You are on page 1of 2

LMS 07.1 – LMS 16.

Technical data Anti-backdrive device

Type Output Valve attachment Factor1) Flange2) for Input shaft Handwheel Weight4)
torque mounting multi-turn
actuator
Hollow shaft3) with
dog coupling (for
rising valve stem) Shaft journal
Max. Standard Option Valve stem Ø Max. Ø approx.
[Nm] EN ISO 5210 DIN 3210 Max.[mm] [mm] [mm] [mm] [kg]
0.95 200
LMS 07.1 60 F10 G0 F10 40 20 30 9.7
0.95 250
0.95 250
LMS 10.1 120 F14 G1/2 F10 40 20 30 9.7
0.95 315
0.95 315
LMS 14.1 500 F14 G1/2 F14 57 30 40 30
0.95 400
0.95 400
LMS 16.1 1,000 F16 G3 F16 75 40 50 55
0.95 500

Use
Ensuring both static and dynamic self-locking (self-braking) of motor-operated and manually operated valves. Applications subjected to strong loads (like
protective weirs, fishbelly flap gates and sluice gates, etc.) are not permitted.
Exceptions are:
 Applications for which LMS are mounted to worm gearboxes.
 Applications for conventional industrial valves, such as butterfly valves and ball valves.
 Applications with self-locking trapezoidal threads.

Notes on table
1) Factor Corresponds to the efficiency
2) Flange for mounting to multi-turn For the dimensions of the fixing holes, refer to dimension sheet
actuator
3) Hollow shaft Suitable for mounting to multi-turn actuator with output drive type B1 (standard version)
4) Weight Weight includes output drive type B1

Features and functions


Type of duty Standard: Short-time duty S2 - 15 min
Option: Short-time duty S2 - 30 min
The type of duty must not be exceeded.
Input shaft Input shafts made of stainless steel as a standard
Standard: Flange connection for multi-turn actuator with output drive type B1
Option: Input shaft with parallel key according to DIN 6885-1

Operation
Motor operation Directly via multi-turn actuator
Manual operation Directly via handwheel

Valve attachment
Valve attachment A, B1, B3, B4 according to EN 5210
A, B according to DIN 3210

Service conditions
Use Indoor and outdoor use permissible
Mounting position Any position
Ambient temperature Standard: –25 °C to +80 °C
Option: –40 °C to +60 °C
Enclosure protection according to IP68
EN 60529
According to AUMA definition, enclosure protection IP68 meets the following requirements:
 Depth of water: maximum 8 m head of water
 Duration of continuous immersion in water: Max. 96 hours
 Up to 10 operations during continuous immersion
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.440/003/en Issue 1.17 Page 1/2


LMS 07.1 – LMS 16.1

Technical data Anti-backdrive device

Corrosion protection Standard: KN Suitable for installation in industrial units, in water or power plants with a low pollutant
concentration.
Options: KS Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
KX Suitable for use in areas with extremely high salinity, permanent condensation, and high
pollution.
Coating Double layer powder coating
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA anti-backdrive devices meet or exceed the lifetime requirements of EN 15714-2. Detailed information can
be provided on request.

Special features for use in potentially explosive atmospheres


Explosion protection II2G c IIC T4 according to ATEX 94/9/EC
Ambient temperatures Standard: –20 °C to +40 °C
Options: –40 °C to +40 °C
–20 °C to +60 °C
–40 °C to +60 °C
Combinations with SAEx actuators at ambient temperatures > 40 °C with special sizing

Further information
Reference documents Information LMS 07.1 – LMS 16.1
Dimensions LMS 07.1 – LMS 16.1

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.440/003/en Issue 1.17 Page 2/2