You are on page 1of 2

LOAD TABLE FOR TYPICAL BRACKET TYPE – D/DX

TYPE - D/DX BRACKET TO VESSEL CONNECTION LOAD POINT "A" (LP-A) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm
(Vertical) (Horizontal)
(Horizontal)
315
Max Fx
(DL+FP+CTE+CTO+PR+PCO+ER+ECO- 21.2 0.3 0.7 0.0 0.0 0.0
Case
WL-0.5WTS)
Max Fy 307
9.9 7.6 0.0 0.0 0.0 3.1
Case (DL+FP+CTE+CTO+LL+PR+PCO+ER+E

TYPE - D/DX BRACKET BRACING TO VESSEL CONNECTION LOAD POINT "B" (LP-B) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm

307
Max Fx
(DL+FP+CTE+CTO+LL+PR+PCO+ER+E 17.9 0.0 0.0 0.0 0.0 0.0
Case
CO+TR-AR-GL-FRG-L-FRG-T+IML)

LOAD TABLE FOR TYPICAL BRACKET TYPE – E/EX


TYPE - E BRACKET TO VESSEL CONNECTION LOAD POINT "A" (LP-A) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm
(Vertical) (Horizontal)
(Horizontal)
338
Max Fx
(DL+FP+CTE+CTO+0.75LL+PR+PCO+E 21.2 9.6 1.5 0.0 0.0 0.0
Case
R+ECO+AR+GL+0.75WT+0.38WLS)
Max Fy 202
14.9 10.2 0.0 0.0 0.0 0.0
Case (DL+FP+CTE+CTO+LL+PR+PCT+ER+E

TYPE - E BRACKET BRACING TO VESSEL CONNECTION LOAD POINT "B" (LP-B) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm

306
Max Fx
(DL+FP+CTE+CTO+LL+PR+PCO+ER+E 19.8 0.0 0.0 0.0 0.0 0.0
Case
CO+TR+AR+GL+FRG-L+FRG-T+IML)
LOAD TABLE FOR TYPICAL BRACKET TYPE – F
TYPE - F BRACKET TO VESSEL CONNECTION LOAD POINT "A" (LP-A) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm
(Vertical) (Horizontal)
(Horizontal)
327
Max Fx
(DL+FP+CTE+CTO+PR+PCO+ER+ECO- 106.2 10.9 0.8 0.0 0.0 0.0
Case
AR+GL-WL-0.5WTS)
Max Fy 307
44.0 30.4 0.8 0.0 0.0 0.0
Case (DL+FP+CTE+CTO+LL+PR+PCO+ER+E

TYPE - F BRACKET BRACING TO VESSEL CONNECTION LOAD POINT "B" (LP-B) MEMBER END FORCES
Fx kN
Fy kN Fz kN
LOAD COMBINATION (Axial) Mx kNm My kNm Mz kNm

307
Max Fx
(DL+FP+CTE+CTO+LL+PR+PCO+ER+E 53.7 0.0 0.0 0.0 0.0 0.0
Case
CO+TR-AR-GL-FRG-L-FRG-T+IML)