The travel experience
F
or work or recreation, business or ■ Visual information accounts for 80 per-
pleasure – whatever the reason, all cent of all the information a human be-
sorts of people spend a great deal ing receives.
of time in hotels and guest houses, restau-
rants and bars. ■ Light makes the quality of our environ-
ment visible and impacts on our emo-
Whether the experience is a positive one tional and subconscious response.
depends on a lot of factors. But visual im-
pact is high on the list. ■ The rules of sensitive, practical lighting
Outside our normal environment our sens- design are complex.
es are particularly alert, ready to register Lighting designers offer special expert-
and store unfamiliar and positive new im- ise and solutions.
pressions.
1 2
W
e respond emotionally to the pres-
ence of light and enjoy intuitively
the different kinds of atmosphere
that daylight or artificial lighting creates.
3
1
Welcoming and catering for guests day and night
T
he quality of daylight has had a cru-
cial influence on the development
and capacity of the human eye. The
environmental requirements of our com-
plex visual organ are high – and so, there-
fore, are the quality standards that need to
be met by artificial lighting.
It would be wrong, however, for the lighting
designer to seek to copy the characteris-
tics of daylight.
5
2
Pages 38-39 Pages 40-41 Pages 42-43 Pages 44-46 Pages 47-48 Page 49
H
uman perception works on many
levels – a fact that particularly
needs to be borne in mind when
implementing plans for artificial lighting.
7
■ Artificial lighting plans need to take
account of the constant changes in day-
light.
6
3
People in hotels and restaurants
H
otels and restaurants are classic
service enterprises. As such, they
require a lighting atmosphere de-
signed specifically to meet guests’ or din-
ers’ needs.
9
4
S
taff at a reception desk, in a restau-
rant or bar, or anywhere else where
guests seek personal contact need
to be clearly visible and easy to identify.
Disturbing shadows should be avoided.
Where too much bright lighting is direct
and directional, deep shadows are cast on
faces.
For face-to-face communication, lighting
needs to be planned and crafted so that
facial features are bathed in soft, harmo-
nious light.
8 11
■ The perfect lighting design accurately
reflects the findings of a detailed analy-
sis of the different areas of the estab-
lishment.
10
5
Trends
12
I C
dentifying design trends for hotels and andlelight dinner. The challenge of Lighting today has become such a tech-
restaurants calls for a capacity for keen speaking to the soul. nologically complex subject that this kind
and sensitive observation and a great Let’s start with a quote from a light- of cooperation is imperative.
deal of creative imagination. ing designer: “Because luminaire manu-
Jan Wichers, who runs a design studio in facturers increasingly encounter architects It is more than just a matter of lighting con-
Hamburg, possesses both of these quali- with a desire to make a strong design cepts delivering the right quantity and
ties. statement, manufacturers’ architectural quality of light without undue energy costs.
A host of international contracts and acco- and custom lighting departments are get- It is more than a matter of intensity distri-
lades testify to his sense of style and the ting better all the time. They also work in- bution curves and illuminance diagrams.
quality of his work. Here, he muses on the creasingly with independent lighting de- It is primarily about developing lighting
subject of lighting. signers. atmospheres finely tuned to the diverse
The role that has been adopted by lighting and changing needs of a particular interi-
designers is that of interpreter between in- or design.
terior designer and electrical engineer. Good interior design speaks to the heart.
But they are also designers in their own And that calls for experience in this sensi-
right. They are specialists in lighting at- tive area – experience that makes it possi-
mosphere and lighting aesthetics.” ble to realise a vision.
The quote says it all. No architect should Creative, poetic design work is needed.
hesitate to engage specialists to optimise Perception of light and a sense of well-
the service he offers. being are key to a positive experience.
Lighting designers know about the impact
of light. They offer the experience that en-
ables a creative design, a vision to become
a reality.
And they do it a great deal better than
computers packed with technical data and
high-resolution graphics.
6
13 14
Because wrong use of light can deal a ■ In lighting design, emotional quality
deathblow to the heart and soul. That is comes first.
what happens when the emotional dimen-
sion is ignored. ■ Lighting designers are specialists in
lighting atmospheres and lighting aes-
Making effective use of light means also thetics and offer experience which
working with shadow, with darkness. make creative joint design work possi-
Acceptance depends on the different ble.
levels being right.
What counts is the emotional quality of the ■ Harnessing light also means working
lighting; light needs to work magic. with shadow.
Think of the magic in the phrase “candle-
light dinner”.
A warm, romantic atmosphere full of prom-
ise – created entirely by the light of a sin-
gle candle. The lighting required is minimal
but it needs to be crafted with care and
sensitivity. Through the retina to the soul –
direct. That is good lighting.
F
irst impressions are crucial – and
artificial lighting plays a key role in
determining what those impressions
are and where they are made.
16
15 17
F
oyers and halls are parts of the
building where people converge.
They form a link between outdoor
areas and the inside of the building.
18
8
19
■ Artificial lighting provides guidance for
guests and helps them get their bear-
ings.
20
Fördergemeinschaft Gutes Licht 9
Receptions
A
s far as the guest is concerned, the
reception is the organisational hub
of the hotel and it needs to be per-
ceived as such.
21
B
ut the external design of the recep-
tion should direct only the attention
of guests. For efficient communica-
tion at a reception – which can at times be
a very complex task – the quality of the
light illuminating those engaged in conver-
sation is a crucially important factor.
The directional downlighting normally in-
stalled here needs to be supplemented by
horizontal lighting to provide the vertical
illuminance needed to lighten the other-
wise harsh shadows. This makes for bal-
anced lighting on faces and the reception
counter.
23
10
22 24
■ The reception is the first place a hotel
guest makes for, so the lighting should
underline its status as the hub of the
hall.
25
11
Restaurants
L
ighting for areas where people eat is
primarily mood lighting. But it also
needs to ensure that guests can find
their way around and conduct conversa-
tions at the table while facing in any direc-
tion.
26
12
28
■ Artificial lighting underlines the restau-
rant concept.
29
13
27
Restaurants
R T
estaurant lighting should be low- he lighting designer also needs to
key for all service areas except buf- pay attention to the colour rendering
fets; the emphasis should be on the properties of the lamps used in the
arrangement of tables. luminaires.
This is because good colour rendering is
At the same time, it should be assumed that essential for ensuring that the freshness
the "observer principle" applies, i.e. that and delicacy of food is immediately ap-
people prefer all active areas to be cast in parent.
a brighter light than themselves.
Like light colour, colour rendering is stan-
In a restaurant context, this means the sur- dardised. It is expressed as a colour ren-
face of the table should be more brightly lit dering index Ra, based on the rendering of
than the surroundings, though guests test colours commonly found in the envi-
should still be able to make one another ronment. Ra = 100 is the best possible val-
out clearly. ue; the lower the index, the poorer the
colour rendering properties.
In restaurants and kitchens, a minimum of
Ra 80 is required; Ra 90 is better.
30
31
14
34
32
35
■ The level of brightness on the table
needs to permit visual appraisal of the
quality of the food.
33
15
Bistros and bars
36
T
he design of bistro and bar lighting
should be based on precise analy-
sis of the groups the establishment
wishes to attract. Depending on the in-
tended design statement, any of the whole
range of lamps and luminaire types avail-
able could be an option.
Where the intention is to appeal mainly to
a younger market, a wide variety of visual
effects will be needed to attract large num-
bers of customers.
37
16
38
■ While guests enjoy the emotional ele-
ments of the lighting concept, staff need
to be able to perform specific visual
tasks. Illuminance level, glare limitation
and colour rendering are important fac-
tors here.
40
17
39
Conferences and seminars
A
s the need for information grows
and mobility increases in modern
society, hotels face a rising tide of
demand for rooms specifically designed
for effective, professional communication.
41
18
43
44
C
ommunication is a process that ■ Room-darkening facilities need to be
involves all our senses and can be designed to permit total exclusion of
effective only where visual inter- daylight.
ference is ruled out.
So artificial lighting needs to be variable, ■ A combination of different lighting sys-
catering to needs ranging from group work tems and light colours enables lighting
at desks to note-taking during slide pre- to be tailored for various forms of room
sentations. use.
At the same time, to avoid too much light
falling in one plane – which can happen ■ Air-handling luminaires offer a perfect
where narrow-angle ceiling luminaires pro- solution for combining artificial lighting
vide an excessive lighting component – with ventilation or air-conditioning.
care needs to be taken to ensure that the
entire room is illuminated, including the ■ Groups using the room need to be able
walls and the ceiling. to regulate lighting and air-conditioning
Electronic lighting management systems themselves, so lighting management
are recommended here. systems should be local and preferably
designed for manual operation.
42
19
Corridors
C
orridors need to be regarded pri-
marily as circulating areas, where
the need for guidance and security
comes first. From a psychological view-
point, the impression of depth due to the
shape of the interior is not highly conducive
to a sense of wellbeing.
45 47
20
46 48
■ Corridors are also escape routes. Es-
cape route signs and escape route
lighting need to be installed and main-
tained in accordance with standards
(see also FGL booklet 10).
49
Fördergemeinschaft Gutes Licht 21
Staircases and elevators
50
S
taircases are often designed for
prestige but their basic function still
needs to be a primary considera-
tion: first and foremost, stairs have to be
safe for those who use them.
To make for safe visual conditions on a
staircase, artificial lighting needs to be de-
signed so that no treads are obscured by
shadows.
For a user looking down or up the stairs,
there must be no risk of luminaires caus-
ing glare or distracting attention.
One principle that applies to all lighting
designs is particularly important for stair-
cases. Low-reflectance surfaces, such as
dark carpets or stone steps, call for higher
design illuminances to be clearly made out.
51
22
53
54
T
ravelling in an elevator is often an ■ Staircases are also escape routes. Es-
uncomfortable experience because cape route signs and escape route
if it is enclosed, it can be claustro- lighting need to be installed and main-
phobic and if its walls are transparent, like tained in line with standards (see also
the glass elevators integrated into halls, it FGL booklet 10).
can easily trigger fear of heights.
Such phenomena occur partly as a result ■ Staircase treads should not cast shad-
of visual confusion – confusion which can ows over the next tread down. Before a
be reduced by the colour scheme and lighting design is prepared, the bright-
brightness of the elevator entrance and ness and colour of the floor covering
interior. needs to be defined.
Even outside the elevator doors, a greater
sense of security can be promoted by a ■ LED luminaires are an option for illumi-
significantly higher level of brightness. nating staircase treads and are espe-
Inside the elevator, the colour scheme cially suitable for escalators. High main-
should be bright and walls and ceiling tenance costs here are substantially re-
should be lined with mirrors or shiny pan- duced as a result of the shock resist-
els to suggest more space. ance and long service life (approx.
The lighting should be largely diffuse to 50,000 hrs) of LEDs.
avoid hard-edged distorting shadows on
the faces of elevator users. ■ Elevator entrances should be designed
to be inviting by raising the level of
brightness above that of the surround-
ings. Inside elevators, lighting should be
largely diffuse to avoid harsh, distorting
shadows.
52
23
Rooms and suites
T G
he majority of hotel guests use their uests should be able to select and
rooms mainly in the evening and at regulate the level and distribution of
night, so lighting plays a particularly brightness in the room to suit their
important role here. mood.
Lighting design for hotel rooms and suites Convenience is significantly heightened by
should be geared primarily to the need for central light switches at the entrance to the
ambience and comfort, which in lighting room and also at the bed.
terms means luminaires which are individ- It must also be remembered that older peo-
ually switched and regulated to cater for dif- ple need considerably more light than
ferent room uses. young ones, so the psychological impres-
The various zones of the room are defined sion of brightness a hotel room makes dif-
and signalled to the guest primarily by the fers significantly according to the guest’s
room furnishings. That structuring can be age.
further emphasized by lighting scenes pro- For this reason alone, individual dimmer
grammed to produce various arrange- control is recommended for regulating
ments of accentuating light. lighting levels.
To enhance the overall impression made
by the room, quality of design should be a
priority when selecting luminaires.
56
24
57
55 58
■ Hotel rooms and suites have a wide va-
riety of function zones (for working,
reading, watching TV, resting, sleeping,
etc.). The lighting thus also needs to be
multifunctional.
59
Fördergemeinschaft Gutes Licht 25
Rooms and suites
I
t is particularly important in a hotel room
or suite to ensure that the lighting is
planned with the interior design and the
furnishings of the room in mind.
This is because the illuminance required
depends on the reflectance of the surfaces
of walls, ceiling, floor and furniture.
60
26
62
63
■ The illuminance required in a room de-
pends on the reflectance of the materi-
als and finishes present.
61
27
Bathrooms
B
athrooms are required to serve dif-
ferent purposes at different times of
the day. In the morning, guests want
a bright, invigorating atmosphere to start
the day; in the evening, they prefer a
warmer ambience.
With different luminaire systems of different
light colours, bathroom lighting can easily
be adapted to meet these requirements.
Lighting control, however, should go be-
yond mere on/off switching; it should offer
the possibility of activating and individual-
ly dimming programmed lighting scenes.
65
64
28
67 68
M
irror lighting should be provided
by glare-free luminaires for both
vertical and horizontal lighting in
a mix designed to prevent harsh shadow-
ing on the face and body of the guest.
The use of just two narrow-beam down-
lights set in the ceiling over the guest's
head produces precisely the lighting situa-
tion which should be avoided. If that base
lighting is supplemented by diffuse lumi-
naires (e.g. with white opal enclosures)
mounted on the wall, however, a harmo-
nious distribution of light is achieved.
Beauty care at a mirror calls for lamps with
good colour rendering properties (Index
Ra 80 or Ra 90).
I
n today’s health- and leisure-oriented Planning underwater lighting to enhance
society, pools and saunas, activity the visual impact of a pool, intensifying the
zones and rest areas are considered effect by lowering the brightness of the sur-
an intrinsic part of the modern hotel serv- roundings and using the surface of the wa-
ice package. ter to produce decorative reflections calls
Here, the special challenge for the lighting for a great deal of experience with light and
designer lies in enhancing the experience a detailed knowledge of the specific room
provided by these facilities. situation.
Punctual light sources lend brilliance to
gleaming, tiled surfaces. Pillar lighting is used to grab attention.
The visual impact of cleanliness and hy- The aim here is to emphasize the weight of
giene is heightened by raising the bright- the pillars by modelling – not to create a
ness level and using lamps of cooler light two-dimensional scene with diffuse light.
colour ( 4000 K). Pool facilities with glass walls appear more
Harnessing the capacity of water to pro- spacious at night if the garden areas out-
duce interesting lighting effects calls for doors are illuminated.
the services of a specialised lighting con-
sultant.
70
30
69 73
■ Depending on the lighting, water can
have a dramatic impact or look like a
gently flowing stream.
71 72
Fördergemeinschaft Gutes Licht 31
Offices
T
here are basically three forms of
lighting for offices in administrative
areas.
Room-related lighting: ceiling luminaires
make for uniform brightness throughout
the room.
Task area lighting: where different visual
tasks are performed in different parts of a
room, their different lighting requirements
can be met.
Task zone lighting: supplementary lighting
is used to raise the level of lighting to meet
the requirements of a specific visual task
performed in a particular part of the task
area.
74
G
For office work, a minimum of 500 lx illu- ood glare limitation is a must in any
minance is required. This level of bright- room where work is performed –
ness can be achieved using a combination but especially at VDU workplaces.
of direct and indirect lighting or with direct Direct glare, e.g. from an unshielded ceiling
lighting alone. luminaire or other highly luminant surfaces
Most people find the light of pendant lumi- such as windows, is avoided by using suit-
naires or standard luminaires for direct/in- ably designed luminaires and positioning
direct lighting particularly agreeable. Good luminaires and workplaces correctly.
uniformity is more easily achieved with a di- Reflected glare occurs where light is re-
rect general lighting system comprised of flected into the eye by shiny surfaces, e.g.
recessed ceiling, surface-mounted ceiling screen reflections. To avoid reflected glare,
or pendant luminaires. The highly direc- monitors should be set at an angle to lu-
tional light emitted by these luminaires is minant surfaces such as windows, lumi-
distributed by specular louvers, thus en- naires or bright walls – where they exceed
suring the necessary glare limitation. a luminance of 1000 candelas/m2 – so that
disturbing reflections cannot appear on the
screen.
76
32
75 78
■ The lighting design requirements for of-
fices are set out in DIN EN 12464-1, DIN
5035 Parts 7 and 8 as well as the
national ordinance protecting employ-
ees working at VDUs (Bildschirmar-
beitsverordnung). Mean illuminance
needs to be at least 500 lx. Detailed
information can be found in FGL book-
let 4 “Good Lighting for Offices and Of-
fice Buildings”.
77
Fördergemeinschaft Gutes Licht 33
Kitchens and utility rooms
K
itchens and utility rooms are used
for preparing and cooking, clean-
ing and restoring what will later be
presented to guests for appraisal.
Whether this is a culinary delicacy or an
item of clothing, kitchen and utility room
lighting needs to ensure the visual condi-
tions required for safe and reliable handl-
ing by staff.
79
As well as having to conform to the rele-
vant standards (e.g. DIN EN 12464-1), light-
ing here needs to comply with the stipula-
tions of ASR workplace regulations.
To do so, these rooms require a glare-free
lighting system delivering 500 lx mean il-
luminance.
34
W
here the act of cooking is a signal
event, the lighting design param-
eters are different. In this situation,
the guest is again the prime consideration.
A culinary performance is like a stage pro-
duction: it needs to be enjoyed without dis-
traction or glare.
For participants too, the level of brightness
needs to be high enough to ensure that the
task can be performed safely and surely.
80 82
■ Kitchens and utility rooms are governed
by ASR workplace regulations and DIN
EN 12464-1. They require bright, uni-
form lighting (mean illuminance 500 lx).
81
35
Façades and outdoor areas
83
T F
he illuminated exterior of a building loodlighting a building from outside
at night does more than boost pres- and below can make it look very
tige; it also helps guests get their solid; illumination from inside can
bearings. A building identified from afar as lend it an open, filigree appearance.
a place for hospitality guides guests swift- Façade illumination does not necessarily
ly and easily to the door, makes an agree- have to follow the lines and contours of the
able impression and leaves behind a architecture.
pleasant memory. Artistic night lighting can ignore architec-
tural and constructive details and craft a
However, night lighting finely tuned to the totally new image for the observer.
architecture also has an enduring positive A particularly interesting effect here is
impact on the image of the establishment. achieved where lighting is activated before
daylight fades. The observer thus witness-
es an architectural transformation as dark-
ness descends.
36
D
uring the warmer months of the
year especially, the outdoor areas
of hotels and restaurants possess
considerable allure.
In the dark, the human eye is particularly
susceptible to glare; subliminal discomfort
results.
So lighting for outdoor facilities needs to be
planned with particular care.
Even very low illuminances are found
bright enough when our eyes have adapt-
ed to the dark.
Direct eye contact with lamps needs to be
avoided at all times in the main viewing di-
rections. In restaurants with seating out-
doors, glare is a particularly important as-
pect.
1, 2 Incandescent lamps
The traditional incandescent lamp is still the most widely used light 1 2
3
source of all. This is due in part to the wide range of different units
available. Reflector and bowl reflector lamps provide decorative
directional lighting. Incandescent lamps emit an agreeable warm-
white light with good colour rendering properties and can be
dimmer-controlled. Their luminous efficacy, however, is relatively
low and their service life short. 11 12 13
3, 4, 5, 6 Tungsten halogen lamps (230 Volt)
Tungsten halogen lamps for 230 V line voltage produce an agree-
able white light with very good colour rendering properties. Their
service life is longer than that of incandescent lamps and their
luminous efficacy higher. Dimming control presents no problems.
They are also available as reflector lamps.
9, 10 Energy-saving lamps
Energy-saving lamps are compact fluorescent lamps. They are
nearly the same size as incandescent lamps and have the same
screw base (E14/E27). The electronic ballast (EB) required is in-
tegrated in the lamps. Energy-saving lamps consume 80% less
power and have a considerably longer life than incandescent
lamps.
Illus- Lamp type Power
11, 12, 13, 14 Compact fluorescent lamps tration rating
Unlike energy-saving lamps, compact fluorescent lamps have a No. (Watts)
plug-in base; the ballast needs to be integrated in the lamp. Com- Incandescent lamps
pact fluorescent lamps have the same characteristics as three- 1 Reflector lamps 30 – 100
band fluorescent lamps. Here, too, luminous efficacy is improved, 2 Bowl reflector lamps 40 – 100
service life lengthened and visual comfort heightened by EB Tungsten halogen lamps (230 V)
operation. Lamps can be dimmed by dimmable EBs. 3 With jacket 25 – 250
4 Mini-format 25 – 75
15, 16 Metal halide lamps
5 With base at both ends 60 – 2.000
These high-pressure discharge lamps are noted for their high
luminous efficacy and excellent colour rendering properties. With 6 With reflector 40 – 100
modern metal halide lamps with a ceramic burner, light colour re- Low-voltage tungsten halogen lamps (12 V)
mains constant throughout the life of the lamp. Inductive ballasts 7 With reflector 20 – 100
and starters or EBs are needed to operate metal halide lamps. 8 Pin-based 5 – 100
Energy-saving lamps
17, 18, 19 Linear three-band fluorescent lamps 9 Candle-shape 5 – 12
Three-band fluorescent lamps are noted for their high luminous 10 Incandescent-shape 5 – 23
efficacy, good colour rendering properties and long service life. Compact fluorescent lamps
Operated by electronic ballasts (EBs), they achieve even higher 11 2-, 4- and 6-tube lamp 5 – 120
luminous efficacy, a longer service life and greater visual comfort.
12 2-tube lamp 18 – 80
16 mm diameter lamps are designed for EB operation only.
Dimming control of three-band fluorescent luminaires is possible 13 4-tube lamp 18 – 36
with appropriate EBs. 14 2D-lamp 10 – 55
Metal halide lamps
20 Light-emitting diodes (LEDs) 15 With base at one end 35 – 150
LEDs are available in numerous shapes and colours. They are 16 With base at both ends 70 – 400
extremely small, have a high resistance to impact and emit nei- Linear three-band fluorescent lamps
ther IR nor UV radiation. They have a very long service life. LEDs 17 16 mm diameter with high luminous efficacy1) 14 – 35
with a special fluorescent coating produce white light. The most 18 16 mm diameter with high luminous flux1) 24 – 80
important lighting applications at present are in orientation and 19 26 mm diameter 18 – 58
decorative lighting. LEDs are designed for d.c. operation.
Light-emitting diodes (LEDs)
20 Individual LEDs4) 0,7 – 5
Light colour:
ww = warm white, nw = neutral white, dw = daylight white
38
4 7
6
6
3
5
8 9
10
14 15
17+18
19
16 20
– – ww 90 E14; E27
– – ww 90 E14; E27
– – ww 90 GU5,3
60 – 2,200 12 – 22 ww 90 G4; GY6,35
18 – 120 13 – 24 – – –
1) For EB operation only 3) Luminous efficacy increases to 81 – 100 lm/W with EB operation.
2) Luminous flux at 35°C 4) The illustration shows individual LEDs on a flexible printed-circuit board.
39
Lighting management
L
ighting management offers huge
scope for creating optimal lighting
constellations for different times of the
day and year – especially in hotels and
restaurants.
The planning for any lighting management
system should focus on human needs and
expectations.
Lighting management systems enable us
to tailor the lighting climate in a room to our
current requirements – much in the same
way as we mix hot and cold tap water to
get the cold, lukewarm or hot water we
want.
I
n addition to these aspects, attention
should also be paid to the economic
advantages of a lighting management
system.
Considerable energy savings can be made,
for example, by the integration of presence
or light sensors.
In hotels, in particular, communication
routes to rooms are rarely used during the
day. With presence sensors, lighting can be
switched on when it is required; there is no
need for maintained lighting. For initial ori-
entation, however, a basic level of illumi-
nance is required, which can be provided
by residual brightness from main corridor
lighting or the emergency lighting in the
corridor itself.
40
L
ighting management permits fast,
variable and dependable lighting
scene adjustment to suit different
forms of room use – something which is
particularly useful in the seminar and con-
ference rooms and multi-purpose rooms
found in hotels and catering establish-
ments.
From family parties to receptions and as-
semblies, from seminars and meetings to
lectures and slide, video or beamer pre-
sentations – different events and activities
call for different visual conditions. Depend-
ing on the multifunctional lighting compo-
nents installed, lighting management offers
the possibility of switch or handset control
to vary illuminance, luminance distribution,
direction of light, modelling and light colour.
Every anticipated lighting situation can be
planned, tested and stored in advance and
then activated at any time.
In addition, all the lighting scenes defined
in this way can be manually modified and
87 90 adjusted to meet the specific lighting re-
quirements of guests.
T
he internationally standardized digi-
tal interface DALI (Digital Address-
able Lighting Interface) is designed
to facilitate flexible lighting management in
individual rooms or small building units. As
an independent system or integrated into
a building management system, DALI
controls switching and dimming functions
and verifies the availability of connected
components.
L
ighting is governed by a host of reg- their way along escape routes as well as
ulations and standards which can Kitchens and utility rooms in corridors, stairwells and exits even if the
seem like an impenetrable jungle to Lighting systems for kitchens and utility general lighting should fail completely.
the layman. So owners, planners, installers rooms primarily need to be protected The same requirement can also apply to
and operators of lighting systems in hotels against the ingress of water. Where a smaller establishments where orientation
and restaurants should always seek expert steamy atmosphere may be present, the is difficult or where there is no natural
advice and demand appropriate guaran- 2nd numeral of the degree of protection lighting.
tees from the specialists they engage. should be at least 1. Where hosepipes or
The safety of guests and prevention of in- high-pressure equipment are used for
dustrial accidents need to be assigned top cleaning, the 2nd numeral of the degree
priority. This obligation can be seen from of protection should be at least 4. (DIN
the examples on the right showing the reg- VDE 0100-559).
ulations that apply to certain lighting appli-
cations.
E
mergency lighting is essential for
bridging power cuts that affect the Temperature symbols
general lighting. Emergency lighting
is a standardised term covering both stand- Symbol Meaning
by lighting and safety lighting.
Standby lighting ensures that important Luminaires for mounting on building parts non-flammable up
operations are maintained and provides to 180°C.
the minimum general lighting required
until the fault is cleared.
As F symbol, but suitable for use with thermal insulation
backing.
S
afety lighting is a blanket term
covering safety lighting for escape
routes and particularly hazardous Luminaires for mounting in/on furniture where the mounting
workplaces as well as anti-panic lighting. surface is non-flammable up to 180°C.
At particularly hazardous workplaces, for Important note: mounting instructions must be observed
example, detail identification (safe termina-
tion of operations, recognition of safety Luminaires for mounting in/on furniture where the mounting
colours) still needs to be assured even surface is non-flammable up to 95°C in normal operation.
after normal power supply fails. Important note: mounting instructions must be observed
42
Laws and ordinances – BGR 216 “Optical emergency guid-
Classes of protection ■ Workplace Ordinance (Arbeitsstätten- ance systems”, which includes safety
Luminaires need to offer protection verordnung) lighting, for trade and industry
against electric shock. There are three The law concerning the design of work ■ Industrial Health and Safety Ordinance
admissible classes of protection for this: premises is based on the Workplace (Betriebssicherheitsverordnung)
Class I , Class II and Class III. Luminaires Ordinance (Arbeitsstättenverordnung) “Ordinance governing the health and
can be assigned to only one class. of 12 August 2004, issued pursuant to safety aspects of the provision and use
Article 18 of the Occupational Health of materials at work, the operation of
and Safety Act (Arbeitsschutzgesetz). equipment requiring supervision and
Among other things, the Workplace Or- the organisation of occupational health
Symbol Meaning dinance transposes the European Di- and safety precautions” of 27 Septem-
rective 89/654/EEC on “minimum safe- ber 2002 (effective as of 3 October
ty and health requirements for the work- 2002). The ordinance was issued on the
Class I unit place” into national law. Its purpose is basis of Art. 18 of the Occupational
with protective to ensure that work premises are Health and Safety Act (Arbeitsschutzge-
conductor equipped and maintained to avoid ex- setz). Among other things, it transposes
terminal posing employees to health and safety the European Directive 89/655/EEC on
hazards. “minimum safety and health require-
Technical rules set out in Workplace ments for the use of work equipment by
Class II unit Regulations (Arbeitsstättenrichtlinien) workers at work” into national law.
with protective help define in more concrete terms ■ Electromagnetic Compatibility Act
insulation how the requirements of the Workplace (EMV)
Ordinance can be fulfilled. This act applies to appliances which
The Workplace Regulations developed can cause electromagnetic interfer-
Class III unit for the present Workplace Ordinance, ence or whose operation can be im-
for operation on which include paired by such interference. It trans-
protective – ASR 7/3 “Artificial lighting” poses the European Directive 89/
extra-low voltage – ASR 7/4 “Safety lighting” 336/EEC on the “approximation of the
will remain valid until revised and until laws of the EU Member States relating
new technical rules are published, but to electromagnetic compatibility” into
Degrees of protection only for a maximum of six years after the national law.
Degrees of protection indicate the extent Workplace Ordinance came into force.
to which a product is protected against For the trade and industrial sector, trade em- Standards and other technical
the ingress of foreign bodies and mois- ployers’ liability insurance associations have regulations
ture. They consist of the code letters IP issued the following regulations to define the ■ DIN EN 12464-1 “Light and lighting –
(Ingress Protection) and two numerals. requirements of the Workplace Ordinance in Lighting of work places, Part 1: Indoor
The first numeral indicates the degree of more concrete terms (in line with Article 15 work places”
protection against foreign bodies and of the Social Security Code, Book VII): ■ DIN EN 60598 series “Luminaires”
contact, the second numeral defines – BGV A1 “Principles of prevention” for ■ DIN VDE 0100 “Regulations governing
protection against water. the prevention of accidents in the in- electrical installations with a rated volt-
dustrial sector age up to 1000V”
– BGV A8 “Health and safety markings ■ DIN VDE 0108 “Power installations and
at workplaces” in trade and industry safety power supply in communal fa-
cilities”
■ DIN 4844 series “Safety marking”
Degree of protection ■ DIN 67528 “Lighting of parking areas
and indoor car-parks”
1st numeral 2nd numeral ■ Technical requirements for low-voltage
protection against foreign bodies water protection mains connection (TAB)
0 unprotected 0 unprotected TAB regulations govern all systems
1 protected against foreign 1 protected connected to and operating on power
bodies 50 mm against drops of water utility low-voltage mains. Among other
things, they contain stipulations for the
2 protected against foreign 2 protected against
bodies 12mm drops of water below 15° electrical connection of luminaires, e.g.
requirements to prevent interference
3 protected against foreign 3 protected against with AF remote control systems.
bodies 2.5mm spraywater ■ Technical regulations for elevators
4 protected against foreign 4 protected against (TRA)
bodies 1.0 mm splashwater TRA 200 “Passenger elevators – freight
5 protected against dust 5 protected against jets of water elevators”
6 dustproof 6 protected against floodwater
ENEC test symbol
7 – 7 protected against the ENEC (European Norms Electrical Certifi-
effects of immersion cation) is a European test and certification
8 – 8 protected against the symbol for luminaires and electrical com-
effects of submersion ponents in luminaires. It is displayed along
with the logo and identifying numeral of the
Example: IP 23 = protected against foreign bodies 12 mm and spraywater relevant national testing agency. The test
institute in Germany is the VDE, which is
identified by the numeral “10”.
T
he following projects were re- 7 Project: 15 Project:
searched and made available in Hotel Havana Palace, Barcelona Hotel Side, Hamburg
good faith by members of Photo: Architecture:
Fördergemeinschaft Gutes Licht (FGL). In FGL Matteo Thun, Milan
the general interest of the association, man- Lighting:
ufacturers and products have not been 8 Project: Robert Wilson, New York
named. Hotel Adlon, Berlin Photo:
If you would like more information about Architecture: Andrea Flak, Hamburg
specific photographs, please contact Patzschke, Klotz + Partner,
Fördergemeinschaft Gutes Licht, which will Munich 16 Project:
be pleased to help with any requests. Lighting: Hotel Hübner,
Licht Kunst Licht, Bonn/Berlin Rostock-Warnemünde
Photo: Lighting:
Bernd Hoff Michael Kurtius, Hamburg
Cover photograph Photo:
Project: 9 Project: Foto Design Latzel, Ahnatal
Restaurant Karren, Dornbirn Holiday Inn Crown Plaza,
Photo: Dortmund 17 Project:
Atelier Filler, Bregenz Active-Club Lobby IKB Deutsche
Architecture: Industriebank AG, Düsseldorf
1 Project: Rainer Kimpel Architecture:
Harvey Nichols Restaurant in Lighting: Siegfried Müller, Maja Djordjevic-
Oxo Tower Building, London Rheinelektra Müller, Werner Krehl, Stuttgart
Architecture: Photo: Lighting:
Lifschutz Davidson, London Holiday Inn Crown Plaza, Kress & Adams, Cologne
Lighting: Dortmund Photo:
Equation Lighting Design, London Active-Club Rainer Mader, Cologne
Photo:
Bernd Hoff 10 Project: 18 See photo 3
Hotel Vitznauerhof
2 Project: Architecture: 19 Project:
Max Car-Bar, Lucerne G. Kostrewa Enterprise Hotel, Mailand
Architecture and lighting: Photo: Architecture:
Ramseyer+Steiger, Bern Atelier Filler, Bregenz Cristina di Carlo (2002)
Photo: Lighting:
Thomas Mayer 11 Project: Christopher Redfern
Hilton Morumbi, Sao Paulo Photo:
3 Project: Architecture: Santi Caleca
Grandhotel Quellenhof, Bad Ragaz Botti-Rubin, Sao Paulo,
Architecture: Daniel Piana & Associates, 20 Project:
Karl Steffen Buenos Aires Quality Hotel Toensberg, Oslo
Lighting: Interior design: Architecture:
Peter AG Daniel Piana & Associates, Arthur Buchardt (2002)
Photo: Buenos Aires Photo:
Atelier Filler, Bregenz Lighting: Santi Caleca
Theo Kondos, New York
4 Project: Photo: 21 Project:
Radisson SAS Hotel, Cologne Rogerio Reis Sparkasse Neuss
Architecture and lighting: Architecture:
k/h Büro für Innenarchitektur und 12 Photo: Büttner and Musiol, Düsseldorf
Design, Mönchengladbach Studio Jan Wichers, Hamburg Lighting:
Photo: Brandi Ingenieure, Cologne
Andrea Flak, Hamburg 13 Project: Photo:
Mövenpick Hotel, Berlin FGL
5 Project: Architecture and lighting:
Hotel Residenz Hafen, Hamburg IDA 14, Zürich 22 See photo 4
Architecture: Photo: Photo:
Meyer & Fleckenstein, Hamburg Andrea Flak, Hamburg arge lola, Stuttgart
Lighting:
Schlotfeldt Licht, Hamburg 14 Project: 23 Project:
Photo: Theaterkeller, Munich Dorint Kongresshotel, Cologne
Andrea Flak, Hamburg Lighting: Architecture and lighting:
Studio Jan Wichers, Hamburg with Büro Markus Diedenhofen,
6 Project: Hamburg Design, Hamburg Reutlingen
Hotel Allegro, Bern Photo: Photo:
Architecture, lighting and photo: Studio Jan Wichers, Hamburg Döring & Kern, Wuppertal
Rast Architekten, Bern
24 See photo 3
44
25 Project: 41 Project: 51 Project:
Parkhotel Riter, Munich Samediggi Claudius Therme, Cologne
Photo: (Saami Parliament) Photo:
FGL Architecture: FGL
Stein Halvorsen, Christian
26 Photo: A. Sundby 52 Project:
FGL Lighting: Forum Bonn
AS Rasmussen & Stramd Architecture:
27 Project: Photo: HPP Hentrich-Petschnigg und Partner
Golfhotel, Speyer Thomas Mayer Lighting:
Lighting: Kress & Adams
Ziplight, Plankstadt 42 Project: Photo:
Photo: Forum, Dornbirn FGL
Studio 3, St. Augustin Architecture:
Baumschläger + Eberle 53 Project:
28 See photo 6 Photo: Schüco, Bielefeld
G. Latznia, Bregenz Architecture:
29 See photo 17 Wannenmacher & Moeller, Bielefeld
43 Project: Lighting:
30 See photo 13 S-Finanzzentrum, Erfurt Mies & Reichelt, Bielefeld
Architecture: Photo:
31 See photo 3 Schweger & Partner, Hamburg Michael Wortmann
Lighting:
32 Project: Schlotfeldt Licht, Hamburg 54 See photo 15
Parkhotel Weggis, Photo:
Aldopark AG, Weggis Andrea Flak, Hamburg 55 Project:
Architecture: Messe Trendhotel, Hanover
Vincenz Erni, Aldopark AG, 44 See photo 4 Architecture and lighting:
Weggis Studio Jan Wichers, Hamburg
Lighting: 45 Project: Photo:
Albert Steffen, Lichthalle AG, Sheraton Hotel, Frankfurt am Main Andrea Flak, Hamburg
Zurich Architecture:
Photo: United Designers Ltd 56 Photo:
Fabrikstudios AG, Lucerne Shad Thames, London (2001) FGL
Photo:
33 See photo 32 Santi Caleca 57 Project:
Gastwerk Hotel, Hamburg
34 Project: 46 See photo 3 Architecture:
Zurich Reinsurance Regina Schwethelm, Sybylle von
Architecture: 47 Project: Heyden
MB Architekten, Lachen Le Meridien Hotel, Turin Photo:
Lighting: Architecture: Andrea Flak, Hamburg
Polke Ziege von Moos, Zurich Renzo Piano
Photo: Photo: 58 Project:
Fotostudio Prisma, Melingen FGL Berghotel Astenkrone,
Winterberg-Altastenberg
35 See photo 23 48 Project: Architecture and lighting:
Michaelsberg Abbey, Siegburg Agentur Kretschmann, Bamberg
36 See photo 3 Architecture: Photo:
Schilling Architekten, Cologne Andrea Flak, Hamburg
37 Project: Lighting:
Hotel Metropol Kress & Adams, Cologne 59 Project:
Lighting: Photo: Dorint Hotel am Gendarmenmarkt,
Rigav Interieur, Emmen Rainer Mader, Cologne Berlin
Photo: Architecture:
Atelier Filler, Bregenz 49 Project: K/H Klein-Haller (1999)
Grand Hyatt Hotel, Hong Kong Photo:
38 Photo: Architecture: Soenne-Architekturfotograf,
FGL NG Chun Nun + Associates, Aachen
Hong Kong
39 See photo 6 Lighting: 60 See photo 55
Photo: Lightsource, Seattle
G. Latznia, Bregenz Photo: 61 Project:
Kerun Ip Steigenberger Graf Zeppelin,
40 Project: Stuttgart
Bar „Der Widder“, Zurich 50 Project: Architecture:
Architecture: Wempe, Hamburg Bärbel Thorer, Frankfurt am Main
Tilla Theus Photo: Photo:
Photo: Andrea Flak, Hamburg Steigenberger
FGL
46
T
97
94
100
legible.
ordered.
back page:
98
95
101
99
96
102
Numbering of photos on
Ordering booklets
Order form
Please indicate number of booklet(s) required. Prices given include postage. (e = available in English, E = available in English only as pdf-file,
download free of charge at www.licht.de): From Postcard Postage
Booklet No./Title Qty
stamp
Technical consultant:
Acknowledgements:
Beuth-Verlag GmbH
DIN-VDE standards:
Fördergemeinschaft
Stresemannallee 19
DIN EN standards:
westermann druck
Gutes Licht (FGL)
3-926 193-18-2
tion, Darmstadt
Braunschweig
02/05/00/11IV
10625 Berlin
10787 Berlin
Imprint
stipulations.
VDE-Verlag
Printed by:
Publisher:
Germany
Reprints:
posite.
ISBN:
T
fax:
11
Order form
Please indicate number of booklet(s) required. Prices given include postage. (e = available in English, E = available in English only as pdf-file,
download free of charge at www.licht.de): Postage
From Postcard
Booklet No./Title Qty stamp
1 Lighting with Artificial Light (7/04) E R 9,–
2 Good Lighting for Schools and Educational Establishments (7/03) E R 9,–
Name, Company, Office
3 Good Lighting for Safety on Roads, Paths and Squares (3/00) e R 9,–
4 Good Lighting for Offices and Office Buildings (1/03) E R 9,–
5 Good Lighting for Trade and Industry (4/99) E R 9,–
6 Good Lighting for Sales and Presentation (2/02) E R 9,–
7 Good Lighting for Health Care Premises (4/04) E R 9,–
Department
8 Good Lighting for Sports and Leisure Facilities (9/01) E R 9,–
9 Prestige Lighting (8/97) e R 9,– c/o
10 Notbeleuchtung, Sicherheitsbeleuchtung (4/00) R 9,–
11 Good Lighting for Hotels and Restaurants (2/05) E R 9,– Address or P.O. Box
Fördergemeinschaft
12 Lighting Quality with Electronics (5/03) E R 9,–
14 Ideen für Gutes Licht zum Wohnen (9/99) R 9,– Gutes Licht
16 Urban image lighting (4/02) E R 9,– City, Postal Code Postfach 70 12 61
Lichtforum free of charge
60591 Frankfurt am Main
Booklets 13 and 15 are out of print
Germany
Place Date Signature/stamp
Please fill in address on back of postcard.
02/05/00/11IV
Fördergemeinschaft Gutes Licht publications
F
ördergemeinschaft Gutes Licht
(FGL) provides information on the
advantages of good lighting and of- Die Beleuchtung
mit künstlichem Licht 1 Gutes Licht für Schulen
und Bildungsstätten 2 Gutes Licht für Sicherheit
auf Straßen, Wegen, Plätzen 3 Gutes Licht für Büros
4
und Verwaltungsgebäude
fers extensive material on every aspect of
artificial lighting and its correct usage. FGL
information is impartial and based on cur-
rent DIN standards and VDE stipulations.
Lichtforum
Lichtforum is a specialist periodical focus-
ing on topical lighting issues and trends. It
is published at irregular intervals.
www.licht.de
FGL is also on the internet. Its website
www.licht.de features a Private Portal and a Repräsentative
Lichtgestaltung 9 Notbeleuchtung
Sicherheitsbeleuchtung 10 Gutes Licht für Hotellerie
und Gastronomie 11 Beleuchtungsqualität
mit Elektronik 12
Pro Portal offering tips on correct lighting for
a variety of domestic, commercial and in-
dustrial “Lighting Applications”. Explana-
tions of technical terms are also available
at the click of a mouse on the buttons
“About Light” and “Lighting Technology”.
Databases containing a wealth of product
data, a product/supplier matrix and the ad-
dresses of FGL members provide a direct
route to manufacturers. “Publications” in an
online shop and “Links” for further infor-
mation round off the broad spectrum of the Gutes Licht für kommunale
Bauten und Anlagen 13 Ideen für Gutes Licht
zum Wohnen 14 Gutes Licht
am Haus und im Garten 15 Stadtmarketing mit Licht 16
FGL light portal.
Booklets 13 and 15
are out of print
Information
on lighting applications
Booklet 11