Professional Documents
Culture Documents
Smartplant Electrical Installation & Configuration Checklist
Smartplant Electrical Installation & Configuration Checklist
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number
Install Database Software or verify that the Supported Database Platforms: See SmartPlant Engineering Manager
installed software is compatible with * Microsoft SQL Server 2012 Installation and Upgrade Guide:
* Oracle Database 11g R2 (11.2.0.4), 64-bit (Standard or Enterprise) Installing and Configuring Oracle or
2.0 Database Platform SmartPlant Electrical Database Server
Installing and Configuring Microsoft SQL
recommendations Server
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number
Verify that the network can be accessed Supports Internet Protocol IPv4 only
1.1 Operating System
Install SmartPlant Electrical Reference Data Delivered on the SmartPlant Electrical Installation DVD. To launch the Configuring Reference Data for Microsoft .Net Framework 4.0 is
SmartPlant Electrical setup, click the 'Additional Software' link on the SmartPlant Electrical SmartPlant Electrical > Install required for Reference Data
3.0 Installation Wizard 'Welcome' page and then click the 'SmartPlant SmartPlant Electrical Reference Data installation
Installation DVD Electrical Reference Data' link.
SmartPlant Electrical
Installation & Configuration Checklist
Software Version: 2015 (07.00.00) (SmartPlant Engineering Manager 2014 R1)
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number
Verify that the network can be accessed Supports Internet Protocol IPv4 only
1.1 Operating System
Microsoft .NET Framework 4.0 and 4.5 Microsoft .Net Framework 4.0 is required for launching the setup.exe file Loading SmartPlant Electrical If not already installed when
for SmartPlant Electrical and for connectivity when installing Oracle Client. Prerequisite Software installing SmartPlant Electrical, .NET
It must be installed before installing Oracle Client. Framework 4.0 will be installed with
the SmartPlant Electrical Setup.
Microsoft .Net Framework 4.5 is required for working with SmartPlant
Electrical. If Oracle Client was already installed
prior to installing .NET Framework
1.2 .NET Framework 4.5 Extended, refer to the Installation
Guide under the section: 'Before
You Install' > 'Loading SmartPlant
Electrical Prerequisite Software'
SmartPlant Electrical
Installation & Configuration Checklist
Software Version: 2015 (07.00.00) (SmartPlant Engineering Manager 2014 R1)
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number
Install Database Client Software or verify Supported Database Client: Hardware and Software The client database software must
that the installed software is compatible with * Oracle 11g R2 Client (11.2.0.4), 32-bit Recommendations > SmartPlant be of the same version as the server
Electrical Workstation database software.
SmartPlant Electrical Database Server
For SQL Server, no client installation is required.
recommendations Oracle 32-bit Client is required for
both 32-bit and 64-bit Oracle
2.0 Database Platform databases.
MSXML 6.0 Service Pack 1 or 6.0 Service Pack 3 Hardware and Software
Microsoft XML Recommendations > SmartPlant
3.2 Core Services Electrical Workstation > Software
(MSXML) Prerequisites
Required for reading the print documentation delivered with the software Hardware and Software
Recommendations > SmartPlant
4.2 PDF Reader Electrical Workstation > Software
Prerequisites
SmartPlant Electrical
Installation & Configuration Checklist
Software Version: 2015 (07.00.00) (SmartPlant Engineering Manager 2014 R1)
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number
Microsoft Excel (32-bit only) from Office 2010, SP1 Microsoft Excel is required for working with report templates and Hardware and Software
or generating reports. Recommendations > SmartPlant
4.4 Microsoft Office Office 2013 Service Pack 1 (32-bit only) Electrical Workstation > Software
Prerequisites
Citrix XenDesktop 7.0 RDS on Windows Server 2008 Needed for working in a thin-client environment Hardware and Software
R2 Service Pack 1, 64-bit (Standard or Enterprise) Recommendations > SmartPlant
4.5 Citrix Electrical Workstation > Optional
Software
Autodesk AutoCAD 2014 Used for viewing files generated using the 'Save As' feature Hardware and Software
Recommendations > SmartPlant
4.6 AutoCAD Electrical Workstation > Optional
Software
Visual Studio 2012 or 2013 Used for API Hardware and Software
Recommendations > SmartPlant
Integrated Development
4.8 Electrical Workstation > Optional
Environment (IDE)
Software
Delivered on the SmartPlantElectrical Installation DVD. Installing the Software > Install
SmartPlant Electrical SmartPlant Electrical
5.0 Install SmartPlant Electrical Software
Installation DVD
SmartPlant Electrical
Installation & Configuration Checklist
Software Version: 2015 (07.00.00) (SmartPlant Engineering Manager 2014 R1)
Installation of this version is from a DVD or a set of files downloaded from Intergraph's eCustomer web site.
Unless otherwise specified, the topics listed in the Documentation Reference column can be found in the SmartPlant Electrical Installation Guide.
The checklist below applies to the standalone installation of SmartPlant Electrical. For guidelines about using SmartPlant Electrical in an integrated
environment, see the SmartPlant Foundation Installation and Configuration Checklist.
Note: To run SmartPlant Electrical you must connect to a site and plant that were created using SmartPlant Engineering Manager. A plant created in
SmartPlant Engineering Manager with the SmartPlant Electrical application associated is a prerequisite for being able to use SmartPlant Electrical.
Task
Component or Tool Step Description / Software Version Details Documentation Reference Setup Notes
Number