You are on page 1of 8

Calculation

Name 4455
Description
Mode Basic
Public No

Configuration
Site
Settings
Temperature 20 (fixed)
Expression (expression)
Remote Group (#1)
Overrides
Temperature 20 (fixed)
Expression Momentary Max (expression)
Property Group
Power Cable Standard
Area Standard mm2
Cable Size 10 mm²
Cable Length 50
Radio 4455 B2/B25 B66A; Radio Unit (Radio 4455 B2/B25 B66A is a d...)
Property Group
Number of Tx 4
Power level 30
Property Group
Number of Tx 4
Nominal Output Power 20
Radio Standard FDD-LTE
Property Group
Number of Tx 4
Power level 30
Property Group
Number of Tx 4
Nominal Output Power 20
Radio Standard FDD-LTE
Idle Load
Unit Average Power ConsumpAverage Utilized Output
Site 278 9 / 160
Remote Group (#1) 278 9 / 160
Cable Loss
Radio Units 278 9
1 × Radio 4455 B2/B25 B66A; Radio Unit 278 9 / 160
B2/B25 142 4 / 160
B66A 136 4 / 160

Typical Load
Unit Average Power ConsumpAverage Utilized Output
Site 369 33 / 160
Remote Group (#1) 369 33 / 160
Cable Loss
Radio Units 369 33
1 × Radio 4455 B2/B25 B66A; Radio Unit 369 33 / 160
B2/B25 189 17 / 160
B66A 179 17 / 160

Momentary Max
Unit Average Power ConsumpAverage Utilized Output
Site 774 160 / 160
Remote Group (#1) 774 160 / 160
Cable Loss
Radio Units 774 160
1 × Radio 4455 B2/B25 B66A; Radio Unit 774 160 / 160
B2/B25 402 80 / 160
B66A 372 80 / 160

ETSI Average
Unit Average Power ConsumpAverage Utilized Output
Site 417 52 / 160
Remote Group (#1) 417 52 / 160
Cable Loss
Radio Units 417 52
1 × Radio 4455 B2/B25 B66A; Radio Unit 417 52 / 160
B2/B25 214 26 / 160
B66A 203 26 / 160

ETSI Low
Unit Average Power ConsumpAverage Utilized Output
Site 278 9 / 160
Remote Group (#1) 278 9 / 160
Cable Loss
Radio Units 278 9
1 × Radio 4455 B2/B25 B66A; Radio Unit 278 9 / 160
B2/B25 142 4 / 160
B66A 136 4 / 160
ETSI Medium
Unit Average Power ConsumpAverage Utilized Output
Site 421 54 / 160
Remote Group (#1) 421 54 / 160
Cable Loss
Radio Units 421 54
1 × Radio 4455 B2/B25 B66A; Radio Unit 421 54 / 160
B2/B25 216 27 / 160
B66A 205 27 / 160

ETSI Busy Hour


Unit Average Power ConsumpAverage Utilized Output
Site 515 84 / 160
Remote Group (#1) 515 84 / 160
Cable Loss
Radio Units 515 84
1 × Radio 4455 B2/B25 B66A; Radio Unit 515 84 / 160
B2/B25 265 42 / 160
B66A 250 42 / 160

ETSI Full Load


Unit Average Power ConsumpAverage Utilized Output
Site 709 142 / 160
Remote Group (#1) 709 142 / 160
Cable Loss
Radio Units 709 142
1 × Radio 4455 B2/B25 B66A; Radio Unit 709 142 / 160
B2/B25 368 71 / 160
B66A 342 71 / 160
Heat Dissipation
270
270

270
270
138
132

Heat Dissipation
335
335

335
335
173
163

Heat Dissipation
614
614

614
614
322
292

Heat Dissipation
365
365

365
365
188
177

Heat Dissipation
270
270

270
270
138
132
Heat Dissipation
367
367

367
367
189
178

Heat Dissipation
431
431

431
431
223
208

Heat Dissipation
567
567

567
567
296
270
Power dimensioning result
Normal operation Cable voltage drop Uin
Remote Group (#1) - @ 20°C DC -52.5 VDC
Uout Iin
15 A
Cooling capacity
Cabinets Capacity Utilization

You might also like