IP40
Size 5x4x8 mm
Weight 15 g
+5V (Orange)
Data (Orange-white)
FW-TS
COM (Green)
Сonnection example
GND
Data FW-TS
Sensors
+5V
54
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Control parameters Temperature
Temperature measuring range -20 … +60°C
Power supply 5 V DC
Max current 5 mA
Bus type One Wire
DW-HCxx
BW-LC/BCxx/SW
Compatible with
DW-HTO7
Metaforsa MF-10
Mounting Built into the floor/outdoor surface
Protection IP65
Size 8x8x50 mm
Weight 35 g
+5V (Red)
Data (Yellow)
FW-FT
COM (Black)
Сonnection example
GND
Data FW-FT
Sensors
+5V
55
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Power supply 9...12 V DC
Max current 20 mA
Metaforsa MF-10
Compatible with DW-WL02/HTxx
BW-LSA
Mounting Built into the floor
Case material stainless steel
Protection IP65
Temperature range -10 … +50 °C
Size 18x18x20 mm
Weight 20 g
EW-WL
+9V (Red)
Data (White)
GND (Black)
Сonnection example
EW-WL BW-LSA.A
+9V
CAN
+9V
Data In 1 H
GND
GND L
+9V
In 2
GND
GND + 24V
Sensors
56
g o t o wiki.larnitech.com go to contents
FW-WL The sensor is placed on the floor surface. It has an alarm light,
which changes from green to red if the sensor detects water
ON-THE-FLOOR on the floor. Used together with DW-WL or BW-LSA modules.
LEAKAGE SENSOR
Module parameters
Parameter name Value
Power supply 9...12 V DC
Max current 20 mA
Metaforsa MF-10
Compatible with DW-WL02/HTxx
BW-LSA
Mounting Free
Case material ABS
Protection IP64
Temperature range -10 … +50 °C
Size 57x47x22 mm
Weight 35 g
DIP switch
ON
1 OFF 2
Сonnection example
GND
Data
+9V
+9V
CAN
+9V
№ Description Data In 1 H
GND
ON – Ultra-sensitive mode GND L
1 +9V
OFF – Regular mode In 2
GND
GND + 24V
ON – Blue LED color
2
OFF – Green LED color
Sensors
57
g o t o wiki.larnitech.com go to contents
Multiroom
58
g o t o wiki.larnitech.com go to contents
Module parameters
Parameter name Value
Analog outout channels qty 2
Speakers 4-8 ohm
Max power output audio channel 2x20W
Connection type Ethernet
Transfer data speed 10/100 MB/s
Power supply 23...26V DC
3.3 A,
Max current(24V)
24V 4.2 A Recommended
Case material Aluminium
Protection IP40
Mounting type Free
Temperature range -10…+50 °C
Dimensions 140x64x30 mm
Weight 500 g
Multiroom
59
g o t o wiki.larnitech.com go to contents
FE-IC Video intercom calling panel. It has a built-in 1MP camera with
IR illumination and a relay for connecting the electric lock. It
VIDEO INTERCOM also has a built-in 2Gb memory for taking photos or recording
videos. Supports SIP and DLNA protocols.
Module parameters
Parameter name Value
Camera 1 MP (1280 x 720)
IR lighting 1m
Connection type Ethernet
Protocols SIP, DLNA
11.5 … 27.5 V DC,
Power supply
Pussive POE 24V
Max current(24V) 150 mA
Aluminium alloy panel,
Case material
Waterproof
Protection IP65
Mounting type Wall surface mount
IR Backlight
Temperature range -20…+50 °C
Light sensor MIC
Dimensions 153x85x45 mm
Weight 620 g
IP CAM
Call button
Speaker
Multiroom
60