OVERALL BUILDING SCORE

BUILDING INFORMATION
Dawson Building Type: Mixed Use Score Date: 10/22/2019
1/37 Southern Amberley Rd Gross Floor Area: 2,271 ft2 Building ID #: 19850
Amberley, AK 77077 Year Built: 2010 Software Release: 2019.2.0.1232

Upgrade
Score 10
Estimated
Current
Score 10 Savings1 12%

1 10
Least Ultra-High
Efficient Performance
Buildings Buildings

Building Use Types Estimated Source Energy Use (kBtu/ft2) Energy Use Intensity by Fuel Type

Office: 6,500 ft2 Current Building 82 Site Energy Use (kBtu/ft2)


Warehouse non-refrigerated: 1,000 ft2 Upgraded Building 72
Source Energy Use (kBtu/ft2)
This report includes a Score for the entire
building as well as individual Scores for
each of the separate use types. Fuel Type [ Site EUI , Source EUI ]
Gas [ 2.3, 2.4 ]
Electricity [ 25.5, 79.9 ]
District Hot Water [ 0.0, 0.0 ]
District Steam [ 0.0, 0.0 ]
Propane [ 0.0, 0.0 ]
Fuel Oil [ 0.0, 0.0 ]
District Cooling [ 0.0, 0.0 ]

The Building Energy Asset Score is a national rating system developed by the U.S. Department of Energy. The Score reflects the energy efficiency of a building based
on the building's structure, heating, cooling, ventilation, and hot water systems. The building's Structure and Systems are individually evaluated and ranked. The
Upgrade Opportunities page provides recommendations for how to improve the building's energy efficiency, increase the building's Asset Score, and save money.

1
Savings reflect the reduction in source energy that would result from undertaking all of the user-selected energy efficiency measures
identified on the Upgrade Opportunities page. Actual savings will depend on a variety of factors including actual operating conditions.

This report is based on self-reported building information. http://energy.gov/eere/buildings/building-energy-asset-score


2
SCORE: OFFICE PORTION

Building Name: Dawson Gross Floor Area: 6,500 ft2

Upgrade
Score 10
Estimated
Current
Score 10 Savings1 10%

1 10
Least Ultra-High
Efficient Performance
Buildings Buildings

Standard Occupancy and Operating


Estimated Source Energy Use (kBtu/ft2) Energy Use Intensity by Fuel Type
Conditions

Number of Assumed 32 Current Building 86 Site Energy Use (kBtu/ft2)


Occupants
Upgraded Building 77
Hours of Operation 48.6 Source Energy Use (kBtu/ft2)
hrs/wk
Cooling Set Point 75° F Fuel Type [ Site EUI , Source EUI ]
Heating Set Point 70° F Gas [ 2.6, 2.8 ]
Electricity [ 26.5, 83.2 ]
Misc. Energy Loads 0.75 W/ft2 District Hot Water [ 0.0, 0.0 ]
District Steam [ 0.0, 0.0 ]
Propane [ 0.0, 0.0 ]
Fuel Oil [ 0.0, 0.0 ]
District Cooling [ 0.0, 0.0 ]

1
Savings reflect the reduction in source energy that would result from undertaking all of the user-selected energy efficiency measures
identified on the Upgrade Opportunities page. Actual savings will depend on a variety of factors including actual operating conditions.

This report is based on self-reported building information. http://energy.gov/eere/buildings/building-energy-asset-score


SCORE: WAREHOUSE NON- 3
REFRIGERATED PORTION

Building Name: Dawson Gross Floor Area: 1,000 ft2

Upgrade
Score 10
Estimated
Current
Score 8.5 Savings1 27%

1 10
Least Ultra-High
Efficient Performance
Buildings Buildings

Standard Occupancy and Operating


Estimated Source Energy Use (kBtu/ft2) Energy Use Intensity by Fuel Type
Conditions

Number of Assumed 0 Current Building 59 Site Energy Use (kBtu/ft2)


Occupants
Upgraded Building 43
Hours of Operation 0.0 hrs/wk Source Energy Use (kBtu/ft2)
Cooling Set Point 80° F
Heating Set Point 60° F Fuel Type [ Site EUI , Source EUI ]
Gas [ 0.0, 0.0 ]
Misc. Energy Loads 0.66 W/ft2 Electricity [ 18.7, 58.8 ]
District Hot Water [ 0.0, 0.0 ]
District Steam [ 0.0, 0.0 ]
Propane [ 0.0, 0.0 ]
Fuel Oil [ 0.0, 0.0 ]
District Cooling [ 0.0, 0.0 ]

1
Savings reflect the reduction in source energy that would result from undertaking all of the user-selected energy efficiency measures
identified on the Upgrade Opportunities page. Actual savings will depend on a variety of factors including actual operating conditions.

This report is based on self-reported building information. http://energy.gov/eere/buildings/building-energy-asset-score


4
UPGRADE OPPORTUNITIES

Building Name: Dawson Gross Floor Area: 7,500 ft2

Recommendations for a High Performance Building Energy Savings 3 Cost4

Building Envelope

• Add air barrier to reduce building air leakage.† - Learn More Low $$

• Add insulation to wall Wall 1 in Block 1 and Block 2.† - Learn More Low $$-$$$

• Upgrade the window Window 1 in Block 1 and Block 2.† - Learn More Medium $$-$$$

• Implement a cool roof in Block 1 - Learn More Low $-$$

Lighting Systems

• Replace existing lighting for Fixture 1 to LED lighting in Block 1 and Block 2.† - Learn Medium $
More

• Install occupancy sensors for interior lighting control in Block 1 - Learn More Low $-$$

HVAC Systems and Controls

No opportunities identified.

Service Hot Water Systems

• Add low flow faucets in Block 1 - Learn More Low $$

3
The energy savings range reflects the expected incremental savings for the overall building associated with the specific efficiency
upgrade opportunity assuming all other recommended upgrades have already been implemented. This assumption is made to avoid
double counting of savings. The ranges reflect site energy savings and are based on standard operating assumptions, unless actual
operating conditions are provided by the user.
4
The costs are based on Advanced Energy Retrofit Guide and RS Means. The costs are replacement costs, not incremental costs. The
costs do not include local incentives. Costs are shown as a range ($ = low cost, $$ = medium cost, $$$ = high cost).

User-selected energy efficiency measure
5
STRUCTURES AND SYSTEMS

Building Name: Dawson Gross Floor Area: 7,500 ft2

ABOUT THE BUILDING SYSTEMS ABOUT THE BUILDING ENVELOPE

Ranking5 Ranking5

Interior Lighting Superior Roof U-Value, Non-Attic (Btu/ft2·h·°F) Good


Heating N/A Walls U-Value, Framed (Btu/ft ·h·°F)
2
Good
Cooling Fair Windows U-Value (Btu/ft2·h·°F) Good
Overall HVAC Systems Good Walls + Windows U-Value (Btu/ft2·h·°F) Superior
Window Solar Heat Gain Coefficient Superior

SOURCE ENERGY USE INTENSITY BY END USE


0 10 20 30 40 kBtu/ft2/yr

Interior
Lighting

Heating

Cooling Current Building

With Upgrades

Hot Water Site Energy Use Intensity

5
Ranking Range:
Fair: Building Envelope or Building Systems are less efficient than a typical building built to the AHSRAE 90.1-2004 energy code.
Superior: Building Envelope is more efficient than a typical building built to the AHSRAE 90.1-2013 energy code. Building Systems
exceed the highest efficiency levels with market viable technologies.
Good: Building Envelope or Building Systems are between Fair and Superior.
N/A: The building does not have a heating or a cooling system, or the loads are too low for the system to be effectively ranked.
6
BUILDING ASSETS

Building Name: Dawson Gross Floor Area: 6,500 ft2

Block 1 CHARACTERISTICS SUMMARY


Geometry Current Building

Above Ground: 1 floor


Below Ground: 0 floors Window Layout Discrete
Floor-to-Floor Height 12.00 ft
Floor-to-Ceiling Height: 9.00 ft Number of Windows 2
100′

Orientation: 0.0° from North Window Width 3.0 ft


Use Type: Office
Window Height 3.0 ft

Exterior Shading Type No Shading

Surface 2
65′
Current Building Wall Wall 1

Wall Type Metal panel/Curtain Wall


Roof
Intended Occupancy Type Non-Residential
Roof Roof 1 Window Window 1
Roof Type Metal surfacing Window Framing Type Metal
Intended Occupancy Type Non-Residential Window Glass Type Single Pane

Skylights Window Gas Fill Type None

Intended Occupancy Type Non-Residential


No Skylights
Window SHGC Estimated*

Floor Window VT Estimated*

Window Layout Discrete


Floor Floor 1
Number of Windows 1
Floor Type Steel Joist
Window Width 3.0 ft
Intended Occupancy Type Non-Residential
Window Height 3.0 ft
Walls and Windows Exterior Shading Type No Shading

Surface 1 Surface 3

Wall Wall 1 Wall Wall 1

Wall Type Metal panel/Curtain Wall Wall Type Metal panel/Curtain Wall

Intended Occupancy Type Non-Residential Intended Occupancy Type Non-Residential

Window Window 1 Window Window 1

Window Framing Type Metal Window Framing Type Metal

Window Glass Type Single Pane Window Glass Type Single Pane

Window Gas Fill Type None Window Gas Fill Type None

Intended Occupancy Type Non-Residential Intended Occupancy Type Non-Residential

Window SHGC Estimated* Window SHGC Estimated*

Window VT Estimated* Window VT Estimated*

*
This value was not directly entered by the user. It was generated by the Asset Scoring Tool based on other building data
provided. The user can re-score the building using actual information about this building characteristic if available.
**
Standard operating assumptions are used for building optimization if no values are entered by the user.
7
BUILDING ASSETS

Building Name: Dawson Gross Floor Area: 6,500 ft2

Current Building Current Building

Window Layout Discrete


Heating/Cooling
Number of Windows 1
Thermal Zone Layout Estimated*
Window Width 3.0 ft
Perimeter Zone Depth 15.0 ft
Window Height 3.0 ft
Primary Heating/Cooling System Zone Equipment 1
Exterior Shading Type No Shading
System Type Window Air Conditioners
Surface 4
Cooling Equipment
Wall Wall 1
Cooling Source Terminal DX
Wall Type Metal panel/Curtain Wall
Efficiency Estimated*
Intended Occupancy Type Non-Residential
Heating Equipment
Window Window 1
Heating Source No Heating
Window Framing Type Metal

Window Glass Type Single Pane Service Water Heating


Window Gas Fill Type None Water Heater Natural Gas
Intended Occupancy Type Non-Residential Fuel Type Natural Gas
*
Window SHGC Estimated Water Heater Efficiency 75.00%
Window VT Estimated* Tank Insulation Thickness 2.0 in
Window Layout Discrete Tank Insulation R-value 2.0 °F·ft2·h/Btu
Number of Windows 1
Operations
Window Width 3.0 ft
The information in this section is not required and does not affect the current Asset
Window Height 3.0 ft
Score. If provided, it is only used to identify upgrade opportunities, which are
Exterior Shading Type No Shading considered in generating the potential score.

Operation Using Standard Operations**


Infiltration

Energy code the building complies with Estimated*

Lighting

Lighting Power Density 0.35 W/ft2

Fixture Fixture 1

Lighting Type Fluorescent T5

Mounting Type Surface

Lamp Wattage 40 W/lamp

Lamps per Fixture 2

Number of Fixtures 26

*
This value was not directly entered by the user. It was generated by the Asset Scoring Tool based on other building data
provided. The user can re-score the building using actual information about this building characteristic if available.
**
Standard operating assumptions are used for building optimization if no values are entered by the user.
8
BUILDING ASSETS

Building Name: Dawson Gross Floor Area: 1,000 ft2

Block 2 CHARACTERISTICS SUMMARY


Geometry Current Building

Above Ground: 1 floor


Below Ground: 0 floors Window VT Estimated*
Floor-to-Floor Height 12.00 ft
Floor-to-Ceiling 9.00 ft Window Layout Discrete
50′

Height: Number of Windows 1


Orientation: 0.0° from North
Use Type: Warehouse non- Window Width 3.0 ft
refrigerated
Window Height 3.0 ft

Exterior Shading Type No Shading


20′

Infiltration
Current Building
Energy code the building complies with Estimated*

Roof Lighting
Roof Roof 1 Lighting Power Density 0.88 W/ft2
Roof Type Metal surfacing Fixture Fixture 1
Intended Occupancy Type Non-Residential Lighting Type Fluorescent T5

Skylights Mounting Type Surface

Lamp Wattage 40 W/lamp


No Skylights
Lamps per Fixture 2

Floor Number of Fixtures 10

Floor Floor 1 Heating/Cooling


Floor Type Steel Joist Thermal Zone Layout Estimated*
Intended Occupancy Type Non-Residential Primary Heating/Cooling System Zone Equipment 1

Walls and Windows System Type Window Air Conditioners

Cooling Equipment
All Surfaces
Cooling Source Terminal DX
Wall Wall 1
Efficiency Estimated*
Wall Type Metal panel/Curtain Wall
Heating Equipment
Intended Occupancy Type Non-Residential
Heating Source No Heating
Window Window 1

Window Framing Type Metal Service Water Heating


Window Glass Type Single Pane
No Water Heater
Window Gas Fill Type None

Intended Occupancy Type Non-Residential Operations


Window SHGC Estimated*

*
This value was not directly entered by the user. It was generated by the Asset Scoring Tool based on other building data
provided. The user can re-score the building using actual information about this building characteristic if available.
**
Standard operating assumptions are used for building optimization if no values are entered by the user.
9
BUILDING ASSETS

Building Name: Dawson Gross Floor Area: 1,000 ft2

Current Building

The information in this section is not required and does not affect the current Asset
Score. If provided, it is only used to identify upgrade opportunities, which are
considered in generating the potential score.

Operation Using Standard Operations**

*
This value was not directly entered by the user. It was generated by the Asset Scoring Tool based on other building data
provided. The user can re-score the building using actual information about this building characteristic if available.
**
Standard operating assumptions are used for building optimization if no values are entered by the user.

You might also like