You are on page 1of 3

ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


RAFTER ID :-Left ( SG-2 ) Refrences
ECP
Steel grade St.37
Fy = 2.40 t/cm2
1)- APPLIED FORCES :- Case Fu = 3.60 t/cm2
M+ive = 18.90 mt a
N1 = 2.45 t
Q1 = 0.00 t
M-ive = 48.56 mt a
N2 = 1.96 t
Q2 = 0.00 t

2)- CHOISE OF SECTION :-


SECTION (1-1) :-
The section is Built Up Section
bFLU = 250.00 mm
tFLU = 12.00 mm
hWeb = 400.00 mm
tWeb = 8.00 mm
bFLL = 250.00 mm
tFLL = 12.00 mm
SECTION (2-2) :-
bFLU = 250.00 mm
tFLU = 12.00 mm
hWeb = 900.00 mm
tWeb = 8.00 mm tWeb(min) = 8.00 mm
bFLL = 250.00 mm
tFLL = 12.00 mm

3)- RAFTER DATA :-


Total length of rafter (Lg) = 25.00 m b
Purlin spacing (S) = 1.56 m tfl
Bracing spacing (S') = 3.13 m b
Web is Unstiffened tfl
tw
h
4)- CHECK SECTIONS :- h tw
A)- Section (1-1) at M+ive :-
PROPERTIES OF SECTION :-
Y = 21.20 cm
A = 92.00 cm2
Ix
Iy
=
=
29735.47
3126.71
cm4
cm4
Sec (1-1) Sec (2-2)
Sx = 1402.62 cm3
rx = 17.98 cm
ry = 5.83 cm

CHECK COMPACTNESS :-
dw/tw = 50.000 Web is Compact table(2.1a)
C/tf = 9.583 Flange is Compact table(2.1c)
The sec is Compact
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


CHECK NORMAL STRESSES :-
fbcx = 1.35 t/cm2 Cb = 1.000 table(2.2)
fca = 0.03 t/cm2
( 20.bf ) / (√ fy ) = 3.227 m ECP 16
Lumax = 3.227 m
( 1380.Af ) / ( fy.d ) x Cb = 4.31 m eqn. 2.18
Lateral torsional buckling of comp.flange There is no LTB
Fltb = 1.536 t/cm2
Fbcx = 1.536 t/cm2
Lbin = 15.00 m
Lbout = 3.13 m
lin = 83.43
lout = 53.60
lmax = 83.43 < 180 SAFE table(4.1)
Fc = 0.95 t/cm2
fca / Fc = 0.03
A1 = 1.00
Applying the interaction equation :
( fca / Fc ) + ( fbcx / Fbcx ) A1 = 0.905 < 1.000 SAFE eqn. 2.35

CHECK SHEAR STRESSES :-


qw = 0.00 t/cm2 < 0.840 SAFE eqn. 2.2

CHECK EQUIVALENT STRESSES :-


fe = 0.00 < 1.10 SAFE eqn. 2.39

B)- Section (2-2) at M-ive :-


PROPERTIES OF SECTION :-
b
Y = 46.20 cm
tfl
A = 132.00 cm2
Ix = 173368.80 cm4
Iy = 3128.84 cm4 stiffener
Sx = 3752.57 cm3 tw
rx = 36.24 cm h
ry = 4.87 cm

Length of haunch = 2.50 m


Lu act.of comp. Flange from sap 2.50 m

CHECK COMPACTNESS :- Sec (2-2)


dw/tw = 112.500 Web is Non compact table(2.1a)
C/tf = 9.583 Flange is Compact table(2.1c)
The sec is Non compact Use stiffener at middle of web no
The sec is Non compact

CHECK STRESSES :-
fbcx = 1.29 t/cm2
fca = 0.01 t/cm2
( 20.bf ) / (√ fy ) = 3.227 m ECP 16
Lumax = 1.917 m
( 1380.Af ) / ( fy.d ) x Cb = 1.92 m eqn. 2.18
Lateral torsional buckling of comp.flange There is LTB
Fltb = 1.392 t/cm2 Use Knee Bracing yes
Fbcx = 1.392 t/cm2
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


Lbin = 16.25 m
Lbout = 3.13 m
lin = 44.84
lout = 64.19
lmax = 64.19 < 180 SAFE table(4.1)
Fc = 1.13 t/cm2
fca / Fc = 0.01
A1 = 1.00
Applying the interaction equation :
( fca / Fc ) + ( fbcx / Fbcx ) A1 = 0.943 < 1.000 SAFE eqn. 2.35