You are on page 1of 19

M860 Handheld Monitor

Service Manual

GuangDong Biolight Meditch Co,.ltd


No.2 Innovation First Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai , P.R.China

Tel: +86-756-3399900 Fax: +86-756-3399989


http://www.blt.com.cn
M850 Handheld Monitor service manual

Content
Preface....................................................................................................................................... 3

Service information ................................................................................................................... 3

Safety ........................................................................................................................................ 4

Safety Information .................................................................................................................... 4

Explanation of Symbols ............................................................................................................ 5

Overview ................................................................................................................................... 6

Product Composing ........................................................................................................... 6

Inner Structure ................................................................................................................... 6

Accessories ................................................................................................................................ 7

Testing ....................................................................................................................................... 9

Power supply testing ......................................................................................................... 9

SpO2 testing ....................................................................................................................... 9

Alarm lamb & Speaker testing .......................................................................................... 9

Maintenance and Cleaning ...................................................................................................... 10

Introduction ..................................................................................................................... 10

Maintenance and Cleaning .............................................................................................. 10

Menu Tree ............................................................................................................................... 12

Trouble shooting ..................................................................................................................... 13

Disassembly ............................................................................................................................ 15

Explosive view ........................................................................................................................ 18

2
M850 Handheld Monitor service manual

Preface

Introduction
The service manual describes hardware composing, installation, dismantling, testing and fault resolution of
product and its accessories to help maintenance personnel to effectively deal with FAQ. The service manual
doesn’t introduce the product structure and design principles. If there is still some problem unable to be fixed,
please contact our service department.
The service manual introduces the product with all the configurations, so that some part of the content may not
apply to your product. If you have any questions, please contact our service department.
Please read this manual and ensure completely understanding it before repair to guarantee repair and maintenance
in a right way and avoid causing product damage or personal injury.
This manual applies to professional biological engineer, authorized maintenance personnel or after–sales service
representatives who are responsible for the maintenance of this product.

Service information
(1) Requirements: Please observe the following requirements.
(1.1) Only consult the customer service center of our company for after-sales service of the instrument.
(1.2) Damage of the instrument caused by unauthorized maintenance is not within the scope of guarantee for
repair.
(1.3) Conduct regular maintenance to the monitor according to the preset plan; otherwise, the instrument will have
troubles, or even cause damage.
(1.4) During the lifespan of the instrument, regular maintenance is one of the necessary measures to ensure the
normal use of the monitor.
(2) Identification of the instrument: Each of the monitors produced by our company is attached with a unique
production serial number for identification and after-sales service.
(3) Consultation by phone
You have made the correct choice for buying Multi-parameter Monitor with high standards of quality and
reliability. Whenever you need help, feel free to dial the after-sales service hotline of Company. Before dialing,
please confirm:
① You have read the User’s Manual, and are sure that the operation is correct.
② You have read the installation instructions and answers to difficult problems in the manual, and still cannot
solve your problem.
③ Before dialing, be sure to get the following information ready:
-- Serial number of the monitor (in the label at the back)
-- Type of the monitor (in the label at the back)
-- Program version of the monitor
-- Troubles of the monitor

3
M850 Handheld Monitor service manual

Safety

Safety Information

 Warning:
 Explosion hazard: Do not use the monitor in the presence of flammable anesthetics mixture with air,
oxygen, or hydrogen.
 When the monitor is in use, there should not be any great power appliances as high voltage cables,
X-ray machine, ultrasound equipment and electrizer in use nearby.
 Keep the monitor away from dust, vibration, corrosive substances, explosive materials, high
temperature and moisture.
 The monitor is not designed for the sterilized room.
 The monitor should be handled with care so as to avoid shocks and falls.

 Warning:
 Do not use this device during defibrillation.
 When the monitor is in use, it must be ensured the batteries have sufficient capacity; otherwise there
might be such phenomena as starting-up abnormalities or inaccurate measurement data, etc.
 Do not conduct SpO2 measurement on the finger smeared with nail polish; otherwise this will lead to
unreliable measurement results.
 Measurements and pulse signals can be affected by certain environmental conditions, sensor
application errors, and certain patient conditions. See the appropriate sections of this manual for
specific safety information.
 The use of accessories, sensors, and cables other than those specified may result in increased emission,
low anti-disturbance and/or create invalid readings of the monitor. It is advised to check it at least
once a month.

Caution: In order to have more accurate measurements results, the monitor should be used in quiet
and comfortable environment.

4
M850 Handheld Monitor service manual

Explanation of Symbols

Symbol Symbol Note

Type CF applied part

Attention: Consult accompanying documents (this manual).

Direct Current(DC)

IPX1 Degree of protection against ingress of liquid

Alarm volume off

Alarm volume pause

parameter alarm off

Symbol Symbol Note

Beep volume off

Power supply connector

Left/right button

Up button

Down button

Date of manufacture

Manufacturer

SN Serial number

Power button

Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC.

5
M850 Handheld Monitor service manual

Overview

Product Composing

1
7
2

3
8
5 6
9
4 11

10

1 Screen 2 Main menu 3 Home key


4 Alarm suspend 5 USB connector 6 NIBP button
7 Power button 8 NIBP connector 9 SpO2 connector
10 Alarm lamp 11 Speaker

Inner Structure

This handheld monitor includes main board, SpO2 module, NIBP module, LCD, touch screen, speaker and
battery; and main board constituting a main control unit and power supply.

6
M850 Handheld Monitor service manual

SpO2 connector
NIBP connector
LCD Speaker

Main board NIBP module

Battery
SpO2 module

Accessories

For M860 handheld monitor, it’s compatible with different types SpO2 sensors and NIBP
cuffs, including Adult / Pediatric / Neonatal reusable or disposable SpO2 sensor; and
Adult/Pediatric/ Neonatal cuff.

Adult reusable SpO2 sensor (9pin ) Pediatric reusable SpO2 sensor (9pin)

Neonatal reusable SpO2 sensor (9pin) Adult soft reusable SpO2 sensor (9pin)
7
M850 Handheld Monitor service manual

Disposable SpO2 sensor (9pin) NIBP cuff(Adult / Pediatric / Neonatal)

8
M850 Handheld Monitor service manual

Testing

Power supply testing

a. Press the switch button, and test if the equipment starts normally.
b. Connect the unit to the power adapter, and test if the charging signal light is on or not.

SpO2 testing

a. Connect the SpO2 probe to the fingers of normal person and the SpO2 socket of the monitor;
b. Check whether if there are SpO2 waveforms and whether the waveforms are normal;
c. Verify whether the parameter value in the SpO2 parameter zone is between 96-99% and whether the Pulse
reading is between 50-120;
d. Unplug the SpO2 probe and the SpO2 testing is completed.

NIBP testing
a. Confirmed the cuff has been entirely deflated.

b. Tie the cuff to the upper arm or thigh of the normal person and connect the NIBP socket to the monitor, then
press the NIBP button to start measurement.
c. Verify whether the parameter value in the NIBP parameter zone.
d. Unplug the NIBP socket and the NIBP testing is completed.

Alarm lamb & Speaker testing

a. Press the turn-on button; observe whether the alarm lamb sparkles by red and yellow once as well as the speaker
sounds “Do” once.
b. Turn off the equipment; observe whether the alarm lamb sparkles by red once as well as the speaker sounds
“Do” once
c. Alarm lamb and speaker testing is complete.

9
M850 Handheld Monitor service manual

Maintenance and Cleaning

Introduction

Keep your equipment and accessories free of dust and dirt. To avoid damage to the equipment, follow
these rules:

1. Always dilute according the manufacturer’s instructions or use lowest possible concentration.

2. Do not immerse part of the equipment in the liquid.

3. Do not pour liquid onto the equipment or accessories.

4. Do not allow liquid to enter the case.

5. Never use abrasive materials (such as steel wool or silver polish), or erosive cleaners (such as acetone or
acetone-based cleaners).

 Warning: Be sure to shut down the system and disconnect all power cables from the outlets before
cleaning the equipment.

 Warning: For optimal performance, product service should be performed only by qualified service
personnel.

Caution: If you spill liquid onto the equipment or accessories, contact your service personnel or us.

Maintenance and Cleaning

Cleaning the Monitor


1. Common detergent and non-corrosive disinfectant used in hospital can be applied to clean monitor, however
you must be aware that many kinds of detergents must be diluted prior to utilization, and please use it according
to the instruction of detergent manufacturer.
2. Avoid the use of alcohols, amino or acetonyl detergent.
3. The enclosure and screen of monitor shall be free of dust, and they can be wiped with lint-free soft cloth or
sponge soaked in detergent. While cleaning, be careful and do not spill liquid onto the instrument and keep any
liquid out of it. When wiping the side panel of monitor, you must be especially careful to keep water out of all
kinds of cable and outlet on the panel.
4. Do not use abrasive material including wire brush or metal brightener during cleaning because this material will

10
M850 Handheld Monitor service manual

damage the panel and monitor screen.


5. Do not submerge the monitor in liquid.
6. While cable or plug of attachment accidentally gets wet, please rinse it with distilled water or deionized water
and dry it in the environment of temperature 40℃ to 80℃ for at least one hour.

Cleaning SpO2 Sensor


1. The casing of the sensor and light tube can be cleaned with swab or non-velvet soft cloth dipped with medical
alcohol.
2. The sensor cable can be cleaned or sterilized with Hydrogen Peroxide 3% or isopropyl alcohol 70%.
3. It is forbidden to put the monitor in high-pressure containers and put the sensor directly in liquid.

Cleaning NIBP cuff


1. Please regularly clean the product.
2. Remove cuff from connector and pull out airbag from sheath.
3. Submerge clean and soft medical gauze pad or other soft cleaning tools into fresh water or neutral soapy
water, and wring out surplus water from the submerged gauze then wipe airbag and pipe.
4. Wash the cuff sheath in the clean neutral soapy water.
5. After the sheath and airbag intensive drying, enclose airbag with cuff sheath and put into operation.

 Warning: Do not reuse or disinfect the disposable SpO2 sensor.

Disposal
Dispose of the monitor in accordance with local environment and waste disposal laws and regulations. For the
disposal of SpO2 sensor and NIBP cuff, follow local regulations regarding disposal of hospital waste.

11
M850 Handheld Monitor service manual

Menu Tree

Switch on the monitor, and then enter main menu to check the menus in details as below:

Main menu Patient info ID

Typ Adult / Pediatric / Neonate


e
Pace Yes / No

SpO2 Setup Alarm level High/ Media/ Low

Alarm limit

Speed 6.25, 12.5, 25 mm/s

Average Time 4, 8, 16 s

QRS Volume High/ Media/ Low /off

NIBP Setup Alarm level High/ Media/ Low

Alarm limit

Inflation

Unit mmHg/kPa

Measure mode STAT/Manual/Auto-1min/Auto-2min

Stop all measure

NIBP trend

System Brightness 1~5

12
M850 Handheld Monitor service manual

Alarm volume High / Media / Low

Auto-rotate On/ off

Version

Date & Time Setup

Set to Default

Alarm reset

Maintenance Module setup SpO2+NIBP


e

Language

Auto power off Off/10min/30min

DEMO On/off

Machine maintenance

Trouble shooting

In case the users or engineers of hospital have handled the instrument according to the following methods and
still unable to have the trouble fixed on they own, please timely notify company or agent and our professional
technicians will cater to your service.

Fault Resolution
1) SpO2 could not be determined
a. Check whether the LED in the SpO2 probe is twinkling with red light, if the LED is dark, SpO2 probe is out
of order, needs to be changed;
b. SpO2 sensor connection problem——Re-plug SpO2 probe
c. SpO2 communication interface break down——Change communication interface
d. SpO2 module break down——Replace the SpO2 module

2) NIBP malfunction
a. NIBP Air Leak or Loose Cuff——An internal valve, air hose, or the cuff is leaking air, check it and
replace. The cuff is not wrapped properly around the patient’s limb.
b. NIBP Cuff Type Error——The cuff type or the patient type is wrong.
13
M850 Handheld Monitor service manual

c. NIBP measurement can’t be start——Replace the NIBP module

3) Not display after switching on the monitor


a. Run out of battery——Replace with new batteries;
b. Switch button break down——Replace the switch button;
c. LCD break down—Replace a new LCD;
d. Main board breakdown——Replace the main board.

4) Touch screen is not working


a. Check if any damage on the Touch screen, if yes, replace a new touch screen;
b. Touch screen break down——Replace a new touch screen
c. Main board break down——Replace a new main board.

5) No volume of the monitor


a. Check if the setting of the monitor, set the QRS volume or alarm volume to High, media or low
b. Open the monitor ,and check if the speaker is well connected or not;
c. Speaker breakdown——Replace a new speaker;

6) Battery cannot be recharge


a. Battery break down——Replace the battery;
b. Charging device break down——Testing AC power cord, power adapter, charger is good, otherwise replace.
c. Main board break down——Replace the main board

Maintenance menu
Menu——System Setting——System Maintenance——Enter the password 785623, and then go to system
maintenance setting the relevant features:
Language: Chinese / English
Auto Power off: 10 min / 30 min / off
DEMO: On / Off

14
M850 Handheld Monitor service manual

Disassembly

Prepare
Tool: cross screw driver

Procedure:
1. Remove the screw and open the unit;

2. Unplug the cables, and then Remove the screw and then take out the SpO2 module;

SpO2 module

3. Unplug the LCD cable and touch screen cable, and remove the screws, and then take out the
main board;

15
M850 Handheld Monitor service manual

Touch
screen
connector

Main board

LCD
connector

4. Take out the LCD

Touch screen LCD

5. Take out the battery and remove the screws to take out the speaker form the rear case;

Speaker

Battery

16
M850 Handheld Monitor service manual

6. Remove the screws to take out the NIBP module and connector;

connector

NIBP module

7. Remove the screws to take out the SpO2 connector and NIBP connector;

SpO2 NIBP
connector connector

17
M850 Handheld Monitor service manual

Explosive view

No. Material No. Item No. Material No. Item


1 1.14.043-0010-00-1 Touch screen 2 1.19.33-000200-0-2 Front case
3 1.19.33-000206-0-3 Function Button 4 1.19.33-000205-0-1 On/Off button
5 1.14.043-0001-00-6 LCD 6 2.61.6800-01-00 Main board
7 2.00.0050-01-05 SpO2 module 8 1.12.06-37-0055-00 Battery
9 1.19.33-000201-0-1 Rear case 10 1.19.33-000210-0-1 Power indicator
11 1.19.33-000211-0-1 Alarm lamp 12 1.19.33-000210-0-1 Speaker fixing plate
13 1.16.21-000012-001 Speaker 14 2.61.6802-01-00 SpO2 connector
15 1.19.33-000215-0-1 Connector plate 16 2.31.0021-01-00 NIBP connector
17 2.00.0052-00-11 NIBP module

18
M850 Handheld Monitor service manual

Product name: Handheld Monitor


Product type: M860
Manufacturer: Guangdong Biolight Meditech Co., Ltd.
Address: Innovation First Road, Technology Innovation Coast, Jinding, 519085 Zhuhai, PEOPLE’S REPUBLIC
OF CHINA
Postcode: 519085

19

You might also like