Building Circuit Protection Devices PDF
Building Circuit Protection Devices PDF
Building Circuit Protection Devices PDF
Catalogue 2011
MCB
MCB Changeover
RCCB
RCBO
Distribution Board
Safety Ensured
Standard Electricals Ltd (SEL), a flagship company of the Rs 5500
Crores (US $ 1.2 Billion) professionally managed group QRG
Enterprises is a market leader in the field of low voltage electrical
distribution & consumer electrical products. The company has
carved a niche in the switchgear market by constantly creating
innovative solutions and upgrading the product range to meet the
ever-changing needs of the discerning customers.
SEL started its manufacturing operations with conventional
Rewirable Switch Fuse units over four decades ago.
The product range today includes highly sophisticated
domestic & industrial products such as MCBs, RCCBs, RCBOs,
Distribution Boards (DBs), MCCBs, Changeover Switches,
Switch Disconnector Fuses (SDFs), HRC Fuses, CFLs
etc.. All products are designed to comply with major
Indian & International Standards and are tested at CPRI/ERDA
Laboratories.
The quality control systems of the company have been audited
by BVQI and the company is certified for ISO 9001: 2000.
STANDARD brand of MCBs are CSA, CE, and KEMA marked & being
exported to many European & Middle-East Countries.
SEL emphasises on Research & Development which is the
lifeline of the company. The Company uses state-of-
the-art CAD/CAM for the entire stage of design and
development. It has complete in-house facilities for short circuit
testing upto 10kA and all related equipments for conducting electrical /
mechanical tests.
The company has its manufacturing plant in Haridwar (Uttarakhand),
with a work force of more than 500 people including 100 qualified
engineers.
STANDARD brand has a wide customer base through its
nationwide marketing network having offices in all major cities
in India with over 750 Authorised Dealers for effective sales &
services.
SEL products are now available internationally having
a strong export base. Its products are being exported
to the Middle East, South East Asian countries,
Malaysia, Singapore, Germany, U.K., South Africa, Kenya, Ghana,
Nigeria.
CONTENTS
Miniature Circuit Breaker (MCB) 6
Execution
SP, SPN, DP, TP, TPN & FP
Specification
IS / IEC : 60898-1
6
Electricity is an inseparable part of our daily lifestyle. In
residential, commercial and industrial sectors there are myriad
systems, equipments and sophisticated appliances that depend
on electrical energy. Uncontrolled electrical power can be
extremely dangerous. Overloads, crowded wiring, short-circuits
and all kinds of interruptions in electric supply can lead to
devastating losses, least of them being financial.
We at STANDARD are proud to be known and respected the
world over for our range of superior quality electrical control and
safety devices. Through these, we speak of our lasting concern
for safety, economy and productivity for our customers.
The latest product from STANDARD is 10kA MCB, is an advanced
Indian design of high performance, current limiting and switching
for control and protection of industrial, commercial & domestic
electrical sub circuits. It meets the latest specification IS / IEC :
60898-1 of B & C Characteristics.
The primary function of the MCB is to protect the installation
such as cable & other components from damage, resulting due to
overload & short-circuit fault. Under overload heating effect can
occur on cable. Protection in this respect is assured by matching
the cable rating to the current rating of MCB.
Under short-circuit condition, mechanical damage can occur
due to strong magnetic field caused by high current peaks
and overheating of cables on account of "exclusive let through
energy". The current limiting action of "MCB" ensures low value
of both peak current "cut off" and minimum let through energy.
Design
Latest & one of the best designed MCB.
Higher performance in a smaller package.
• MCBs conforms to the latest Standards IS / IEC : 60898-1 /
2002.
• These MCBs provide reliable protection to circuits against
overload & short-circuit ideal for industrial, commercial &
residential installations.
Certifications
ISI
Larger terminals
Dual termination facility for incoming side and can take wire upto
25sq. mm cross section. Wire may be of copper or aluminum.
Shock proof
Offer IP 20 degree of protection. All live parts are out of human
reach ensuring safety to user.
Longer life
Reduced electro magnetic stresses resulting in increased contact
life.
Flexibility
Can be mounted easily in any of the regular Distribution
Boards.
Energy saving
IS / IEC : 60898-1 have recognized the growing importance of
limiting power loss in Switchgear devices and stipulated max.
permissible power loss values per pole of MCB. MCB having
power loss figures of 50% lower watts than IS requirement.
Thus, 50% energy & cost saving by application.
7
PROTECTION UNLIMITED
CHARACTERISTIC CURVES
Time (sec.)
1.13 x In >1h 3xIn >0.1s
B Curve 10.00
1.45 x In <1h 5 x In <0.1s
‘D’ Curve: for protection of electrical circuits which causes high inrush
Voltage
Maximum
CURRENT LIMITING DESIGN Prospective
Fault
Current
Current
In a current limiting breaker, the tripping & arc control mechanism is so A Cut-off
Current
designed that under short circuit conditions, the contacts are physically
separated and the electrodynamic forces set up by fault current assist
the extinction in less than half cycle. B
The figure shows the current limiting effect of a circuit breakers. Fault
Traces for Voltage & Current 0 tX t1 t2
8
MINIATURE CIRCUIT BREAKER
TECHNICAL INFORMATION
MCB Isolator
Standard Conformity IS / IEC 60898-1 IS / IEC 60947 - 3
Type/Series B C D***
Rated Current (In) A 6 - 40* 0.5 - 63* 0.5 - 63* 40 - 125
Rated Voltage (ac) (Ue) V 240/415 240/415
Rated Frequency (f) Hz 50 50
Nos. of Poles (Execution) SP, SPN, DP, TP, TPN, FP ** SP, DP, TP,FP**
Rated Short Circuit kA 10 10 6 to 32 - 10KA
Breaking Capacity 40 to 63 - 4.5kA
Utilization Category Magnetic AC 22A in 40A & 63
(3-5)In (5-10)In (10-20)In
Release Setting AC 23A in 100A & 125A
Rated Insulation Voltage (Ui) V 690 690
Rated Impulse Voltage (Uimp) kV 4 4
Electrical / Mechanical
Endurance Endurance (No. of
operations)
20,000
Less than 32A 10,000 10000
More than 32A
Ambient Temperature (oC) -5 to +45
Terminal Capacity (Max) sq.mm 25 25
Vibration 3 5
Shock 40 mm free fail
Protection Class IP - 20
Installation Position Vertical / Horizontal
Mounting Clip on DIn Rail (35 mm x 7.5 mm)
Case & Cover Moulded, flame retardant thermoplastic material.
*Current Ratings - 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, ** SP Single Pole
40A, 50A, 63A DP Double Pole
*** D Type MCB are available on request TP Three Pole
TP + N Three Pole Neutral
FP Four Pole
DIMENSIONS (in mm)
17.7 35.4 53.1 70.8 60
44
45 36 84
9
MINIATURE CIRCUIT BREAKER
10
MINIATURE CIRCUIT BREAKER
Current Cat N o.
ating (Amps.)
R B-Curve C-Curve
0.5 - DSMSCTPF0X5
1 - DSMSCTPF001
2 - DSMSCTPF002
2.5 - DSMSCTPF2X5
3 - DSMSCTPF003
5 - DSMSCTPF005
6 - DSMSCTPF006
10 - DSMSCTPF010
16 - DSMSCTPF016
20 - DSMSCTPF020
25 - DSMSCTPF025
32 - DSMSCTPF032
40 - DSMSCTPF040
50 - DSMSCTPF050
63 - DSMSCTPF063
11
ISOLATOR
ISOLATOR
TECHNICAL SPECIFICATION-ISOLATOR
Range
40A, 63A, 100A and 125A
Execution
SP, DP, TP, & FP
Specification
IS / IEC: 60947-3
Rated Voltage
240V / 415V AC
Rated Frequency
50 Hz
Utilisation Category
AC 22A in 40A and 63A
AC 23A in 100A and 125A
Electrical Endurance
10000 operations
Mechanical Endurance
20000 operations
Terminal Capacity Flexible Solid
40A, 63A 16 sq.mm 25 sq.mm
100A, 125 A 35 sq.mm 50 sq.mm
12
ISOLATOR
13
MINIATURE CIRCUIT BREAKER
ACCESSORIES
AUXILLARY CONTACT
Standard Conformity
IS / IEC : 60947-1
Rated Current (In)
6A
Rated Voltage (Ue)
240 V ac
Contact Configuration
1 NO + 1 NC
2 NO + 2 NC
Utilization Category
AC 11
Electrical Endurance (nos. of operations)
10000
Terminal Capacity (max)
4mm2
Protection Class
IP - 20 as per IS : 2147 & IEC : 60529
Mounting
Left side of MCB (Factory assembled)
Standard Conformity
IS / IEC : 60947-3
Coil Consumption
6VA
Rated Voltage
(ac) (Ue) (dc) (Ue)
240V 48V, 24V, 12V
Frequency
50Hz
Operating Voltage range
70% - 110% of rated voltage
Electrical Endurance (nos. of ops)
10000
Terminal Capacity (max)
25mm2
Protection Class
IP - 20 as per IS-2147 & IEC-60529
Mounting
Right side of MCB
(Factory assembled)
14
MINIATURE CIRCUIT BREAKER
• To trip the Circuit Breaker through Shunt Trip Coil, 70% to Shunt trip Connection Digram
110% of the rated voltage is to be applied across D1 & D2 Outgoing D1 CoilTerminal
• The Shunt Trip coil is short time rated and it trip the breaker
instantaneously. (i.e., continuous duty not required)
1 3
2 4
Incoming D2 CoilTerminal
Incoming Connection
15
Range
MCB CHANGEOVER SWITCH
25A, 40A
Execution
Double Pole,
Four Pole
Specification
IS / IEC : 60947-3
16
MCB Changeover switch finds wide & varied applications in in-
dustries as well as in domestic sphere for use in low voltage
distribution circuits, wherever continuity of supply is necessary,
for switching to an alternate source of supply from main supply
and vice - versa.
They are switch disconnectors with independent manual opera-
tion, capable of making, carrying and breaking currents under
normal circuit conditions, which may include operating overload
condition and also carry currents under specified abnormal circuit
conditions such as those of short circuit for a specified time.
Features
• Compact construction
• Double break contacts
• Silver Cadmium Oxide contact tips
• Shrouded terminals
• Front operation with three stable positions I-O-II
• Centre position OFF
• Easy snap on DIN Rail mounting
• Can be mounted with other products viz. MCB, RCCB,
Isolator in Distribution Board
CONSTRUCTION
The entire switching mechanism along with the fixed and moving
contact assembly are housed in FR thermo plastic moulded case
/ cover, having high dielectric strength, excellent mechanical &
thermal properties.
The switching mechanism is double break type. The contact
tips are made of Silver Cadmium oxide for long electrical life,
sustained current carrying capacity and they ensure temperature
rise is within specified limits.
TECHNICAL INFORMATION
Standard Confirmity IS/IEC-60947-3
No. of Poles (Execution) : DP, FP
Rated Current (In) A : 25, 40
Rated Voltage (Ue) V : 240 AC / 415 AC
Rated Frequency Hz : 50
Rated insulation voltage V : 660
Dielectric Strength kV : 2.5
Rated impulse voltage kV : 4
Utilization Category : AC 21A
Ambient Temp. °C : -5 to +55
Mechanical life Nos. ops. : 10000
Electrical life Nos. ops. : 10000
Mounting : Standard DIN rail
Mounting Position : Vertical / Horizontal
Terminal Capacity sq. mm : 10
17
MCB CHANGEOVER SWITCH
Double Pole
1 3 5 7
2 4 6 8
18
MCB CHANGEOVER SWITCH
Four Pole
1 5 9 13
2 4 6 8 10 12 14 16
19
Range
16A - 63A
Execution
2 Pole, 4 Pole
Specification
IS 12640 - 1: 2008
IEC 61008 - 1
RCCB / ELCB
20
The flow of current through electrical facilities always involves
risks. Poorly insulated equipment, faulty wires and incorrect use
of an electrical device cause currents to flow through the wrong
path (i.e. through the insulation) to the earth. This current is
called ‘Leakage Current’.
Earth leakage is an electrical hazard and is responsible for
electrical shocks and fire risk. Earth leakage and its associated
hazard can be prevented by Residual Current Circuit Breaker
(RCCB), also popularly known as Earth Leakage Circuit Breaker
(ELCB).
Features
• Simple and Robust operating mechanism.
• Rotary handle with ON/OFF indication
• Dual termination for Bus Bar as well as cable connection
• Advance neutral
• Test button for regular inspection
• Positive contact indication
Range
16A - 63A
Sensitivity
30mA, 100mA, 300mA
Execution
Double Pole (DP)
Four Pole (FP)
Specification
IEC 61008-1/IS 12640 - 1:2000
Against Electrocution
The use of exposed, substandard, badly wired, wrongly connected
or damaged equipment as well as frayed or badly repaired cables
reduces the safety of an installation and increases the risk of
person receiving an electric shock.
Electrocution is a passage of current through human body, which
is dangerous. The flow of current through human body effects
vital functions.
1. Breathing
2. Heartbeat
A correctly chosen RCCB can detect small currents flowing to
earth and reduces the risk of electrocution. Effect of electric
current through human body has been well researched and
following chart summarizes the results:
Effect of electric current through human body has been
well researched and following chart summarizes the results
21
RCCB/ELCB
PROTECTION
Against Electrocution
The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables
reduces the safety of an installation and increases the risk of person receiving an electric shock.
Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital
functions.
1. Breathing
2. Heartbeat
A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current
through human body has been well researched and following chart summarizes the results.
Effect of electric current through human body has been well researched and following chart summarizes the results.
However, electrocution should not be viewed in terms of “current” Rated Tripping Current Maximum permissible
alone, but in terms of “contact voltage”. A person gets electrocuted of the RCD earth fault loop impedance in
by coming in contact with an object that has a different potential
from his/her own. The difference in potential causes the current to 10 mA 5,000
flow through the body. 30 mA 1,666
The human body has known limits: 100 mA 500
• Under normal dry conditions, voltage limit = 50V 300 mA 166
• In damp surroundings, voltage limit = 25V
Example
For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In
= 50/0.03 = 1,666
AGAINST FIRE
The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current
of less than 1 amp.The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A
correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting.
22
RCCB/ELCB
WORKING PRINCIPLE R
Y
conductors, i.e. the phases and the neutral, are passed through N
Earth
23
RCCB/ELCB
SELECTION
a b c1c2c3
30 mA : A 30 mA ELCB will provide a high degree of protection 10000
Time in milliseconds
body and the voltage across it. 500
200
WIRING DIAGRAM
1N 1 3 5N 1 3 5N
R R R
T T
T
2 4 6N 2 4 6N
2N
1 N
2 4 6 N 2 4 6 N
The Standard range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral),
however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the
RCCB.
24
RCCB/ELCB
68.0
67.8
71.0
36.0 60.0 60.0
36.0
45.0
84.5
36.0
45.0
43.5
25
RCCB/ELCB
26
RCCB/ELCB
69.5
44.0
30.5 36.0
72.0
45.0
36.0 87.5 87.5
27
Range
6A, 10A, 16A, 20A, 25A, 32A & 40A
Sensitivity
30mA, 100mA, 300mA
Execution
Single Pole with neutral (SPN)
Triple Pole with neutral (TPN)
Specification
IS:12640 Part2: 2008, IEC 61009-1,
BSEN:61009-1
RCBO
28
Standard New RCBO is a single composite device which provides
protection against over currents and earth leakage faults in the
same width and profile as that of a standard MCB. It is designed
for use in domestic, commercial and industrial distribution sys-
tems at the most downstream circuit for ensuring high degree of
protection to the user for a particular circuit. In normal use, it is
safe to use and free of to user as well as to environment.
Features
• Pulsating dc protection - Type A
• Discrimination using time delay - Type S RCBO
• Controlled response VD RCBO (Electronic)
• Protection in case of loss of supply neutral in SPN RCBO only
• Enhanced immunity to nuisance tripping
• Positive contact indication: Red for ON , Green for OFF
• Short circuit breaking capacity 10 kA.
• Large terminal capacity: RCBOs have 35 mm2 for cool running
while in operation.
• Protection in case of loss of supply neutral: Even in event of
loss of supply neutral, Standard RCBO provides protection
against earth faults . The Functional Earth (FE) white color
wire connected to earth provides this protection.
• Controlled response & immunity to nuisance tripping: The
trip level and the response time of the Standard VD (Voltage
Dependent) RCBO using electronic circuit is set to very
precise values and thereby provide greater immunity to
nuisance tripping that can be caused by mains borne noise,
surge voltages, lighting surges, reactive loads, mains filters,
etc.
• Neutral to earth faults: A connection that occurs between
N and E on the load side of any RCBO will impact on its
performance and cause the trip level to increase. In the case
of a N - E fault, the user may have no way of knowing that this
fault exists and that the RCBO has been desensitised. Under
this condition, the Standard VD RCBO provides a far greater
level of protection than a normal VI (Voltage Independent)
RCBO.
Energy limiting
29
RCBO
30
RCBO
Time Current Characteristics C Curve Residual Current Tripping Characteristics (General Type)
10000.00 1000.00
1000.00
100.00
100.00
10.00
Time (sec)
Time(sec)
10.00
1.00
1.00
0.10
0.10
0.01
0.01 0.01 1 10 100 1000 10000
1 10 100
Multiples of Reted Current Multiples of Reted Residual Current in I∆n mA
6.8
87.5
36 45 125
36 45
6.8
43.5
43.5 68.4
74.5
68.4
70.6
31
Range
Single Phase & Three Phase
Execution
DISTRIBUTION BOARDS
Specification
IS : 13032 / IS : 8623
32
Standard make Smart Distribution Boards provides flexibility
and a systematic approach to ever increasing need for effective
methods of the electrical distributions in domestic, commercial
and industrial application. Standard Smart distribution boards
have been specially designed to meet all the technical require-
ments and ensure the distribution boxes blend with the decor of
the place of the installation.
The Smart distribution boards with their features and their range
offer a compact, practical and economic solution to any electri-
cal network in residential / commercial complexes, industries
etc. having single phase or three phase connections. The Smart
distribution board is not merely an enclosure but a complete
system in itself comprising of ETP Copper bus bar, brass neutral
link, earth link, earthing studs, and interconnection wires for ef-
fective distribution of current.
33
DISTRIBUTION BOARDS
RANGE
Reversible door
34
DISTRIBUTION BOARDS
35
DISTRIBUTION BOARDS
C
(fixing center)
B 65
36
DISTRIBUTION BOARDS
B
C
A
8 687 669 593 6 No. 1 Nos.
12 796 778 702 6 No. 1 Nos.
270.0 113.0
(fixing center)
350.0 3.5
367.0
37
SQVE SERIES - SPN DOUBLE DOOR DISTRIBUTION BOARD
84.5
8
(Ø25) (Ø31) (Ø25) (Ø31) Side)
4 125 175 197 172 3 - 3 - 1
A
6 151 211 232 166 2 1 2 1 1 3
8 187 247 268 166 2 2 2 2 1 B
244
D
38
SQVE SERIES - TPN DOUBLE DOOR DISTRIBUTION BOARD
8
Dimensions Knockout holes (Ø31)
Ways
A B C Top Bottom Side (Each Side)
97.5
4 196 251 272 3 3 1
6 268 323 344 2 2 1 A
3
39
PREWIRED DISTRIBUTION BOARD - SPN SINGLE DOOR
372
B (fixing center) 65
40
PREWIRED DISTRIBUTION BOARD - SPN DOUBLE DOOR
372
41
PREWIRED DISTRIBUTION BOARD - TPN SINGLE DOOR
672
B (fixing center) 65
42
PREWIRED DISTRIBUTION BOARD - TPN DOUBLE DOOR
96
Ways Side (Each
Thickness A B C Top Bottom
Side) A
4 1.2 389 315 410 5 5 0
6 1.2 442 349 445 7 7 0
8 1.2 460 387 482 9 9 0
12 1.2 605 534 624 13 13 0
605 (Fixing center)
702
675
43
DISTRIBUTION BOARDS
B
C
A
8 687 669 593 6 Nos. 1 Nos.
12 796 778 702 6 Nos. 1 Nos.
270.0 113.0
(fixing center)
350.0 3.5
367.0
88
C
A E
480
44
DISTRIBUTION BOARDS
375
450
460
2 + 12 395 320 405 7 7 6
A
B
3
103
11
PHASE SELECTOR (HORIZONTAL) DBS - 4 QUADRANT DESIGN (With Rotary Switches & Wires)
45
DISTRIBUTION BOARDS
4 40A DSDSNVDRZ04040
4 63 A DSDSNVDRZ04063
6 40 A DSDSNVDRZ06040
6 63 A DSDSNVDRZ06063
8 40 A DSDSNVDRZ08040
8 63 A DSDSNVDRZ08063
595
670
680
4 8+12 40A 333 323 248 9 8 9 8 3
4 8+12 63A 333 323 248 9 8 9 8 3
6 8+18 40A 405 395 320 9 8 9 8 3
6 8+18 63A 405 395 320 9 8 9 8 3
A
8 8+24 40A 405 395 320 9 8 9 8 3
B
8 8+24 63A 405 395 320 9 8 9 8 3 C
3
105
11
7 SEGMENT DBs - IP 42 PROTECTION
550
650
680
550
650
A A
B B
102
102
8
22 C 22 22 C 22
46
DISTRIBUTION BOARDS
(fixing center)
(fixing center)
2 118 104 49 189 175 1Nos. Ø26 1Nos. Ø26
107.0
125.0
D
E
3 118 104 49 189 175 1Nos. Ø26 1Nos. Ø26
4 136 122 67 189 175 1Nos. Ø26 1Nos. Ø26
C C 53.5
(fixing center) (fixing center) 63.0
B B (KSS-1+N / 2+N/ 3 /4+N)
A A
(KSS-1+N) (KSS-2+N/ 3+N / 4+N)
B C
47
PLUG AND SOCKET ENCLOSURES
(fixing center)
TP
254.0
278.0
L
20 KSPS/SP 133 162 1 No. f 26 1 No. f 26
20 KSPS/TP 123 287 1 No. f 26 1 No. f 26
30 KSPS/TP 123 287 1 No. f 26 1 No. f 26
63.0
W
Earth terminal
110.0
152.0
SPN
L
56.0
W
63.0
ACCESSORIES
• Neutral Bar/Earth Bar
• DIN Channel
• Bus Bar with PVC Sleeve
• Blanking Plate 1/2
CUSTOMIZED DBs
• Prewired DB
• Dbs with extended loose wire box
• Meter Box (1 Phase & 3 Phase)
FEATURES
• The DB can be supplied with neutral and earth bars if so required
• The enclosures are made of special grade CRCA steel sheet manufactured with latest CNC punch and brake presses to attain higher
degree of perfection.
• Adequate number of knockouts at the end plates are provided for ease of wiring.
• Din rails are provided for snap mounting of MCBs/RCCBs.
• The DB is suitable for IP 40 degree of protection.
48
IP RATINGS
The IP (International Protection) rating given to an enclosure states the degree of protection it offers by means of two digits. A
summary of these is shown below, for a more detaileddefition, see IEC 529 : 1989, BS EN 60529 : 1992.
FIRST DIGIT
Protection against solid foreign objects and access to hazardous parts.The first digit covers protection against penetration by solid
objects, which includes hands and tools such as screwdrivers.
At the lowest of seven levels, 0, no protection is offered, either of the equipment itself from damage by intrusion or of a person
contacting live or moving parts. At the highest, there shall be no entry of dust.
SECOND DIGIT
Protection against ingress of water. The second digit covers the degree of protection against the entry of water, on a progressive
scale. for example, number 1 indicates that dripping water shall have no harmful effect, and number 6, that water projected in
powerfuljets against the enclosure from any direction shall have no harmful effects.
No Protection 0 No Protection 0
The letter X can be used in place of the first or second digit to indicate that tests have either not been made or are
not applicable.
49
CATEGORY OF DUTY
The category of duty defines the basic type of circuit and AC22/DC22 Switching of mixed resistive / inductive
switching capability of the device, and loads, including moderate overloads.
selection should be made accordingly.
Suitable for mixed resistive / inductive
Utilisation Category Typical Applications loads. Devices can switch 300% of its
rated current under fault conditions.
AC20/DC20 Connecting and disconnecting under
no-load. AC23/DC23 Switching of highly inductive loads.
Devices complying with AC23/DC23 are
Assumes all switching operations are
provided mainly as back-up to other means
carried out by other capable devices before
of switching. e.g. contacts. In the event
this device is operated.
of failure of functional devices, an AC23
AC21/DC21 Switching of resistive loads including / DC23 type device can safety interrupt a
moderate overloads. stalled motor current. Where devices are
the only means of controlling individual
Suitable for purely resistive type loads
motors, they should comply with the
devices can switch 150% of its rated
requirements of appendix A of the standard.
current under fault conditions
(IEC 60947-3)
e.g. Uimp = 8kV, Tested @8kV peak (Icw) is the current the circuit breaker
with will withstand for the maximum short-
time delay time. Preferred times are
1.2/50m (ms)S impulse wave
0.05, 0.1, 0.25, 0.5 and 1.0 second.
In = Rated Current
50
REGIONAL BRANCH OFFICES
NORTH - REGIONAL OFFICE : Delhi : QRG Towers, 2D, Sector-126, Expressway, Noida-201304
Noida : Tel: 0120-4771000, Fax: 0120-4772000
Chandigarh : Tel: 0172-4232400 -401, Fax: 0172-4232403,
Dehradun : Tel: 0135-2521025, 2521552
Haryana : Tel: 91-120 2477848 / 853, Fax: 0120-2583904
Noida : Tel: 0120-3055609 / 3055610, Fax: 0120-3055611
Ludhiana : Tel: 0161-4676001 / 6024, Fax: 0161-46766007
Jammu : Tel:0191-2490424, Fax: 0191-2490405
Jaipur : Tel: 0141-3988210, Fax: 0141-2389024
Lucknow : Tel: 0522-2201032, 2200938
Kanpur : Tel: Airtel: 09935533751/52/53, 0512-2690128/129/130, Fax: 0512-2692800
EAST - REGIONAL OFFICE : Kolkata : ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700 001
Kolkata : Tel: 033-40129851/52, Fax: 033-40127339
Bhubaneshwar : Tel: 0674-2598104, 2598105, 2598106, Fax: 0674-2598107
Guwahati : Tel: 0361-2134521, 2458923, Fax: 0361-2460355
Siliguri : Tel: 0353-2525907-3290402 (RIM)
Jamshedpur : Tel: 0657-6542492, 09234369436
Patna : Tel: 0612-3244218, 2655519, Telefax: 0612-2655518
WEST - REGIONAL OFFICE : Mumbai : 302, Boston House, 3rd Floor Suren Road, CTS No. 260/261, Andheri
(E), Mumbai-400 093
Mumbai : Tel: 022-67298600-603
Ahmedabad : Tel: 079-40061111, 40060738-740, Fax: 079-40060741
Indore : Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626
Rajkot : Tel: 0281 3013289 / 3013290
Nagpur : Tel: 0712-2224132, 2222692, 2222029
Pune : Tel: 020-64016413/14
Raipur : Tel: 0771-4243400 / 01, Telefax: 0771-4243402
Surat : Telefax: 0261-2350137
SOUTH - REGIONAL OFFICE : Chennai : Block – 1, A & D Wing, Shakthi Towers, 7th Floor, 766, Annna Salai,
Chennai-600 002
Chennai : Tel: 044-28526941-44, Fax: 044-28524326
Bangalore : Tel: 080-39882100, 30515801 / 2 / 3 /4, Fax: 080-30515804
Coimbatore : Telefax: 0422-2305767, 2306199, 2305199
Hyderabad : Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Fax: 040-27533211
Kochi : Tel: 0484-4099000, 2393165, 2393068, Fax: 0484-2393170
Vishakapatnam : Tel: 0891-6514339, Fax: 0891-2522547
REPRESENTATIVE OFFICES
• Goa • Solapur • Gwalior • Jabalpur • Hubli • Davanagere • Gulbarga • Mysore • Trichy • Kathmandu • Sambalpur
• Jalandhar • Bhopal • Calicut • Madurai • Trivandrum
STANDARD ELECTRICAL LIMITED
Corporate Office: QRG Towers, 2D, Sector -126, Expressway, Noida - 201 304 (UP),
Ph. +91-120-4771000, India E-mail: standard.ho@sel.co.in
Consumer Care No.: 1800 11 0303 (Toll Free), 011-41 66 0303 (Landline), 1800 103 1313 (All connections)
Registered Office: 1/7, Ram Kishore Road, Civil Lines, Delhi - 110054
Visit us at : www.sel.co.in
For International Trade Enquires, please E-mail to: export.sel@sel.co.in