Relay s

Technical Data

Relay 721

Description

For new developments we recommend to use


relay type 725.

Polarized latching relay for 100 A

Using the H-armature principle the polarised latching


relays are noted for their high resistance to shocks and
vibrations. They are always in a de­fined switching position
and therefore there is no loss of information in case of
power failure. The advantage of po­la­rised latching relays
is the pulse driven operation of some milliseconds, coil
heating can be neglected. Optionally the relay can also be
set by manual operation.

The relays are designed and manufactured in accordance


to international standards of IEC 61810 part 1 as well as
they meet the UC3 requirements for Supply Control
Switches as of IEC 62052 part 31.

Technical data

Coil data Rated voltage 6 – 48 VDC


Rated power 4.5 W
Operating power to set 3.0 W
Pulse to set 20 ms
Action time < 15 ms
Contact data Max. contact arrangement 1a
Contact material AgSnO2
2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications

Max. switching power 25,000 VA


Max. switching voltage 440 VAC
Max. switching current 100 A
Mechanical life 106
Insulation Creepage and clearance distance 8 mm
coil – contact
Test voltage 4,000 V eff.
coil – contact
Test voltage –
contact – contact
Test voltage 1,000 V eff.
open contact
Dielectric strength 12 kV / 1.2 / 50 µs
coil – contact
General data Ambient temperature -40 … +85 °C
Weight 75 g
Conform to VDE, UL, CSA, SEV, SEMKO

1/7
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Standard windings

Standard winding Nominal coil Operating voltage Coil resistance Tolerance The relay coil with double winding can
No. voltage of the coil also be used as a single winding with half
Double winding (VDC) U1 – U2 (VDC) (Ohm) (± %) operating power if the middle pin of the
8R0 6 4.8 – 7.8 2x8 10 coil is not used.
032 12 9.6 – 15.6 2 x 32 10
125 24 19.2 – 31.2 2 x 125 10
Contact position
500 48 38.4 – 62.4 2 x 500 10

Terminal-grid H 1(-)/5(+) 2(-)/5(+)


B 3(-)/4(+) 2(-)/4(+)

Identification

721 C - R 1A - B 125 Example for ordering

Identification code
Type 721
Terminal configuration A = see dim. drawing
C = see dim. drawing
CR = see dim. drawing
D = see dim. drawing
DR = see dim. drawing
F = see dim. drawing
G = see dim. drawing
FR = see dim. drawing
V = see dim. drawing
VR = see dim. drawing

Contact material R = AgSnO2 Further versions


Contact arrangement 1A = 1 normally open on request
Terminal-grid B/H
Winding No. see coil table

The power terminals can be modified according to customer specification.


2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications

Advice for soldering:

The relay is dust-protected. Take care to avoid that flux medium and lead-tin resp. their
evaporations enter into the relay, i.e. the printed circuit board must not be flooded.

Extended storage could impact solderabilty due to increased oxidation on the terminals.

Shunt:

A shunt is integrated into one of the power terminals of the type 721 CR/DR/FR/VR. It
is used to measure the energy consumed and, as it is integrated in the relay, can be
utilised for load shedding in “Energy Ma­nage­ment”. Two connectors are located on the
terminal close to the shunt and only carry the current sensor signal. A third connec-
tor is the reference signal for the electronics and is located on the supply side of the
terminal to avoid RF sensitivity.

2/7
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Technical drawing

Ø6(2x)
Ø3,2(2x)

2,5

90°
3
Ø1,6
4
MONITORING HOLES

13
11
4,9±0,05

4,2 22
38,6 FIXING HOLE 2
31,5

4,1
10

14,6
21,6
10

33,4

43
4,9±0,05

9,6

3 4 2
FIXING HOLE 0,64 2
5
10
10
15,7
33
721 A 52
4

Ø1,6

Ø6(2x)
90°
Ø3,2(2x) 3
Ø4,2

4
2,5
(2x)

2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications


10

22
10

21 38,6 FIXING HOLE


31,5
4,1
3
2

14,6
7,4

33,4

43
2

9,6

3 4 2
FIXING HOLE 0,64
5 15,7
10
33
721 C 52

3/7
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Technical drawing

Ø6(2x)
Ø3,2(2x)

2,5
16,5

FIXING HOLES 11
38,6 M6
31,5

4,1

15,9
16,5
3

14,6
7,4

44,35
33,4

43
7,6
9,6

M6

0,6
2 4
0,64 15,7
8 5
16,5
10 22
33
52
721 D

switching position
contacts

Terminal pin 3/4 4/2


arrangement (+) (+)
Ø6(2x)

Ø3,2(2x)
7,85±0,1

2,5

7
22
15

2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications


11,25

38,6 FIXING HOLE

31,5
4,1
2

14,6
33,4

43
6,9
29,1

2,5
5,1

9.6

3 4 2
FIXING HOLE
15,7
0.64
8 11,25
5
15
10

33

721 F 52

4/7
Cu-THICKNESS 2±0.03mm

UNSPECIFIED CHAMPFER 0.5x45∞ switching position


DIMENSION: mm contacts
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Technical drawing

2,5
10
3,2 ( 2x)
6 ( 2x)
M5

52 F I X I NG HO LE S
38,6
31,5 22

4,1
2

14,6
33,4
2

10

3 4 2

F I X I N G HO LE S 5 0,64
10 15,76
9,6

33

M5
5,5
10

721 G

48,5 ±0,2
12

2,5
0,0
10,00 - 0,3
10

3,2 (2x)
10

6 (2x)
42 ±0,2

52 FIXING HOLES
0,1 A
54 38,6
2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications

31,5 22
A
4,1
1,6
7,8

14,6
R2

721V-R1A-Bxxx
GRUNER
30°

R3

33,4
100A / 250VAC
xR/xR
Qx JJKWT

xVDC

xxxxx

14 12

3 4 2

FIXING HOLES 5 0,64


6,7

10
33

M5

5,5
5,5 ±0,05

721 V
5,4

5/7
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Technical drawing

M 2:1
Shunt 721 CR

4
SHUNT
at 20 °C: 240 µΩ / 180 µΩ

Ø1,6
Ø6(2x)
90°
Ø3,2(2x)
2,5 3 at 0 °C: -0.1 %
Ø4,2

4
at 75 °C: -0.2 %
at 150 °C: -0.6 %
10

22
10

Further resistance values


upon request

21 38,6 FIXING HOLE


31,5
4,1
3
2

14,6
7,4

33,4

43
2

9,6

3 4 2
FIXING HOLE 0,64
5 15,7
10
721 CR 33
(shunt) 52

Ø6(2x)
Ø3,2(2x) Z Shunt 721 DR
1 M 2:1
Ø1,6
2,5

90°
at 20 °C: 120 / 140 / 200 µΩ
at 0 °C: -0.1 %
3
22

at 75 °C: -0.2 %
5
at 150 °C: -0.6 %
2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications

16,5
Further resistance values
2 11
FIXING HOLES upon request
38,6 M6
31,5
4,1

15,9
16,5

3
Z
14,6
7,4

SHUNT
44,35
33,4

43

10
10
7,6
9,6

M6

2 4
0,64 15,7
8 5
16,5
10 22
721 DR 33 3,5
(shunt) 52

switching position
contacts
Shunt
at 20°C 120μOhm / 140μOhm/ 200μOhm
at 0°C -0,1%
Terminal pin
arrangement
3/4
(+)
4/2
(+) 6/7
at 75°C -0,2%
at 150°C -0,6%

LATCHING RELAY
Relay 721 Re l a ys >> Te c h n ic a l Da t a

Technical drawing

(3x) X
4:1
4,50 Shunt 721 FR
M6
2,10
at 20 °C: 120 / 140 / 200 µΩ
at 0 °C: -0.1 %
15

at 75 °C: -0.2 %

2,80
90°
at 150 °C: -0.6 %
7,85 ±0,1
11 ±0,15

3,2 (2x)

2,5
6 (2x)
1,60
Further resistance values
upon request
27,6
20,6 ±0,15 22
FIXING HOLE
38,6
3,8

2,5

4,1

3,85 31,5
2

X
14,6

10,00
7,00
GRUNER
721FR-R1A-B032
7,00 ±0,15
6,83

43
33,4
12VDC
100A / 250VAC
Qx JJKWT

32R/32R
31,00

M6
xxxxx

10,00
4,50
3 4 2

2,00
6,7

FIXING HOLE 0,64


4,1
3,80 11,00 ±0,15
5 16,50
721 FR 7,85 10
33 15,5
(shunt)
52

Z
48,5 ±0,2 1,6 5:1 Shunt 721 VR

at 20 °C: 150 µΩ
12

2,5

at 0 °C: -0.1 %
0,5

Z
0,00
10 -0,30

at 75 °C: -0.2 %
10

3,2 (2x)
10

42 ±0,2
6 (2x) 90° at 150 °C: -0.6 %
3

52 FIXING HOLE
Further resistance values
0,1 A
54 38,6 upon request
2017-08-21 · Copyright by GRUNER AG · Subject to technical changes and design modifications

31,5 22
4,1

A
1,6
2

14,6
R2 R3
30°
7,8

33,4
2

14 12

3 4 2

FIXING HOLE 5 0,64


6,7

10
33

M5
5,5
5,5 ±0,05

721 VR
5,4

(shunt) 6
7
6,3 11

GRUNER AG
D-78564 Wehingen · Germany
7/7
Phone +49 7426 948-0 · Fax +49 7426 948-200 · www.gruner.de · info@gruner.de

You might also like