3. All the access platforms and associated equipment are electrically grounded.
7. Only approved spark-proof lamps and torches are in the work area.
9. The tank entry person and the safety person each have two air-supplied
respirators that operate satisfactorily.
10. Both the tank entry person and the safety person have:
- The medical assessment that is applicable to your Local Regulations for entry into tanks.
11. Lint free cloths and special fire-proof containers are available
to remove all remaining fuel.
12. There is a continuous flow of clean filtered air through the fuel tank
available when the person is in the tank.
14. The correct fire fighting equipment and approved persons are available.
Meter Reading
I confirm that all entry requirements were met before entry was made into the tanks.