Professional Documents
Culture Documents
Linear Position Sensing - en PDF
Linear Position Sensing - en PDF
Industrial Identification
Object Detection
Accessories
Linear Position Sensing and Measurement
The appropriate measuring principle for the optimal solution
0 mm 48000 mm
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Tel. +49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de
www.balluff.com 3
Linear Position Sensing and
Measurement
Position or distance sensors
Balluff position measurement – the right solution for you Implement the optimum solution using the appropriate
Balluff position measurement offers efficient individual solutions. With measuring principle
very diverse operating principles for distances from 1 to 48,000 mm In order to be able to offer the optimum solution for specific measur-
and resolutions from 1 to 100 μm. From position detection to dis- ing tasks, Balluff has built up a comprehensive portfolio of position
tance measurement. measuring systems. These ensure that the solution not only works
Simply pick the system that's right for your specific requirements. technically, but also functions reliably and is both flexible and cost-
This way Balluff superior position measurement technology increases oriented. From eight different position measurement principles, you
your added value. can individually choose the solution for your application that is best
Robust industrial Balluff position measurement technology is accu- from a technical and economical perspective.
rate, reliable, non-contact, and wear-free. Balluff position measure-
ment brings out the best from your machines.
Equipped for the future! ■ Greater flexibility through full range of sensing principles
■ Extremely flexible ■ Greater efficiency with optimized solutions
■ Product changes using keyboard ■ Superior position measurement technology for increased
■ Longer cycle times productivity
■ Increased availability
■ Short set-up times The perfect solution for your application!
■ Downtimes prevented From the Balluff full-range assortment of position measurement
■ Greater degree of automation technology, we can work out the most economical and technically
are just some of the requirements designers and developers must appropriate solution for you.
fulfill for future machine generations.
Expert application consultation:
Phone: +49 7158 173-370 or +49 7158 173-777
tsm@balluff.de or
service@balluff.de
Magnetically Coded Position and Angle Measurement System BML – for high accuracy and long lengths
With position sensors, the position-giving element With distance sensors, the position-giving target can be any
or target is usually a position encoder that is part of the system. object.
However, in accordance with the distance sensor principle, the
function or quality of the measurement depends on the kind of
material or surface properties of the target.
Example: Example:
With magnetostrictive micropulse position measuring systems, With inductive distance sensors, the maximum measurement
the position-giving element is the position encoder, which has path depends on the target material used, and with optical
permanent magnets integrated into it, and which is attached to sensors, the function depends on the surface properties of the
the part that is moved. object or target.
Position Distance
measurement measurement
See page 6 See page 8
www.balluff.com 5
Linear Position Sensing and Position
Measurement measurement
Configuring the position measuring system
Length
Interface
3 Select the interface appropriate for the controller or electronic evaluation unit.
Measuring principle
Example:
Accuracy class "2-1" Basic
Typical value 2 (<10 μm), with the trend to 1 (1 μm) information
■ Technical data
Accuracy Class ■ Housing dimensions
< 1 μm 1 ■ Ambient condition
< 10 μm 2 ■ Mechanical features
< 50 μm 3 ■ Approvals
< 100 μm 4 ■ Ordering code
< 500 μm 5 ■ Accessories
< 1 mm 6 You can find this in
< 5 mm 7 the chapter devoted to
< 100 mm 8 the selected series.
Digital square-wave,
Analog, digital SSI, Analog, digital SSI,
SIN/COS 1 Vpp, analog Analog, digital
fieldbus, Ethernet fieldbus, Ethernet
SSI, BiSS
Magnetoelectric
Magnetostrictive Magnetostrictive Inductive Inductive
scanning
www.balluff.com 7
Linear Position Sensing and Distance
Measurement measurement
Configuring the distance measurement
system
Length
Interface
3 Select the interface appropriate for the controller or electronic evaluation unit.
Measuring principle
Example:
Accuracy class "2-1"
Typical value 2 (<10 μm), with the trend to 1 (1 μm)
Photoelectric,
Ultrasound, echo-travel
light travel time or Inductive Capacitive
time measurement
triangulation
www.balluff.com 9
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
10
Magnetically Coded
Position and Angle Measurement System
Contents
S1H series 18
S1F series 26
S2B/S2E/S1C series 34
Accessories 48
www.balluff.com 11
Magnetically Coded
Position and Angle Measurement System
Applications
Successfully used for years for to point mirrors towards the sun with
high accuracy. With BML you achieve the best energy efficiency in
concentrated solar power plants and parabolic trough power plants.
The BML enables ultimate control dynamics and high gain factors
by means of smallest dimensions and high accuracy. Position with
higher speeds and best precision.
Magnetically
coded posi-
tion and angle
measurement
system
Applications
Product
overview
Function
principle
S1H series
S1F series
S2B/S2E/S1C
series
Accessories
Universal milling machines use magnetically coded position and
Basic
angle measurement systems BML for accurate positioning of the x, Information and
y, and z axes. Definitions
www.balluff.com 13
Magnetically Coded High precision and
Position and Angle Measurement System extended lengths
Product overvie
System accuracy ±7 μm ±7 μm
Interfaces
Absolute SSI ■ ■
Absolute BiSS-C ■ ■
From page 18 18
Magnetically
coded posi-
tion and angle
measurement
system
Applications
Product
overview
Function
principle
S1F series
1...10 μm 5 to 50 μm 5 to 50 μm 100 to 2000 μm
S2B/S2E/S1C
series
±10 μm ±10 μm ±50 μm ±100 μm ±100 μm
Accessories
0.1...0.35 mm 0.1...0.35 mm 0.1...2 mm 0.1...2 mm 0.1...2 mm
Basic
0...48 m 0...48 m 0...48 m 0...48 m 0...48 m Information and
Definitions
■ ■ ■ ■ ■
■ ■ ■
■ ■ ■
26 26 34 34 34
www.balluff.com 15
Magnetically Coded
Position and Angle Measurement System
Function principle
Magnetically coded systems Displacement sensors with a magnetically encoded tape are very
are highly accurate robust and operate highly accurately and particularly fast as a
and real-time-capable measuring system. Resolution is down to 1 μm. Accuracy degrees
of ±7 μm can be achieved. The BML has no trouble with abso-
lute measurement of travel speeds up to 5 m/s and incremental
measurement up to 20 m/s. The absolute position values can be
clocked with up to 10 MHz. The measured position value is available
in fractions of microseconds. The controller receives the incremental
position signal in real time.
Non-contact and highly In addition to the high accuracy and real-time capability, the BiSS
robust, even for applications interface allows for bidirectional communication including signal error
in rough conditions detection. Since the measuring system operates magnetically, unlike
optical systems it is highly immune to contamination such as oil,
swarf, or dust and does not require encapsulation. Unlike with induc-
tive systems, with the BML, metal swarf merely causes attenuation
and does not register as a measurement variable. These properties
make it excellently suited for use in harsh or dusty industrial environ-
ments.
S1F series
S2B/S2E/S1C
Cosine sensor
series
Sine sensor
Accessories
Basic
Information and
Customizing Do you have a very specific application? Definitions
Simply contact us! We offer you not just the standard product line,
but also customized solutions. Some examples:
■ Higher resolutions
■ Other interpolation factors
■ Higher travel speeds
■ Larger read distances
■ Special cables/plugs
■ Special tape encodings
■ Special designs/hubs
Linear
+ +
Rotary
www.balluff.com 17
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
S1H series
With the S1H sensor series, the magnetically coded position and
angle measurement system BML provides high-resolution systems in
robust metal housings.
18
S1H Series
Contents
S1H
General data 20
Applications 21
SSI interface, BiSS-C interface 22
Tape, accessories 24
Digital display, CAM controller 25
www.balluff.com 19
S1H Series 1 μm absolute
General data
Tape
Page 24
Digital display
Page 24
Connection cables
Page 24
Features
■ Absolute measuring system
■ Additional sin/cos analog signal for fast
control applications
■ ±7 μm system accuracy
■ 1 μm resolution
■ Smallest design
■ Rugged metal housing
■ Mounted parallel or perpendicular to tape
Ultrasonic welding
Exact position feedback for perfect results. By means of direct
absolute measurement on the load, inaccuracies and tolerance shifts
are reliably eliminated.
S1F series
S2B/S2E/S1C
series
Accessories
Basic
Information and
Definitions
Quickly holds the welding tool on point and with millimeter precision.
www.balluff.com 21
S1H Series 1 μm absolute
SSI interface, BiSS-C interface
SSI interface
Synchronous serial data transmission suitable for controllers from
different manufacturers.
Reliable signal transmission, even with cable lengths of up to 400 m
between controller and transducer. This is guaranteed by the espe-
cially interference-proof RS485/422 differential drivers and receivers.
Any interference signals are effectively suppressed. SSIn Clock burst
The standard BML is factory-configured with the following settings
for the position output, which cannot be modified later: T Clk tm
■ BML-S1H_-S6_C-M2A...: 16-bit, Clk
1 2 3 4 5 n n+1
■ BML-S1H_-S6_C-M2C...: 18-bit,
■ Binary or Gray-coded
Data
■ Rising or falling MSB LSB
BiSS-C interface
BiSS-C is a synchronous serial data transmitter and suitable for In addition to the SSI or BiSS signal, an analog real-time signal sin/cos
controllers from different manufacturers. 1 Vpp is output for highly dynamic control applications.
Unlike SSI, the data transmission is bidirectional. In BiSS-C mode,
settings can be (continuously) configured on the sensor head without Additional analog real-time signal sin/cos 1 Vss
interrupting the sensor data.
BiSS-C supports CRC, warnings and error messages.
B (cos)
1 Vpp μm
A (sin)
Magnetically
coded posi-
tion and angle
measurement
Series BML-S1H... system
Output signal Absolute: SSI or BiSS-C, additional analog signal sin/cos 1 Vss
Data format 16-bit (BML-S1H...-M3AA-...) or 18-bit (BML-S1H...-M2CA-...) S1H series
Resolution 1/1.024 μm per LSB General data
Part number BML-S1H_-_6_C-M3_A-DO-KA00,3-S284 Applications
Repeat accuracy ±1 increment SSI interface,
BiSS-C interface
Overall system accuracy ±7 μm Tape, accessories
Supply voltage 5 V ±5% Digital display,
Current consumption at 5 V operating voltage < 50 mA + Controller current consumption, at 120 Ω load resistance CAM controller
Max. read distance sensor/tape 0.35 mm (without cover strip)
S1F series
Max. measuring length 64 mm (...-M3AA-...) or 256 mm (...-M3CA-...)
Pole pitch, analog track 1 mm
S2B/S2E/S1C
Max. traverse speed 5 m/s (absolute) series
Measurement rate for SSI fSTANDARD = 50 kHz
Operating temperature –20...+80 °C Accessories
Storage temperature –30...+85 °C
Housing material Aluminum Basic
Information and
Degree of protection IP 67 Definitions
All data applies in conjunction with tape BML-M02-A33... (see page 24)
~49
Sensor head R5
3
14.5
M12
2×M4
13
Ø max. 5.2
12 6 14
40
Active (Representation
Ordering example: sensor head measurement without plug)
surface
BML-S1H_-_6_C-M3_A-D0-KA00,3-S284
Approach
direction Interface Coding Length coding Connection
Preferred models
■ BML-S1H1-S6QC-M3CA-D0-KA00,3-S284 (BML0393)
Approach direction parallel to the tape, SSI interface, rising binary code, 256 series length coding, pigtail 0.3 m with M12 plug
■ BML-S1H2-S6QC-M3CA-D0-KA00,3-S284 (BML0394)
Approach direction perpendicular to the tape, SSI interface, rising binary code, 256 series length coding, pigtail 0.3 m with M12 plug
Attention!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 23
S1H Series
Tape, accessories
64
BML039J
10+0.2
mastertrack
90±2 1.55±0.1
BML039K 256
10+0.2
mastertrack
280±2 1.55±0.1
~44
M12x1
Ø14.5
Magnetically
coded position
and angle
measurement
system
S1H series
General
data
Applications
SSI interface,
BiSS-C
interface
Series BDD-AM 10-1-SSD BDD-CC 08-1-SSD Tape, acces-
Digital display CAM controller sories
SSI interface SSI interface Digital display,
CAM controller
Ordering code BAE0069 BAE006F
Part number BDD-AM 10-1-SSD BDD-CC 08-1-SSD S1F series
Features ■ 7 1/2-digit display with leading sign ■ 8 programmable outputs
■ LED display, 14 mm-high red ■ 8 directional switching points possible S2B/S2E/S1C
7-segment digits ■ LED display, six 14-mm high red series
www.balluff.com 25
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
S1F series
With the S1F sensor heads, the magnetically coded position and
angle measurement system BML provides high-resolution designs
in robust metal housings. They also detect reference points on the
tape. The S1F series can be used either parallel or perpendicular.
The S1F series has an extremely compact design and is therefore
easy to integrate in systems with restricted installation space.
26
S1F Series
Contents
S1F
General data 28
Magnetic tape 30
Magnet rings 31
Technical selection guide 32
www.ba
www.balluff.com
b llllufff.com 27
S1F Series
General data
Magnet Rings
Page 31
Counter-Displays
C t Di l
Tape
Page 50
Page 30
Approach Min.
direction Resolution Reference signal Edge separation Connection
Preferred models
■ BML-S1F1-A62Z-M310-90-KA05 (BML02J1):
Installed parallel to tape, analog output sin/cos, with reference signal, 5 m cable
■ BML-S1F1-Q61D-M310-F0-KA05 (BML001A):
Installed parallel to tape, RS422 digital signal, with reference signal, 5-m cable, resolution 1 μm,
edge separation 0.48 μs, max. travel speed 1 m/s
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
Series BML-S1F_-Q... BML-S1F_-A...
Output signal Digital square-wave signals RS422 Sinusoidal analog signals sin/cos S1F series
Resolution 1 μm, 2 μm, 5 μm or 10 μm processing-dependent General data
Part number BML-S1F_-Q61_-M3_ 0-_0-_ _ _ _ BML-S1F_-A62Z-M3_ 0-90-_ _ _ _ Magnetic tape
Output voltage (A/B/Z) RS422 to DIN 66259 1 Vpp Magnet Rings
Overall system accuracy ±10 μm ±10 μm Technical
selection guide
Supply voltage 5 V ±5% 5 V ±5%
Current consumption at 5 V operating < 50 mA + current consumption of the < 50 mA + current consumption of the S2B/S2E/S1C
voltage controller (depending on internal resistance) controller (depending on internal resistance) series
Max. read distance sensor/tape 0.35 mm 0.35 mm
Accessories
Max. traverse speed 20 m/s 20 m/s
Operating temperature –20...+80 °C –20...+80 °C
Basic
Housing material Al Al Information and
Degree of protection IP 67 IP 67 Definitions
½
½
½
½
Signal period
360° el.
B (cos)
1 Vpp μm
Edge separation
Reference pulse A (sin)
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 29
S1F Series
Magnetic tape
S1F...
27 8
Reference point
Accuracy
Design class Cover strip Length in cm Reference point positions
02 1.55 mm thick, 4 8 μm, 3 With cover Order length, R0000 None or pole-periodic
with adhesive strip overall accuracy strip (thickness max.
03 1.35 mm thick, ±10 μm 0.15 mm) 4800 = 48 m Rxxxx/ Position of
without adhesive 5 18 μm, 0 18 μm, 0000 1 reference point in cm
strip overall accuracy overall accu-
±20 μm racy ±20 μm Rxxxx/ Position of no more than
yyyy 2 reference points in cm
* Fixed-periodic reference point only for BML-M02-I34... C0006/ Fixed-periodic* all yyyy cm,
yyyy 0002, 0005, 0010, 0020
BML-M02-I3_-A0-T_ _ _ _-R0000
Flush
Magnetic tape
1.35±0.1 mm
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
S1F series
General data
Magnetic tape
Series Sensor family F Sensor family F Sensor family F
Magnet Rings
Ordering code BML002K BML01KM BML01EW Technical
Part number BML-M20-I30-A0-M072/054-R0 BML-M31-I30-A0-M075/060-R0 BML-M30-I30-A0-M122/090-R0 selection guide
Number of poles 228 238 384
Pole width 1 mm 1 mm 1 mm S2B/S2E/S1C
series
With reference mark No No No
Material Hard ferrite Elastomer on steel ring with Elastomer on steel ring with Accessories
fit H7 fit H7
Basic
Information and
Definitions
75.4
72
54
60
122
90
7 10
10
www.balluff.com 31
S1F Series
Technical selection guide
60 × max. travel speed (m/s) If the magnet ring diameter is 72 mm = 0.072 m, a speed of
Max. speed (rpm) =
π × magnet ring diameter (m) 783 rpm can be achieved according to the formula.
With consideration for the reduced value, the speed should not
exceed 705 rpm.
www.balluff.com 33
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
S2B/S2E/S1C series
With the S2B/S2E/S1C sensor heads, the magnetically coded posi-
tion and angle measurement system BML provides three systems for
optimum adaptation to your measuring task.
Resolution and accuracy can be appropriately selected depending
on the application. Integration of reference points is also possible.
All three systems have a compact design and the same dimensions
throughout the series, making them extremely versatile to integrate.
34
S2B/S2E/S1C Series
Contents
S2B/S2E
General data 36
Magnetic tape 38
Magnet rings 39
Technical selection guide 41
S1C
General data 42
Magnetic tape 44
Magnet rings 45
Technical selection guide 47
www.balluff.com 35
Magnetically
S2B/S2E coded position and angle measure-
Series
ment system
General data
S2B/S2E
?
Tape
Page 38
C t Di l
Counter-Displays
Page 50
Magnet Rings
Page 39
Features
■ 5 μm resolution
■ System accuracy to ±50 μm
■ High repeat accuracy ±1 increment System selection
■ 20 m/s maximum travel speed Relationship between resolution, edge separation and speed
■ Digital square-wave signals RS422 or 10 to 30 V Selection guide, see page 41
■ Two freely positionable limit switches
■ Reference signal
■ LED display for reference signal
Min.
Operating Output edge
voltage voltage Resolution Reference signal Limit switch separation Connection
Preferred models
■ BML-S2B0-Q53F-M410-D0-KA05 (BML0211)
Digital signal, 10 to 30 V, with reference signal, 5 m cable, resolution 5 μm, edge separation 0.12 μs, max. travel speed 20 m/s
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
S1F series
Series BML-S2B0-... BML-S2E0-...
Output signal Digital square-wave signals Digital square-wave signals S2B/S2E series
Resolution 5 μm, 10 μm, 25 μm or 50 μm 5 μm, 10 μm, 25 μm or 50 μm General data
Part number BML-S2B0-Q_ _ _-M4_ _-_0-_ _ _ _ BML-S2E0-Q_ _ _-M4_ _-_0-_ _ _ _ Magnetic tape
Output voltage (A/B/Z) RS422 to DIN 66259 or same as RS422 to DIN 66259 or same as Magnet Rings
operating voltage 10...30 V (without A/B/Z) operating voltage 10...30 V (without A/B/Z) Technical
selection guide
Overall system accuracy ±50 μm ±100 μm
Supply voltage 10...30 V or 5 V ±5% 10...30 V or 5 V ±5% S1C series
Current consumption at < 50 mA + current consumption of the < 50 mA + current consumption of the General data
5 V supply voltage controller (depending on internal resistance) controller (depending on internal resistance) Magnetic tape
Current consumption at < 40 mA + current consumption of the < 40 mA + current consumption of the Magnet Rings
10 to 30 V supply voltage controller (depending on internal resistance) controller (depending on internal resistance) Technical
selection guide
Max. read distance sensor/tape 2 mm 2 mm
Max. traverse speed 20 m/s 20 m/s
Accessories
Operating temperature –20...+80 °C –20...+80 °C
Housing material PBT PBT Basic
Degree of protection IP 67 IP 67 Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 37
S2B/S2E Series
Magnetic tape
S2B/S2E
02 1.55 mm thick, 4 18 μm, overall 3 With cover strip Order length, max. R0000 None or pole-periodic
with adhesive strip accuracy ±50 μm 0 Without 4800 = 48 m
03 1.35 mm thick, 5 50 μm, overall cover strip Rxxxx/ Position of
without adhesive strip accuracy ±100 μm 0000 1 reference point in cm
(S2E... and S1C... only)
Rxxxx/ Position of no more than
yyyy 2 reference points in cm
* Fixed-periodic reference point only for type BML-M02-I45-...
C0006/ Fixed-periodic all yyyy cm,
yyyy 0005, 0010
Ordering example: Magnetic tape by the roll, pole width 5 mm
BML-M02-I4_-A0-T_ _ _ _-R0000
Flush
Magnetic tape
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
S1F series
S2B/S2E series
General data
Magnetic tape
Series Sensor range B/C/E Sensor range B/C/E Sensor range B/C/E
Magnet Rings
Ordering code BML002T BML002R BML002P
Technical
Part number BML-M22-I40-A0-M031/016-R0 BML-M21-I40-A0-M048/006-R0 BML-M20-I40-A0-M072/054-R1 selection guide
Number of poles 20 32 46
Pole width 5 mm 5 mm 5 mm S1C series
With reference mark no no yes General data
Material Hard ferrite/aluminum Hard ferrite/aluminum Hard ferrite Magnetic tape
Magnet Rings
Technical
20 16 selection guide
15 11
10 9 Accessories
2 5
Basic
2 Information and
Definitions
M4
Ø16 H7
Ø30.9
M3
Ø22
Ø29
Ø24
Ø6 H7
Ø48.7
72
54
Ø21.3
Ø45
Ø30
2.5
www.balluff.com 39
S2B/S2E Series
Magnet rings
Series Sensor range B/C/E Sensor range B/C/E Sensor range B/C/E
Ordering code BML002L BML002M BML002N
Part number BML-M20-I40-A0-M031/021-R0 BML-M20-I40-A0- M048/037-R0 BML-M20-I40-A0-M072/054-R0
Number of poles 20 32 46
Pole width 5 mm 5 mm 5 mm
With reference mark no no no
Material Hard ferrite Hard ferrite Hard ferrite
30.9
21.3
37.2
48.7
72
54
The BML system allows precision adaptation to the relevant Please use the following formula to select a suitable controller:
application. Balluff offers a technical selection guide that provides 1
Counting frequency of the controller ≥
valuable assistance. For additional examples, see Basic Information Min. edge separation
and Definitions on page 54.
Example: If the sensor has a minimum edge separation of 1 μs, then
Selecting a suitable controller a controller capable of detecting at least 1 MHz must be selected Magnetically
Each sensor with a digital output signal has a characteristic mini- based on the above formula. coded posi-
tion and angle
mum edge separation gap that the higher-level controller must measurement
reliably detect. We therefore recommend selecting a controller with system
a counting frequency that is higher than the theoretically calculated
S1H series
counting frequency.
S1F series
Maximum speed Refer to Table 1 for the maximum travel speed. When selecting a
The BML system enables the detection of rotary movements. The maximum speed for the application, we recommend using a value
speed and the diameter of the magnetic ring determine the speed of 10% lower than this value.
the ring on the sensor head. Example:
The maximum travel speed that the sensor can still identify depends You are using a BML-S2B sensor with a resolution of 5 μm (F)
on the resolution and the edge separation of the sensor head. Reso- and a minimum edge separation of 1μs (G). For this sensor, Table 1
lution and edge separation can be selected. A maximum speed is gives a maximum travel speed of 3.25 m/s.
then calculated using the following formula: If the magnetic ring diameter is 48 mm = 0.048 m, a speed of
60 × max. travel speed (m/s) 1293 rpm can be achieved using the formula. With consideration for
Max. speed (rpm) =
π × magnet ring diameter (m) the reduced value, the speed should not exceed 1164 rpm.
www.balluff.com 41
S1C Series cost-effective
General data
Counter-Displays
C t Di l
Page 50
Tape
Page 44
Magnet Rings
Page 45
BML-S1C0-Q53_-M400-_0-KA_ _
Preferred type
■ BML S1C0-Q53L-M400-M0-KA05 (BML0034)
Digital signal, 10 to 30 V, 5 m cable, resolution 0.1 mm, edge separation 10 μs, max. travel speed up to 8 m/s
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
www.balluff.com 43
S1C Series
Magnetic tape
Ordering example:
Fabricated magnetic tape, pole width 5 mm Magnetic tape
Ordering example:
Magnetic tape by the roll, pole width 5 mm Magnetic tape mounting options
(also in magnetizable material)
BML-M02-I46-A0-T_ _ _ _-R0000
"Top"-Installation
Length
Flush
0500 5m
1000 10 m
2400 24 m
4800 48 m Flush with casting
BMF 12M-PS-D-2-S4
Speed monitoring in rotary applications:
Simply more cost-effective.
Designed for the B/C/E sensor family, the magnet rings and mag-
netic tapes shown here allow you to measure speed by means of
switching magnetic field sensors from the BMF series. With its stan-
dard M12 thread, the BMF 12M-PS-D-2-S4 sensor can be installed
in a wide range of applications. and can be installed as close as
2 mm from the magnet. A pulse signal that reflects the rotary speed
is present at the switching output. The sensor can detect frequen-
cies up to 7 kHz, therefore speeds of up to about 20,000 rpm are
possible, depending on the selected tape.
Magnetically
coded posi-
tion and angle
measurement
system
S1H series
Series Sensor range B/C/E Sensor range B/C/E
Ordering code BML002T BML002R S1F series
Part number BML-M22-I40-A0-M031/016-R0 BML-M21-I40-A0-M048/006-R0
Number of poles 20 32 S2B/S2E series
General data
Pole width 5 mm 5 mm
Magnetic tape
With reference mark no no
Magnet Rings
Material Hard ferrite/aluminum Hard ferrite/aluminum
Technical
selection guide
20 16
S1C series
15 11
General data
10 9
Magnetic tape
2 5
Magnet Rings
2 Technical
selection guide
M4
Accessories
Ø16 H7
Ø30.9
M3
Ø22
Ø29
Ø24
Basic
Information and
Ø6 H7
Ø48.7
Ø21.3
Ø45
Ø30
Definitions
2.5
www.balluff.com 45
S1C Series
Magnet rings
Series Sensor range B/C/E Sensor range B/C/E Sensor range B/C/E
Ordering code BML002L BML002M BML002N
Part number BML-M20-I40-A0-M031/021-R0 BML-M20-I40-A0-M048/037-R0 BML-M20-I40-A0-M072/054-R0
Number of poles 20 32 46
Pole width 5 mm 5 mm 5 mm
With reference mark no no no
Material Hard ferrite Hard ferrite Hard ferrite
30.9
21.3
37.2
48.7
72
54
The BML system allows precision adaptation to the relevant Please use the following formula to select a suitable controller:
application. Balluff offers a technical selection guide that provides 1
Counting frequency of the controller ≥
valuable assistance. For additional examples, see Basic Information Min. edge separation
and Definitions on page 54.
Example: The sensor has a minimum edge separation of 1μs. Then
Selecting a suitable controller the outcome, according to the formula above, is a controller that can Magnetically
Each sensor with a digital output signal has a characteristic minimum detect at least 1 MHz. coded posi-
tion and angle
edge separation gap that the higher-level controller must reliably measurement
detect. We therefore recommend selecting a controller with a count- system
ing frequency that is higher than the theoretically calculated counting
S1H series
frequency.
S1F series
Accessories
Rotary applications Determining the pulses per rotation
The BML system allows precision adaptation of rotary tapes to the The number of required pulses per rotation varies depending on the Basic
relevant application. application. It determines the resolution of the sensor head and the Information and
Definitions
Balluff offers a technical selection guide for rotary systems that pro- diameter of the magnet ring.
vides valuable assistance.
Maximum speed
The BML system enables the detection of rotary movements. The Example:
speed and the diameter of the magnetic ring determine the speed of You are using a BML-S1C sensor with a resolution of 100 μm (L)
the ring on the sensor head. and a minimum edge separation of 10 μs (M). For this sensor, Table
The maximum travel speed that the sensor can still identify depends 1 gives a maximum travel speed of 8 m/s.
on the resolution and the edge separation of the sensor head. Reso- If the magnet ring diameter is 48 mm = 0.048 m, a speed of
lution and edge separation can be selected. A maximum speed is 3183 rpm can be achieved according to the formula.
then calculated using the following formula: With consideration for the reduced value, the speed should not
exceed 2865 rpm.
60 × max. travel speed (m/s)
Max. speed (rpm) =
π × magnet ring diameter (m)
www.balluff.com 47
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
Accessories
Counters and displays are available for all series to integrate the
sensor systems perfectly into your application.
The range of sensor guides enables you to integrate robust, high-
precision measurement systems even where there is no optimum
guide.
48
Accessories
Contents
Accessories
Counter-Displays 50
Sensor guide 52
www.balluff.com 49
Accessories
Counter-Displays
Series
Interface
Ordering code
Part number
Ordering code
Part number
Ordering code
Part number
Functions
Features
Use
Magnetically
coded posi-
tion and angle
measurement
system
BDD 610 BDD 611/BDD 622/BDD 63 6
632
32
Single-axis counter Single- or multi-axis counter 1, 2, 3 S1H series
for BML-S1B..., BML-S1C... for all BML-Sxx...
S1F series
and BML-S1E...
BAE004J BAE004K
S2B/S2E/S1C
BDD 610-R3Q3-0-53-N-00 (2 dig. inputs) BDD 611-R3Q4-0-52-N-00 (1 axis) series
BAE004H BAE004M
BDD 610-R3Q3-0-51-N-00 (2 dig. outputs) BDD 622-R3Q4-0-52-N-00 (2 axes) Accessories
BAE004P Counter-
Displays
BDD 632-R3Q4-0-52-N-00 (3 axes)
Sensor guide
■ Set value ■ Set value
■ Actual value memory ■ Actual value memory Basic
Information and
■ Factor calculation ■ Factor calculation Definitions
■ Count direction reversal ■ Edge evaluation
■ Up to 3 decimal places ■ Count direction reversal
■ Assignable key functions ■ Up to 3 decimal places
■ Reset and set logic ■ Assignable key functions
■ Logic for inputs and outputs ■ Reset and set logic
■ Security code ■ Absolute and incremental measurement
■ Offset logic
■ Sawtooth correction
■ Logic for inputs and outputs
■ Security code
■ Reference pulse
for BML-S1B0..., BML-S1E0... For BML with supply voltage 5 V/10 to 30 V, output voltage RS422/HTL,
and BML-S1C0-..., min. edge separation Code E, F, G, H, K, L, M, N, P, R
min. edge separation Code M, N, P, R
F E
96
72
www.balluff.com 51
Accessories Gives guidance
Sensor guide
Features
■ Customized lengths
■ Easily attached by directly screwing on or using mounting
elements
■ Rails can be mounted side by side and elements disassembled Sensor guide
■ Connection of drag chains possible
■ Flat design, minimal space requirements Ordering code
■ Low costs Part number
■ Runners need no lubrication, thus no maintenance costs Features
■ Minimum stock-keeping, since the universal concept works for
various sensor heads
■ Mounting aid for easy installation of the magnetic tape
You may cover the magnetic tape with a stainless steel cover strip to
protect it from damage caused by chips or chemicals.
Note that the permissible air gap between the sensor head and
tape is reduced by the thickness of the cover strip with adhesive film
(0.15 mm).
Nominal stroke
Adjustment range
–5 mm
Magnetically
coded posi-
tion and angle
measurement
system
Guide rail Sliding carriage Sliding carriage
S1H series
for sliding carriage BML-C01, BML-C02 for sensors BML-S2B, BML-S2E, BML-S1C for sensors BML-S1F
e.g. BAM04N4 (3 m) BAM01MF BAM01MH
S1F series
BML-R01-M_ _ _ BML-C01 BML-C02
■ Anodized aluminum ■ Aluminum ■ Aluminum S2B/S2E/S1C
■ Mounting holes ■ Fully mounted with runners ■ Fully mounted with runners series
■ Lateral groove for alternate mounting ■ Connection for joint rod ■ Connection for joint rod
using brackets ■ Connection for drag chains ■ Connection for drag chains Accessories
Counter-Displays
■ Mountable side by side ■ Maintenance-free dry operation ■ Maintenance-free dry operation
Sensor guide
■ Maintenance-free dry operation ■ Lubricant-free ■ Lubricant-free
■ Lubricant-free Basic
■ Suitable for all linear tapes Information and
Definitions
3
M
27.4
½
½
18
-
5 8
M
6
10.5
23.9
-
22
M
3
M
3
M
5
25
124.7
R8
16
Adhesive strip
18.65
1.25
www.balluff.com 53
Magnetically
Coded Posi-
tion and An-
gle Measure-
ment System
54
Basic Information and Definitions
Contents
www.balluff.com 55
Basic Information and Definitions
Definitions
System accuracy The accuracy of the sensor head depends largely on mechanical Accuracy of the tape
manufacturing tolerances and component tolerances; the accuracy BML-M02-I34
of the tape is determined by the material quality and the magnetiza-
tion grade.
+
Accuracy of the
4x evaluation With 4-fold evaluation, the controller counts every 4 edge changes sensor head
within a signal period. A signal period = 4x selected resolution. BML-S1F...
Example:
Sensor head 1 μm resolution, magnet ring with 384 poles (1 mm).
PER
± 10 μm
2. 4.
1.
3.
EDG
Electric angle
Edge separation With 4-fold evaluation, the following applies (each edge is counted):
Important! S2B/S2E/S1C
The controller/display must be able to count the minimum time- series
based edge separations shown in the tables (note the counting
frequency of your controller). Accessories
The minimum edge separation may occur even when the system is
Basic
at rest due to the internal interpolation procedure. Information and
Always select the next higher travel speed or the next faster Definitions
minimum edge separation; otherwise, during the evaluation by the Definitions
Examples and
controller, errors can arise in the position determination. help for
selecting the
system
Repeat accuracy Repeat accuracy is the value resulting when moving to the same po-
sition from the same direction under unchanging ambient conditions.
Incremental After the system is switched on, the measured value currently avail-
able is not defined. A reference run to a defined point, a reference
point, is necessary in order to obtain a position value. The position
value is calculated by adding or subtracting single identical incre-
ments from the reference point.
Absolute The measured value for the current position is available immediately
after the system is switched on. Each position, e.g. a measurement
section, is assigned an absolute, coded digital signal or an analog
value. A reference run is not required.
Temperature coefficient The temperature coefficient indicates the relative change in length as
temperature changes. This means that temperature factors change
the measured value by the indicated amount.
Sampling rate The measurement rate is the frequency at which the output posi-
tion information is updated. It can be the same as the number of
measurements per second. A high sampling rate for rapidly changing
positions is important when the process is time-critical.
www.balluff.com 57
Basic Information and Definitions
Examples and help for selecting the system
Tape, pole width On the magnetic tape, there is a track with alternating magnetic
north and south poles. In some variants, a second track with
reference points is available.
1 mm
5 mm
1 mm
5 mm
n
lutio
The magnetic tape exists in various versions. You therefore have to reso
5 μm hea
d
sor
take care that the magnetic tape and sensor head fit together. Sen
B
A
Interpolation The magnetic period of the tape is interpolated by the sensor head
mm
with integrated interpolator with up to 10-bit (factor 1000). th 5
wid
e pole +
tap el
rav
gnetic n of t
Ma ctio
– Dire
Carrier material
Magnetizable material
Carrier material
Reference point function For each incremental encoder system, the reference position is es-
sential as a starting point for the counting.
How the reference point is determined depends on the sensor head,
the magnetic tape and the controller itself.
Advantages of the pole-periodic and fixed-periodic tapes: The tape
can be bought in great lengths and cut to size by the customer. Magnetically
The reference point functions are possible with linear and with round coded posi-
tion and angle
tapes (rings, only with sensor head BML-S2B/E, BML-S1F...). measurement
system
S1H series
Relationship between Sensor head design for controller with 4-fold evaluation:
resolution, speed and edge
S1F series
separation (examples) Example 1: Resolution needed: F = 5 μm
■ In table 1 on page 41 Select column 1. S2B/S2E/S1C
Max. travel speed = 7 m/s series
■ Select line 2 = 10 m/s.
➔ Edge separation E = 0.29 μs Accessories
Basic
Example 2: Resolution needed: G = 10 μm Information and
■ In table 1 on page 41 Select column 2. Definitions
Max. counting frequency of the controller = 0.5 m/s Definitions
Examples and
edge separation H = 2 μs help for
■ Select line 5. selecting the
system
➔ Maximum possible travel speed: 3 m/s
www.balluff.com 59
Basic Information and Definitions
Examples and help for selecting the system
Single reference point For the magnetic tape with single reference point, the reference point
magnetic tape may be integrated as desired at any location. To determine the exact
type BML-M...-R_ _ _ _ /0000 absolute position, the reference run must cover the entire length of
the tape up to the reference point.
100 cm
Total length
Magnetic tape with two For the magnetic tape with two reference points, the reference point
reference points, may be integrated as desired at any location. To determine the exact
type BML-M...-R_ _ _ _ /_ _ _ _ position, the reference run must cover the entire length of the tape
up to the external selection switch. The external selection switch
decides on the use of Z signals.
120 cm
200 cm
Total length
Magnetically
coded posi-
tion and angle
measurement
system
The sensor head with an additional reference point sensor can also
S1H series
be combined with a magnetic tape with fixed-periodic reference
points. Here the reference points are integrated across the entire
S1F series
length of the tape at certain constant intervals, such as every 10 cm.
To determine the exact position, the reference run must go to the S2B/S2E/S1C
external selection switch. series
Accessories
Basic
Magnetic tape with For magnetic tapes with fixed-periodic reference points, the refer- Information and
fixed-periodic ence points are integrated across the entire length of the tape at Definitions
reference points, certain constant intervals, such as every 20 cm. To determine the Definitions
Examples and
type BML-M...-C0006/_ _ _ _ exact position, the reference run must extend to the external selec- help for
tion switch, which decides on the use of the Z signals. selecting the
system
6 cm 20 cm 20 cm 20 cm 20 cm
www.balluff.com 61
Basic Information and Definitions
Examples and help for selecting the system
Pole-periodic magnetic tape, The pole-periodic magnetic tape has alternating magnetic north and
type BML-M...-R0000 south poles, but no integrated reference point.
3500 cm
Total length
Maximum speed The BML system enables the detection of rotary movements. The
speed and the diameter of the magnetic ring determine the speed
of the ring on the sensor head. The maximum travel speed that the
sensor can still identify depends on the resolution and the edge
separation of the sensor head. Resolution and edge separation can
be selected. A maximum speed is then calculated using the follow- Magnetically
ing formula: coded posi-
tion and angle
measurement
system
Max. speed [rpm] = 60 × max. travel speed [m/s]
π × Magnetic ring diameter [m]
S1H series
For the maximum travel speed and minimum edge separation, see
S1F series
table 1 on page 41 Recommendation: max. speed 10 % less than
determined speed value. S2B/S2E/S1C
series
Accessories
Max. RPM
travel Outer diameter
Basic
speed Information and
31 mm 49 mm 72 mm 75.4 mm 122 mm Definitions
Definitions
20 m/s 12,322 7795 5,305 5,066 3,131
Examples and
14.75 m/s 9,087 5,749 3,913 3,736 2,309 help for
10 m/s 6,161 3,898 2,653 2,533 1,565 selecting the
system
8.8 m/s 5,422 3,430 2,334 2,229 1,378
8 m/s 4,929 3,118 2,122 2026 1,252
7.7 m/s 4,744 3,001 2042 1,950 1,205
6.5 m/s 4,005 2,533 1,724 1,646 1018
5 m/s 3,080 1949 1,326 1,266 783
4.2 m/s 2,588 1,637 1,114 1,064 657
3.95 m/s 2,434 1,540 1,048 1,001 618
3.25 m/s 2,002 12671) 862 823 509
3 m/s 1,848 1169 796 760 470
1.8 m/s 1,109 702 477 456 282
1.7 m/s 1,047 663 451 431 266
1.5 m/s 924 585 398 380 235
0.95 m/s 585 370 252 241 149
0.9 m/s 554 351 239 228 141
0.75 m/s 462 292 199 190 117
0.65 m/s 400 253 172 165 102
0.395 m/s 243 154 105 100 62
0.375 m/s 231 146 99 95 59
0.26 m/s 160 101 69 66 41
0.195 m/s 120 76 52 49 31
0.13 m/s 80 51 34 33 20
1)
see example below
Table 2: Maximum speed of rotary tape (magnetic ring)
Example Sensor head BML-S2B… with a resolution of 5 μm (F) and a min.
edge separation of 1 μs (G). From table 1 on page 41 for this sensor
head, there is a max. travel speed of 3.25 m/s.
With a magnetic ring diameter of 49 mm = 0.049 m, according to
the formula, a speed of 1,267 rpm can be reached (the value can
also be read out in table 2 (column 49 mm/line 3.25 m/s)). Under
consideration of the recommendation to stay 10 % below this, a
speed of 1,140 rpm is not to be exceeded.
www.balluff.com 63
Micropulse
Transducers
64
Micropulse Transducers
Contents
Accessories
can be found on
page 230
Basics
and definitions
can be found on
page 250
www.balluff.com 65
Micropulse Transducers
Applications
Areas of use in which high reliability and precision are in demand are Areas of application
typical application areas for Micropulse Transducers. ■ Pitch adjustment on wind generators
As integrated or compact versions with measuring lengths of 25 to ■ Positioning reflection channels on thermosolar power plants
7,500 mm, Micropulse position measuring systems are able to be ■ Large, hydraulically powered valves
used universally. ■ Casting and rolling mills
The non-contact working principle of the systems guarantees com- ■ Lift controls
plete freedom from wear and a virtually endless service life. The high- ■ Flight simulators
precision output signal serves as an absolute signal for the controller ■ Foundries
in a wide range of different interfaces. ■ Logging machines
■ Automation engineering
As a position measuring system for actual value recording, integrated ■ Hydroelectric power stations
in the pressure area of hydraulic cylinders, Micropulse Transducers ■ Locks and floodgates
are used in the most varied areas. ■ Construction machinery
■ Combine harvesters
Industrial applications
■ Pumps and compressors
■ Elevator and lifting technology
■ Forging presses
■ High-pressure hydraulics
Heavy-duty cylinders raise the bridge to the planned road level after they are
"floated" into position.
Micropulse
Transducers
Sawmill machinery
Applications
Function principle
Design
Product overview
Profile P
Profile PF
Profile AT
Profile BIW
Rod
Hydraulic riveting system
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Wind power plant Definitions
www.balluff.com 67
Micropulse Transducers
Applications
Areas of application
■ Injection molding
■ Pressing
■ Handling systems
■ Portal robots
■ Woodworking machinery
■ Packaging machinery
■ Conveying
■ Straightening machinery
■ Surgical tables
■ Concrete block making machinery
Micropulse
Transducers
Applications
Function principle
Design
Product overview
Multiple-stage press
Profile P
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Accessories
Areas of application
■ Process technology
■ Filling of foodstuffs
■ Level monitoring in milk tanks
■ Filling units
■ Perfume manufacturing
■ Pharmaceuticals
■ Producing alcohol
Level monitoring
www.balluff.com 69
Micropulse Transducers
Function principle
Rod housings Rod housings are mainly used in hydraulic drive applications.
When installed in the pressure section of the hydraulic cylinder, the
displacement sensor requires the same pressure rating as the actual
hydraulic cylinder. In practice, the sensor must be able to withstand
pressures up to 1,000 bar. The electronics are integrated in an alu-
minum or stainless steel housing and the waveguide in a pressure-
resistant tube made from nonmagnetic stainless steel that is sealed
off at the front end with a welded plug. An O-ring seal in the flange at
the opposite end seals off the high-pressure section. An magnet ring
with magnets slides over the tube or rod with internal waveguide to
mark the position prior to detection. Micropulse
Transducers
Applications
Function
principle
Design
Product overview
Profile P
Profile PF
Profile AT
Rod system components A position measuring system consists of the actual transducer, the
Profile BIW
magnet and a wiring for the electronic evaluation unit.
Rod
Filling Level
Sensor SF
+ Accessories
Basic
Information and
Definitions
www.balluff.com 71
Micropulse Transducers
Designs
Profile housings The electronics and the waveguide are stored in an aluminum pro-
filed housing. The aluminum housing is hermetically sealed according
to degree of protection IP 67. The magnets on the magnet act on
the waveguide through the wall of the aluminum profile.
There are two different versions of magnet, namely captive and float-
ing magnets. Floating magnets are secured directly on the moving
machine part and move with the part above and along the profile at
a certain distance. The advantage is that guide precision is not an
issue with this type of sensor. The sensors tolerate an offset to the
side and at the height of up to a few millimeters. If these generous
tolerances are exceeded, you can always revert to using captive
magnets. With captive magnets, the profile housing of the displace-
ment sensor acts as a sliding rail along which the magnet travels. In
this case, a control arm with spherical heads compensates for even
highly unparallel movements.
Profile system components A position measuring system consists of the actual transducer, the
magnet and wiring for the electronic evaluation unit.
+ = Maximum dist
distance
15 mm between
ta
ance of
een the posi-
tion measuring system and
the floating Magnet
Safety through redundancy Magnetostrictive displacement sensors are ideal for applications
requiring a high degree of safety or availability. The sensors often
have a 2-times or even 3-times redundant design in order to ensure
mutual monitoring or provide a reserve channel when required. A Micropulse
displacement sensor with a 3-times redundant design incorporates Transducers
3 adjacent waveguides offset by 120°C and housed in a collective Applications
Function principle
protective tube along which a magnet moves, in much the same
Design
way as on standard housings. The magnets on the magnet act on
Product overview
all three measurement sections simultaneously. The evaluation of the
3 positions is done by 3 independent and completely disconnected Profile P
electronics, which, however, may be stored in the same housing.
Application examples include ship propulsion drives, power stations Profile PF
and train inclination technology.
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 73
Micropulse Transducers extremely rugged
Product overview
and reliable
Rod
Series Profile style Profile style Profile AT Profile BIW Rod
Compact
Design P PF A1 P1 B, A, Z, Y H, K, W
Installation version
■ ■
e.g. in hydraulic cylinders
External fitting version
■ ■ ■ ■
e.g. on machine frames
Filling level sensor
e.g. device filling systems
Special approvals
Multi-Magnet ■ ■ ■
Interfaces
Analog voltage
■ ■ ■ ■ ■ ■
0...10 V, 10...0 V, –10 V...10 V
Analog current
■ ■ ■ ■ ■
4...20 mA, 0...20 mA
SSI ■ ■ ■
SSI-SYNC ■ ■ ■
CANopen ■ ■ ■
DeviceNet ■
Profibus DP ■ ■
VARAN ■
EtherCAT ■
IO-Link ■
Filling Level
■ ■ ■ ■ ■ ■ ■ Sensor SF
Accessories
■ ■ ■ ■ ■ ■ ■
Basic
■ ■ ■ Information and
Definitions
■ ■
■ ■
■ ■ ■ ■ ■ ■ ■
www.balluff.com 75
Micropulse
Transducers
Profile P
■ The universal standard series
■ Stroke lengths up to 7,620 mm
■ Multiple paths – one system, which measures position in many
paths
■ Programmable output signals – measuring range, inverting,
configuring, documenting
■ Floating and captive magnets
■ Up to 15 mm distance between magnet and system – truly con-
tactless
■ Measures position and speed
■ Differential and synchronized measurement
■ Available with analog signals, digital interfaces and fieldbuses
76
Profile P
Contents
P BTL7
General data 78
Analog interface 80
Programming 82
P BTL5
General data 84
Analog interface 86
Digital pulse interface 88
SSI interface 90
CANopen interface 92
DeviceNet interface 94
Profibus DP interface 96
Floating magnets 98
Captive magnets, control arm 100
www.balluff.com 77
Profile P BTL7 Micropulse+ one system
General data
two paths
12 72 Nominal stroke 73
36.8
41
15 34.8 Micropulse
Installation length 50 Transducers
68
Profile P BTL7
General data
Analog interface
Programming
Profile P BTL5
General data
Analog interface
Transducer with floating magnet and S115 connection Digital pulse
interface
SSI interface
13.8 72 Nominal stroke 73
CANopen
interface
DeviceNet
interface
Profibus DP
interface
36.8
41
Floating Magnet
Captive Magnet
15 34.8 Profile PF
Installation length 50
68
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Transducer with captive magnet and KA cable outlet
Rod EX,
T Redundant
^ Nominal stroke and CD
¢ª
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
Installation length
www.balluff.com 79
Profile P BTL7 Micropulse+ "Length"
Analog interface
up to 7,620 mm
Temperature coefficient
Supply voltage
Polarity reversal protected
Overvoltage protected
Dielectric strength
Operating temperature
Velocity output
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Please enter code for output signal, nominal stroke and connection Rod Compact
in the Part number. and Rod AR
Rod EX,
Ordering example: T Redundant
and CD
BTL7-_501-M_ _ _ _-P-_ _ _ _
Filling Level
Sensor SF
Standard Accessories
Output signal Nominal stroke [mm] Connection
Basic
Information and
A 0...10 V and 10...0 V 0050...7620 mm in 5 mm increments S32 Connectors Definitions
E 4...20 mA and 20...4 mA S115 Connectors
KA02 PUR cable 2 m
KA05 PUR cable 5 m
KA10 PUR cable 10 m
KA15 PUR cable 15 m
www.balluff.com 81
Profile P BTL7 Micropulse+ USB Configurable
Programming
USB configuration
System requirements
■ Standard PC
■ Operating system: Windows 2000/XP/Vista/7
■ Screen resolution at least 1024 × 768 pixels
■ 10 MB available hard disk space
■ Install Java Runtime Environment (JRE) Version 1.4.2 or higher
http://java.com/getjava
■ USB port
BTL7-A-CB01-USB-S115,
for BTL7-A/E501... with Connector S115
BTL7-A-CB01-USB-KA,
for BTL7-A/E501... with cable connection
Scope of delivery
■ USB communication box
■ Cable set Communication box connected via cable in the
■ Quick start instructions control cabinet
Caution!
Please read the instructions in the user's guide before design-
ing, installing, and commissioning! www.balluff.de
Profile P BTL5
General data
Analog interface
Digital pulse
interface
SSI interface
CANopen
interface
DeviceNet
interface
Profibus DP
interface
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 83
Profile P BTL5 go beyond the limit
General data
The structural design, high degree of protection and simple instal- ■ Non-contact detection of the measurement position
lation of Balluff Micropulse Transducers in a profiled housing makes ■ IP 67, insensitive to contamination
them an excellent alternative to linear transducers, e.g. potentiome- ■ Wear-free
ters, glass rulers and LVDTs. The linear sensing element is protected ■ Insensitive to shock and vibration
inside an extruded aluminum profile. ■ Absolute output signal
A passive magnet with no power supply marks the measuring point ■ Max. resolution of 0.001 mm (depending on the electronic
on the measuring path without making contact. Measuring ranges evaluation unit)
between 50 and 5,000 mm are possible. ■ Direct signal evaluation or in conjunction with evaluation units
for all control and regulating systems
Nominal stroke
Micropulse
Transducers
Installation length
Profile P BTL7
General data
Transducers with captive magnets and cable outlet for transducers with analog interface, digital pulse interface
Analog interface
and SSI interface, from page 232
Programming
Nominal stroke
Profile P BTL5
General data
Analog interface
Digital pulse
interface
SSI interface
CANopen
interface
DeviceNet
interface
Profibus DP
Installation length interface
Floating Magnet
CANopen connection S 94 with connectors BKS-S 94-00 and BKS-S 92-00 for transducers Captive Magnet
with CANopen interface, page 234
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
CANopen connection S 92 with connector BKS-S 92-00 for transducers
Rod EX,
with CANopen interface, page 234 T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
DeviceNet connection S 93 with connectors BKS-S 92-00, BKS-S 93-00 and BKS-S -48-15-CP-_ _, page 234
Profibus DP connection S103 with plug connector BCC0715 and BCC0714, page 237 and BKS-S-48-15-CP-_ _ page 234
www.balluff.com 85
Profile P BTL5
Analog interface
The analog outputs of the profile series are potential-free with Series
respect to the input voltage. The isolation is galvanic using DC/DC Output signal
converters. Transducer interface
BTL transducers with analog outputs are available in the variants Customer device interface
0...0 V, 4...20 mA, 0...20 mA and –10...10 V, with rising and falling Part number
characteristics. Output
Output voltage
Output current
Load current
Max. residual ripple
Load resistance
System resolution
Hysteresis
Repeat accuracy
Sampling rate
Max. linearity deviation
Scope of delivery
■ Transducer
■ Mounting clamps with insulating sleeves and screws
■ Quick start instructions
≤ 4 μm ≤ 4 μm ≤ 4 μm ≤ 4 μm
Profile P BTL7
System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm
General data
fSTANDARD = 1 kHz fSTANDARD = 1 kHz fSTANDARD = 1 kHz fSTANDARD = 1 kHz Analog interface
±100 μm up to 500 mm nominal stroke ±100 μm up to 500 mm nominal stroke ±100 μm up to 500 mm nominal stroke ±100 μm up to 500 mm nominal stroke Programming
±0.02% 500 to max. nominal stroke ±0.02% 500 to max. nominal stroke ±0.02% 500 to max. nominal stroke ±0.02% 500 to max. nominal stroke
[150 μV/°C + (5 ppm/°C × P × U/L)] × ΔT [150 μV/°C + (5 ppm/°C × P × U/L)] × ΔT Profile P BTL5
[0.6 μA/°C + (10 ppm/°C × P × I/L)] × ΔT [0.6 μA/°C + (10 ppm/°C × P × I/L)] × ΔT General data
20...28 V DC 20...28 V DC 20...28 V DC 20...28 V DC Analog interface
≤ 150 mA ≤ 150 mA ≤ 150 mA ≤ 150 mA Digital pulse
interface
yes yes yes yes
SSI interface
TransZorb protection diodes TransZorb protection diodes TransZorb protection diodes TransZorb protection diodes CANopen
500 V DC (ground to housing) 500 V DC (ground to housing) 500 V DC (ground to housing) 500 V DC (ground to housing) interface
–40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C DeviceNet
interface
-40...+100 °C -40...+100 °C -40...+100 °C -40...+100 °C
Profibus DP
interface
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
Ordering example: and CD
Accessories
Basic
Standard Information and
Definitions
Output signal Nominal stroke [mm] Connection
www.balluff.com 87
Profile P BTL5 cost-effective +
Digital pulse interface
synchronous
P Interface
The P-interface fits Balluff BTA/BTM evaluation units and controllers
and modules of various manufacturers, e.g. Siemens, B & R, Phoenix
Contact, Mitsubishi, Sigmatek, Esitron, and WAGO, among others.
Secure signal transfer even with cable lengths of 500 m between the
BTA evaluation unit and the BTL transducer guarantee the particularly
interference-free RS485 differential driver and receiver. Noise signals
are effectively suppressed.
M interface
The I and M interfaces are control-specific interface variations.
Benefits
■ Position resolution 1 μm!
■ The 1 μm resolution of the Micropulse position measuring system
is achieved by the high resolution of the digitizing chip (133 pS)
(clock frequency 2 or 20 MHz).
■ Position data from 4 magnets can be processed simultaneously
■ 4/8-bit processor interface
5V Osc.
4/8 INIT
bit bus
CPU
controller
P pulse signal
Controller or
electronic evaluation unit
ASIC INFO:
+49 7158 173-370
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Please enter the code for Ordering example:
the nominal stroke in the part number. Filling Level
Sensor SF
BTL5-P1-M_ _ _ _-P-_ _ _ _
Scope of delivery Accessories
■ Transducer
■ Mounting clamps with insulating sleeves Basic
and screws Information and
Standard Definitions
■ Quick start instructions Nominal stroke [mm] Connection
www.balluff.com 89
Profile P BTL5 super linear
SSI interface
and synchronous
The clock frequency depends on the cable length. Cable length Clock frequency
< 25 m < 1000 kHz
< 50 m < 500 kHz
< 100 m < 400 kHz
< 200 m < 200 kHz
< 400 m < 100 kHz
Clock sequence
Profile P BTL5
General data
Analog interface
Digital pulse
interface
SSI interface
CANopen
Please enter code for coding, system resolution and Scope of delivery interface
nominal stroke in the part number. ■ Transducer DeviceNet
interface
■ Mounting clamps with insulating sleeves and screws
Profibus DP
■ Quick start instructions interface
Profile AT
Ordering example:
Profile BIW
BTL5-S1_ _-M_ _ _ _-P-_ _ _ _ for asynchronous operation
BTL5-S1_ _-B-M_ _ _ _-P-_ _ _ _ for synchronous operation Rod
Rod Compact
and Rod AR
Rod EX,
System Standard T Redundant
Coding resolution nominal stroke [mm] Connection and CD
www.balluff.com 91
Profile P BTL5
®
Position + Velocity
CANopen interface
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
Please enter code for software Ordering example: and Rod AR
configuration, baud rate and
Rod EX,
nominal stroke in the part number. BTL5-H1_ _-M_ _ _ _-P-S92 T Redundant
BTL5-H1_ _-M_ _ _ _-P-S94 and CD
Scope of delivery
■ Transducer Filling Level
Sensor SF
■ Mounting clamps
with insulating sleeves and screws Software Standard Accessories
■ Quick start instructions configuration Baud rate nominal stroke [mm]
Basic
Please order separately: Information and
1 1× Position and 0 1 Mbaud 0050...4000 Definitions
Magnets, on page 98 1× speed 1 800 kbaud in 5 mm increments
Plug connectors, page 232 2 2× Position and 2 500 kbaud
2× speed 3 250 kbaud
4 125 kbaud
5 100 kbaud
6 50 kbaud
7 20 kbaud
8 10 kbaud
www.balluff.com 93
Profile P BTL5
DeviceNet interface
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
www.balluff.com 95
Profile P BTL5 Position + Velocity
Profibus DP interface
As the market leading standard for serial data transmission for pro- Process data
cess automation, Profibus DP is the ideal choice for implementing Under Profibus DP, by default, the process data is to be sent from
automation tasks with cycle times of > 5 ms. the master to slaves acyclically and for the slave data to then be
queried. To ensure synchronization of multiple devices, the master
Data transmission may use the SYNC and FREEZE services.
A Profibus telegram can contain up to 244 bytes of user data per
telegram and node. The BTL5-T uses max. 32 bytes (max. 4 position DP/V1 and DP/V2 isochronous mode
values and max. 4 velocity values) for process data transmission. Isochronous mode enables quick and deterministic data exchange
Up to 126 active stations (addresses 0...125) can be connected on by means of clock synchronicity on the bus system. A cyclical,
Profibus DP. User data cannot be sent with node address 126. This equidistant clock signal is sent by the master to all bus nodes. This
address is used as the default address for bus nodes that have to signal allows master and slaves to be synchronized irrespective of
be configured by a Class 2 master (for setting the device address if application – with an accuracy < 1 μs.
there are no mechanical switches available). Each Profibus station
has the same priority. Prioritizing of individual stations is not intend- FMM
ed, but can be done by the master since the bus transmission only The sensor can be operated as a 4-magnet type, whereby the sen-
makes up a fraction of the process cycle anyway. At a transfer rate sor itself recognizes how many magnets are currently active.
of 12 Mbaud, the transmission time for an average data telegram is So if only two magnets are positioned in the measuring range, a valid
in the 100 μs range. value is output for the first two positions and an error value is defined
in positions 3 and 4.
GSD (device master data)
The length of the data exchangeable with a slave is defined in the
Device Master Data file (GSD) and is checked by the slave with the
configuration telegram and confirmed for correctness.
In modular systems, various configurations are defined in the GSD
file. Depending on the desired functionality, one of these configura-
tions can be selected by the user when the system is configured.
The BTL5-T is a modular device with the possibility of selecting the
number of magnets (position values).
Floating Magnet
Captive Magnet
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
Please enter code for software configuration Ordering example: and CD
and nominal stroke in the Part number.
BTL5-T1_ 0-M_ _ _ _-P-S103 Filling Level
Sensor SF
Scope of delivery
■ Transducer Software Standard
Accessories
■ Mounting clamps configuration nominal stroke [mm]
with insulating sleeves and screws Basic
■ Quick start instructions 1 1× Magnet 0050...4000 in 5 mm increments Information and
Definitions
1× Position
Please order separately: 1× Speed
Magnets, on page 98 2 2× Position
Plug connector, on page 232 2× Speed
www.balluff.com 97
Profile P Non-contact!
Floating magnet
Distance up to 15 mm
Accessories
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Profibus DP
9
interface
50 +4
Floating Magnet
Captive Magnet
Profile PF
1
50
68
Profile AT
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 99
Profile P BTL Inclusive
Captive magnet
guidance system
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Profile P BTL7
General data
Analog interface
Programming
Adjustment range –5 mm
Profile P BTL5
General data
Analog interface
Digital pulse
interface
SSI interface
CANopen
Please enter the code for the interface
nominal stroke in the part number. DeviceNet
interface
Profibus DP
Ordering example: interface
Rod EX,
Swivel eye T Redundant
Material number 714619 and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
When using captured magnets with ball joint and control arm,
transverse forces do not impinge on the transducer system.
www.balluff.com 101
Micropulse
position
measuring
Micropulse
system
Transducers
Profile PF
■ Flat design, fits in every niche
■ Easy to install
■ Characteristic curve setting with LED support for quick
commissioning
■ High degree of protection, IP 67 standard
■ Up to 15 mm distance between magnet and
system – truly contactless
■ Floating and captive ball joint arm magnets
■ Available with the entire series of analog signals
102
Profile PF
Contents
PF
General data 104
Analog interface 106
IO-Link V1.1 108
Floating magnet 110
Captive magnet 112
www.ballu
www.balluff.com
balluffff.com
com 103
Profile PF becomes flat
General data
LED for
diagnostics and
Programming
programming
input La
assistance
Programming
input Lb
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Transducers with floating magnet and connection S115 with BKS-S115/BKS-S116 connector Profile AT
Profile BIW
Nominal stroke
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Installation length Sensor SF
Accessories
Basic
Information and
Definitions
Scope of delivery
■ Transducer (select your interface from page 106)
■ Quick start instructions
■ Mounting clamps with insulating sleeves and screws
www.balluff.com 105
Profile PF Adjustable
Analog interface
with diagnostics
Temperature coefficient
after Supply voltage
Current consumption
New zero point Operating temperature
Storage temperature
Calibration box
Calibration boxes with cable sets
Part number Cable set Read in new end point
BTL7-A-CB02 Cable connection
BTL7-A-CB02-S115 Connector S115
BTL7-A-CB02-S32 Connector S32
±200 μm up to 500 mm nominal stroke ±200 μm up to 500 mm nominal stroke ±200 μm up to 500 mm nominal stroke ±200 μm up to 500 mm nominal stroke
Profile P
±0.04% 500... max. nominal stroke ±0.04% 500... max. nominal stroke ±0.04% 500... max. nominal stroke ±0.04% 500... max. nominal stroke
30 ppm at 500 mm 30 ppm at 500 mm 30 ppm at 500 mm 30 ppm at 500 mm Profile PF
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC General data
≤ 150 mA ≤ 150 mA ≤ 150 mA ≤ 150 mA Analog interface
–25...+70 °C –25...+70 °C –25...+70 °C –25...+70 °C IO-Link V1.1
–40...+100 °C –40...+100 °C –40...+100 °C –40...+100 °C Floating Magnet
Captive Magnet
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Output signal can be inverted via programming inputs.
Filling Level
Sensor SF
Accessories
Basic
Information and
LED for Definitions
diagnostics and
Programming
programming
input La
assistance
Programming
input Lb
Please enter code for output signal and nominal stroke Ordering example:
in the part number.
BTL6-_500-M_ _ _ _-PF-S115
Scope of delivery
■ Transducer
■ Mounting clamps with insulating sleeves and screws Standard
■ Quick start instructions Output signal nominal stroke [mm]
www.balluff.com 107
Profile PF
IO-Link V 1.1
Industrial Ethernet
Profile AT
Tcyc
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Command Checksum
Accessories
Parameter / Diagnostics Process data Checksum
Basic
Information and
Definitions
Please enter the code for the nominal stroke in Ordering example:
the part number.
BTL6-U110-M_ _ _ _-PF-S4
Scope of delivery
■ Transducer
■ Mounting clamps with Standard
insulating sleeves and screws nominal stroke [mm]
■ Quick start instructions
0050...4572 mm in 5 mm increments
Please order separately:
Magnet, page 110
See separate catalog for plug connectors:
Industrial networking and connectivity
www.balluff.com 109
Profile PF non-contact
Floating magnet
Distance up to 15 mm
Accessories
(please order separately)
LED for
diagnostics and
Programming
programming
input La
assistance
Programming
input Lb
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Lateral offset: Lateral offset: Lateral offset: Sensor SF
C = ±2 mm C = ±15 mm C = ±2 mm
Accessories
Distance of magnet: Distance of magnet: Distance of magnet:
D = 0.1...4 mm D = 5...15 mm D = 0.1...2 mm
Basic
Information and
Definitions
www.balluff.com 111
Profile PF Inclusive
Captive magnet
guidance system
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Profile P
Profile PF
General data
Analog interface
IO-Link V1.1
Floating Magnet
Captive Magnet
Profile BIW
Please enter the code for the nominal stroke
Rod
in the part number.
Rod Compact
Ordering example: and Rod AR
Swivel eye
Material number 714619
www.balluff.com 113
Micropulse
Transducers
Profile AT
■ In a robust 30-mm pipe housing for universal fastening
■ The cost-effective, contactless position measuring solution
■ Multiple paths – one system, which measures position in many paths
■ With analog output signal and Real-Time Ethernet
114
Profile AT
Contents
AT
General data 116
Analog interface 118
Operating modes 120
Digital pulse interface 122
Ethernet interface 124
Accessories 126
www.balluff.com
www.ballu
balluffff.com
com 115
Profile AT flexible and simple
General data
This product is
certified according to
File No. E227256.
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Installation length
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Mounting cuff,
page 126
Scope of delivery
■ Transducer (select your interface from page 118)
■ Quick start instructions
www.balluff.com 117
Profile AT
Analog interface
Preferred models
BTL6-A110-M_ _ _ _-A1-S115
are available from stock in the nominal strokes
highlighted in blue.
Scope of delivery
■ Transducer
■ Quick start instructions
Ordering example:
Standard
Output signal Characteristic nominal stroke [mm]
Linearity deviation ≤ ±200 μm up to 500 mm nominal stroke ≤ ±200 μm up to 500 mm nominal stroke
Profile P
typ. ±0.02%, max. ±0.04% typ. ±0.02%, max. ±0.04%
500...1500 mm nominal stroke 500...1500 mm nominal stroke Profile PF
Supply voltage 20...28 V DC 20...28 V DC
Current consumption ≤ 70 mA ≤ 70 mA Profile AT
Polarity reversal protected yes yes General data
Operating temperature 0...+70 °C 0...+70 °C Analog interface
Storage temperature –40...+100 °C –40...+100 °C Operating modes
Digital pulse
interface
Ethernet
interface
Accessories
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 119
Profile AT one system two paths
Operating modes
Min. 65 mm
Mode selection
The standard function is the
separate measurement of two
positions. The programming
inputs are used to switch the
mode. The separation between two magnets should
not generally be less than 65 mm.
Minimum Minimum
Magnet separa- Magnet separa-
tion tion
65 mm 65 mm
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 121
Profile AT Self-configuring
Digital pulse interface
P110 interface P111 interface – Cost savings using DPI/IP for start-up and
The P110 interface works with Balluff BTA evaluation units and installation
controllers and modules from various manufacturers, e.g. Siemens, DPI/IP is a protocol for direct data interchange between a controller
B & R, Bosch, Phoenix Contact, Mitsubishi, Sigmatek, Esitron, and transducer. The signal lines are used to send additional informa-
WAGO and others. tion such as manufacturer, measuring length and waveguide gradient.
Reliable signal transmission, even over cable lengths up to 500 m, This allows start-up or replacement of a transducer without having to
between the BTA evaluation unit and the transducer is guaranteed make manual changes to the controller parameters.
by the particularly interference-free RS485 differential drivers and
receivers. Interference signals are effectively suppressed. Features
■ Bi-directional communication
P110 replaces P1 and M1 ■ Position measuring system controller using Init and start/stop
Based on differing philosophies, two controller-specific interfaces signals
have been established for the digital pulse versions. ■ Integrated diagnostic functions
The difference lies in how the edges are processed. The falling ■ Plug and Play
edges are processed in the P interface and the rising edges in the ■ Automatic configuration reduces downtimes.
M interface. To reduce the number of different models to a minimum, ■ Transmission of sensor type, measuring length, specific parameters
the P110 interface was created as a universal pulse interface which ■ Measurement length up to 3,250 mm
combines both functions. The reference point for the propagation
time measurement is the start pulse.
5V Osc.
4/8
bit bus INIT
CPU
controller
P pulse signal
ASIC INFO:
Controller or electronic evaluation unit
+49 7158 173-370
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Please enter code for data protocol and Ordering example: Sensor SF
nominal stroke in the Part number.
BTL6-P11_-M_ _ _ _-A1-S115 Accessories
Preferred models interface P11_
Basic
BTL6-P11_-M_ _ _ _-A1-S115 are available Information and
from stock in the nominal strokes highlighted Standard Definitions
in blue. Data protocol nominal stroke [mm]
Scope of delivery 0 without DPI/IP* 0050 0075 0100 0130 0150 0160 0175
■ Transducer (standard) 0200 0225 0250 0300 0350 0360 0400
■ Quick start instructions 1 with DPI/IP 0450 0500 0550 0600 0650 0700 0750
0800 0850 0900 0950 1000 1100 1200
Please order separately: 1250 1300 1400 1500 1700 2000 2100
Magnet, page 127 2500 2800 3000 3250
Mounting clamps/cuff, page 126 in 25 mm increments on request
Plug connectors, page 232
www.balluff.com 123
Profile AT Real-time Ethernet
Ethernet interface
cost-effective
Profile AT BTL
VARAN bus
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Please enter the code for the Ordering example: Filling Level
nominal stroke in the part number. Sensor SF
BTL6-V11_-M_ _ _ _-A1-S115
Scope of delivery Accessories
■ Transducer
Basic
■ Quick start instructions Standard Information and
Interface Nominal stroke [mm] Definitions
Please order separately:
Magnet, page 127 V VARAN 0160 0175 0200 0225 0250 0275 0300
Mounting clamps/cuff, page 126 E EtherCAT 0325 0350 0360 0375 0400 0425 0450
0475 0500 0550 0600 0650 0700 0750
0800 0850 0900 0950 1000 1100 1200
1250 1300 1400 1500
in 25 mm increments on request
www.balluff.com 125
Profile AT
Accessories
Mounting clamps/cuff
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Micropulse
Transducers
Profile P
Profile PF
Profile AT
General data
Analog interface
Operating modes
Digital pulse
interface
Ethernet
interface
Lateral offset: C = ±5 mm Lateral offset: C = ±5 mm
Accessories
Distance of magnet: Distance of magnet:
D = 4...8 mm D = 4...8 mm
Profile BIW
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 127
Micropulse
position
measuring
Micropulse
system
Transducers
Profile BIW
■ The contactless potentiometer in the compact push rod design
■ With high measurement rate for quick movements
■ The characteristic of the analog output can be inverted via a
programming input
128
Profile BIW
Contents
BIW
General data 130
Analog interface 132
www.balluff.com 129
Profile BIW Contactless potentiometer
General data
Triangular
receiver coil
Position 2
Push rod
Position 3
30 μS
Excitation pulse
Variable Received
oscillations
+10 V +10 V
0 V or 5 V
Output signal
–10 V 0 V
Position 1 Position 2 Position 3
Profile P
Profile PF
Profile AT
Profile BIW
General data
Analog interface
Rod
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
Scope of delivery
■ Transducer
■ Quick start instructions
■ 2 mounting clamps BIW-A-MF01-M-43
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 131
Profile P1 BIW Sampling rate 32 kHz
Analog interface
Properties Series
BIW transducers have these outstanding features: Output signal
■ High resolution and reproducibility Transducer interface
■ Resistance to shock, vibration and noise fields Customer device interface
■ An absolute rising or falling analog output signal Part number
■ A captive sensor element Output voltage Uout
■ Sampling rate 32 kHz Output current IA
■ Potential-free Max. current load per output
■ Non-contact measuring principle System resolution
Repeat accuracy
Sampling rate
Max. linearity deviation
Supply voltage
No-load current consumption
Operating temperature
Storage temperature
Shock load
Vibration
Dielectric strength
Degree of protection as per IEC 60529
Housing material
Fasteners
Connection
Housing length A
Mechanical stroke B
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 133
Micropulse
Transducers
Rod
Rod housings are mainly used in hydraulic drive applications.
When installed in the pressure section of the hydraulic cylinder, the
displacement sensor requires the same pressure rating as the actual
hydraulic cylinder. In practice, the sensor must be able to withstand
pressures up to 1000 bar. The electronics are integrated in an alu-
minum or stainless steel housing and the waveguide in a pressure-
resistant tube made from nonmagnetic stainless steel that is sealed
off at the front end with a welded plug. An O-ring seal in the flange at
the opposite end seals off the high-pressure section. An magnet ring
with magnets slides over the tube or rod with internal waveguide to
mark the position prior to detection.
134
Rod
Contents
BTL7
General data 136
Analog interface 138
Programming 142
SSI interface 144
Programming 146
Digital pulse interface 148
BTL5/BTL6
General data 150
CANopen interface 152
Profibus DP interface 156
Ethernet interface 158
4 programmable switching points 160
Float 162
Magnet 163
Installation notices 164
www.balluff.com 135
Rod BTL7 "long"
General data
up to 7620 mm
13.5 71
Axial cable
Connection KA
48
33
12.8 71
Connector S115
Connection S115
66
41 46
11 71 45
Connector S32
S32 connection Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Style B
(standard design)
Nominal stroke = measuring range Damping zone
BTL7_ _ _ _-B-_ _ _ _ (unusable range)
Magnet
Metric
mounting thread M18×1.5
Thread
M4×4/6
deep
Thread M18x1.5
Micropulse
Mounting surface Transducers
Style Z
Profile P
BTL7_ _ _ _-Z-_ _ _ _ Nominal stroke = measuring range Damping zone
(unusable range)
Magnet Profile PF
3/4" UNF mounting thread
Profile AT
Style Z8 Float
BTL7_ _ _ _-Z8-_ _ _ _ Nominal stroke = measuring range Damping zone
Magnet
(unusable range) Installation
notices
3/4" UNF mounting thread
8 mm protective tube Rod Compact
Max. 1016 mm nominal stroke and Rod AR
Thread
M4×4/6 Rod EX,
deep T Redundant
Thread 3/4"-16UNF and CD
Mounting surface
Filling Level
Sensor SF
Style A
Accessories
BTL7-_ _ _ _-A-_ _ _ _
Nominal stroke = measuring range Damping zone
(unusable range) Basic
Metric mounting thread Information and
Definitions
M18×1.5
Flange without
0.5/Ø 25 mm mounting surface
Thread
M4×4/6
deep
Thread M18x1.5
Mounting surface
www.balluff.com 137
Rod BTL7 Compatible
Analog interface
with BTL5
Temperature coefficient
Supply voltage
Current consumption at 24 V DC
Polarity reversal protected
Overvoltage protected
Dielectric strength
Operating temperature
Scope of delivery
■ Transducer
■ Calibration device
■ Quick start instructions
Rod BTL5/BTL6
General data
CANopen
interface
Profibus DP
interface
Ethernet
interface
4 programmable
switching points
Float
Magnet
Ordering example: Installation
notices
Rod EX,
T Redundant
and CD
Operating Standard nominal
Output signal voltage Characteristic stroke [mm] Design Connection Filling Level
Sensor SF
A 0...10 V 1 24 V 1 rising and 0025...7620 B = Standard S32 Plug connector
Accessories
and 5 10...30 V falling (with in 1 mm increments M18×1.5 S115 Plug connector
10...0 V A and G) Additional designs KA02 PUR cable 2 m
Basic
G –10...10 V 0 rising on page 137 KA05 PUR cable 5 m Information and
and (at C and E) KA10 PUR cable 10 m Definitions
10...–10 V 7 falling (with KA15 PUR cable 15 m
E 4...20 mA C and E)
or
20...4 mA
C 0...20 mA
or
20...0 mA
www.balluff.com 139
Rod BTL7 USB configurable
Analog interface
Temperature coefficient
2 magnets, 2 movements, 2 output signals Supply voltage
Polarity reversal protected
Differential Overvoltage protected
Dielectric strength
Operating temperature
Scope of delivery
■ Transducer
■ Calibration device
■ Quick start instructions
Rod BTL5/BTL6
General data
CANopen
interface
Profibus DP
interface
Ethernet
interface
4 programmable
switching points
Float
Magnet
Installation
notices
Rod Compact
and Rod AR
Rod EX,
T Redundant
Ordering example: and CD
Accessories
Basic
Standard Information and
nominal stroke [mm] Definitions
Output signal Design Connection
www.balluff.com 141
Rod BTL7 Quick
Programming
commissioning
1. Calibration device ■ ■
Teach-in ■
Adjusting ■
Online setting ■
Easy Setup ■
2. Remote setup ■
3. USB configuration ■
Teach-in Adjusting
1. Move the magnet into the new 2. Move the magnet into the new 3. Newly set measurement path
zero position. end position.
Take over new zero value Take over new end value
Remote setting of the start and end points using Lb, pin 8
programming inputs
If the transducer is located in an inaccessible place or a hazardous
area, the start and end point can be adjusted remotely. Teach-in,
adjustment and online setting are identical to programming with La,
pin 4
the calibration device. Button 1, blue, corresponds to programming
Button 1 Button 2
input La and button 2, gray, to input Lb.
24 V
Micropulse
3. USB configuration Transducers
Profile P
Start, end value setting and configuration via USB System requirements
The Micropulse Configuration Tool software allows the quick and ■ Standard PC
Profile PF
easy configuration of Balluff transducers of type BTL7-A/E501... on ■ Operating system: Windows 2000/XP/Vista/7
a PC. ■ Screen resolution at least 1024 × 768 pixels Profile AT
The most important features are: ■ 10 MB available hard disk space
■ Online display of the current position of the magnet ■ Install Java Runtime Environment (JRE) Version 1.4.2 or higher Profile BIW
■ Graphical support for setting the functions and characteristics http://java.com/getjava
■ Display of information about the connected ■ USB port Rod BTL7
transducer General data
■ Selectable number formats and units for display Analog interface
■ Reset to factory settings possible Programming
SSI interface
■ Calibration device can be disabled
Digital pulse
■ Demo mode without having a transducer connected interface
Rod BTL5/BTL6
Connecting the USB communication box General data
For model BTL7-A/E501-M...-S32/S115 transducers, the com- CANopen
interface
munication box can be switched between the transducer and the
Profibus DP
controller. The communication box is connected to the PC using a interface
USB cable. Ethernet
interface
4 programmable
USB communication box switching points
Connecting the communication box
BTL7-A-CB01-USB-S32, with S32 or S115 connector Float
for BTL7-A/E501... with S32 connector Magnet
Installation
notices
BTL7-A-CB01-USB-S115,
for BTL7-A/E501... with Connector S115 Rod Compact
and Rod AR
BTL7-A-CB01-USB-KA,
for BTL7-A/E501... with cable connection Rod EX,
T Redundant
and CD
Scope of delivery
■ USB communication box Communication box connected via cable Filling Level
■ Cable set in the control cabinet Sensor SF
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 143
Rod BTL7 outstanding linear and
SSI interface
synchronous performance
The clock frequency depends on the cable length. Cable length Clock frequency
< 20 m < 1000 kHz
< 50 m < 600 kHz
< 100 m < 330 kHz
< 200 m < 180 kHz
Behavior of LED 1 and the error value over the entire range < 400 m < 90 kHz
SSI LED 1
out Green Normal function
LED The magnet is within the limits
2 21 Red Error
No magnet, or magnet is outside the limits
Magnet
missing
LED 2
~ 5 mm Green Synchronous operation
Internal measurement is synchronous with SSI query
0
Zero point End point Pos
Off Asynchronous operation
Behavior of LED 1 and error value BTL 5 μm Internal measurement is asynchronous with SSI query
Red SSI communication error
LED indicator
T0 or Tm event has occurred
LED 1 LED 2 Flashing Programming mode
green Only with BTL7-S510(B)-...
0 Binary code rising (24-bit) 1 1 μm 0025...7620 mm B = standard M18×1.5 S32 Plug connector Float
1 Gray code rising (24-bit) 2 5 μm in 1 mm increments For additional designs, S115 Plug connector Magnet
6 Binary code rising (25-bit) 3 10 μm see page 137 KA02 PUR cable 2 m Installation
notices
7 Gray code rising (25-bit) 4 20 μm KA05 PUR cable 5 m
A Binary code rising (26-bit) 5 40 μm KA10 PUR cable 10 m
Rod Compact
B Gray code rising (26-bit) 6 100 μm KA15 PUR cable 15 m and Rod AR
7 2 μm
8 50 μm Rod EX,
T Redundant
and CD
Order example BTL7-S Plus:
Filling Level
BTL7-S510-M_ _ _ _-_-_ _ _ _ for asynchronous operation Sensor SF
Basic
Standard Information and
Definitions
nominal stroke [mm] Design Connection
www.balluff.com 145
Rod BTL7
Programming
BTL7-A-CB01-USB-S115,
for BTL7-S/510_ ... with S115 connector Micropulse
Transducers
BTL7-A-CB01-USB-KA,
Profile P
for BTL7-S/510_ ... with cable connection
Profile PF
Profile AT
Profile BIW
Rod BTL7
General data
Analog interface
Programming
SSI interface
Digital pulse
interface
Connecting the communication box
with S32 or S115 connector
Rod BTL5/BTL6
General data
CANopen
interface
Profibus DP
interface
Ethernet
interface
4 programmable
switching points
Rod Compact
and Rod AR
Rod EX,
T Redundant
Caution! and CD
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 147
Rod BTL7 cost-effective
Digital pulse interface
+ synchronous
Profibus BNI modules are an elegant, cost-effective solution P511 interface – Cost savings using DPI/IP for start-up and
from Balluff. installation
The modules have a robust metal housing that was designed for use DPI/IP is a protocol for direct data interchange between a controller
in harsh industrial environments and is capable of withstanding pow- and transducer. The signal lines are used to send additional informa-
erful mechanical loads. The modules have four independent ports for tion such as manufacturer, measuring length and waveguide speed.
Micropulse Transducers BTL with P511. A maximum of 16 magnets This allows start-up or replacement of a transducer without having to
can be used per BTL port. The maximum nominal stroke here is make manual changes to the controller parameters.
7500 mm. Depending on the version, four additional ports with digi-
tal or analog sensors can be assigned. You can achieve maximum Features
functionality and cost efficiency for fieldbus integration by combining ■ Bidirectional communication
Micropulse Transducers BTL with Profibus modules P111. ■ Position measuring system controller using Init and start/stop
signals
For more information, see page 244 ■ Integrated diagnostic functions
■ Plug and Play
■ Automatic configuration reduces downtimes.
Profibus ■ Transmission of sensor type, measuring length, specific
parameters
■ Measuring length up to 3250 mm
8 digital inputs or
4 optional analog inputs
1-15 magnets
5V Osc.
4/8 INIT
bit bus
CPU
controller
P pulse signal
ASIC INFO:
Controller or electronic evaluation unit +49 7158 173-370
Rod BTL7
General data
Analog interface
Programming
SSI interface
Digital pulse
interface
Rod BTL5/BTL6
General data
CANopen
interface
Profibus DP
interface
Ethernet
interface
4 programmable
switching points
Float
Magnet
Please enter code for nominal stroke, Scope of delivery Please order separately: Installation
notices
design and connection in the part number. ■ Transducer Magnets/floats, on page 162
■ Quick start instructions Mounting nuts, on page 163 Rod Compact
Plug connector, on page 232 and Rod AR
Rod EX,
T Redundant
Ordering example: and CD
Standard Accessories
www.balluff.com 149
Rod BTL5 Multitalent
General data
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Style B
Nominal stroke = measuring range Damping zone (unus-
(standard design) able range)
BTL5_ _ _ _-B-_ _ _ _ Magnet
Metric
mounting thread M18×1.5
Thread
M4×4/6
deep
Thread M18x1.5
Mounting surface
Micropulse
Transducers
Style Z
Nominal stroke = measuring range Damping zone (unus- Profile P
BTL5_ _ _ _-Z-_ _ _ _ able range)
Magnet
Profile PF
3/4" UNF mounting thread
Profile AT
Thread
M4×4/6 Profile BIW
deep
Thread 3/4" 16UNF
Rod BTL7
General data
Mounting surface
Analog interface
Programming
SSI interface
Style B8
Nominal stroke = measuring range Damping zone (unus- Digital pulse
BTL5_ _ _ _-B8-_ _ _ _ able range) interface
Float
Style Z8 Magnet
Nominal stroke = measuring range Damping zone (unus- Installation
BTL5_ _ _ _-Z8-_ _ _ _ able range) notices
Filling Level
Mounting surface Sensor SF
Accessories
Style A
Nominal stroke = measuring range Damping zone (unus-
BTL5-_ _ _ _-A-_ _ _ _ able range) Basic
Information and
Definitions
Metric mounting thread
M18×1.5
Flange without
Thread
0.5/Ø 25 mm mounting surface M4×4/6
deep
Thread M18x1.5
Mounting surface
www.balluff.com 151
Rod BTL5
®
Position +
CANopen interface
velocity
5 8
M16x1.5
20
Rod BTL7
General data
Analog interface
Programming
SSI interface
Digital pulse
interface
Filling Level
Software Sensor SF
Standard
configuration Baud rate nominal stroke [mm] Design
Accessories
www.balluff.com 153
Rod BTL5 CANopen®
CANopen® interface
+ 2 analog inputs
The analog process signal from the BTL is converted into digital form
because the analog values from the BTL are only processed in digital
form. The overall conversion time consists of the time the converter
takes to perform the conversion plus additional processing time in
the microcontroller (μC).
The analog values are displayed in the form of a fixed-point number
in the 2's complement. The prefix of the analog value is always in
bit 15.
■ "0" for + CiA 199911-301v30/11-009
■ "1" for -
5 8
M16x1.5
20
Rod BTL7
General data
Analog interface
Programming
SSI interface
Digital pulse
interface
Accessories
A 3-wire voltage, 0 1 Mbaud 0025...4000 mm B = Standard M18×1.5
0...+10 V, 12-bit, 1 800 kbaud in 1 mm increments additional designs, page 151 Basic
Max. 2 inputs 2 500 kbaud Information and
Definitions
C 3-wire current, 3 250 kbaud
0...20 mA, 12-bit, 4 125 kbaud
Max. 2 inputs 5 100 kbaud
E 2 wire current, 6 50 kbaud
4...20 mA, 12-bit, 7 20 kbaud
Max. 2 inputs 8 10 kbaud
www.balluff.com 155
Rod BTL5 Position +
Profibus DP interface
Speed
As the market leading standard for serial data transmission for pro- GSD (device master data)
cess automation, Profibus DP is the ideal choice for implementing The length of the data exchangeable with a slave is defined in the
automation tasks with cycle times of > 5 ms. Device Master Data file (GSD) and is checked by the slave with the
configuration telegram and confirmed for correctness. In modular
Data transmission systems, various configurations are defined in the GSD file. Depend-
A Profibus telegram can contain up to 244 bytes of user data per ing on the desired functionality, one of these configurations can be
telegram and node. The BTL5-T uses max. 32 bytes (max. 4 position selected by the user. The BTL5-T is a modular device with the option
values and max. 4 speed values) for process data transmission. Up of selecting the number of magnets (position values).
to 126 active stations (Addresses 0 to 125) can be connected on
Profibus DP. User data cannot be sent with node address 126. This Process data
address is used as the default address for bus nodes that have to Under Profibus DP, the default is for process data to be sent from
be configured by a Class 2 master (for setting the device address if the master to slaves acyclically and for the slave data to then be
there are no mechanical switches available). queried. To ensure synchronization of multiple devices, the master
Each Profibus station has the same priority. Prioritizing individual may use the SYNC and FREEZE services.
nodes is not intended, but can be done by the master since the bus
transmission only makes up a fraction of the process cycle anyway. DP/V1 and DP/V2 isochronous mode
At a transfer rate of 12 Mbaud, the transmission time for an average Isochronous mode enables quick and deterministic data exchange
data telegram is in the 100 μs range. by means of clock synchronicity on the bus system. A cyclical,
equidistant clock signal is sent by the master to all bus nodes. This
signal allows master and slaves to be synchronized irrespective of
application – with an accuracy < 1 μs.
FMM
The sensor can be operated as a 4-magnet type, whereby the sen-
sor itself recognizes how many magnets are currently active.
Master Class 1 Master class 2
This means that if only two magnets are positioned in the measuring
range, a valid value is output for the first two positions, and an error
value is defined in positions 3 and 4.
5 8
M16x1.5
20
Rod BTL5/BTL6
General data
Please enter code for software configuration, CANopen
interface
nominal stroke and design in the part number.
Profibus DP
interface
Scope of delivery Ethernet
interface
■ Transducer
4 programmable
■ Quick start instructions switching points
Filling Level
Sensor SF
Software Standard
Accessories
configuration nominal stroke [mm] Design
Basic
1 1 × position 0025...4000 mm in 1 mm increments B = Standard M18×1.5 Information and
Definitions
1 × velocity additional designs, page 151
2 2 × position
2 × velocity
www.balluff.com 157
Rod BTL6 Real-time Ethernet
Ethernet interface
cost-effective
VARAN bus
Profile BIW
Rod BTL7
General data
Analog interface
Programming
SSI interface
Digital pulse
interface
Rod BTL5/BTL6
General data
Please enter the code for the nominal stroke in CANopen
interface
the part number.
Profibus DP
interface
Scope of delivery Ethernet
interface
■ Transducer
4 programmable
■ Quick start instructions switching points
www.balluff.com 159
Rod BTL5 simple switching
4 programmable switching points
Thread
M4×4/6
deep
Thread M18x1.5
Mounting surface
Single position measurement between the piston limits on a BTL5-A-EH01 calibration device for programming the
standard cylinder series outputs
Benefits
■ No special design of piston or piston rod necessary
■ No permanent magnet required between the piston seals
■ Easy to program
■ No time-consuming adjustment
■ high resolution and reproducibility
■ Switching points freely programmable using calibration
device or programming inputs
Rod BTL5/BTL6
General data
CANopen
interface
Profibus DP
interface
Ethernet
interface
4 programmable
Please enter code for output signal, nominal switching points
stroke and design in the part number.
Float
Scope of delivery Magnet
■ Transducer Installation
notices
■ Quick start instructions
■ Calibration device Rod Compact
and Rod AR
Please order separately:
Magnets/floats, on page 162 Rod EX,
T Redundant
Mounting nuts, on page 163 and CD
Plug connectors, page 232
Filling Level
Ordering example: Sensor SF
Accessories
BTL5-F1_0-M_ _ _ _-_-S115
Basic
Information and
Standard Definitions
www.balluff.com 161
Rod
Float
Operating temperature/
Storage temperature
æ
æ
æ
æ
ª
Micropulse
Transducers
BAM013M BAM013K
Profile P
Ø 18
Digital pulse
interface
Float
Magnet
Installation
notices
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Accessories
Basic
M18×1.5 Mounting nut Information and
Definitions
Order designation:
BTL-A-FK01-E-M18×1.5
Ordering code: BAM0118
www.balluff.com 163
Rod BTL5
Installation notices
Installation
in hydraulic cylinders
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
Micropulse
Transducers
Profile P
Profile BIW
Rod BTL7
General data
Analog interface
Programming
Servicing a horizontal installation location SSI interface
Digital pulse
interface
Installation
The Micropulse Transducer BTL has a M18×1.5 mounting thread. Rod BTL5/BTL6
We recommend that the mounting be made of non-magnetizable General data
material. If magnetizable materials are used, then the measures CANopen
interface
shown below have to be taken. Sealing is done at the flange mount-
Profibus DP
ing surface, for example, in the B design, with a M18×1.5 thread interface
with an included 15.4×2.1 O-ring. Ethernet
interface
4 programmable
Insertion hole switching points
The transducer comes with an M18×1.5 (according to ISO) or a
3/4"-16UNF (according to SAE) thread to secure it. Depending on Insertion hole M18×1.5, as per ISO 6149, O-ring 15.4×2.1
Float
the version, the threaded hole must be made before installation. Magnet
Installation
notices
Rod Compact
and Rod AR
Rod EX,
T Redundant
and CD
Filling Level
Sensor SF
Basic
Information and
Magnet Definitions
www.balluff.com 165
Micropulse
Transducers
Compact Rod and AR Rod
■ Compact housing with only 34 mm in length saves valuable space
in and around the cylinder.
■ Stainless steel housing with connecting flange and robust 6-screw
fastening (K) – so that no additional protective housing is needed.
■ simple characteristic settings
■ shock and vibration-secure with IP 67/68 degree of protection
■ pressure-resistant housing, for extreme applications offshore or
under water
■ Available with analog signals, digital interfaces and fieldbuses
■ for complete integration in hydraulic cylinders (AR)
166
Compact Rod and AR Rod
Contents
Compact rod
K BTL7, general data 168
H/W BTL7, general data 170
BTL7, general data 172
K BTL5, general data 176
H/W BTL5, general data 178
HB/WB BTL5, general data 180
Analog interface 182
Digital pulse interface 184
SSI interface 186
CANopen interface 188
Installation notices 190
AR BTL6 rod
General data 192
Analog interface 194
Digital pulse interface 196
Installation notices 198
www.balluff.com 167
K BTL7 Compact Rod becomes flat
General data
Stainless steel
BTL7-...-K-SR32 6 Ø 64
30°
Ø 18h6
Ø 10,2
Ø 11
Ø 6.4
86
Thread
Mounting Micropulse
surface Transducers
20.5 25
Profile P
Profile BIW
Ø 11
Ø 6.4
Ø8
Rod
86
Thread Compact rod
K BTL7
H/W BTL7
Mounting BTL7
surface
K BTL5
20.5 25
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
Design K, Design K, BTL7-...-K-K _ _, radial cable outlet interface
BTL7-...-K-SR115 SSI interface
CANopen
interface
Installation
notices
AR BTL6 rod
General data
Analog interface
Digital pulse
interface
Installation
notices
Rod EX,
T redundant
and CD
SF Filling Level
BTL7-...-K-SR115 BTL7...-K-K _ _ Sensor
~18
20
Accessories
Basic
Information and
Definitions
20.5
20.5
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 169
BTL7 Compact H/W Rod "Length"
General data
up to 7620 mm
Design H/W,
BTL7-...-H/W-S32
H: 40-1
12 43 W: 2“-0.04“ 60 Ø 65
0. 5 Ø 25 25
Ø 10,2
10
60
Thread
H: M18×1.5
Mounting W: 3/4"-16 UNF Micropulse
surface Transducers
Profile P
Profile PF
Design H/W, H: 40-1
BTL7-...-H8/W8- 12 43 W: 2“-0.04“ 60 Ø 65
Profile AT
S32, 0. 5 Ø 25 25
Profile BIW
Rod
Ø8
10
60
Rod Compact
Thread K BTL7
H: M18×1.5 H/W BTL7
Mounting W: 3/4"-16 UNF
surface BTL7
K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
interface
Design H/W, SSI interface
CANopen
BTL7-...-H/W-S115 interface
10
Installation
notices
Rod AR BTL6
General data
20
Analog interface
Digital pulse
interface
Design H/W, Installation
notices
BTL7-...-H/W-KA
10
SF Filling Level
20 Sensor
Accessories
Basic
Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 171
Rod Compact BTL7 Measurement
General data
rate to 4 kHz
Scope of delivery
■ Transducer
■ Quick start instructions
■ Stainless steel fastening screws "600 bar"
before
after
Rod Compact BTL7 Rod Compact BTL7 Rod Compact BTL7 Rod Compact BTL7
analog analog analog analog
A G E C
analog analog analog analog
BTL7-A510-M_ _ _ _-_-_ _ _ _ BTL7-G510-M_ _ _ _-_-_ _ _ _ BTL5-E5_0-M_ _ _ _-_-_ _ _ _ BTL7-C5_0-M_ _ _ _-_-_ _ _ _
0...10 V and 10...0 V –10...10 V and 10...–10 V
4...20 mA or 20...4 mA 0...20 mA or 20...0 mA
Max. 5 mA Max. 5 mA
≤ 500 ohms ≤ 500 ohms
≤ 0.33 mV ≤ 0.33 mV ≤ 0.66 μA ≤ 0.66 μA
System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm Micropulse
Max. 4 kHz Max. 4 kHz Max. 4 kHz Max. 4 kHz Transducers
±50 μm to ≤ 500 mm nominal stroke ±50 μm to ≤ 500 mm nominal stroke ±50 μm to ≤ 500 mm nominal stroke ±50 μm to ≤ 500 mm nominal stroke
Profile P
±0.01% FS > 5500 mm nominal stroke ±0.01% FS > 5500 mm nominal stroke ±0.01% FS > 5500 mm nominal stroke ±0.01% FS > 5500 mm nominal stroke
±0.02% FS > 5500 mm nominal stroke ±0.02% FS > 5500 mm nominal stroke ±0.02% FS > 5500 mm nominal stroke ±0.02% FS > 5500 mm nominal stroke Profile PF
≤ 30 ppm/K ≤ 30 ppm/K ≤ 30 ppm/K ≤ 30 ppm/K
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC Profile AT
≤ 150 mA ≤ 150 mA ≤ 150 mA ≤ 150 mA
to 36 V to 36 V to 36 V to 36 V Profile BIW
to 36 V to 36 V to 36 V to 36 V
500 V AC (ground to housing) 500 V AC (ground to housing) 500 V AC (ground to housing) 500 V AC (ground to housing) Rod
–40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C
Rod Compact
K BTL7
H/W BTL7
BTL7
K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
interface
SSI interface
CANopen
interface
Installation
notices
Ordering example:
Rod AR BTL6
General data
BTL7-_5_0-M_ _ _ _-_ _-_ _ _ _
Analog interface
Digital pulse
interface
Installation
notices
Output Charac- Standard nominal
Rod EX,
signal teristic stroke [mm] Design Connection T redundant
and CD
A 0...10 V 1 rising and 0025...7620 in K 10.2 mm protective tube K-radial design
and falling (at 1 mm increments K8 8 mm protective tube K02 PUR cable 2 m SF Filling Level
Sensor
10...0 V A and G) H 10.2 mm protective tube K05 PUR cable 5 m
G –10...10 V 0 Rising (with H8 8 mm protective tube K10 PUR cable 10 m Accessories
and C and E) W 10.2 mm protective tube K15 PUR cable 15 m
10...–10 V 7 Falling W8 8 mm protective tube SR32 Plug connector Basic
(at C and I) SR115 Plug connector Information and
E 4...20 mA Definitions
or
20...4 mA H/W radial design H/W design, axial
C 0...20 mA K02 PUR cable 2 m KA02 PUR cable 2 m
or K05 PUR cable 5 m KA05 PUR cable 5 m
20...0 mA K10 PUR cable 10 m KA10 PUR cable 10 m
K15 PUR cable 15 m KA15 PUR cable 15 m
S32 Plug connector
S115 Plug connector
www.balluff.com 173
BTL7 Compact Rod Characteristic
General data
100% adjustable
Calibration box
Teach-in
The factory-set zero and end points are replaced by new zero and
end points. The zero and end points can be set independently of before
each other, and the characteristic slope changes.
after
Reset
New end point
Restoring the transducer to its factory default settings.
Profile AT
Profile BIW
Rod
Rod Compact
K BTL7
H/W BTL7
BTL7
K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
The BTL Compact integrated Digital pulse
in the hydraulic cylinder of a interface
hydraulically actuated servo drive SSI interface
CANopen
guarantees safe, reliable and interface
perfect control of the flow. Installation
notices
Rod AR BTL6
General data
Analog interface
Digital pulse
interface
Installation
notices
Rod EX,
T redundant
and CD
SF Filling Level
Sensor
Accessories
Basic
Information and
Definitions
www.balluff.com 175
Rod Compact K BTL5 Stainless steel
General data
Magnet
Micropulse
M4×4/6 deep
Transducers
internal thread,
lock washer
Ø 9 DIN 6799 Profile P
BKS-S 33M
Profile PF
Profile BIW
Rod
Rod EX,
T redundant
and CD
SF Filling Level
Sensor
Accessories
Basic
Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 177
Rod Compact H/W BTL5 Stainless steel
General data
Hardware design, 21
BTL5-...-M_ _ _ _-H-K_ _
0.5 Nominal stroke = measuring range 60
ca. 42
Mounting Damping zone
ca. 20 (unusable range)
thread M18×1.5 Internal thread
M4×4/6 deep
Ø 10.2
Radial cable outlet Magnet
Micropulse
Transducers
Profile P
35 25 Mounting surface Ø 65
Profile PF
Profile AT
Ø 10.2
M4×4/6 deep
Mounting Magnet
thread M18×1.5 Rod Compact
Cable outlet K BTL7
H/W BTL7
axial
BTL7
10
K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
43 25 Mounting surface Ø 65 interface
ca. 20 SSI interface
CANopen
interface
Installation
H/W housing, 0.5 Nominal stroke = measuring range 60
notices
BTL5-...-M_ _ _ _-H-S32 Damping zone
(unusable range) Rod AR BTL6
Internal thread
M4×4/6 deep General data
Ø 10.2
Rod EX,
T redundant
and CD
Basic
Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 179
Rod ProCompact HB/WB BTL5 The outdoor system
General data
IP 67K, 40 bar
Application areas:
■ Locks and floodgates
■ Water power plants
■ Large, hydraulically powered valves
■ Positioning the reflection channels
for thermosolar power plants
■ Dredger
■ Railway track
■ Logging machines
■ Hydroelectric power stations
■ Construction machinery
■ Combine harvesters
Series Adapter
Ordering code BAM01JW
Part number BAM AD-XA-007-M18×1.5/D12-2
Housing material Brass (not seawater-resistant)
Ordering code BAM01JY
Part number BAM AD-XA-007-M18×1.5/D12-4
Housing material Stainless steel V2A (conditionally seawater-resistant)
Series Protective hose
Part number BAM PT-XA-001-095-0-_ _ _
Tube length 02, 05, 10, 15, 20, 30, 50 and 100 m
Degree of protection IP 68 (40 bar)
IP 67K (in installed and screwed-on state)
Adapter Housing material PUR (resistant to seawater, weld spatter and UV radiation)
Outer diameter 16 mm
Protective hose Inside diameter 9.5 mm
Temperature range –40...+95 °C
Bending radius min. (static) 51 mm
Rod
Contact surface
AR BTL6 rod
General data
Analog interface
Digital pulse
HB/WB housing interface
BTL5-...-HB/WB-_ _ _ _-C Installation
notices
radial
HB: 30 mm
WB: 2"
Rod EX,
T redundant
Nominal stroke = measuring range Damping zone (unus- and CD
able range)
M4×4/6 deep
Magnet Internal thread SF Filling Level
Sensor
Accessories
Mounting surface
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 181
Compact Rod The outdoor system
Analog interface
IP 67K, 40 bar
Scope of delivery
■ Transducer
■ Quick start instructions
BTL5 Compact rod BTL5 Compact rod BTL5 Compact rod BTL5 Compact rod
analog analog analog analog
A E C G
analog analog analog analog
BTL-A11-M_ _ _ _-HB/WB-_ _ _ _ BTL-E1-M_ _ _ _-HB/WB-_ _ _ _ BTL-C1-M_ _ _ _-HB/WB-_ _ _ _ BTL-G11-M_ _ _ _-HB/WB-_ _ _ _
0...10 V and 10...0 V –10...10 V and 10...–10 V
4...20 mA or 20...4 mA 0...20 mA or 20...0 mA
Max. 5 mA Max. 5 mA
≤ 5 mV ≤ 5 mV
≤ 500 ohms ≤ 500 ohms
≤ 0.1 mV ≤ 0.2 μA ≤ 0.2 μA ≤ 0.1 mV Micropulse
≤ 4 μm ≤ 4 μm ≤ 4 μm ≤ 4 μm Transducers
AR BTL6 rod
General data
Analog interface
Digital pulse
interface
Installation
notices
Ordering example:
Rod EX,
BTL5-E1_-M_ _ _ _-_ _-_ _ _ _-C T redundant
and CD
SF Filling Level
Sensor
Standard Accessories
Output signal nominal stroke [mm] Design Connection
Basic
0025...5500 Radial output Information and
1 rising and falling HB Definitions
(at A and G) in 1 mm increments WB F05 5 m Teflon cable
0 Rising Axial output
7 decreasing KA05 5 m Teflon cable
(with C and E)
www.balluff.com 183
Compact Rod compact and
Digital pulse interface
cost-effective
P Interface
The P interface is compatible with BTA evaluation units as well as
with controllers and modules from various manufacturers including
Siemens, B & R, Phoenix Contact, Mitsubishi, Sigmatek, Parker,
Esitron, WAGO and others.
Reliable signal transmission, even with cable lengths of up to 500 m
between the BTA evaluation unit and the BTL transducer. This is
guaranteed by the especially interference-proof RS485 differential
drivers and receivers. Interference signals are effectively suppressed.
SSD
4/8-bit INIT
Bus
CPU
controller
P pulse signal
ASIC INFO:
+49 7158 173-370
Profile BIW
Rod
Compact rod
K BTL7
H/W BTL7
BTL7
K BTL5
H/W BTL5
Please enter code for nominal stroke, HB/WB BTL5
design and connection in the part number. Analog interface
Digital pulse
Scope of delivery interface
■ Transducer SSI interface
CANopen
■ Quick start instructions interface
Installation
Please order separately: notices
Magnet/float, page 162
AR BTL6 rod
Mounting nut, page 163 (for Rod Compact H)
General data
Plug connector, page 232
Analog interface
Digital pulse
Ordering example: interface
Installation
notices
BTL5-P1-M_ _ _ _-_-_ _ _ _
Rod EX,
Standard T redundant
nominal stroke [mm] Design Connection and CD
www.balluff.com 185
Rod Compact
SSI interface
The clock frequency depends on the cable length. Cable length Clock frequency
< 25 m 1000 kHz
< 50 m 500 kHz
< 100 m 400 kHz
< 200 m 200 kHz
< 400 m 100 kHz
Ordering example:
System Standard
Coding resolution nominal stroke [mm] Design Connection
Profile BIW
Rod
Rod Compact
K BTL7
H/W BTL7
BTL7
K BTL5
Please enter code for coding, Scope of delivery Please order separately:
H/W BTL5
system resolution, nominal stroke, design ■ Transducer Magnet/float, page 162 HB/WB BTL5
and connection in the part number. ■ Quick start Mounting nut, page 163 Analog interface
instructions Plug connector, page 232 Digital pulse
Ordering example: interface
SSI interface
CANopen
BTL5-S1_ _-M_ _ _ _-_-_ _ _ _ for asynchronous operation interface
BTL5-S1_ _B-M_ _ _ _-_-_ _ _ _ for synchronous operation Installation
notices
Rod AR BTL6
General data
Analog interface
System Standard nominal
Digital pulse
Coding resolution stroke [mm] Design Connection interface
Installation
notices
0 Binary code, 1 1 μm 0025...4000 mm in K Radial output
rising (24-bit) 2 5 μm 1 mm increments K02 PUR cable 2 m
Rod EX,
1 Gray code, ris- 3 10 μm K05 PUR cable 5 m T redundant
ing (24-bit) 4 20 μm K10 PUR cable 10 m and CD
6 Binary code, 5 40 μm K15 PUR cable 15 m
SR32 Plug connector SF Filling Level
rising (25-bit) 6 100 μm Sensor
7 Gray code, ris- 7 2 μm
ing (25-bit) H Radial output Accessories
W K02 PUR cable 2 m
K05 PUR cable 5 m Basic
Information and
K10 PUR cable 10 m Definitions
K15 PUR cable 15 m
Axial output
KA02 PUR cable 2 m
KA05 PUR cable 5 m
KA10 PUR cable 10 m
KA15 PUR cable 15 m
S32 Plug connector
www.balluff.com 187
Rod Compact
CANopen® interface
CiA 199911-301v30/11-009
Ordering example:
Rod
Rod Compact
Please enter code for software configuration, K BTL7
H/W BTL7
baud rate, nominal stroke and design in the
BTL7
part number. Cable on request.
K BTL5
H/W BTL5
Scope of delivery HB/WB BTL5
■ Transducer Analog interface
■ Quick start instructions Digital pulse
interface
Please order separately: SSI interface
CANopen
Magnet/float, page 162 interface
Mounting nut, page 163 Using the CANopen interface and a cable up to 2500 m in length, the signal is Installation
Plug connector, page 232 sent at a length-dependent baud rate to the controller. The high interference notices
immunity of the connection is achieved using differential drivers and by the data
Rod AR BTL6
monitoring implemented in the data protocol.
General data
Ordering example:
Analog interface
Digital pulse
BTL5-H1_ _-M_ _ _ _-_-_ _ _ _ interface
Installation
notices
Rod EX,
Software Standard nominal T redundant
Connection and CD
configuration Baud rate stroke [mm] Design
SF Filling Level
1 1 × position and 0 1 Mbaud 0025...4000 mm in K Radial output Sensor
1 × speed 1 800 kbaud 1 mm increments K02 PUR cable 2 m
2 2 × position and 2 500 kbaud K05 PUR cable 5 m Accessories
2 × speed 3 250 kbaud SR92 Plug connector
3 4 × position 4 125 kbaud Basic
Information and
5 100 kbaud H Radial output Definitions
6 50 kbaud W K02 PUR cable 2 m
7 20 kbaud HC K05 PUR cable 5 m
8 10 kbaud
Axial output
KA02 PUR cable 2 m
KA05 PUR cable 5 m
S92 Plug connector
www.balluff.com 189
Rod Compact H/K/W BTL5/7
Installation notices
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
Micropulse
Transducers
Installation of BTL5 Rod Compact W
Profile P
The Micropulse Transducer BTL has a M18×1.5 mounting thread.
We recommend that the mounting is made of non-magnetizable
Profile PF
material.
If magnetizable materials are used, then the measures shown below Profile AT
have to be taken. Sealing is at the flange mounting surface using the
supplied 15.4×2.1 O-ring with M18×1.5 thread. Profile BIW
Rod
Rod Compact
Countersink for O-ring, Tapped hole K BTL7
3/4" 16 UNF thread
H/W BTL7
BTL7
Magnet K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
interface
SSI interface
CANopen
Spacer made of non-magnetizable material interface
Installation
notices
Installation BTL5 Rod Compact K
Rod AR BTL6
The Micropulse Transducer has 6 mounting holes for cylinder head
Countersink for O-ring
General data
screws (ISO 4762 M6×18 A2-70).
Analog interface
We recommend that the holder is made of non-magnetizable mate-
Digital pulse
rial. If magnetizable materials are used, the measures described interface
15.4×2.1
thru-hole
SF Filling Level
Sensor
1-2 with magnetizable material
4 with non-magnetizable material Accessories
A Spacer made of non-magnetizable
material Basic
Information and
B Magnet Definitions
www.balluff.com 191
Rod AR BTL6 Mobile hydraulics
General data
e1 type approval
The e1 type approval is granted
by the German Federal Motor
Transport Authority (Kraftfahrt-
Bundesamt, or KBA). It confirms
that special motor vehicle stan-
dards have been maintained.
The devices may be mounted on
vehicles which travel on public
roads. The standards describe
EMC conditions under which the
devices must operate without
failure. e1 approved Micropulse
Transducers are indicated by
"-SA265-" in the part number.
Design E2/E28
BTL6-...-E2/E28-_ _ _ _-KA
Nominal stroke = measuring range Damping zone
(unusable range)
Cable outlet
axial centric Magnet
Thread
Micropulse
B C Transducers
BTL6-A/B 25.2 13
BTL6-E 29.75 13 Profile P
BTL6-P 25.2 16
A G Profile PF
E2 10.2 Thread M4×4/6 deep
Profile AT
E28 8 without thread
Profile BIW
Rod
Design E2/E28
BTL6-...-E2/E28-_ _ _ _-LA Rod Compact
Nominal stroke = measuring range Damping zone
(unusable range) K BTL7
H/W BTL7
Cable outlet
Magnet BTL7
axial with
K BTL5
stranded wire
H/W BTL5
Thread HB/WB BTL5
Analog interface
Digital pulse
interface
SSI interface
B CANopen
BTL6-A/B 25.7 interface
BTL6-E 30.25 Installation
notices
BTL6-P 25.7
A G Rod AR BTL6
E2 10.2 Thread M4×4/6 deep General data
E28 8 without thread Analog interface
Digital pulse
interface
Installation
notices
Design E2/E28
Rod EX,
BTL6-...-E2/E28-_ _ _ _-KE T redundant
Nominal stroke = measuring range Damping zone and CD
(unusable range)
Cable outlet
SF Filling Level
axial eccentric Magnet Sensor
Accessories
Thread
Basic
Information and
Definitions
B C
BTL6-A/B 25.2 13
BTL6-E 29.75 13
BTL6-P 25.2 16
Caution! A G
Please read the instructions in the user's guide before E2 10.2 Thread M4×4/6 deep
designing, installing, and commissioning! www.balluff.de E28 8 without thread
www.balluff.com 193
Rod AR BTL6
Analog interface
Ordering example:
Standard nominal
Output signal stroke [mm] Design Connection
Axial output
LA00,3 PUR stranded wire, 0.3 m
Rod AR BTL6
General data
Analog interface
Digital pulse
interface
Installation
notices
Please enter code for output signal, nominal stroke,
design and connection in the part number.
Rod EX,
T redundant
Scope of delivery and CD
■ Transducer
SF Filling Level
■ Quick start instructions Sensor
www.balluff.com 195
Rod AR BTL6
Digital pulse interface
P510 interface
The 510 interface is compatible with BTA evaluation units as well as
with controllers and modules from various manufacturers including
Siemens, B & R, Bosch, Phoenix Contact, Mitsubishi, Sigmatek,
Parker, Esitron, WAGO and others.
Reliable signal transmission, even with cable lengths of up to 500 m
between the BTA evaluation unit and the transducer. This is guaran-
teed by the especially interference-proof RS485/differential drivers
and receivers. Interference signals are effectively suppressed.
Benefits
■ High resolution: the actual 1 μm of the BTL position measuring
system is supported completely by the 133 ps resolution of the
chip (at low clock frequency 2 or 20 MHz).
■ Position data from 4 magnets can be processed
simultaneously
■ 4/8-bit processor interface
5V Osc.
CPU
controller
P pulse signal
Profile BIW
Rod
Rod Compact
K BTL7
H/W BTL7
Please enter code for nominal stroke,
BTL7
design and connection in the part number.
K BTL5
H/W BTL5
Scope of delivery HB/WB BTL5
■ Transducer Analog interface
■ Quick start instructions Digital pulse
interface
Please order separately: SSI interface
CANopen
Magnet/float, page 162 interface
Installation
notices
Ordering example:
Rod AR BTL6
General data
BTL6-P510-M_ _ _ _-_ _ _-_ _ _ _ _
Analog interface
Digital pulse
interface
Standard nominal Installation
notices
stroke [mm] Design Connection
Rod EX,
0050...1524 mm E2 Protective tube Axial output T redundant
Ø 10.2 mm KA02 PUR cable 2 m and CD
in 1 mm increments
E28 Protective tube KA05 PUR cable 5 m
SF Filling Level
Ø 8 mm, max. KA10 PUR cable 10 m Sensor
Nominal stroke KA15 PUR cable 15 m
1016 mm KA20 PUR cable 20 m Accessories
Axial output
LA00,3 PUR stranded wire, 0.3 m
www.balluff.com 197
Rod AR BTL6 Plug & Play
Installation notices
1 13
Ø 4.4
Con- 3
nector
insert
O-ring
for perfect Connector
sealing flange
Connector insert Connector
engaged in con- view
nector flange
20
5
3
20
M12x1
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
1 Magnet
Profile P
Magnet
2
Profile PF
Fixing the transducer
using three M5 set Profile AT
screws at an angle of
120 °C Profile BIW
Rod
Spacer made of non-magnetizable material
Rod Compact
K BTL7
H/W BTL7
3 Magnet
BTL7
K BTL5
H/W BTL5
HB/WB BTL5
Analog interface
Digital pulse
interface
SSI interface
non-magnetizable material
CANopen
interface
4 Installation
notices
Rod AR BTL6
General data
Analog interface
Digital pulse
interface
1 Installation on the piston, in magnetic piston material Installation
notices
2 Installation from rear, in magnetizable piston material
3 Installation on the piston
Rod EX,
4 Installation on piston in a cylinder with articulated lug T redundant
and CD
SF Filling Level
Sensor
Accessories
Basic
Information and
Definitions
www.balluff.com 199
Micropulse
Transducers
Rod EX Rod CD
■ For use in a potentially explosive environment ■ Pressure-resistant up to 1000 bar – the sensor for high-pressure
■ With IECEx, ATEX, FM, and many other international hydraulic units
approvals ■ M22x1.5 mounting thread with 12.7 mm pressure pipe
■ Different solutions in accordance with the requirements ■ Measuring lengths up to 2000 mm in millimeter increments
■ With a slim, robust stainless steel design ■ Shock- and vibration-resistant with high degree of protection,
■ Can also be used as a filling level sensor for robust use
■ Available with analog signals, digital interfaces, fieldbuses, and
Rod T Redundant Real-Time Ethernet
200
Rod EX, T, CD
Contents
Rod EX
Filling level sensor in zone 0/1 202
Transducer in zone 1 203
Rod DEX, general data 204
Rod J-DEXC, general data 207
Rod PEX, general data 210
Rod NEX, general data 211
Floats and magnets 212
Rod T Redundant
General data 214
Programming 218
Magnet 219
Rod CD
General data 220
www.balluffff.com
www
www.balluff.com
com 201
Rod EX Compact housing
Filling level sensor in zone 0/1
BTL5-_1-M....-B-DEXA-_ _ _
Rod version "DEXA" is the safe and reliable approach for filling level
applications in Zone 0. A cotter pin prevents the float from getting
lost. Float, see page 212.
Applications
■ Filling stations
■ Tank systems
■ Refineries
■ Chemical industry
■ Pharmaceuticals
Zone 1
Zone 0
Installation examples
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
BTL5-_1-M....-B-DEXB-_ _
The BTL can be used to sense the position of a hydraulic piston
directly without making contact, even up to pressures of 600 bar.
The BTL is threaded into the head of the cylinder. The measurement
section enters a hole drilled deep into the piston.
Applications
■ Actual value monitoring in hydraulic cylinders
■ Valve adjustment in power plants
■ Filling units
■ Positioning spray guns Micropulse
transducers
Profile P
Profile PF
Installation
The Micropulse transducer BTL has a M18×1.5 mounting thread. Profile AT
We recommend that the mounting is made of non-magnetizable
material. Profile BIW
If magnetizable materials are used, the measures described above
have to be taken. Sealing is at the flange mounting surface using the Rod
supplied O-ring 15.4×2.1 with M18×1.5 thread.
Rod Compact
and Rod AR
Rod EX
Filling level
sensor
in zone 0/1
Countersink for O-ring
Transducer in
zone 1
Rod DEX
Rod J-DEXC
Rod PEX
Rod NEX
Floats
and
magnets
Tapped hole
per ISO 6149
Rod T
Redundant
General data
Programming
Magnet
Rod CD
General data
Accessories
Basic
information and
definitions
www.balluff.com 203
Rod DEX Flameproof
General data
IECEx
Pressure-resistant up to 600 bar, high reproducibility, Transducers from category II 1/2 G designated Ex d IIB+H2 T6 meet
contactless, robust the requirements for electrical equipment in areas containing poten-
The Micropulse transducer BTL is a robust position feedback tially explosive gases. Requirements for areas containing flammable
system for measuring ranges between 25 and 4000 mm as well as dust are also fulfilled in accordance with category II 3D designated
use under extreme ambient conditions. Ex tD IP 67 T85°C, A zone 22.
Zone 1
partition
Zone 0
Scope of delivery
■ Transducer
■ User's Guide
60 B: 30
Nominal stroke = measuring range Damping zone
(unusable range)
Thread
Magnet M4×4, 6 deep
Profile P
Safety stop
Mounting surface BTL5...B-DEXA-KA_ _
Profile PF
Profile AT
Profile BIW
Rod
Rod Compact
and Rod AR
Model J, flange Ø 18 mm, pitch circle Ø 76.2 mm,
Cable outlet radial Rod EX
60 J: 30 Filling level
Nominal stroke = measuring range Damping zone sensor
(unusable range) in zone 0/1
Thread Transducer
Magnet M4×4, 6 deep in zone 1
Rod DEX
Rod J-DEXC
Short safety stop Rod PEX
BTL5...J-DEXB-K_ _ Rod NEX
Floats
and
magnets
Rod CD
General data
Filling Level
Sensor SF
Accessories
Basic
information and
definitions
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
www.balluff.com 205
Rod DEX
General data
Analog interface no zero- or end-point setting possible; see technical data on page 182
Ordering example:
Output signal Standard nominal stroke [mm] Design Rod end Connection
A11 0...10 V and 10...0 V 0025...4000 mm B A Float safety Axial cable outlet
rising and falling in 1 mm increments J stop only for model B, Z
E10 4...20 mA, rising Z KA02 PUR cable 2 m
E17 20...4 mA, falling B Short safety KA05 PUR cable 5 m
C10 0...20 mA, rising stop KA10 PUR cable 10 m
C17 20...0 mA, falling KA15 PUR cable 15 m
G11 –10...10 V and
10...–10 V rising and falling Radial output
K02 PUR cable 2 m
K05 PUR cable 5 m
K10 PUR cable 10 m
K15 PUR cable 15 m
BTL5-_1-M_ _ _ _-_-DEX_-_ _ _ _
System Standard
Coding resolution nominal stroke [mm] Design Rod end Connection
0 Binary code, rising (24-bit) 1 1 μm See above B A Float safety See above, analog
1 Gray code, rising (24-bit) 2 5 μm analog interface DEX J stop interface DEX
6 Binary code, rising (25-bit) 3 10 μm Z
7 Gray code, rising (25-bit) 4 20 μm B Short safety
5 40 μm stop
The Micropulse transducer J-DEXC has been specially developed for Fields of application
use in potentially explosive atmospheres. The important demands of ■ Hydraulically or pneumatically actuated valves
the oil and gas industry for high reliability and ease of servicing are ■ Clutch travel monitoring for compressors
combined in the J-DEXC system. ■ Level monitoring
J-DEXC comprises a robust flameproof Ex housing and an electron- ■ Level control
ics module that is easily accessible and exchanged for servicing. ■ Actual value sensing in hydraulic cylinders in Ex areas
Spare electronics modules can be ordered from Balluff Service
department.
Rod CD
General data
Please order separately:
Magnet, page 212 Filling Level
Sensor SF
Float, page 212
Accessories
Basic
information and
Class I, Division 1, Groups A, B, C, and D definitions
Class II, Division 1, Groups E, F, and G; Class III
T6 Ta=65°C, T5 Ta=80°C Type 4X/6P; IP 68
C US
Class I, Zone 1 AEx d IIC T6 Ta=65°C, T5 Ta=80°C
11-2411253X Class I, Zone 1 Ex d IIC T6 Ta=65°C, T5 Ta=80°C
SIRA 11ATEX1104X
IECEx SIR 11.0048X
II 1/2GD
Ex d IIC T6/T5 Ga/Gb Ta +65°C (T6) +80°C (T5)
Ex t IIIC T85/T100°C Da IP 68 Ta +65°C (T85) +80°C (T100)
0518
www.balluff.com 207
Rod J-DEXC-TA12
General data
Magnet
Thread
1/2" 14 NPT
Mounting surface
Cable gland
1/2" - 14 NPT to
M20 metric
BTL-A-AD09-M-00EX
M20 thread
A51 0...10 V and 10...0 V 0025...4000 mm TA12 Internal thread 1/2" 14 NPT
Rising and falling in 1 mm increments
E50 4...20 mA, rising
E57 20...4 mA, falling
C50 0...20 mA, rising
C57 20...0 mA, falling
G51 –10...10 V and
10...–10 V rising and falling
System Standard
Coding resolution nominal stroke [mm] Connection
0 Binary code, rising (24-bit) 1 1 μm Analog interface J-DEXC TA12 Internal thread 1/2" 14 NPT Micropulse
1 Gray code, rising (24-bit) 2 5 μm transducers
6 Binary code, rising (25-bit) 3 10 μm
7 Gray code, rising (25-bit) 4 20 μm Profile P
5 40 μm
Profile PF
Profile AT
CANopen interface, see technical data on page 152/153
Ordering example: Profile BIW
Rod Compact
and Rod AR
Standard
Software configuration Baud rate nominal stroke [mm] Connection Rod EX
Filling level
1 1 × position and 0 1 Mbaud Analog interface J-DEXC TA12 Internal thread 1/2" 14 NPT sensor
in zone 0/1
1 × velocity 1 800 kbaud Transducer
2 2 × position and 2 500 kbaud in zone 1
2 × velocity 3 250 kbaud Rod DEX
4 125 kbaud Rod J-DEXC
5 100 kbaud Rod PEX
Rod NEX
6 50 kbaud
Floats
7 20 kbaud and
8 10 kbaud magnets
Rod T
redundant
Profibus DP interface, see technical data on page 154/155 General data
Ordering example: Programming
Magnet
BTL5-T1_ 0-M_ _ _ _-J-DEXC-TA12
Rod CD
Standard General data
Software configuration nominal stroke [mm] Connection
Filling Level
Sensor SF
1 1 × position and Analog interface J-DEXC TA12 Internal thread 1/2" 14 NPT
1 × velocity Accessories
2 2 × position and
2 × velocity Basic
information and
definitions
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
www.balluff.com 209
Rod PEX Dust protection zone
General data 22 II 3 D T 90°C X
Digital pulse interface, for technical data refer to the user's guide
Ordering example:
BTL5-P1-M_ _ _ _-_-PEX-KA02
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
Profile P
Profile PF
A11 0...10 V and 10...0 V 0025...4500 mm SR32 with connector plug Rod EX
E10 4...20 mA, rising in 1 mm increments K05 PUR cable 5 m Filling level
E17 20...4 mA, falling sensor
in zone 0/1
C10 0...20 mA, rising
Transducer
C17 20...0 mA, falling in zone 1
Rod DEX
Rod J-DEXC
Stainless steel Rod PEX
Rod NEX
Floats
and
magnets
Rod CD
Output signal Standard nominal stroke [mm] Design Connection General data
A510 0...10 V and 10...0 V 0025...0500 mm B M18×1.5 S32 with connector plug Filling Level
Sensor SF
E500 4...20 mA, rising in 1-mm increments Z 3/4" 16 UNF S115 with connector plug
E570 20...4 mA, falling CD M22×1.5 KA05 PUR cable 5 m Accessories
C500 0...20 mA, rising high-pressure resistant
C570 20...0 mA, falling Basic
information and
definitions
www.balluff.com 211
Rod EX
Floats and magnets
Orientation:
Raised dimple on upper side of float
BTL2-S-4414-4Z01-Ex
Ordering code: BAM0148
Cylindrical float, zone 0, density of float ρ = 0.85 g/cm3 for separation
layer measurement
Orientation:
2 raised dimples on upper side of float
Interface
A second float can be added to measure the position of the interface
between two liquids, such as oil and condensed water.
Suitable: BTL2-S-4414-4Z01-Ex.
BTL2-A-DH01-E-32-Ex
Spacer sleeve for the float:
BTL2-S-4414-4Z-Ex
BTL2-S-4414-4Z01-Ex
BTL2-S-5113-4K-Ex
The sleeve is included.
Caution!
Please read the instructions in the user's guide before
designing, installing and commissioning! www.balluff.de
BTL2-S-5113-4K-Ex
Ordering code: BAM014A
Ball float, zone 0 permitted up to density ρ ≥ 0.7 g/cm3
Orientation:
Raised dimple on upper side of float
BTL2-S-6216-8P-Ex
Ordering code: BAM014E
Parabolic float, permitted up to ρ ≥ 0.6 g/cm3 Micropulse
transducers
Profile P
Profile PF
Profile AT
Float model Immersion depths given ρ = 1 g/cm3(H2O) Immersion depths given ρ = 0.7 g/cm3 Profile BIW
BTL2-S-6216-8P-Ex ss ~ 41 mm ss ~ 57 mm
Rod
BTL2-S-5113-4K-Ex ss ~ 26 mm ss ~ 40 mm
BTL2-S-4414-4Z-Ex ss ~ 30 mm ss ~ 39 mm
Rod Compact
BTL2-S-4414-4Z01-Ex ss ~ 45 mm submerges and Rod AR
Rod CD
General data
Filling Level
Sensor SF
Accessories
Basic
Information and
Definitions
www.balluff.com 213
Rod Redundant
General data
Pressure-resistant up to 600 bar, high reproducibility, Up to three independent position measuring systems in the same
redundant, contactless housing enable fail-safe linear measurement of, for example, safety
BTL7 redundant Micropulse transducers: the robust position mea- valves or the combined monitoring of position and adjustment
suring system for use in safety-related valves and hydraulic cylinders speed.
for measuring ranges between 25 and 7620 mm.
Design TB Micropulse
Metric mounting thread M18×1.5 transducers
Protective tube Ø10.2 mm
Profile P
Design TZ Mounting surface TB: 30-1 mm
TZ: 2"-0.04" Damping zone 1)
English mounting thread ¾" UNF
Protective tube Ø10.2 mm Nominal stroke = 60 Profile PF
Measuring range
TB3/TZ3
Ø max. 7 Profile AT
Ø 10.2
Magnets 2)
Profile BIW
Ø 70
M16x0.75
Rod
3)
Thread size:
1) TB: M18x1.5 Rod Compact
TZ: 3/4" 16 UNF and Rod AR
0.5 Ø 30 Ø 74
~20
M4x4/6 deep
12.5 ~80 25 Rod EX
Filling level
Thread
sensor
Mounting surface in zone 0/1
Design TT TT: 30-1 mm TT3 Transducer
Metric mounting thread M30×1.5 in zone 1
Rod DEX
Ø 21
Rod NEX
Floats
and
magnets
Design TK Rod CD
Flange Ø18 mm General data
Mounting surface
Pitch circle Ø64 mm Damping zone 1)
Protective tube Ø10.2 mm Filling Level
TK: 40-1 mm Nominal stroke = 60
Sensor SF
Measuring range TK3
Ø max. 7 1)
Ø 10.2
Accessories
Magnet 2) LED
Basic
Ø 70
Ø 48
Information and
M16x0.75
Definitions
3)
Ø18h6
34 Ø 74
~20 Adapter 4) Thread
12.5 ~80 25 BAM AD-TL-012-B/K-4 M4x4/6 Ø 79
(M18×1.5 on Ø18h6) deep
www.balluff.com 215
Rod Redundant reliable 3 in 1
General data
Ordering example:
Rod Redundant BTL7 Rod Redundant BTL7 Rod Redundant BTL7 Rod Redundant BTL7
analog analog Analog Analog
A G E C
Analog Analog Analog Analog
BTL7-A504-M_ _ _ _-_-_ _ _ _ BTL7-G504-M_ _ _ _-_-_ _ _ _ BTL5-E504_0-M_ _ _ _-_-_ _ _ _ BTL7-C504_0-M_ _ _ _-_-_ _ _ _
0...10 V -10...10 V
4...20 mA 0...20 mA
Max. 5 mA Max. 5 mA
≤ 500 ohms ≤ 500 ohms
≤ 0.33 mV ≤ 0.33 mV ≤ 0.66 μA ≤ 0.66 μA
System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm System resolution/min. 2 μm Micropulse
transducers
Max. 500 Hz Max. 500 Hz Max. 500 Hz Max. 500 Hz
±200 μm to ≤ 500 mm nominal stroke ±200 μm to ≤ 500 mm nominal stroke ±200 μm to ≤ 500 mm nominal stroke ±200 μm to ≤ 500 mm nominal stroke
Profile P
±0.04% FS > 500 mm nominal stroke ±0.04% FS > 500 mm nominal stroke ±0.04% FS > 500 mm nominal stroke ±0.04% FS > 500 mm nominal stroke
≤ 40 ppm/K ≤ 40 ppm/K ≤ 20 ppm/K ≤ 20 ppm/K Profile PF
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
≤ 150 mA ≤ 150 mA ≤ 150 mA ≤ 150 mA Profile AT
to 36 V to 36 V to 36 V to 36 V
to 36 V to 36 V to 36 V to 36 V Profile BIW
500 V AC (ground to housing) 500 V AC (ground to housing) 500 V AC (ground to housing) 500 V AC (ground to housing)
–40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C Rod
Rod Compact
and Rod AR
Rod EX
Filling level
sensor
in zone 0/1
Transducer
in zone 1
Rod DEX
Rod J-DEXC
Rod PEX
Rod NEX
Floats
and
magnets
Rod T
Redundant
General data
Programming
Magnet
Rod CD
General data
Please enter code for output signal, nominal stroke,
design, and connection in the part number.
Filling Level
Sensor SF
Scope of delivery
■ Transducer Accessories
■ Quick start instructions
■ Fastening screws, stainless steel, "600 bar" (only design TK) Basic
Information and
■ Adapter flange (only design TK) Definitions
www.balluff.com 217
Rod Redundant
Programming
System requirements
■ Standard PC
■ Operating system: Windows 2000/XP/Vista/7
■ Screen resolution at least 1024 × 768 pixels
■ 10 MB available hard disk space
■ Install Java Runtime Environment (JRE) Version 1.4.2 or higher
http://java.com/getjava
■ USB port
Description
for Series
USB configuration Ordering code
Part number
Start, end value setting and configuration via USB Material
The software called Micropulse Configuration Tool enables Weight
Balluff transducers of type BTL7-A/E50... to be quickly and easily Magnet travel speed
configured on a computer. Operating temperature/Storage temperature range
The most important features are: Ordering code PA 60 glass fiber reinforced
■ Online display of the current position of the magnet Part number PA 60 glass fiber reinforced
■ Graphic support for setting the functions and Material
characteristics Weight
■ Display of information about the connected transducer Magnet travel speed
■ Selectable number formats and units for display Operating temperature/Storage temperature range
■ Reset to factory settings possible
■ Demo mode without having a transducer connected
BTL7-A-CB01-USB-S32,
for BTL7-A/E504/505... with S32 connector Connecting the communication box
with S32 or S115 connector
BTL7-A-CB01-USB-KA,
for BTL7-A/E504/505... with cable connection
Scope of delivery
■ USB communication box
■ Cable set
■ Quick start instructions
Rod J-DEXC
Rod PEX
Rod NEX
Floats
and
ª magnets
Rod T
Redundant
General data
Programming
Magnet
Rod CD
General data
Filling Level
Sensor SF
Accessories
Basic
Magnet Spacer made of non-magnetizable material Information and
Definitions
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 219
Rod CD 1000 bar
General data
High-pressure resistant
Heavy-duty cylinders raise the bridge to the planned road level after they are
"floated" into position.
Mounting surface
Damping zone
31-1 mm 1)
60
Ø 12.7
1)
Thread M4×4/6 deep
Magnet 2)
46
25 Profile P
0.2
Housing: Anodized aluminum Profile AT
23.8+0.1
4
Profile BIW
120°
Rod
Ø 28.5
Ø 39
Ø 18
Rod Compact
and Rod AR
Ø 4.3 Rod EX
8 2.4+0.4
Filling level
sensor
Ø8 in zone 0/1
Transducer
The transducer has a mounting thread M22×1.5 (according to in zone 1
ISO). Depending on the version, the hole must be tapped before Rod DEX
installation. Rod J-DEXC
Please enter code for output signal, nominal stroke, Rod PEX
design and connection in the Part number. Rod NEX
Magnet Floats
and
Scope of delivery magnets
■ Transducer
■ Quick start instructions Rod T
Redundant
General data
Please order separately: Programming
Calibration box, page 174 Magnet
Magnet, page 219 Spacer made of non-magnetizable material
Rod CD
Ordering example: General data
Accessories
Basic
Information and
Output signal Nominal stroke [mm] Definitions
NEX Connection
Analog interface, see page 138; SSI interface, see page 144;
digital pulse interface, see page 148; NEX, see page 211
www.balluff.com 221
Micropulse
Transducers
Filling Level Sensor SF
■ Highly accurate filling level sensor
■ Compensation for inaccuracies due to foam build-up
■ With international approvals, such as 3-A Sanitary Standard, FDA
and ECOLAB
■ In stainless steel housing with Tri Clamp fastener
■ Safe for sterilization (SIP) and cleaning (CIP)
222
Filling Level Sensor SF
Contents
www.balluff.com 223
Filling Level Sensor SF 100% stainless steel
General data
The FDA (Food and Drug Administration) oversees the U.S. food and
drug industries and certifies devices, materials as well as systems
in these industries. A product designation of this kind makes your
system eligible for FDA approval.
IP69K
Caution!
Please read the instructions in the user's guide before
designing, installing, and commissioning! www.balluff.de
www.balluff.com 225
Filling Level Sensor SF
Analog interface
Scope of delivery
■ Transducer
■ Quick start instructions
Filling level
sensor SF
General data
Analog interface
Floats and
accessories
Accessories
Basic
Information and
Definitions
Ordering example:
BTL5-_1_-M_ _ _ _-SF-_ _ _
www.balluff.com 227
Filling Level Sensor SF
Floats and accessories
IP69K
Process temperature:
maximum permissible temperature of
120 °C – the rod under the flange (with media
130 °C contact).
Certain production processes
require sterilization at 120...130°C for
0.5...1 hour, for instance.
Included in scope of delivery for float
■ Float
■ Instructions
■ Cotter pin (spring pin 2×30)
Caution!
Approvals only issued through use of these components.
Please read the instructions in the user's guide before
designing, installing, and commissioning!
■ Continuously precise measurement in μ area delivers excellent Maximum precision for food hygiene –
filling results internationally certified
■ 100% stainless steel ensures top hygiene standards and long The filling level sensor BTL-SF ensures continuously precise mea-
service life surement in applications that have extreme hygiene requirements.
■ International certificates ensure maximum quality Made from corrosion-free stainless steel with excellent surface
quality and rounded edges, the sensor meets the highest interna-
tional hygiene standards and fulfills all of the food industry's strict
requirements. Take advantage of the best quality directly from the
manufacturer.
Rod Compact
and Rod AR
Rod EX,
T redundant
and CD
Filling level
sensor SF
General data
Analog interface
Floats and
accessories
Accessories
Basic
Information and
Definitions
www.balluff.com 229
Micropulse
Transducers
230
Accessories
Contents
Accessories
Connectors 232
Evaluation units 242
Profibus P111 modules 245
BUS interface modules 248
Digital display, CAM controller 249
www.balluff.com 231
Accessories
Connectors
PIN Color
1 YE
2 GY
3 PK
4 RO
Connectors 5 GN
6 BU
for CANopen 7 BN
8 WH
CiA 199911-301v30/11-009
Profile BIW
Rod
PIN Color PIN Color PIN Color PIN Color PIN Color
1 YE 1 YE 1 YE 1 YE 1 YE
2 GY 2 GY 2 GY 2 GY 2 GY Compact rod
3 PK 3 PK 3 PK 3 PK 3 PK and AR rod
4 RO 4 RO 4 RO 4 RO 4 RO
5 GN 5 GN 5 GN 5 GN 5 GN
6 BU 6 BU 6 BU 6 BU 6 BU Rod EX,
7 BN 7 BN 7 BN 7 BN 7 BN T redundant
8 WH 8 WH 8 WH 8 WH 8 WH and CD
Filling level
sensor SF
Accessories
Connectors
Evaluation
units
Profibus
modules P111
Stainless steel BUS interface
modules
Digital display
CAM controller
Basic
information and
definitions
www.balluff.com 233
Accessories
Connectors for CANopen and DeviceNet interfaces
CANopen
1 2
DeviceNet
1 3 2
1
3
2 Slot 3
Power supply for DeviceNet:
BKS-S48-15-CP-... page 239
T-splitter, 2 × female, 1 × male 5-pin, female 5-pin, male Terminating resistor, male Male/female extension
BKS-S92-TA1 BKS-S137-19-PC-... BKS-S151-19-PC-... BKS-S94-R01 BKS-S92-16/GS92-_ _
Micropulse
5×0.25 mm2 5×0.25 mm2 5×0.34 mm2 transducers
IP 67 IP 67 IP 67 IP 68 IP 67
Profile P
CuZn CuZn CuZn CuZn CuZn
2.5 μm Ni 2.5 μm Ni 2.5 μm Ni 2.5 μm Ni 2.5 μm Ni Profile PF
HBR Viton Viton Viton Viton
121 ohms Profile AT
A A A A A
1* 1 2 2 1/2 Profile BIW
Rod
Compact rod
and AR rod
PIN Signal
1 – Rod EX,
2 – T redundant
3 – and CD
4
121 ohms
5
Filling level
sensor SF
*Only for Please include the Please include the Please include the
BTL5-H1...-M-P/B-S92 cable length with the part cable length with the part cable length with the part Accessories
number. number. number. Connectors
02 = Length of 2 m 02 = Length of 2 m 02 = Length of 2 m Evaluation
units
05 = Length of 5 m 05 = Length of 5 m 05 = Length of 5 m Profibus
10 = Length of 10 m 10 = Length of 10 m 10 = Length of 10 m P111 modules
BUS interface
modules
Digital display
CAM controller
Basic
information and
definitions
Order designation:
BTL5-A-CP01-K
www.balluff.com 235
Accessories
M8 Y-connectors for CANopen
A B C D
BKS12 Ø13.5 12 7.5 M12×1
Filling level
*Knurled ring used Previously BKS-S 105-00 Previously BKS-S 106-00 Previously BKS-S 103-00 Previously BKS-S 104-00 sensor SF
for shielding 00,3 = Length of 0.3 m 00,3 = Length of 0.3 m 00,3 = Length of 0.3 m 00,3 = Length of 0.3 m
Accessories
02 = Length of 2 m 02 = Length of 2 m 02 = Length of 2 m 02 = Length of 2 m
Connectors
05 = Length of 5 m 05 = Length of 5 m 05 = Length of 5 m 05 = Length of 5 m
Evaluation
10 = Length of 10 m 10 = Length of 10 m 10 = Length of 10 m 10 = Length of 10 m units
Profibus
P111 modules
Ø20.2 20.2 BUS interface
Ø20.2 M12×1 41.8 Ø20.2 M12×1 36.7 modules
Digital display
CAM controller
Basic
18 information and
54.9
57.4
56.0
definitions
63.7
18 18
Profibus DP
1 3 2
1
3
2
www.balluff.com 237
Accessories
Connector for M12. 5-pin, B-coded for Profibus DP
Configuration
Design
Use Female/male Female
Supply voltage US 300 V 300 V
Cable material PUR PUR
Color Violet Violet
Number of conductors × conductor cross-section 2×0.38 mm2 2×0.38 mm2
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature range Ta –25...+80 °C –25...+80 °C
Housing material PUR PUR
Knurled ring Nickel-plated CuZn Nickel-plated CuZn
Coding B B
Slot on transducer 1/2 1
1 NC
2 Line A green 4
3 NC 3 1
4 Line B red
5 NC
–25...+80 °C –40...+85 °C
Profile P
PUR Plastic PUR
Nickel-plated CuZn Profile PF
B B
2 2 3 Profile AT
Profile BIW
Rod
Compact rod
BCC0711 BCC0069 and AR rod
BCC M415-0000-2B-031-PS72N1-020 BKS-S 48-15-CP-02
BCC0712 BCC006A Rod EX,
BCC M415-0000-2B-031-PS72N1-050 BKS-S 48-15-CP-05 T redundant
and CD
BCC0713 BCC006C
BCC M415-0000-2B-031-PS72N1-100 BKS-S 48-15-CP-10 Filling level
sensor SF
Accessories
Connectors
Evaluation
BCC0718 units
BCCM415-0000-2B-R01 Profibus
modules P111
BUS interface
Previously BKS-S105-CP-_ _ modules
00,3 = Length of 0.3 m Digital display
CAM controller
02 = Length of 2 m
05 = Length of 5 m Basic
10 = Length of 10 m Information and
Definitions
www.balluff.com 239
Accessories
M12 female straight and right-angle connectors, 8-pin,
customized assembly
Adapter BKS-S115 to
BKS-S 32
Ordering code
BKS-S115/GS32-PU-00.2
M12 female, straight, 8-pin M12 female, angled, 8-pin M12/M18 Y-plug splitter
BCC04MC BCC050F BCC0CK4
BCC M478-0000-1A-000-43X834-000 BCC M488-0000-1A-000-43X834-000 BCC_M418-M314-M415-V0038-000 Micropulse
–25...+85° C –25...+85° C –25...+85° C transducers
CuZn CuZn TPU
Profile P
CuZn
Galv. Au
Profile PF
IP 67 (when screwed into place) IP 67 (when screwed into place) IP 67 (when screwed into place)
GD-Zn Profile AT
Compact rod
and AR rod
4...8 mm 4...8 mm
Rod EX,
I = A, III = D T redundant
and CD
C
2 2
3 3 2 Filling level
8 8
1 4 1 4 5 sensor SF
1 3
7 7
5 5
6 6
4 Accessories
Connectors
2 4 Evaluation
1 3 units
Profibus
P111 modules
2 3 BUS interface
1 8 4 modules
7 5 Digital display
6 CAM controller
Basic
Information and
15.2 9 Definitions
M8x1 13 11 13.8
31.8
18
45˚
45
˚
Ø14
M12x1 13
www.balluff.com 241
Accessories
Analog evaluation units
Filling level
sensor SF
Accessories
Connectors
Evaluation
units
Profibus
P111 modules
BUS interface
modules
Digital display
CAM controller
Basic
Information and
Definitions
www.balluff.com 243
Accessories
Analog and digital evaluation units
Ordering examples:
BTM-H1-_ _ _ BTM-_1-_ _ _
Output driver
Output signal Versions
240 Source driver (PNP with
short circuit protection A 0...10 V, 10...0 V 101 1 analog output, 1 magnet
10...30 V) and 24-bit –10...10 V, 10...–10 V 102 2 analog outputs, 2 magnets
synchronous serial data E 4...20 mA, 20...4 mA 103 3 analog outputs, 3 magnets
transmission (SSI) 0...20 mA, 20...0 mA 104 4 analog outputs, 4 magnets
340 Tri-state TTL output
and 24-bit synchronous BTM-_1-102-VM1000
serial-data transmission
(SSI)
Output signal Versions Speed
Digital Analog
inputs inputs
1.8
Information and
Definitions
The modules have a robust metal housing designed for use in harsh
industrial environments and capable of withstanding extremely high
mechanical stresses. The module is fitted with four interdependent
ports for Micropulse transducers BTL with a P111 or M1 pulse
interface. A maximum of 16 magnets can be used per BTL port. The
224
209
224
209
UD US UD US BUS UD US UD US BUS
0 1 0 1
0 1 0 1
25
0 1 0 1 0 1 0 1
25
25
4 5 4 5
30.5 25
6 7 6 7
6.5
68 68
www.balluff.com 245
Accessories
Profibus modules P111 for BTL
Design 8-pin, female 8-pin, female 8-pin, pin, female 8-pin, pin, female
Use 8-pin, pin 8-pin, pin for Profibus modules for Profibus modules
for Profibus modules for Profibus modules BNI-PBS 0-3 BTL BNI-PBS 0-3 BTL
BNI-PBS 0-3 BTL BNI-PBS 0-3 BTL
Part number BIS Z-501-PU1-_ _/E BIS Z-502-PU1-_ _/E BIS Z-501-PU1-_ _/M BIS Z-502-PU1-_ _/M
Connector M12 M12 M12 M12
Cable diameter 6.9 mm 6.9 mm 6.9 mm 6.9 mm
Degree of protection* as per IEC 60529 IP 67 when attached IP 67 when attached IP 67 IP 67
Number of conductors × 8×0.25 mm2 8×0.25 mm2 8×0.25 mm2 8×0.25 mm2
conductor cross-section
Ambient temperature range –40...+85 °C –40...+85 °C –40...+85 °C –40...+85 °C
Plug in BKS-S117-00 BKS-S117-00
M12 pin scope of delivery
Cable One end molded-in, other One end molded-in, other Both ends molded-on Both ends molded-on
end pigtailed end pigtailed
61
61
M12x1
M12x1 Ø20
Ø20
Please include the cable length with the Please include the cable length with the
part number: part number:
0,5 = Length 5m 00,5 = Length 0.5 m
10 = Length 10 m 01 = Length 1m
20 = Length 20 m 02 = Length 2m
25 = Length 25 m 05 = Length 5m
50 = Length 50 m
Profibus
8 digital inputs or
4 optional analog inputs
Micropulse
transducers
Profile P
1-15 magnets
Profile PF
Profile AT
Profile BIW
Rod
Compact rod
and AR rod
Rod EX,
T redundant
and CD
Filling level
sensor SF
Accessories
Connectors
Evaluation
units
Profibus
P111 modules
BUS interface
modules
Digital display
CAM controller
Basic
Information and
Definitions
www.balluff.com 247
Accessories
BUS interface modules WAGO/Phoenix Contact
WAGO digital pulse interface 750-635 for BTL5-P1-_ _ Phoenix Contact IMPULSE-IN terminal for BTL5-P1-_ _
or BTL6-P1_ _- or BTL6-P1_ _-
The digital pulse interface was developed for connecting Micropulse The IB IL IMPULSE-IN is a terminal from the Inline product family by
transducers (BTL5-P1-...). The RS422 interface ensures quick and Phoenix Contact and is used for evaluating Micropulse transducers
interference-free signal transmission with a resolution down to 1 μm. with a pulse interface.
The absolute position of the Micropulse transducer is sent to the The IMPULSE-IN terminal enables particularly cost-effective solutions
supervisory controller as a 24-bit value. because it senses the positions using a low-cost pulse interface. In
The controller can perform a zero point shift and configure the num- addition, the pulse interface has the advantage of real time capabil-
ber of magnets. ity, making it especially suitable for applications with position or
The bus terminal with a digital pulse interface can be operated by all bearing control.
bus drivers of the WAGO-I/O-SYSTEM 750, except the Economy
variants. Interfaces:
■ Inter-Bus
Interfaces ■ Profibus DP
■ Inter-Bus ■ CANopen
■ Profibus DP ■ DeviceNet
■ CANopen ■ Ethernet
■ DeviceNet
■ Ethernet TCP/IP Further technical details and orders from:
■ Modulbus
■ CC-Link Phoenix Contact
GmbH & Co. KG
Resolution: 1 μm Number of magnets configurable (1...4) Flachsmarktstrasse 8
32823 Blomberg
Further technical details and orders from: Phone +49 5235-300
Fax +49 5235-341200
WAGO E-mail: info@phoenixcontact.com
Kontakttechnik GmbH www.phoenixcontact.com
Hansastrasse 27
32423 Minden
Phone +49 571 887-0
Fax +49 571 887-169
E-mail: info@wago.com
www.wago.com
Series BDD-UM 3023 BDD-AM 10-1-P BDD-AM 10-1-SSD BDD-CC 08-1-P BDD-CC 08-1-SSD
Digital display Digital display Digital display CAM controller CAM controller
for analog input signals for BTL5-P with for BTL5-S with for BTL5-P with for BTL5-S with
Current / voltage P Interface SSD interface P Interface SSD interface
Part number BDD-UM 3023 BDD-AM 10-1-P BDD-AM 10-1-SSD BDD-CC 08-1-P BDD-CC 08-1-SSD
Features ■ 4-digit display with ■ 7 1/2-digit display with ■ 8 programmable outputs
leading sign leading sign ■ 8 directional switching points
■ LED display, 14 mm-high, ■ LED display, 14 mm-high, possible
red 7-segment digits red 7-segment digits ■ LED display, six 14-mm high
■ Programmable decimal point ■ Scalable measured values red 7-segment digits
■ 12-bit AC/DC converter ■ Variable decimal point setting ■ Switching points can be Micropulse
■ Measurement range selection ■ Adjustable zero point monitored using the LEDs on transducers
■ Voltage input of 0...10 V ■ Supply voltage of 10...32 V front panel
Profile P
■ Current input of 0/4...20 mA ■ 2 programmable relay ■ 300 switching points can be dis-
■ Scalable display range outputs, each as limit switch/ tributed over up to 15 programs
Profile PF
comparator ■ Adjustable top dead center/
■ Cam zero point shift Profile AT
■ 2-point controller ■ Dynamic dead time com-
■ 1 configurable input pensation for each individual Profile BIW
■ External zeroing switching point
■ Retention of the display value ■ Multiple BDD-CC 08 units can Rod
■ Insulated DIN housing for be wired in parallel
mounting in front panel ■ Integrated transducer supply Compact rod
and AR rod
(clamp included in the scope voltage 300 mA, 24 V
of delivery) ■ Insulated DIN housing for Rod EX,
mounting in front panel (clamp T redundant
and CD
included in the scope of delivery)
Filling level
sensor SF
Accessories
Connectors
Evaluation
units
Profibus
module P111
BUS interface
modules
Digital display
CAM controller
Housing depth 55.5 mm Housing depth 110 mm Housing depth 110 mm
Basic
Information and
Definitions
www.balluff.com 249
Micropulse
Transducers
250
Basic Information and Definitions
Contents
www.ballu
www.balluff.com
balluffff.c
com 251
Basic Information and Definitions
Definitions
Output signal, characteristic The characteristic curve describes the relationship between the
curve, resolution, sensitivity output signal and the input signal. The slope of the curve represents
the sensitivity of the device.
The sensitivity (resolution) is the quotient of the input signal change
and the change in the output signal. On Micropulse transducers, the
input signal change is the change in the position of the magnet and
the output signal change is the change in the electrical output signal.
Linearity
deviation
Linearity deviation A linearity deviation is the maximum deviation from a straight line that
connects the zero point of a measuring range with the end point (full
scale). There is a linear relationship between the position or path to
be measured and the output signal for a voltage, current or digitized
output information. The linearity characteristic curve of magnetostric-
tive transducers does not change during the life of the system. The
curve, however, can be corrected.
Measurement
section
Travel
Turn-on point
Specified position
Repeat accuracy is the value resulting when moving to the same po-
Repeat accuracy sition from the same direction under unchanging ambient conditions.
SYNC mode The absolute positioning information of the position measuring sys-
tem is determined and transmitted synchronously to the read cycle
of the electronic evaluation unit, e.g. an axis controller or a regulating
controller.
Incremental After the system is switched on, the measured value currently avail-
able is not defined. A reference run to a defined point, a reference
point, is necessary in order to obtain a position value. The position
value is calculated by adding or subtracting individual, equal incre-
ments from the reference point. Micropulse
transducers
Profile P
Absolute The measured value for the current position is available immediately
after the system is switched on. An absolute coded digital signal or
Profile PF
an analog value is assigned to each position, e.g. along a measure-
ment section. A reference run is not required. Profile AT
Profile BIW
Temperature coefficient, The temperature coefficient is the relative change of a physical
formula variable with changing temperature. The temperature Rod
dependency of variable y can be approximated at least
for a limited temperature range by using temperature Compact rod
and AR rod
coefficient α with linear relationship y = y0 (1 + α ×ΔT).
Rod EX,
T Redundant
and CD
Temperature coefficient The temperature coefficient indicates the relative change
in length as temperature changes. This means that tem-
SF filling level
perature factors change the output value by the indicated sensor
amount.
Accessories
Zero point The zero point is the position with the lowest output Basic
Information and
value along the measuring range. The zero point can be Definitions
set by the user for some transducer models. The zero Definitions
point must lie within the measuring range. Designs
Interfaces
Sampling rate The sampling rate is the frequency at which the output information
is updated. It can be the same as the number of measurements
per second. A high sampling rate for rapidly changing positions is
important if a process is time-critical.
Rated length The rated length is the usable area, i.e. the available path/length
measurement range (also see the characteristic curve). The rated
length is always shorter than the overall length of the transducer.
Damping zone The damping zone is the area in which the second (undesired)
magnetostrictive wave is damped. This area is always outside of the
measuring range. Depending on the transducer model, either an er-
roneous output signal or an error signal will be output if the magnet
is allowed to travel into this zone, which must not be considered
valid information.
www.balluff.com 253
Basic Information and Definitions
Definitions
Intrinsically safe "i" A circuit is intrinsically safe if it does not permit a spark or thermal
Coding "Ex i" effect that could ignite an explosive atmosphere as defined by Group
IIA, IIB or IIC, whereby the test conditions prescribed in the standard
must be applied. The test conditions take into account normal op-
eration and certain fault conditions.
The implementation of intrinsically safe circuits results in certain
restrictions pertaining to the selection of components for electrical
and electronic circuits.
In addition, the permissible load on the components as compared
with normal industrial applications must be reduced:
■ for the voltage in terms of electrical stability, and
■ for the current in terms of heating
Flameproof encapsulation "d" Parts that could ignite a potentially explosive atmosphere must be
Coding "Ex d" housed in an enclosure:
■ that can withstand the pressure resulting from the
explosion of an explosive mixture inside the housing, and
■ that prevents the internal explosion from igniting the
potentially explosive atmosphere surrounding the housing.
Non-incendive "n" Devices in this category are intended for use in areas where an
Coding "Ex n" explosive atmosphere is not expected. Even if the atmosphere were
to become explosive, in all probability it would be infrequent and only
for a short period of time.
A manufacturer's certificate is provided, confirming that the product
satisfies requirements for the use of electrical equipment in poten-
tially explosive areas according to EN 60079-15.
This designation combines multiple methods of ignition protection.
e1 type approval e1 type approval is granted by the German Federal Motor Transport
Authority (KBA) and confirms that special motor vehicle standards
have been maintained. e1
The devices may be mounted on vehicles that travel on public roads.
The standards describe EMC conditions under which the devices
must operate without failure. e1 approved Micropulse transducers
are indicated by "-SA265-" in the part designation.
FDA The FDA (Food and Drug Administration) oversees the U.S. food and
drug industries and certifies devices, materials as well as systems
in these industries. A product designation of this kind makes your
system eligible for FDA approval.
Filling level sensor The magnetostrictive working principle is also ideal for the continu-
ous high-precision measurement of fluid filling levels. The measuring
section and electronic evaluation unit are enclosed inside a housing
ousing
made from stainless steel. Stainless steel floats with permanent nt
integrated magnets mark the current filling level in the tank or vessel.
The design of the sensors meets international hygiene standards. ds.
Micropulse
transducers
Profile P
Profile PF
Profile AT
Profile BIW
Rod
Compact rod
and AR rod
Rod EX,
T redundant
and CD
SF filling level
sensor
Accessories
Basic
Information and
Definitions
Definitions
Designs
Interfaces
www.balluff.com 255
Basic Information and Definitions
Interfaces
Micropulse
Synchronous serial CANopen DeviceNet transducers
interface (SSI)
Profile P
The position of the magnet along the mea- The position of the magnet along the mea- DeviceNet is a fieldbus network that permits
surement section is sent to the controller suring section is sent over the CAN bus to communication between basic sensors/
Profile PF
serially in a data word. the controller in what are known as Process actuators as well as programmable logic
Micropulse transducers with an SSI inter- Data Objects or PDOs. controllers. Profile AT
face can be connected directly to control- Micropulse transducers work with standard Micropulse transducers transmit the
lers or to axis control cards with an SSI CANopen protocols as per CiA DS 301 absolute position and the velocity to the Profile BIW
interface. The transmission of data from and with the standard device profile as per controller in the form of a 4-byte value with
the sensor to the controller is synchronized DS406. CANopen offers greater flexibility a maximum cycle time of 1 ms. Rod
by the controller's clock. Transducers with because of the large number of configura- The communication parameters and the ob-
16, 24 or 25-bit data words are available tion options for the transducer. jects available to the Micropulse transducer Compact rod
and AR rod
depending on the required resolution. For example, the resolution is program- can be parameterized using the electronic
The ±30 μm maximum linearity deviation mable for 5, 10, 20 or 100 μm – depending device data sheet (EDS file). Rod EX,
of the SSI Micropulse transducer over the on your application. Alternatively you can T redundant
and CD
entire length, the max. 5 kHz update fre- select whether both position and velocity
quency and a resolution of 1 μm make SSI information is to be sent to your controller.
SF filling level
Micropulse transducers an ideal feedback Cyclically or on-demand. sensor
sensor – even in the most demanding posi- And there's more: Up to 4 so-called
tioning and control applications. software cams can be defined in the active Accessories
measuring range. Each status change to
one of these cams is transmitted to the Basic
Information and
controller using high-priority emergency Definitions
messages. Definitions
Designs
Interfaces
www.balluff.com 257
Basic Information and Definitions
Interfaces
Micropulse
IO-Link EtherCAT transducers
Profile P
IO-Link is a point-to-point connection within Micropulse position measuring systems with
any network. An IO-Link system consists an EtherCAT interface are the ideal nodes
Profile PF
of an IO-Link device such as a sensor or in an EtherCAT network when dealing with
actuator, an IO-Link master and wiring. The controlling and positioning with precision Profile AT
IO-Link master is either an integrated/modu- down to the micrometer.
lar IP 20 module for central operation in the Multi-position capable up to 16 axes, path Profile BIW
control cabinet or as a remote IO module and speed, monitored working ranges with
in IP 65/67 form of protection for tough ap- diagnostics: These characteristics are used Rod
plications directly in the field. in automation and drive technology.
Master modules are available with all cur- EtherCAT is an Ethernet-based bus system. Compact rod
and AR rod
rent field bus protocols. The Micropulse The protocol is disclosed as the IEC61188
PF IO-Link device is coupled to the master type 12 (EtherCAT) IEC standard and is Rod EX,
via a maximum 20 m long standard sensor/ suitable for hard and soft real time require- T redundant
and CD
actuator line. The Micropulse PF IO-Link ments. The structure of the standard Ether-
works at COM3 communication speed net frame sent by the master is structured
SF filling level
(230kB), which can achieve a process data according to IEEE 802.3. EtherCAT slave sensor
cycle of 1 ms with a 1.1 master. devices take the data intended for them
Data transmission between the master and while the telegram goes through the device. Accessories
the device utilizes three-conductor physics Likewise, input data is inserted into the
well-known in the world of standard sensor/ telegram as it goes through the device. This Basic
Information and
actuators. A standard UART protocol is results in short cycle times that can be sig- Definitions
used. The exact nature of the data packets nificantly below 100 μs, making them ideal Definitions
defines the IO-Link protocol. Via IO-Link, for application areas in drive and automa- Designs
the user interface can be mapped based tion technology. EtherCAT offers extensive Interfaces
on an IODD (IO Device Description) in the diagnostic options with precise and quick
engineering system. Due to the continuous error detection.
flow of information, all data is centrally and
permanently saved, so that configuration is
possible and reproducible at any time. More
information about IO-Link:
www.io-link.com.
www.balluff.com 259
Inductive
Position
Sensors
Inductive position sensors are typically used in automation equip-
ment and toolmaking wherever adjustment values and positions
have to be monitored in very tight spaces.
260
Inductive Position Sensors
Contents
SMARTSENS
Basic information
and definitions
can be found on
page 280.
www.balluff.com 261
Inductive Position Sensors
Applications
BIL
Balluff magneto-inductive position sensors detect positions up
to 160 mm away. Analog position sensors BIL measure without
contact and absolutely using a passive magnet. The compact
design means these sensors can be easily integrated into the ap-
plication even when mounting space is extremely tight.
Micro-BIL
The Micro-BIL detects the absolute position on pneumatic miniature
grippers or compact cylinders using integrated permanent magnets;
the sensor element can be easily
installed in the T-slot. The analog output signal allows you to indi-
vidually and flexibly detect end-of-travel and intermediate positions
on gripper jaws or pistons.
BIP
The inductive positioning system BIP is an accurate measuring
system for detecting the position of metallic objects.
Applications
The main application area of the BIP is linear position monitoring
of drive spindles and clamping devices for tools and workpieces.
Inductive
position sensors
Applications
Summary
Magneto-
inductive posi-
tion sensors BIL
Inductive
position sensors
BIP
Basic
Information and
Definitions
Applications
These positioning systems BIP are ideal for integrated production
monitoring because their unmatched effective length ratio makes
installation possible in even the most confined applications.
www.balluff.com 263
Inductive Position Sensors Compact and absolute
Summary
Interfaces
0...10 V ■ ■ ■
Output
4...20 mA ■ ■ ■
IO-Link
Target/magnet
Magnet ■ ■ ■
Metal
■ ■ ■ ■ Inductive
position sensors
14 μm 40 μm 80 μm 80 μm Applications
Summary
±250 μm ±400 μm ±300 μm ±400 μm
Magneto-
inductive posi-
±80 μm ±100 μm ±80 μm ±80 μm tion sensors BIL
Inductive
position sensors
BIP
■ ■ ■ ■
Basic
Information and
■ ■ ■ ■ Definitions
■ ■
■ ■ ■ ■
www.balluff.com 265
Inductive
Position
Sensors
Magneto-inductive position sensors BIL
Magneto-inductive position sensors BIL are compact position sen-
sors for position detection up to 160 mm away.
The magneto-inductive analog position sensor measures without
contact and absolutely, using a wireless magnet.
266
Magneto-inductive Position Sensors BIL
Contents
SMARTSENS
www
www.balluff.com 267
Magneto-inductive
Position Sensors Micro BIL
Summary
BIL features
■ Wear-free since the position is detected without contact
■ Insensitive to shock and vibration
■ Absolute output signal: Voltage or current
(cable break monitoring possible)
■ Housing cross-section 15×15 mm
■ Simple installation
Sensing surface
Teach-in
Connect either the voltage or current output.
www.balluff.com 269
Magneto-inductive Position Sensors BIL
General data
Out-of-range function
Magnet within working range:
■ Output voltage 0...10 V or output current 4...20 mA
■ LED not on
■ Magnet outside the working range:
0 V Voltage 10 V
■ Output voltage approx. 11 V or output current approx. 22 mA
■ LED lights up
Distance "D"
of the magnet to
the sensor,
see page 272 Sensing surface
Index slot
Do not connect
Connect either the voltage
or current output.
Original mounting brackets and screws are recommended for Please order accessories separately. See page 272
attaching the BIL.
0 V Voltage 10 V 0V Voltage
4 mA Current 20 mA 4 mA Current 10 V
20 mA
Distance "D" Distance "D"
of the magnet to of the magnet
the sensor, to the sensor, Sensing surface
see page 272 Sensing surface see page 272
www.balluff.com 271
Magneto-inductive Position Sensors BIL
Accessories
Sensing
surface
74
S-S
ctor BK
nne 75
Co S-S
cto r BK
Co nne
Mounting examples
Inductive
position sensors
Magneto-
inductive posi-
tion sensors BIL
Summary
Micro-BIL
BIL
Accessories
Inductive
position sensors
BIP
Basic
Information and
Definitions
www.balluff.com 273
Inductive
Position
Sensors
Inductive Position Sensors BIP
Balluff magneto-inductive position sensors detect positions up to
103 mm away. Position sensors BIP measure without contact and
absolutely using a passive non-magnetic magnet. The compact
design means these sensors can be easily integrated into the ap-
plication even when mounting space is extremely tight. Even the
magnet can be designed as an integral part of an application. Analog
and digital interfaces ensure easy usability.
274
Inductive Position Sensors BIP
Contents
www.balluff.com 275
Inductive Position Sensors BIP Able to be
General data
integrated perfectly
-
2
-
2
www.balluff.com 277
Inductive Position Sensors BIP Optimized
General data
effective length
teachable teachable
92.5 21 121 21
Please order Metal Target separately.
90.5 M8×1 119 M8×1
Type designation: BAM TG-XE-001
Ordering code: BAM01CP 55.3 55.3
2
2
8
32.5
32.5
22
22
27
23 17 23 17
5
7 7
18 5
9 10
7.4
7.4
R3
R3
Inductive
position sensors
Magneto-
inductive posi-
tion sensors BIL
Inductive
position sensors
BIP
General data
Basic
Information and
Definitions
www.balluff.com 279
Inductive
Position
Sensors
280
Basic Information and Definitions
Contents
www.balluff.com 281
Basic Information and Definitions
Definitions
Position sensors Position sensors with analog output are sensors that generate a con-
with analog output tinually varying output signal that depends on the distance between its
sensing surface and the location of the magnet relative to the sensor.
Repeat accuracy R Repeat accuracy R is the value of output signal changes under
defined conditions, expressed as a percentage of the upper distance.
The measurement must be taken in the lower, upper and center
area of the linear range. It corresponds to the repeat accuracy R of
proximity switches and is determined under the same standardized
conditions (EN 60947-5-2).
Position sensors with analog output achieve the value R of ≤ 5%
defined in the standard.
Repeat accuracy RBWN Repeat accuracy RBWN describes the precision an analog sensor
achieves when moving to a measuring point multiple times. This value,
specified based on Balluff Factory Standard (BWN Pr. 44), describes
the maximum deviation from this measuring point.
Inductive
Output curves BIL AMD0... BIL EMD0.../ BIP ED2... BIL ED0.../ BIP AD.../ BIP CD... position sensors
Magneto-
inductive posi-
tion sensors BIL
Inductive
position sensors
BIP
Basic
Information and
Definitions
Definitions
Installation notices It is recommended that the BIL and magnet be installed or attached
to non-magnetizable materials, such as non-ferrous metals, austenitic
steels, plastics, etc. This applies to the installation of both the sensor
and the magnet.
Magnetic fields near the BIL can affect the output signal depending on
their location and strength. This also applies to magnets neighboring
BIL sensors.
Values in mm
An area free of metals should be maintained all the way around the
BIP's sensing surface in order to minimize the effects on the measur-
ing signal caused by the installation material (see notes in the user's
guide).
Invalid measurement signals may result if the sensor detects another
metal part aside from the magnet.
www.balluff.com 283
Photoelectric
Distance
Sensors
Photoelectric distance sensors are used when distances to objects
need to be measured or monitored or their precise position is to
determined. They support positioning tasks, material flow controls
and level detections in the most diverse of applications – also across
large distances.
■ www.balluff.com 285
Photoelectric Distance Sensors
Applications
Optical distance sensors are used when distances of objects need Applications
to be measured or monitored with precise position determination. ■ Control tasks
Distance measurement is based on the triangulation principle where ■ Sensing
light travel time is measured. ■ Object positioning
PSD-elements or CCD-arrays are used for the receiving elements, ■ Level detection
with the emitter consisting of a red light- or laser light source.
Analog current- and voltage values, serial interfaces and digital
outputs are available to the user.
15...30 V DC
18...30 V DC
Alarm output
1...10 mm
Laser light
4...20 mA
■ Ordering code
Red light
0...10 V
IO-Link
■ Part number
Cable
Distance sensor
BOD000H BOD 6K-RA01-S75-C 20...80 mm n.a. ■ ■ ■ ■ ■ 289
BOD000F BOD 6K-RA01-C-02 20...80 mm n.a. ■ ■ ■ ■ ■ 289
NPN on request
■ www.balluff.com 287
Photoelectric Distance Sensors
BOD 6K distance sensors
Features
■ Fixed measuring range between 20...80 mm
■ Analog output 0...10 V
■ Adjustable background suppression
■ PNP, NO/NC switching output
■ Teach-in
■ Button disable
■ Connector- or cable version 20 mm
80 mm
Analog
Output voltage
Analog
Working distance
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 6K BOD 6K
Working range 20...80 mm 20...80 mm
Measuring range 60 mm 60 mm
PNP Normally open/ Ordering code BOD000H BOD000F
normally closed Part number BOD 6K-RA01-S75-C BOD 6K-RA01-C-02
Supply voltage US 15...30 V DC 15...30 V DC
Analog output 0...10 V (max. 3 mA) 0...10 V (max. 3 mA)
No-load supply current I0 max. ≤ 30 mA at 24 V DC ≤ 30 mA at 24 V DC
Output current 100 mA 100 mA
Limit frequency 200 Hz 200 Hz
Switching type Light/dark (selectable) Light/dark (selectable)
Polarity reversal protected/short-circuit protected yes/yes yes/yes Photoelectric
distance sensors
Settings Teach-in Teach-in Applications
Emitter, light type LED, red light LED, red light Product
Wavelength 660 nm 660 nm overview
Light spot diameter 5×5 mm at 60 mm 5×5 mm at 60 mm BOD 6K
BOD 21M laser
Power-on indicator Green LED Green LED
BOD 26K-LA Laser
Output function indicator Yellow LED Yellow LED
BOD 26K-LB Laser
Response time 0.5 ms 0.5 ms
BOD 63M Laser
Switching frequency f 1 kHz 1 kHz BOD 66M-R
Degree of protection as per IEC 60529 IP 67 IP 67 BOD 66M-L Laser
Ambient temperature Ta –20...60 °C –20...60 °C
Permissible ambient light 5 klx 5 klx
Material Housing ABS ABS
Optical surface PMMA PMMA
Connection M12 connector, 4-pin 2 m PVC cable, 4×0.14 mm²
Connector orientation
4 4.2
24
32
24
32
8
42
17
9
9
5
10
4
3.8
2.6 2.6
10.7 M8x1 10.7
21 21
■ www.balluff.com 289
Photoelectric Distance Sensors
BOD 21M laser distance sensors
[
Series BOD 21M BOD 21M
Working range 25...45 mm 25...45 mm
Measuring range 20 mm 20 mm
2× PNP Normally open/ Ordering code BOD000L BOD000P
normally closed Part number BOD 21M-LA01-S92 BOD 21M-LB01-S92
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 1...10 V (max. 3 mA) 4...20 mA
Settings Teach-in (rotary switch) Teach-in (rotary switch)
Switching type Light/dark switching Light/dark switching
Emitter, light type Laser, pulsed red light Laser, pulsed red light
Wavelength 630 nm 630 nm
Laser class 2 2
Light spot diameter Ø1 mm at 45 mm Ø1 mm at 45 mm
Temperature drift ≤ 0.2%/°K ≤ 0.2%/°K
Resolution 30 μm 30 μm
Linearity ~0.5% ~0.5%
Recommended accessories:
(please order separately)
Emitter
1
2
Receiver
Description Ordering
code
1 Mounting bracket BAM00T9
2 Mounting bracket BAM00TA
0°
27
Suitable connector:
(please order separately) Green LED
Yellow LED
Connectors without LED are suitable for PNP and NPN sensors.
Emitter
Receiver
Receiver
0°
0°
27
27
s
s
te
te
ta
ta
Ro
Ro
■ www.balluff.com 291
Photoelectric Distance Sensors
BOD 26K-LA laser distance sensors
Features
■ Fixed measuring range between 45...85 mm
■ Analog output 0...10 V
■ 20 μm or 80 μm resolution
■ Connector- or cable version
[
Series
Working range
Measuring range
Ordering code
45 mm Part number
85 mm Supply voltage US
Analog output
No-load supply current I0 max.
Output current
Connection wiring diagrams Limit frequency
Polarity reversal protected/short-circuit protected
Settings
Emitter, light type
Wavelength
Shield
Laser class
Light spot diameter
Temperature drift
Resolution
Shield
Linearity
Power-on indicator
Contamination indicator
Analog output BOD 26K-LA0... Limit frequency
Rise time (from 10% to 90%)
U Fall-off time (from 90% to 10%)
Degree of protection as per IEC 60529
Ambient temperature Ta
10 V
Measuring range Permissible ambient light
Material Housing
Optical surface
Connection
Output voltage
Connector orientation
0V
45 mm 85 mm
Connectors without LED are suitable for PNP and NPN sensors.
You can find special accessories for photoelectric sensors, such as
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
Emitter Receiver
Rotates 270°
■ www.balluff.com 293
Photoelectric Distance Sensors
BOD 26K-LB laser distance sensors
Features
■ Adjustable measuring range between 30...100 mm
■ Analog output 4...20 mA adjustable: Rising or falling
■ Optional with RS485-interface (for master-slave-mode) and
for visualization using a computer (additional software required)
■ 2 switching outputs with adjustable switching points
■ Teach-in
■ Adjustable averaging
■ Numerous additional functions
30 mm
100 mm
20 mA
Output current
0 mA 0V
30 100 mm
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 26K BOD 26K
Working range 30...100 mm 30...100 mm
Measuring range adjustable max. 70 mm adjustable max. 70 mm
2× PNP Normally open/ Ordering code BOD0005 BOD000C
normally closed Part number BOD 26K-LB04-S115-C BOD 26K-LBR04-S115-C
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 4...20 mA 4...20 mA
No-load supply current I0 max. ≤ 40 mA ≤ 40 mA
Output current 100 mA 100 mA
Switching type Light/dark switching Light/dark switching
Interface RS485
Polarity reversal protected/short-circuit protected yes/yes yes/yes Photoelectric
distance sensors
Settings Teach-in Teach-in Applications
Additional function Master-slave mode Product
Emitter, light type Laser, red light Laser, red light overview
Wavelength 650 nm 650 nm BOD 6K
BOD 21M laser
Laser class 2 2
BOD 26K-LA laser
Light spot diameter 3.25 mm at 100 mm 3.25 mm at 100 mm
BOD 26K-LB laser
Resolution ≤ 70 μm ≤ 70 μm
BOD 63M laser
Linearity ≤ 175 μm ≤ 175 μm BOD 66M-R
Power-on indicator Green LED Green LED BOD 66M-L laser
Output function indicator Yellow LED Yellow LED
Switching frequency 1 kHz 1 kHz
Time function 50 ms pulse extension 50 ms pulse extension
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –10...+60 °C –10...+60 °C
Permissible ambient light EN 60947-5-2 EN 60947-5-2
Material Housing Impact-resistant ABS Impact-resistant ABS
Optical surface PMMA PMMA
Connection M12 connector, 8-pin M12 connector, 8-pin
Connector orientation
Emitter Receiver
Emitter Receiver
■ www.balluff.com 295
Photoelectric Distance Sensors
BOD 26K-LB laser distance sensors
Features
■ Adjustable measuring range between 80...300 mm
■ Analog output 4...20 mA
Adjustable: Rising or falling
■ Optional with RS485-interface (for master-slave-mode) and
for visualization using a computer (additional software required)
■ 2 switching outputs with adjustable switching points
■ Teach-in
■ Adjustable averaging
■ Numerous additional functions
80 mm
300 mm
20 mA
Output current
0 mA 0V
80 300 mm
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 26K BOD 26K
Working range 80...300 mm 80...300 mm
Measuring range adjustable max. 220 mm adjustable max. 220 mm
2× PNP Normally open/ Ordering code BOD0006 BOD000E
normally closed Part number BOD 26K-LB05-S115-C BOD 26K-LBR05-S115-C
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 4...20 mA 4...20 mA
No-load supply current I0 max. ≤ 40 mA ≤ 40 mA
Output current 100 mA 100 mA
Switching type Light/dark switching Light/dark switching
Interface RS485
Polarity reversal protected/short-circuit protected yes/yes yes/yes Photoelectric
distance sensors
Settings Teach-in Teach-in Applications
Additional function Master-slave mode Product
Emitter, light type Laser, red light Laser, red light overview
Wavelength 650 nm 650 nm BOD 6K
BOD 21M laser
Laser class 2 2
BOD 26K-LA laser
Light spot diameter 4.5 mm at 300 mm 4.5 mm at 300 mm
BOD 26K-LB laser
Resolution ≤ 220 μm ≤ 220 μm
BOD 63M laser
Linearity ≤ 550 μm ≤ 550 μm BOD 66M-R
Power-on indicator Green LED Green LED BOD 66M-L laser
Output function indicator Yellow LED Yellow LED
Switching frequency 1 kHz 1 kHz
Time function 50 ms pulse extension 50 ms pulse extension
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –10...+60 °C –10...+60 °C
Permissible ambient light EN 60947-5-2 EN 60947-5-2
Material Housing Impact-resistant ABS Impact-resistant ABS
Optical surface PMMA PMMA
Connection M12 connector, 8-pin M12 connector, 8-pin
Connector orientation
Emitter Receiver
Emitter Receiver
■ www.balluff.com 297
Photoelectric Distance Sensors
BOD 26K-LB laser distance sensors
Features
■ Adjustable measuring range
■ Analog output 4...20 mA
Adjustable: Rising or falling
■ 1 switching output with adjustable switching points
■ Teach-in
■ Laser beam can be turned off
30 mm
100 mm
Connector diagram
80 mm
300 mm
20 mA 20 mA
Output current
Output current
4 mA 4 mA
0 mA 0 mA
30 100 mm 80 300 mm
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 26K BOD 26K
Working range 30...100 mm 80...300 mm
Measuring range adjustable max. 70 mm adjustable max. 220 mm
PNP NO/NC Ordering code BOD0007 BOD0008
Part number BOD 26K-LB06-S92-C BOD 26K-LB07-S92-C
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 4...20 mA 4...20 mA
No-load supply current I0 max. ≤ 40 mA ≤ 40 mA
Output current 100 mA 100 mA
Switching type Light/dark switching Light/dark switching
Polarity reversal protected/short-circuit protected yes/yes yes/yes
Settings Teach-in Teach-in Photoelectric
distance sensors
Emitter, light type Laser, red light Laser, red light Applications
Wavelength 650 nm 650 nm Product
Laser class 2 2 overview
Light spot diameter 3.25 mm at 100 mm 4.5 mm at 300 mm BOD 6K
BOD 21M laser
Resolution ≤ 70 μm ≤ 220 μm
BOD 26K-LA laser
Linearity ≤ 175 μm ≤ 550 μm
BOD 26K-LB laser
Power-on indicator Green LED Green LED
BOD 63M laser
Output function indicator Yellow LED Yellow LED BOD 66M-R
Switching frequency 1 kHz 1 kHz BOD 66M-L laser
Time function 50 ms pulse extension 50 ms pulse extension
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –10...+60 °C –10...+60 °C
Permissible ambient light EN 60947-5-2 EN 60947-5-2
Material Housing Impact-resistant ABS Impact-resistant ABS
Optical surface PMMA PMMA
Connection M12 connector, 5-pin M12 connector, 8-pin
Connector orientation
Emitter Receiver
Emitter Receiver
■ www.balluff.com 299
Laser class
The transmitter corresponds to a class 2
Photoelectric Distance Sensors laser according to EN 60825-1:2001-11.
Thus no additional protective measures are
BOD 63M laser distance sensors required for operation.
Install the device so that the laser warning
label is easily visible.
[
traditional methods meet either technological or economical limits.
Such applications include detecting small objects at large distances
and operating in difficult conditions, such as if sensing must be per-
formed "outside" of processes with high temperatures or in robotic Series
cells. Working range
Measuring range
Features 2× PNP Normally Ordering code
■ Small laser spot for detecting small objects over large distances open Part number
■ Virtually independent of the reflective properties of the target Supply voltage US
object within a specific scanning range Analog output
■ Background suppression across the entire working range No-load supply current I0 max.
■ Analog-, switching- and alarm output Switching type
■ Laser beam can be turned off Polarity reversal protected/short-circuit protected
Settings
Applications Emitter, light type
■ Exact detection tasks over long distances (e.g. due to design Wavelength
limitations or heat at the target location) Laser class
■ Detecting objects with changing colors, shiny surfaces or Light spot diameter
unfavorable angles to the light beam
■ Flexible solutions for position detection, level measurement and Resolution
-monitoring, distance- and height measurement, quality assurance Gray value shift
applications Repeat accuracy per BWN
Temperature drift
Linearity
Switching hysteresis
Power-on indicator
Switching output
Stability indicator
Ready delay
Response time
Recommended Switching frequency
accessories: Degree of protection as per IEC 60529
(please order separately) Ambient temperature Ta
Permissible ambient light
Description Ordering
Material Housing
code
Optical surface
Mounting bracket BAM00P6
Connection
COM 2
38.4 kbaud
00C8 H...1770 H
Stability indicator
Switching points, laser on/off, button disable
Receiver
5
5.
Emitter
M
4×
Rotates 270°
■ www.balluff.com 301
Photoelectric Distance Sensors
BOD 63M laser distance sensors
Analog output
Scanning range
Scanning range
Switching output
Hysteresis
Switching
distance
White
Gray
Gray
Black
Black
[
Series BOD 63M BOD 63M
Working range 200...6000 mm 200...6000 mm
Measuring range 5800 mm 5800 mm
2× PNP Normally Ordering code BOD000W BOD0011
open Part number BOD 63M-LA04-S115 BOD 63M-LB04-S115
Supply voltage US 15...30 V DC 15...30 V DC
Analog output 0...10 V 4...20 mA
No-load supply current I0 max. ≤ 75 mA ≤ 75 mA
Output current Switching output 200 mA 200 mA
Error output 200 mA 200 mA
Switching type Light switching Light switching
Polarity reversal protected/short-circuit protected yes/yes yes/yes Photo
electric distance
Settings Potentiometer, 4 revolutions Potentiometer, 4 revolutions sensors
Emitter, light type Laser, red light Laser, red light Applications
Wavelength 660 nm 660 nm Product
overview
Laser class 2 per EN 60825 2 per EN 60825
BOD 6K
Light spot diameter 10 mm 10 mm BOD 21M laser
Resolution ≤ 1 mm ≤ 1 mm BOD 26K-LA laser
Gray value shift ≤ 1.5% ≤ 1.5% BOD 26K-LB laser
Repeat accuracy per BWN ≤ ±4 mm ≤ ±4 mm BOD 63M laser
Temperature drift ≤ 1.5 mm/°C ≤ 1.5 mm/°C BOD 66M-R
Linearity ≤ ±1% ≤ ±1% BOD 66M-L laser
Switching hysteresis ≤ 15 mm ≤ 15 mm
Power-on indicator Green LED Green LED
Switching output 2× yellow LED 2× yellow LED
Stability indicator Red LED Red LED
Ready delay ≤ 20 ms ≤ 20 ms
Response time ≤ 2 ms ≤ 2 ms
Switching frequency ≥ 250 Hz ≥ 250 Hz
Degree of protection as per IEC 60529 IP 67 IP 67
Ambient temperature Ta –10...+60 °C –10...+60 °C
Permissible ambient light ≤ 10 klx ≤ 10 klx
Material Housing Anodized aluminum Anodized aluminum
Optical surface Glass Glass
Connection M12 connector, 8-pin M12 connector, 8-pin
Connector orientation
Receiver
5
5.
Emitter
M
4×
■ www.balluff.com 303
Photoelectric Distance Sensors
BOD 66M-R distance sensors
Distance measurements with high resolution are achieved using Analog output BOD 66M-R...
triangulation and modern CCD-technology.
Measuring range
The BOD 66M-R_01 with analog voltage- or current output and an
additional switching output can measure or monitor distance and, at
the same time, operate as a light scanner with background suppres-
sion for object detection.
The BOD 66M-R_01 uses red light over a measuring range of
Output voltage
100...600 mm at a resolution of 0.5 mm.
Features
■ Extremely color- and ambient light insensitive
■ Working range 100...600 mm
■ Resolution 0.5 mm
■ Analog output with voltage (1...10 V) or current (4...20 mA)
■ PNP-switching output teachable
Working distance
■ Rugged metal housing
■ Scratch-resistant glass optics
Teach-in
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 66M BOD 66M
Working range 100...600 mm 100...600 mm
Measuring range 500 mm 500 mm
PNP Normally Ordering code BOD0015 BOD0016
open Part number BOD 66M-RA01-S92-C BOD 66M-RB01-S92-C
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 0...10 V 4...20 mA
No-load supply current I0 max. ≤ 150 mA ≤ 150 mA
Output current 250 mA 250 mA
Switching type Light switching Light switching
Polarity reversal protected/short-circuit protected yes/yes yes/yes
Settings Teach-in Teach-in Photo
electric distance
Emitter, light type LED, red light LED, red light sensors
Wavelength 660 nm 660 nm Applications
Light spot diameter approx. 10 mm approx. 10 mm Product
overview
Resolution ≤ 0.5 mm ≤ 0.5 mm
BOD 6K
Gray value shift (90%/6%) ≤ 1% ≤ 1% BOD 21M laser
Repeat accuracy per BWN ±0.5% ±0.5% BOD 26K-LA laser
Temperature drift 0.2 mm/°C 0.2 mm/°C BOD 26K-LB laser
Absolute measuring accuracy** ±2% (at the measuring distance) ±2% (at the measuring distance) BOD 63M laser
Power-on indicator Green LED Green LED BOD 66M-R
Output function indicator Yellow LED Yellow LED BOD 66M-L laser
On/off delay ≤ 100 ms ≤ 100 ms
Ready delay ≤ 300 ms ≤ 300 ms
Switching frequency 20...100 Hz* 20...100 Hz*
Degree of protection as per IEC 60529 IP 65 IP 65
Ambient temperature Ta –20...+50 °C –20...+50 °C
Permissible ambient light ≤ 5 klx ≤ 5 klx
Material Housing Anodized aluminum Anodized aluminum
Optical surface Glass Glass
Connection M12 connector, 8-pin M12 connector, 8-pin
Connector orientation
■ www.balluff.com 305
Photoelectric Distance Sensors
BOD 66M-L laser distance sensors
The BOD 66M-L_04 features an analog output along with an ad- Laser class
ditional switching output. The transmitter corresponds to a class 2 laser according to
It measures the object position across a range from 200...2000 mm. EN 60825-1:2001-11. Thus no additional protective measures are
In addition, it allows the switching output (background suppression) required for operation.
to be configured in the same area using teach-in. Forward-looking Install the device so that the laser
laser- and CCD-technology ensure accuracy and reliability. warning label is easily visible.
Features
■ Laser class 2
■ Small light spot over the entire range
■ Extremely color- and ambient light insensitive due to
CCD- line receiver
■ Analog current- or voltage output over 200...2000 mm
■ PNP-switching output, teachable
■ Rugged metal housing
■ Scratch-resistant glass optics
Applications
■ Background suppression up to 2 m
■ Analog measuring at up to 2 m target distance
■ Positioning tasks
Connector diagram
Output voltage
Teach-in
Working distance
You can find special accessories for photoelectric sensors, such as Connectors without LED are suitable for PNP and NPN sensors.
reflectors, apertures, lenses, filters and deflection heads,, in
our Object Detection catalog.
You can find more mechanical accessories including mounting compo- You can find more electrical accessories including a large selection of
nents of all types, such as clamping holders, mounting brackets or the Balluff plug connectors and connecting cables in a wide variety materials, colors and
mounting system, BMS, in our Accessory Product Line catalog. lengths in our Industrial Networking and Connectivity catalog.
[
Series BOD 66M BOD 66M
Working range 200...2000 mm 200...2000 mm
Measuring range 1800 mm 1800 mm
PNP Normally Ordering code BOD0013 BOD0014
open Part number BOD 66M-LA04-S92-C BOD 66M-LB04-S92-C
Supply voltage US 18...30 V DC 18...30 V DC
Analog output 1...10 mm 4...20 mA
No-load supply current I0 max. ≤ 150 mA ≤ 150 mA
Output current 250 mA 250 mA
Switching type Light switching Light switching
Polarity reversal protected/short-circuit protected yes/yes yes/yes
Settings Teach-in Teach-in Photo
electric distance
Emitter, light type Laser, red light Laser, red light sensors
Wavelength 660 nm 660 nm Applications
Laser class 2 2 Product
overview
Light spot diameter 3× 12 mm² at 2 m 3× 12 mm² at 2 m
BOD 6K
Resolution ≤ 5 mm ≤ 5 mm BOD 21M laser
Gray value shift (90%/6%) ≤ 1% ≤ 1% BOD 26K-LA laser
Repeat accuracy ±0.5% ±0.5% BOD 26K-LB laser
Temperature drift 0.6 mm/°C 0.6 mm/°C BOD 63M laser
Absolute measuring accuracy** ±2% (at the measuring distance) ±2% (at the measuring distance) BOD 66M-R
Power-on indicator Green LED Green LED BOD 66M-L laser
Output function indicator Yellow LED Yellow LED
On/off delay ≤ 100 ms ≤ 100 ms
Ready delay ≤ 300 ms ≤ 300 ms
Switching frequency 10...100 Hz* 10...100 Hz*
Degree of protection as per IEC 60529 IP 65 IP 65
Ambient temperature Ta –20...+50 °C –20...+50 °C
Permissible ambient light ≤ 5 klx ≤ 5 klx
Material Housing Anodized aluminum Anodized aluminum
Optical surface Glass Glass
Connection M12 connector, 5-pin M12 connector, 5-pin
deep
Emitter deep
Receiver
■ www.balluff.com 307
Inductive
Distance
Sensors
Balluff inductive distance sensors BAW provide an absolute voltage-
or current signal that changes proportionally to the distance of a
metallic target. Objects of varying shape and size made of ferrous
or non-ferrous materials damp the sensor to different degrees. This
provides a simple way of detecting positions, distances and material
differences.
■ www.balluff.com 309
Inductive Distance Sensors
Features, output curve, evaluating programmed switching points
Features
■ Distance-proportional analog output signal
■ Contactless, absolute measuring principle
■ Wide variety of designs: cylindrical and cubical
■ Measuring ranges from 0.5 to 50 mm
■ High repeat accuracy
■ Optimal linearity
■ Low temperature drift
■ Measuring speed up to 40 m/s
■ LED for restricting the working range
■ Insensitive to contamination
Wear
Brake disk
Working-
range
Critical
Area
Distance changes in the sensor axis Eccentrics, cams or unbalanced mo- Detecting longer distances by sens-
result in output signals proportional tion result in a periodic change in the ing an inclined plane.
to distance. output signal.
If the distance is kept constant, the Distances can be precisely measured The seal ring effectively reduces the
output signal only changes if the even at high travel speeds. distance between the nut/screw and
object material is different. the sensor, thereby changing the
output signal.
Tie rod
In injection molding machines, the clamping force of the tool is built up through
a toggle joint and a hydraulic cylinder. The extension of the machine tie rods is
thereby directly proportional to the clamping force, and can be easily deter-
mined using an inductive distance sensor.
■ www.balluff.com 311
Inductive Distance Sensors
Cylinder designs, Ø 6.5 mm, M8×1
Temperature output
Series Ø 6.5 mm Ø 6.5 mm M8×1
Installation type (observe instructions in Basic Information chapter) Flush Flush Flush
Output signal Voltage, 0...10 V Voltage, 0...10 V Voltage, 0...10 V
Linear range sl 0.5...2 mm 0.5...2 mm 0.5...1.5 mm
Ordering code BAW000L BAW000J BAW000N
Part number BAW G06EF-UAC20B-S49G BAW G06EE-UAF20B-EP03-K BAW M08EI-UAD15B-BP00.2-GS04
Supply voltage US 15...30 V DC 21.6...26.4 V DC 15...30 V DC
Rated insulation voltage Ui (protection class) 75 V DC 75 V DC 250 V AC ([)
Effective distance se 1.25 mm 1.25 mm 1 mm
Load resistance RL min. 2 kΩ 5 kΩ 2 kΩ
Load resistance RL max.
Polarity reversal protected/transposition protected/short-circuit protected yes/yes/yes no/no/no yes/yes/yes
Adjustment display (LED) yes no no
Ambient temperature range Ta +10...+60°C* +10...+60°C* –10...+70 °C
Repeat accuracy RBWN ±40.0 μm ±10.0 μm ±8.0 μm
Non-linearity max. ±45 μm ±45 μm ±30 μm
Limit frequency (–3 dB) 1 kHz 1 kHz 1 kHz
Response time 0.5 ms 1 ms 0.5 ms
Temperature coefficient, typ. in range from +10...+50 °C -0.6 μm/K –1 μm/K –1 μm/K
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67
Approvals CE, cULus CE CE, cULus
Material Housing Stainless steel Stainless steel Stainless steel
Sensing surface PBT PBT PBT
Connection M8 connector, 3 m PUR cable, M12 connector,
3-pin 4×0.14 mm² 3-pin with
0.2 m PUR cable
Temperature output
Typical
M8x1
43.5
13
58
M12x1
■ www.balluff.com 313
Inductive Distance Sensors
Cylinder designs, M12×1
Temperature output
M12×1 M12×1 M12×1 M12×1 M12×1
Flush Flush Flush Flush Quasi-flush
Voltage, 0...10 V Voltage, 0...10 V Current, 0...20 mA Current, 0...20 mA Voltage, 0...10 V
0.5...2 mm 0.5...2 mm 0.5...2 mm 0.5...2 mm 1...5 mm
BAW0010 BAW001L BAW0019 BAW001C BAW0011
BAW M12ME-UAC20B-S04G BAW M12MG2-UAC20B-BP03 BAW M12MG2-IAC20B-BP00.2-GS04 BAW M12MG2-IAC20B-BP03 BAW M12ME-UAD50B-BP01
15...30 V DC 15...30 V DC 10...30 V DC 10...30 V DC 15...30 V DC
250 V AC ([) 250 V AC ([) 250 V AC ([) 250 V AC ([) 75 V DC
1.25 mm 1.25 mm 1.25 mm 1.25 mm 3 mm
2 kΩ 2 kΩ 2 kΩ
500 Ω 500 Ω
yes/yes/yes yes/yes/yes yes/yes/yes yes/yes/yes yes/yes/yes
yes yes yes yes no
–10...+70 °C –10...+70 °C –10...+70 °C –10...+70 °C 0...+60 °C
±20.0 μm ±8.0 μm ±5.0 μm ±5.0 μm ±10.0 μm
±45 μm ±45 μm ±45 μm ±45 μm ±160 μm
500 Hz 500 Hz 500 Hz 500 Hz 1 kHz Inductive
distance sensors
0.5 ms 0.5 ms 0.5 ms 0.5 ms 2 ms Features, output
0 μm/K –1 μm/K –1 μm/K –1 μm/K –1.5 μm/K curve, evaluating
programmed
IP 67 IP 67 IP 67 IP 67 IP 67 switching points
CE, cULus CE, cULus CE, cULus CE, cULus CE, cULus Applications
Brass, coated Brass, coated Brass, coated Brass, coated Brass, coated Tubular designs
PBT PBT PBT PBT PA 12 Block designs
M12 connector, 3 m PUR cable, M12 connector, 3 m PUR cable, 1 m PUR cable,
3-pin 3×0.34 mm² 3-pin with 3×0.34 mm² 4×0.25 mm²
0.2 m PUR cable
M12x1
26
17
30
Temperature output
Typical
■ www.balluff.com 315
Inductive Distance Sensors
Cylinder designs, M12×1
Temperature output
M12×1 M18×1 M18×1 M18×1 M18×1
Not flush Flush Flush Flush Flush
Current, 4...20 mA Voltage, 0...10 V Voltage, 0...10 V Voltage, 0...10 V Voltage, 0...10 V
1...4 mm 1...5 mm 1...5 mm 1...5 mm 1...5 mm
BAW003N BAW001Z BAW002K BAW0026 BAW0025
BAW M12MH1-ICC40F-S04G BAW M18ME-UAC50B-BP00.2-GS04 BAW M18MI-UAC50B-S04G BAW M18ME-UAE50B-S04G-K BAW M18ME-UAC50B-S04G
10...30 V DC 15...30 V DC 15...30 V DC 21.6...26.4 V DC 15...30 V DC
250 V AC ([) 75 V DC 250 V AC ([) 75 V DC 75 V DC
2.5 mm 3 mm 3 mm 3 mm
2 kΩ 2 kΩ 2 kΩ 2 kΩ
500 ohms
yes/yes/yes yes/yes/yes yes/yes/yes yes/yes/yes yes/yes/yes
yes yes yes yes yes
–10...+70 °C –10...+70 °C –10...+70 °C –10...+70 °C –10...+70 °C
±8.0 μm ±8.0 μm ±8.0 μm ±8.0 μm
±120 μm ±120 μm ±120 μm ±120 μm ±120 μm
500 Hz 500 Hz 500 Hz 500 Hz 500 Hz Inductive
distance sensors
0.5 ms 1 ms 1 ms 1 ms 1 ms Features, output
–1 μm/K –2 μm/K –1 μm/K –2 μm/K curve, evaluating
programmed
IP 67 IP 67 IP 67 IP 67 IP 67 switching points
CE, cULus CE, cULus CE, cULus CE, cULus CE, cULus Applications
Brass, coated Brass, coated Brass, coated Brass, coated Brass, coated Tubular designs
PBT PBT PBT PBT PBT Block designs
M12 connector, M12 connector, M12 connector, M12 connector, M12 connector,
3-pin 3-pin with 3-pin 4-pin 3-pin
0.2 m PUR cable
M12x1 M18x1
5
30
36
24
49.5
17
65
LED
LED
41.5
24
Temperature output
M12x1 Typical
Ø14.5
■ www.balluff.com 317
Inductive Distance Sensors
Cylinder designs, M18×1
With teach-in,
3 switching points With Teach-in
Series M18×1 M18×1 M18×1
Installation type (observe instructions in Basic Information chapter) Flush Flush Flush
Output signal Voltage, 0...10 V Voltage, 0...10 V Voltage, 0...10 V
Linear range sl 1...5 mm 1...5 mm 1...5 mm
Ordering code BAW002M BAW002U BAW0022
Part number BAW M18MI2-UAC50B-BP05-002 BAW M18MM-UAZ50B-BP05-505 BAW M18ME-UAC50B-BP03
Supply voltage US 15...30 V DC 21.6...26.4 V DC 15...30 V DC
Rated insulation voltage Ui (protection class) 250 V AC ([) 250 V AC ([) 75 V DC
Effective distance se 3 mm 3 mm 3 mm
Load resistance RL min. 2 kΩ 2 kΩ 2 kΩ
Load resistance RL max.
Polarity reversal protected/transposition protected/short-circuit protected yes/no/yes yes/no/yes yes/yes/yes
Adjustment display (LED) yes no yes
Ambient temperature range Ta –10...+70 °C –10...+70 °C –10...+70 °C
Repeat accuracy RBWN ±8.0 μm ±8.0 μm ±8.0 μm
Non-linearity max. ±120 μm ±120 μm ±120 μm
Limit frequency (–3 dB) 500 Hz 500 Hz 500 Hz
Response time 1 ms 1 ms 1 ms
Temperature coefficient, typ. in range from +10...+50 °C –1.5 μm/K 0 μm/K –1 μm/K
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67
Approvals CE, cULus CE, cULus CE, cULus
Material Housing Brass, coated Brass, coated Brass, coated
Sensing surface PBT PBT PBT
Connection 5 m PUR cable, 5 m PUR cable, 5 m PUR cable,
7×0.25 mm² 7×0.25 mm² 3×0.34 mm²
■ www.balluff.com 319
Inductive Distance Sensors
Cylinder designs, M18×1, M30×1.5
Temperature output
Series M18×1 M18×1 M30×1.5
Installation type (observe instructions in Basic Information chapter) Not flush Not flush Flush
Output signal Voltage, 0...10 V Voltage, 0...10 V Voltage, 0...10 V
Linear range sl 2...8 mm 4...16 mm 2...10 mm
Ordering code BAW002C BAW0029 BAW002W
Part number BAW M18MG-UAC80F-S04G BAW M18MG-UAC16F-S04G-K BAW M30ME-UAC10B-S04G
Supply voltage US 15...30 V DC 15...30 V DC 15...30 V DC
Rated insulation voltage Ui (protection class) 250 V AC ([) 250 V AC ([) 250 V AC ([)
Effective distance se 5 mm 10 mm 6 mm
Load resistance RL min. 2 kΩ 2 kΩ 2 kΩ
Polarity reversal protected/transposition protected/short-circuit protected yes/yes/yes yes/yes/yes yes/yes/yes
Adjustment display (LED) yes yes yes
Ambient temperature range Ta –10...+70 °C +10...+60°C* –10...+70 °C
Repeat accuracy RBWN ±12.0 μm ±200.0 μm ±10.0 μm
Non-linearity max. ±180 μm ±360 μm ±240 μm
Limit frequency (–3 dB) 500 Hz 500 Hz 500 Hz
Response time 1.5 ms 3 ms 1.5 ms
Temperature coefficient, typ. in range from +10...+50 °C –3 μm/K 8 μm/K 1.5 μm/K
Degree of protection as per IEC 60529 IP 67 IP 67 IP 67 per BWN Pr. 14
Approvals CE, cULus CE, cULus CE, cULus
Material Housing Brass, coated Brass, coated Brass, coated
Sensing surface PBT PBT PBT
Connection M12 connector, M12 connector, M12 connector,
3-pin 3-pin 3-pin
36
M12x1
Temperature output
Typical
M30×1.5 PG36
Not flush Flush
Voltage, 0...10 V Voltage, 0...10 V
3...15 mm 0...20 mm
BAW002Y BAW003M
BAW M30ME-UAC15F-S04G BAW MKZ-471.19-S4
15...30 V DC 20...30 V DC
250 V AC ([) 75 V DC
9 mm 10 mm
2 kΩ 10 kΩ
yes/yes/yes yes/yes/yes
yes yes
–10...+70 °C –10...+70 °C
±12.0 μm ±5.0 μm
±360 μm ±600 μm
350 Hz 20 Hz
3 ms Inductive
distance sensors
1.5 μm/K –1 μm/K Features, output
IP 67 IP 67 curve, evaluating
programmed
CE, cULus CE switching points
Brass, coated Brass, coated Applications
PBT PBT Tubular designs
M12 connector, M12 connector, Block designs
3-pin 3-pin
M12x1
■ www.balluff.com 321
Inductive Distance Sensors
Cylinder design, high-pressure resistant M12×1
Application areas
■ Control of valves
■ Parked position of cranes Series M12×1
■ Final position of installation Installation type (observe instructions in Basic Information chapter) Flush
supports Output signal Voltage, 0...10 V
■ Service measurements of valves Linear range sl 0.5...2 mm
■ Position monitoring in mobile Ordering code BAW0040
hydraulic systems Part number BAW Z08EO-UAD20B-S04G-H11
■ Control of agricultural technol- Supply voltage US 15...30 V DC
ogy Rated insulation voltage Ui (protection class) 75 V DC
Effective distance se 1.25 mm
Load resistance RL min. 2 kΩ
Polarity reversal protected/transposition protected/short-circuit protected yes/yes/yes
Adjustment display (LED) no
Ambient temperature range Ta –25...+85 °C
Repeat accuracy RBWN ±8.0 μm
Non-linearity max. ±45 μm
Limit frequency (–3 dB) 1 kHz
Response time 1 ms
Temperature coefficient, typ. in range from +10...+50 °C –1 μm/K
Degree of protection as per IEC 60529 IP 68
Approvals CE, cULus
Material Housing Stainless steel
Sensing surface Ceramic
Connection M12 connector,
3-pin
-
Connection wiring diagram
Connector, voltage output
500 bar
■ www.balluff.com 323
Inductive Distance Sensors
Block designs, 10×30×6 mm, 20×30×8 mm
45677_00
14 14 14
13
13
13
38.5
38.5
38.5
30.5
30.5
30.5
18.5
18.5
4
4
4 4
1.5
1.5
4
30 30 30
22 22 22
4.8 4.8 4.8
20°
20°
2
2
13.5
13.5
17
17
8.5
8.5
r
Typical Typical
49
M12x1
The temperature output (not short- The temperature output (not short-
circuit protected) provides a signal circuit protected) provides a signal
representing a precisely measured representing a precisely measured
temperature change. temperature change.
■ www.balluff.com 325
Inductive Distance Sensors
Block designs, 80×80×40 mm
Compact analog- ring sensor with 20 mm opening. Various metallic Testing cone for determining insertion depth
objects or insertion depths result in measured value changes. (measuring range and linearization)
Ø4
Installation conditions
Hole
> Ø 35 mm
Minimum distance 50 mm
No mutual interference for front- No mutual interference for parallel There should be at least 50 mm The opening should be at least at
mounting of two sensors. mounting of two sensors. of spacing when stacking multiple least Ø 35 mm for flat installation on
sensors. metal surfaces.
■ www.balluff.com 327
Power
Supplies
328
Power Supplies
Contents
Power supplies
Standard units 330
Intelligent power supplies 332
www.balluff.com
■ www.balluff.com 329
Power Supplies
Reliable power for demanding industrial
automation applications
Every industrial automation system needs a reliable, clean and con- ■ Ultra-reliable power supplies
trolled source of power without spikes. for protecting sensitive control electronics
Only then can these systems deliver the expected performance. The
new Balluff power supplies exceed expectation because they ensure ■ Protection against unforeseen events
reliable power even under demanding conditions. They fall in line integrated overload and overvoltage protection
with the long Balluff tradition of reliable and high-quality performance
products for industrial automation. But that's not all. Balluff power ■ Wide selection of models
supplies are one of many products from a comprehensive, profes- whether stand-alone or an individual combination of various
sional system. From a single source: from standardized inductive models,
and photoelectric sensors and connectivity products to industrial these solutions are perfect for your requirements
RFID and industrial network solutions including our new product line
of I/O modules for Profibus, DeviceNet and EtherNet/IP networks. ■ Clean, precision power supply for particularly
complex systems
Load regulation +/– 1% for all models, ripple & noise for most
models less than 50 mV
Ready output
Notifies the control system
that the power supply is ready
(included with most models)
Parallel/Single mode
If more power is required,
multiple units can be com-
bined in parallel (most models)
Rugged
DIN rail
mounting
Adjustable output
The output voltage can be
adjusted to compensate
for losses from cabling and
distributed components
CE, UL/cUL,
and TÜV
Approvals
Status indicator
LED for DC ON and DC LO
indicator (most models)
IP 20 metal housing
(most models)
Terminals with
contact protection
No additional protection
necessary
Housing material
Ordering code
0.75 mA/18 W
3.8 A/91.20 W
Parallel mode
Ready output
Input voltage
1.25 A/30 W
Part number
10 A/240 W
20 A/480 W
40 A/960 W
2.5 A/60 W
5 A/120 W
Power supply
Standard units
Power for controllers and networks
Intelligent
Specially designed for control devices, Balluff power supply units are power supplies
easily integrated into your control package and offer extra security.
Trouble-free installation
Reliable power has never been so simple to install. Starting with the
convenient mounting of DIN rails using the integrated Balluff high-
performance mounting system. The screw terminals are aligned to
enable the integration of an AC input from below and a DC output
from above. Connections with contact protection render additional
safety equipment superfluous.
■ www.balluff.com 331
Power Supplies
Intelligent devices for demanding industrial
automation applications
IP 67
Load level indicates the current Stress level indicates the Lifetime indicates the remaining All indicators are multi-
load on the device. The display physical and thermal loads. useful life of the device and is colored – in green, yellow or
indicates the load without any Changing the load has an effect based on the combination of all red – and show the status
delay. on device wear. loads. of the device.
■ www.balluff.com 333
334
Customized Services
According to your specifications. In the best quality.
Appropriate solution
www.balluff.com 335
Worldwide Sales
www.balluff.com 337
Linear Position Sensing
Alphanumeric index
Part number Ordering code Page Part number Ordering code Page
BAE PS-XA-1W-24-038-601 BAE00EN 333 BAW M18MI-IAC50B-S04G BAW002H 319
BAE PS-XA-1W-24-038-602 BAE00EP 333 BAW M18MI-ICC50B-S04G BAW002J 319
BAE PS-XA-1W-24-038-603 BAE00ER 333 BAW M18MI-UAC50B-S04G BAW002K 317
BAE PS-XA-1W-24-038-607 BAE00FW 333 BAW M18MM-UAZ50B-BP05-505 BAW002U 318
BAE PS-XA-1W-24-050-013 BAE00EK 333 BAW M30ME-UAC10B-S04G BAW002W 320
BAE PS-XA-1W-24-080-604 BAE00ET 333 BAW M30ME-UAC15F-S04G BAW002Y 321
BAE PS-XA-1W-24-080-605 BAE00FL 333 BAW MKK-050.19-S4 BAW003K 326
BAE PS-XA-1W-24-080-606 BAE00FY 333 BAW MKV-020.19-S4 BAW003L 327
BAE PS-XA-1W-24-100-014 BAE00EU 333 BAW MKZ-471.19-S4 BAW003M 321
BAE-PS-XA-1W-24-007-001 BAE0001 331 BAW R03KC-UAE40B-BP00,3-GS26 BAW0030 323
BAE-PS-XA-1W-24-012-002 BAE0004 331 BAW R03KC-UAE40B-BP00,3-GS49 BAW0031 323
BAE-PS-XA-1W-24-025-002 BAE0005 331 BAW R03KC-UAE40B-BP03 BAW0032 324
BAE-PS-XA-1W-24-038-003 BAE003J 331 BAW R06AC-UAF20B-EP03 BAW0033 325
BAE-PS-XA-1W-24-050-003 BAE0006 331 BAW R06AC-UAF20B-S49G BAW0034 324
BAE-PS-XA-1W-24-100-004 BAE0002 331 BAW Z01AC-BLD50B-DP03 BAW003A 325
BAE-PS-XA-1W-24-200-005 BAE0003 331 BAW Z01AC-UAD50B-DP03-K BAW003E 325
BAE-PS-XA-3Y-24-050-009 BAE0007 331 BAW Z05AC-BLD50B-BP00,75-GS04 BAW003W 325
BAE-PS-XA-3Y-24-100-006 BAE0008 331 BAW Z08EO-UAD20B-S04G-H11 BAW0040 322
BAE-PS-XA-3Y-24-200-007 BAE0009 331 BCC M415-0000-1B-031-PS72N1-020 BCC070Y 238
BAE-PS-XA-3Y-24-400-010 BAE003R 331 BCC M415-0000-1B-031-PS72N1-050 BCC070Z 238
BAM AD-TL-012-B/K-4 215 BCC M415-0000-1B-031-PS72N1-100 BCC0710 238
BAM AD-XA-007-M18×1.5/D12-2 BAM01JW 180 BCC M415-0000-2B-031-PS72N1-020 BCC0711 239
BAM AD-XA-007-M18×1.5/D12-4 BAM01JY 180 BCC M415-0000-2B-031-PS72N1-050 BCC0712 239
BAM MC-XA-006-D38,1-5 BAM01A5 228 BCC M415-0000-2B-031-PS72N1-100 BCC0713 239
BAM PT-XA-001-095-0-_ _ _ 180 BCC M415-M415-3B-329-PS72N1-006 BCC070M 238
BAM SE-XA-002-D38,1-S BAM01A4 228 BCC M415-M415-3B-329-PS72N1-010 BCC070N 238
BAM TG-XE-001 BAM01CP 278 BCC M415-M415-3B-329-PS72N1-020 BCC070P 238
BAM-AD-XA-003-D38,1-5 BAM01A3 228 BCC M415-M415-3B-329-PS72N1-050 BCC070R 238
BAW G06EE-UAF20B-EP03-K BAW000J 312 BCC M415-M415-3B-329-PS72N1-100 BCC070T 238
BAW G06EF-UAC20B-S49G BAW000L 312 BCC M415-M415-3B-329-PS72N1-150 BCC070U 238
BAW M08EF-UAC15B-S49G BAW000M 313 BCC M415-M415-3B-329-PS72N1-200 BCC070W 238
BAW M08EH-UAD15B-S04G BAW003R 313 BCC M41C-0000-1A-169-PS0C08-_ _ _C009 BCC09MY 24
BAW M08EI-UAD15B-BP00,2-GS04 BAW000N 312 BCC M475-0000-1B-000-01X575-000 BCC0715 237
BAW M08EI-UAD15B-BP03 BAW000T 313 BCC M475-0000-2B-000-01X575-000 BCC0714 237
BAW M08EI-UAD25F-BP03 BAW000W 313 BCC M478-0000-1A-000-43X834-000 BCC04MC 241
BAW M12MD-UAC40F-S04G BAW000Z 316 BCC M485-0000-1B-000-01X575-000 BCC0717 237
BAW M12ME-UAC20B-S04G BAW0010 315 BCC M485-0000-2B-000-01X575-000 BCC0716 237
BAW M12ME-UAD50B-BP01 BAW0011 315 BCC M488-0000-1A-000-43X834-000 BCC050F 241
BAW M12MF2-UAC40F-BP00,2-GS04 BAW0014 316 BCC_M418-M314-M415-V0038-000 BCC0CK4 241
BAW M12MF2-UAC40F-BP03 BAW0017 316 BCC-M415-0000-1A-014-PS0434 99, 111
BAW M12MG2-IAC20B-BP00,2-GS04 BAW0019 315 BCCM415-0000-2B-R01 BCC0718 239
BAW M12MG2-IAC20B-BP03 BAW001C 315 BCC-M425-0000-1A-014-PS0434 99, 111
BAW M12MG2-ICC20B-BP00,2-GS04 BAW001F 313 BDD 610-R3Q3-0-51-N-00 BAE004H 51
BAW M12MG2-ICC20B-BP03 BAW001H 314 BDD 610-R3Q3-0-53-N-00 BAE004J 51
BAW M12MG2-UAC20B-BP00,2-GS04 BAW001J 314 BDD 611-R3Q4-0-52-N-00 BAE004K 51
BAW M12MG2-UAC20B-BP03 BAW001L 315 BDD 622-R3Q4-0-52-N-00 BAE004M 51
BAW M12MH1-ICC40F-S04G BAW003N 317 BDD 632-R3Q4-0-52-N-00 BAE004P 51
BAW M12MI-UAC20B-S04G BAW001P 314 BDD-AM 10-1-P 249
BAW M18ME-ICC50B-BP03 BAW001T 319 BDD-AM 10-1-SSD BAE0069 25, 249
BAW M18ME-ICC50B-S04G BAW001U 319 BDD-CC 08-1-P 249
BAW M18ME-UAC50B-BP00,2-GS04 BAW001Z 317 BDD-CC 08-1-SSD BAE006F 25, 249
BAW M18ME-UAC50B-BP03 BAW0022 318 BDD-UM 3023 249
BAW M18ME-UAC50B-S04G BAW0025 317 BIL 000-MH-A BAM0176 272
BAW M18ME-UAE50B-S04G-K BAW0026 317 BIL 001-MH-A BAM0177 272
BAW M18MG-UAC16F-S04G-K BAW0029 320 BIL 01-HW-1 BAM00K4 272
BAW M18MG-UAC80F-S04G BAW002C 320 BIL 01-HW-2 BAM00K5 272
BAW M18MI2-UAC50B-BP05-002 BAW002M 318 BIL 01-HW-3 BAM00K6 272
BAW M18MI-BLC50B-S04G BAW002F 319 BIL AMD0-T060A-01-S75 BIL0001 270
Part number Ordering code Page Part number Ordering code Page
BIL ED0-B010P-02/30-S75 BIL0002 269 BML-M20-I40-A0-M072/054-R1 BML002P 39
BIL ED0-P160A-01-S75 BIL0004 271 BML-M21-I40-A0-M048/006-R0 BML002R 39, 45
BIL EMD0-T060A-01-S75 BIL0006 271 BML-M22-I40-A0-M031/016-R0 BML002T 39, 45
BIP AD0-B014-01-EP02 BIP0001 277 BML-M30-I30-A0-M122/090-R0 BML01EW 31
BIP AD2-B040-02-S4 BIP0002 277 BML-M31-I30-A0-M075/060-R0 BML01KM 31
BIP CD2-B014-01-EP02 BIP0008 277 BML-R01-M_ _ _ BAM04N4 53
BIP CD2-B040-02-S4 BIP0005 277 BML-S1C0-Q53_-M400-_0-KA_ _ 43
BIP ED2-B070-03-S75 BIP000C 278 BML-S1F_-A62Z-M3_ 0-90-_ _ _ _ 29
BIP ED2-B103-03-S75 BIP000E 278 BML-S1F_-Q61_-M3_ 0-_0-_ _ _ _ 29
BIP LD2-T014-01-EP02 BIP0007 277 BML-S1H_-_6_C-M3_A-D0-KA00,3-S284 23
BIP LD2-T040-02-S4 BIP0004 277 BML-S2B0-Q_ _ _-M4_ _-_0-_ _ _ _ 37
BIS Z-501-PU1-_ _/E 246 BML-S2E0-Q_ _ _-M4_ _-_0-_ _ _ _ 37
BIS Z-501-PU1-_ _/M 246 BML-Z0008 BAM01JL 53
BIS Z-502-PU1-_ _/E 246 BML-Z0010 BAM01L9 53
BIS Z-502-PU1-_ _/M 246 BNI-PBS-551-000-Z001 BNI001A 245
BIW1-A310-M_ _ _ _-P1-S115 133 BNI-PBS-552-000-Z001 BNI002H 245
BIW1-C310-M_ _ _ _-P1-S115 133 BOD 21M-LA01-S92 BOD000L 290
BIW1-E310-M_ _ _ _-P1-S115 133 BOD 21M-LA02-S92 BOD000M 291
BIW1-G310-M_ _ _ _-P1-S115 133 BOD 21M-LA04-S92 BOD000N 291
BIW-A-MF02-M 132 BOD 21M-LB01-S92 BOD000P 290
BKS 12-CS-00 BAM00K7 236 BOD 21M-LB02-S92 BOD000R 291
BKS 12-CS-01 BAM0114 236 BOD 21M-LB04-S92 BOD000T 291
BKS 16-CS-00 BAM0116 152, 154,156 BOD 26K-LA01-C-06 BOD0001 293
BKS-S 32M-_ _ 232 BOD 26K-LA01-S4-C BOD0002 293
BKS-S 32M-C-_ _ 233 BOD 26K-LA02-C-06 BOD0003 293
BKS-S 33M-_ _ 233 BOD 26K-LA02-S4-C BOD0004 293
BKS-S 48-15-CP-02 BCC 0069 239 BOD 26K-LB04-S115-C BOD0005 295
BKS-S 48-15-CP-05 BCC 006A 239 BOD 26K-LB05-S115-C BOD0006 297
BKS-S 48-15-CP-10 BCC 006C 239 BOD 26K-LB06-S92-C BOD0007 299
BKS-S 75-TB4-05-PU-00,05/02/02 236 BOD 26K-LB07-S92-C BOD0008 299
BKS-S 78M-00 233 BOD 26K-LBR04-S115-C BOD000C 295
BKS-S115/GS32-PU-00,2 240 BOD 26K-LBR05-S115-C BOD000E 297
BKS-S115-00 240 BOD 63M-LA02-S115 BOD000U 301
BKS-S115-PU-_ _ 240 BOD 63M-LA04-S115 BOD000W 303
BKS-S116-PU-_ _ 240 BOD 63M-LB02-S115 BOD0010 301
BKS-S137-19-PC-... 235 BOD 63M-LB04-S115 BOD0011 303
BKS-S151-19-PC-... 235 BOD 63M-LI06-S4 BOD0012 301
BKS-S232-PU-_ _ 233 BOD 6K-RA01-C-02 BOD000F 289
BKS-S233-PU-_ _ 233 BOD 6K-RA01-S75-C BOD000H 289
BKS-S48-15-CP-... 234 BTA-A1_-_ _ _ _ 242
BKS-S92-00 234 BTA-C1_-_ _ _ _ 243
BKS-S92-16/GS92-_ _ 235 BTA-E1_-_ _ _ _ 243
BKS-S92-TA1 235 BTA-G1_-_ _ _ _ 243
BKS-S93-00 234 BTL2-GS10-_ _ _ _-A BAM000P 52
BKS-S94-00 234 BTL2-GS10-_ _ _ _-A 101, 113
BKS-S94-R01 235 BTL2-S-3212-4Z 162
BKS-S95-00 234 BTL2-S-4414-4Z BAM0146 162
BMF 12M-NS-D-2-S4 BMF0021 43 BTL2-S-4414-4Z01-Ex BAM0148 211
BMF 12M-PS-D-2-S4 BMF0022 43 BTL2-S-4414-4Z01-Ex 213
BML-A013-T_ _ _ _ BML001K 53 BTL2-S-4414-4Z-Ex BAM0147 211
BML-C01 BAM01MF 53 BTL2-S-4414-4Z-Ex 213
BML-C02 BAM01MH 53 BTL2-S-5113-4K BAM0149 162
BML-M02-A33-A3-M0009-A BML039J 24 BTL2-S-5113-4K-Ex 211
BML-M02-A33-A3-M0028-C BML039K 24 BTL2-S-5113-4K-Ex BAM014A 213
BML-M20-I30-A0-M072/054-R0 BML002K 31 BTL2-S-6216-8P BAM014C 162
BML-M20-I40-A0-M031/021-R0 BML002L 40, 46 BTL2-S-6216-8P-Ex BAM014E 213
BML-M20-I40-A0-M048/037-R0 BML002M 40, 46 BTL5...B-DEXA-KA_ 205
BML-M20-I40-A0-M072/054-R0 BML002N 40, 46 BTL5...B-DEXB-KA_ _ 205
www.balluff.com 339
Linear Position Sensing
Alphanumeric index
Part number Ordering code Page Part number Ordering code Page
BTL5...J-DEXA-K_ _ 205 BTL6-P11_-M_ _ _ _-A1-S115 123
BTL5...J-DEXB-K_ _ 205 BTL6-P510-M_ _ _ _-_ _ _-_ _ _ _ _ 197
BTL5-_ _-M_ _ _ _-J-DEXC-TA12 207 BTL6-U110-M_ _ _ _ -PF-S4 109
BTL5-_1M_ _ _ _ -_-DEX_-_ _ _ _ 204 BTL6-V11E-M_ _ _ _-A1-S115 125
BTL5-A11-M_ _ _ _-P-_ _ _ _ 87 BTL6-V11E-M_ _ _ _-B-S115 159
BTL5-A11-M_ _ _ _-SF-_ _ _ 227 BTL6-V11V-M_ _ _ _-A1-S115 125
BTL5-A-CP01-K 235, 238 BTL6-V11V-M_ _ _ _-B-S115 159
BTL5-A-EH03 208 BTL7-A110-M_ _ _ _-_-_ _ _ _ 139
BTL5-C1_-M_ _ _ _-P-_ _ _ _ 87 BTL7-A501-M_ _ _ _-_-_ _ _ _ 141
BTL5-C1_-M_ _ _ _-SF-_ _ _ 227 BTL7-A501-M_ _ _ _-P-_ _ _ _ 81
BTL5-D1_ _-M_ _ _ _-P-S93 95 BTL7-A504-M_ _ _ _-_-_ _ _ _ 217
BTL5-E1_0-M_ _ _ _-_-_ _ _ _ 139 BTL7-A510-M_ _ _ _-_-_ _ _ _ 173
BTL5-E1_-M_ _ _ _-P-_ _ _ _ 87 BTL7-A-CB01-USB-KA 82, 143, 146, 118
BTL5-E1_-M_ _ _ _-SF-_ _ _ 227 BTL7-A-CB01-USB-S115 82, 143, 146, 118
BTL5-E5_0-M_ _ _ _-_-_ _ _ _ 173 BTL7-A-CB01-USB-S32 82, 143, 146, 118
BTL5-E504_0-M_ _ _ _-_-_ _ _ _ 217 BTL7-A-CB02 106, 174
BTL5-F1_ 0-M_ _ _ _-_-S115 161 BTL7-A-CB02-S115 106, 174
BTL5-F-2814-1S BAM014H 101, 113 BTL7-A-CB02-S32 106, 174
BTL5-G11-M_ _ _ _-P-_ _ _ _ 87 BTL7-C1_0-M_ _ _ _-_-_ _ _ _ 139
BTL5-H1_ _-M_ _ _ _-_-_ _ _ _ 155, 189 BTL7-C5_0-M_ _ _ _-_-_ _ _ _ 173
BTL5-H1_ _-M_ _ _ _-_-S92 153 BTL7-C504_0-M_ _ _ _-_-_ _ _ _ 217
BTL5-H1_ _-M_ _ _ _-_-S94 153 BTL7-E501-M_ _ _ _-_-_ _ _ _ 141
BTL5-H1_ _-M_ _ _ _-P-S92 93 BTL7-E501-M_ _ _ _-P-_ _ _ _ 81
BTL5-H1_ _-M_ _ _ _-P-S94 93 BTL7-G110-M_ _ _ _-_-_ _ _ _ 139
BTL5-M1-M_ _ _ _-P-_ _ _ _ 89 BTL7-G504-M_ _ _ _-_-_ _ _ _ 217
BTL5-M-2814-1S BAM014K 100, 112 BTL7-G510-M_ _ _ _-_-_ _ _ _ 173
BTL5-N-2814-1S BAM014L 100, 112 BTL7-P511-M_ _ _ _-_-_ _ _ _ 149
BTL5-P1-M_ _ _ _-_-_ _ _ _ 185 BTL7-S5_ _B-M_ _ _ _-_-_ _ _ _ 145
BTL5-P1-M_ _ _ _-P-_ _ _ _ 89 BTL7-S5_ _-M_ _ _ _-_-_ _ _ _ 145
BTL5-P-3800-2 BAM014M 99, 111 BTL7-S510B-M_ _ _ _-_-_ _ _ _ 145
BTL5-P-4500-1 BAM014P 99, 111 BTL7-S510-M_ _ _ _-_-_ _ _ _ 145
BTL5-P-5500-2 BAM014T 99, 111 BTL-A11-M_ _ _ _-HB/WB-_ _ _ _ 183
BTL5-S1_ _B-M_ _ _ _-_-_ _ _ _ 187 BTL-A-AD09-M-00EX 208
BTL5-S1_ _B-M_ _ _ _-P-_ _ _ _ 91 BTL-A-FK01-E-3/4"-16 UNF BAM0117 163
BTL5-S1_ _-M_ _ _ _-_-_ _ _ _ 187 BTL-A-FK01-E-M18×1,5 BAM0118 163
BTL5-S1_ _-M_ _ _ _-P-_ _ _ _ 91 BTL-C1-M_ _ _ _-HB/WB-_ _ _ _ 183
BTL5-T1_ 0-M_ _ _ _-_-S103 157 BTL-E1-M_ _ _ _-HB/WB-_ _ _ _ 183
BTL5-T1_ 0-M_ _ _ _-P-S103 97 BTL-G11-M_ _ _ _-HB/WB-_ _ _ _ 183
BTL5-T-2814-1S BAM01FC 113 BTL-P-0814-GR-PAF BAM013H 163
BTL6-_ _ _-M_ _ _ _-A1-S115 117 BTL-P-1012-4R BAM013J 163, 219
BTL6-A/B/E...-M...-E2/E28-KA_ _- ZA0_ 198 BTL-P-1012-4R-PA BAM013K 163, 219
BTL6-A/B/E...-M...-E2/E28-LA_ _-ZA0_ 198 BTL-P-1013-4R BAM013L 163, 219
BTL6-A110-M_ _ _ _-A1-S115 119 BTL-P-1013-4R-PA BAM013M 163, 219
BTL6-A301-M_ _ _ _-A1-S115 117, 121 BTL-P-1013-4S BAM013P 163
BTL6-A-3800-2 BAM014W 127 BTL-P-1014-2R BAM013R 163, 219
BTL6-A-3801-2 BAM014Z 127 BTL-P-1018-3R BAM01CE 162
BTL6-A500-M_ _ _ _-_ _ _-_ _ _ _ 195 BTL-P-1028-15R BAM013Y 163, 219
BTL6-A500-M_ _ _ _-PF-S115 107 BTL-S-3112-4Z BAM01A2 228
BTL6-A-MF01-A-43 126 BTM-_1_-_ _ _ 244
BTL6-A-MF01-A-50 126 BTM-H1_-_ _ _ 244
BTL6-A-MF03-K-50 126 LIF5Y-FC-5Y 227
BTL6-A-MF07-A-PF/M5 BAM01N3 110, 112
BTL6-B500-M_ _ _ _-_ _ _-_ _ _ _ 195
BTL6-C500-M_ _ _ _-PF-S115 107
BTL6-E500-M_ _ _ _-_ _ _-_ _ _ _ 195
BTL6-E500-M_ _ _ _-PF-S115 107
BTL6-G310-M_ _ _ _-A1-S115 119
BTL6-G500-M_ _ _ _-PF-S115 107
342
SENSOR
SOLUTIONS AND
SYSTEMS
As a recognized partner in all sectors of the automation industry, Balluff offers comprehensive
expertise in sensor technology and networking. We supply advanced technology and state-of-the-art
electronics to our customers, who benefit from excellent service, application-specific solutions and
individual consultation. You too can benefit from the excellent quality of our products and services.
www.balluff.com
Phone +49 7158 173-0
Linear Position Sensing and Measurement
Systems and Service
Industrial Identification
Object Detection
Accessories
Linear Position Sensing and Measurement
The appropriate measuring principle for the optimal solution
0 mm 48000 mm
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Tel. +49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de