Pantalla anterior

Producto: TRACK-TYPE TRACTOR


Modelo: D8T TRACK-TYPE TRACTOR J8B
Configuración: D8T TRACK-TYPE TRACTOR J8B00001-UP (MACHINE) POWERED BY C15 Engine

Localización y Solución de Problemas


AccuGrade® GPS v11 for CD700
Número de medio -KENR8978-00 Fecha de publicación -01/06/2009 Fecha de actualización -08/06/2009

i03489655

Hydraulic System
SMCS - 5051-035

Troubleshooting the Hydraulic System


Problem List (Auto Mode)
• "The AccuGrade System will not engage in the automatic mode and the "Auto Indicator" on
the display does not turn green."

• "Poor Performance"

• "No float function"

Probable Causes (Auto Mode)

The AccuGrade System will not engage in the automatic mode and the "Auto" indicator on
the Display does not turn green.

Note: TheAccuGrade System is programmed to disengage from the "Auto" mode if the machine
implements are not moved in 60 seconds and the machine is in neutral.

1. The pilot valve is in the Lower position.

a. Return the pilot control handle to the Neutral position.

2. The parking brake is on.

a. Disengage the parking brake.

3. Electrical system fault

a. Use Caterpillar Electronic Technician (ET) in order to check for any system faults.

Note: Refer to the "Problem List (Test Valve Mode)" for more information.

b. Check the Caterpillar Monitoring System for any system faults.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 23/09/2010
F T ra n sf o
D8T TRACK-TYPE TRACTOR J8B00001-UP (MACHINE) POWERED BY C15 ... Página 2 de 5 F T ra n sf o
PD rm PD rm
Y Y
Y

Y
er

er
ABB

ABB
y

y
bu

bu
2.0

2.0
to

to
re

re
he

he
k

k
lic

lic
C

C
w om w om
w

w
w.
A B B Y Y.c c. Check the display for any AccuGrade System faults. w.
A B B Y Y.c

ReferenceFor more information, refer to the Troubleshooting, "Determining Detected


Faults (Display)" .

Poor Performance

Note: See "Problem List (Test Valve Mode)" for more problems that can cause poor performance.

1. Improper setting of the valve speed.

ReferenceRefer to Testing and Adjusting, "Blade Reaction Time - Adjust (Valve Speed)"
for more information on this procedure.

2. Improper Calibration

ReferenceRefer to Testing and Adjusting, "Linked Elevation (Dual Mast) - Calibrate" and
Testing and Adjusting, "Bank (Grade Control) - Calibrate" for more information on this
procedure.

3. Improper adjustment of the counterbalance valve

ReferenceRefer to Testing and Adjusting, "Counterbalnce Valve (Grade Control) - Test and
Adjust" for more information on this procedure.

4. The solenoid valve in the counterbalance valve is not functioning.

ReferenceRefer to Testing and Adjusting, "Counterbalnce Valve (Grade Control) - Test and
Adjust" for more information on this procedure.

5. The solenoid in the counterbalance valve has an electrical fault due to an open or a short to
ground in the circuit.

ReferenceRefer to Troubleshooting for more information on procedures for determining an


electrical fault.

6. Operating conditions are not suitable for the AccuGradeSystem.

ReferenceRefer to Operation and Maintenance, SEBU8127, "General Information" for


more information on usage of the AccuGrade System.

7. Hydraulic oil temperature is too low.

a. Warm up the machine's hydraulic oil.

8. The blade on the machine has been changed without recalibration of the counterbalance
valve and the AccuGrade System.

ReferenceRefer to Testing and Adjusting, "Counterbalnce Valve (Grade Control) - Test and
Adjust" for more information on this procedure.

No float function

1. Low pilot pressure.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 23/09/2010
F T ra n sf o
D8T TRACK-TYPE TRACTOR J8B00001-UP (MACHINE) POWERED BY C15 ... Página 3 de 5 F T ra n sf o
PD rm PD rm
Y Y
Y

Y
er

er
ABB

ABB
y

y
bu

bu
2.0

2.0
to

to
re

re
he

he
k

k
lic

lic
C

C
w om w om
w

w
w.
A B B Y Y.c ReferenceRefer to Testing and Adjusting, "Pressure Reducing Valve - Test and Adjust" for w.
A B B Y Y.c

more information on this procedure.

2. The solenoid valve in the counterbalance valve is stuck in the closed position.

Problem List (Test Valve Mode)


• "No blade function in any direction"

• "No function of the blade in a single direction of the blade tilt or no function of the blade in
a single direction of raise/lower"

• "No function of the blade in tilt left and tilt right or no function of the blade in blade raise
and blade lower"

• "The operation of the blade is slow or the operation of the blade is delayed"

• "Movement without operator input"

Probable Causes (Test Valve Mode)


Note: Refer to System Operation, "Menus" for more information about using the test valve mode.

No blade function in any direction

1. The lockout solenoid for the AccuGrade System is closed.

2. Low pilot pressure

ReferenceRefer to Testing and Adjusting, "Pressure Reducing Valve - Test and Adjust" for
more information on this procedure.

3. Electrical system fault

a. Use ET in order to check for any system faults.

Note: Refer to the "Problem List (Test Valve Mode)" for more information.

b. Check the Caterpillar Monitoring System for any system faults.

c. Check the display for the AccuGrade System for any system faults.

ReferenceRefer to the Troubleshooting, "Determining Detected Faults (Display)" for


more information.

No function of the blade in a single direction of the blade tilt or no function of the blade in a
single direction of raise/lower.

1. One of the solenoid valves for the lift, the lower, tilt left, and tilt right are not working.

2. Pilot resolvers or signal resolvers are leaking.

3. Electrical system fault

a. Use ET in order to check for any system faults.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 23/09/2010
F T ra n sf o
D8T TRACK-TYPE TRACTOR J8B00001-UP (MACHINE) POWERED BY C15 ... Página 4 de 5 F T ra n sf o
PD rm PD rm
Y Y
Y

Y
er

er
ABB

ABB
y

y
bu

bu
2.0

2.0
to

to
re

re
he

he
k

k
lic

lic
C

C
w om w om
w

w
w.
A B B Y Y.c Note: Refer to the "Problem List (Test Valve Mode)" for more information. w.
A B B Y Y.c

b. Check the Caterpillar Monitoring System for any system faults.

c. Check the display for the AccuGrade System for any system faults.

ReferenceRefer to the Troubleshooting, "Determining Detected Faults (Display)" for


more information.

No function of the blade in tilt left and tilt right or no function of the blade in blade raise and
blade lower

1. The main valve for the tilt spool is stuck or the main valve for the raise and lower spool is
stuck.

The operation of the blade is slow or the operation of the blade is delayed

Note: The maximum speed of the blade is slower when the AccuGrade System is in the test valve
mode rather than when the AccuGrade System is in manual mode.

1. The valve command from the AccuGrade System is less than 100 percent.

a. Refer to System Operation, "Menus" for more information.

2. Low pilot pressure

ReferenceRefer to Testing and Adjusting, "Pressure Reducing Valve - Test and Adjust" for
more information on this procedure.

3. Pilot resolvers or signal resolvers are leaking or failed.

4. Hydraulic oil temperature is too low.

a. Warm up the machine's hydraulic oil.

5. The pilot valve is not centered.

a. Return the pilot control handle to the Neutral position.

6. Low Hydraulic system flow

a. Check cycle times. Refer to Testing and Adjusting, "Cycle time check" for more
information on this procedure.

7. No or low precharge on the pilot accumulator

a. Check the charge on the nitrogen charged accumulator. Refer to Testing and
Adjusting, "Pressure Reducing Valve - Test and Adjust" for more information on this
procedure.

Movement without operator input

1. The control solenoid valve is failed or stuck in the open position.

a. Determine the bad solenoid valve and replace the bad solenoid.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 23/09/2010
F T ra n sf o
D8T TRACK-TYPE TRACTOR J8B00001-UP (MACHINE) POWERED BY C15 ... Página 5 de 5 F T ra n sf o
PD rm PD rm
Y Y
Y

Y
er

er
ABB

ABB
y

y
bu

bu
2.0

2.0
to

to
re

re
he

he
k

k
lic

lic
C

C
w om w om
w

w
w.
A B B Y Y.c 2. Electrical system fault w.
A B B Y Y.c

a. Use ET in order to check for any system faults.

Note: Refer to the "Problem List (Test Valve Mode)" for more information.

b. Check the Caterpillar Monitoring System for any system faults.

c. Check the display for the AccuGrade System for any system faults.

ReferenceRefer to the Troubleshooting, "Determining Detected Faults (Display)"for


more information.

3. The pilot valve is not centered.

a. Return the pilot control handle to the Neutral position.

Copyright 1993 - 2010 Caterpillar Inc. Thu Sep 23 20:56:29 EST 2010