Design Considerations

 Type of Superstructure: Pre-stressed Concrete 6 girder simply supported span.


 Carriageway specification: Three Lane carriageway of width 11.0 M.
 Type of Substructure: Superstructure is supported on 6 nos. RCC columns .
 Type of foundation: Open foundation
 Skew angle: 57 degree.
 Grade of concrete:
M45 for superstructure,
M35 for all other components

 Grade of un-tensioned reinforcement: Fe 500


 Grade of Prestressing steel: 12T13 low relaxation class 2 strands for 35.375 M span,

12T15 low relaxation class 2 strands for 47.000 M span

 Live Load considered: 3 Lanes of IRC class A train of vehicles, or , 1 Lane of IRC class 70R

train load plus 1 Lane of IRC class A train load, whichever produces

worst effect.

 Crowd Load considered: Basic intensity – 400 kg/m^2


 Codes followed: IRC 6- 2010, IRC 21, IRC 78, IRC 18.