You are on page 1of 6

Radio Unit Description

RUS 02

RUS 02 - Radio Unit Description Rev A


Radio Unit Description

Contents
1 Product Overview
1.1 Purpose
1.2 Variants
1.3 Warranty Seal

2 Function Description

3 Technical Data

4 Signal and Power Interfaces


1 Product Overview
This document describes the Radio Units (RUs) for RBS 6000 systems.

1.1 Purpose
The main purpose of the RU is to send and receive signals.

The RU receives digital data and converts it to analog radio signals. It also receives radio
signals and converts these to digital signals.

RUs support Frequency-Division Duplex (FDD) only. For the technical attributes of the
radio units, see Section 3.

Figure 1 shows the interface of the RU.

Figure 1 RUS 02 Front

RUS 02 - Radio Unit Description Rev A  Ericsson AB 2015 3 (6)


Ericsson Internal
1.2 Variants
The following variants are available:

 RUS 02 B1
 RUS 02 B2
 RUS 02 B3
 RUS 02 B5
 RUS 02 B8
 RUS 02 B28A
 RUS 02 B28B

1.3 Warranty Seal


The unit is equipped with a warranty seal sticker.

Note:
Seals that have been implemented by Ericsson shall not be broken or removed, as it
otherwise will void warranty.

2 Function Description
The RU is certified for 60 W and 80 W. The default output power without license keys is 20
W. License keys are used to set the output power to 40 W, 60 W or 80 W.

Note:
For 80 W output power, besides a license key, it is required that the hardware has 80 W
capability.

The RU has the following functions:

 Transceiving Processing
 Uplink and downlink filtering
 Power Amplifier (PA) functions
 Up to four carriers downlink and uplink with 2-RX diversity
 Supports the function Remote Electrical Tilt (RET)

Figure 2 shows a general example of the block diagram of an RU.

RUS 02 - Radio Unit Description Rev A  Ericsson AB 2015 4 (6)


Ericsson Internal
Figure 2 RU Block Diagram

3 Technical Data
Table 1 lists the technical data for the RUs.

Table 1 RU Technical Data


Maximum Nominal Output Frequency Dimensions
Technical Power Max. Heat Maximum
Data Dissipation Uplink
Without With Extended Uplink Downlink Band Height Width Depth Weight
[W] Attenuation(1)[d
License License Output [MHz] [MHz] [mm] [mm] [mm] [kg]
(Extended B]
[W] [W] with
Output)
License
[W]
1850 to 1930 to
RUS 02 B2 20 80 - 2 420(3) 350 61 326 7.3 -50 to +50
1910 1990
824 to
RUS 02 B5 20 80 100 869 to 894 5 400 350 61 326 7.13 -50 to +50
849
880 to
RUS 02 B8 20 80 100 925 to 960 8 400 350 61 326 7.3 -50 to +50
915
RUS 02 718 to
20 60 - 773 to 803 28A 400 350 61 326 7.4 -50 to +50
B28A 748
RUS 02 703 to
20 100 - 758 to 788 28B 400 350 61 326 7.6 -50 to +50
B28B 733

(1) The maximum uplink attenuation limit can also be affected by other radio limitations

(2) RRUS 11 for B12 has a bandwidth that is 2 MHz narrower than 3GPP. The supported frequency corresponds to
EARFCN (Channel Numbers) of 5,010 - 5,169 in downlink and 23,010 - 23,169 in uplink.

(3) For 80 W license.

RUS 02 - Radio Unit Description Rev A  Ericsson AB 2015 5 (6)


Ericsson Internal
4 Signal and Power Interfaces
Table 2 lists the details for the external interfaces on the RU.

Table 2 RU Front Interfaces


Marking Description Connector
Transmitting/Receiving RF
RF A
Feeder connection
7/16
Receiving RF
RF B
Feeder connection
RXA I/O RXA cross connect output, external input
RXA Out RXA co-site output QMA
RXB I/O RXB cross connect input, RXB co-site output
Fault. Red optical indicator.
F
Renamed to in later versions
O Operational. Green optical indicator. Renamed to in later versions
Information. Yellow optical indicator. Renamed to M or and changed color to
I blue in later versions.
Do not touch the Maintenance button when this indicator is blinking –
Fault. Red optical indicator.
Operational. Green optical indicator.
Information. Blue optical indicator.
Do not touch the Maintenance button when this indicator is blinking
Maintenance button. Do not touch when the Information indicator is blinking
Data 1
Gamma data and electrical CPRI FCI 20 pin
Data 2
Power -48 V DC Power

The I/O ports are configured individually by software as input or output.

RUS 02 - Radio Unit Description Rev A  Ericsson AB 2015 6 (6)


Ericsson Internal

You might also like