Professional Documents
Culture Documents
Victor Lighting
Victor Lighting
Environments Work
Our
Vision
We aim to be the first
choice supplier of
lighting equipment to
hazardous and industrial
markets worldwide.
1
CONTENTS PAGE 1
INTRODUCTION
LITEGUIDE LIGHTING DESIGN SOFTWARE 4-5
ZONE 1 6-53
ZONE 2 54-71
INDUSTRIAL 72-99
ZONE 1
6-53
ZONE 2
54-71
INDUSTRIAL
72-99
A division of Hubbell Ltd, Victor Lighting is part of the Hubbell Harsh and
Hazardous group and is based in Glasgow, Scotland.
Victor has developed a range of unique technologies that are used to create
innovative lighting solutions. These are installed and relied upon in the most
arduous environments throughout the world.
This hazardous area catalogue features a range of world class light fittings that
are designed in accordance with IEC electrical standards. This product range
will fulfil all lighting requirements in hazardous or industrial environments and in
both onshore, and offshore installations.
The entire Victor Lighting hazardous area range is certified to comply with the
latest ATEX directive. In addition a number of products are certified as part of
the IEC Ex scheme and under Russian (GOST), Thai (TIS) and Chinese (GB)
standards.
LiteGuide™ also includes quantity estimators for interior, exterior and isle lighting
schemes to allow for quick and easy budgeting.
www.victor- lighting.com
28
6 TRIDENT
UNRIVALLED UV PROTECTION
CASSETTEtoRELAMPING
Ingress protection IP66, IP67 SMALL GASKET AREA
IP68 (on application)
Unique lamp cassette design allows for The Trident has the smallest gasket area
GOST-R
quick Approved
and easy lamp replacement, of any Zone 1 fluorescent luminaire,
reducing maintenance costs and irrespective of lamp wattage.
potential exposed lamp breakages.
This design ensures high levels of
ingress protection.
CATEGORY 2 TYPE Ex ‘e’ INCREASED SAFETY 29
7
LAMP-IN-LID TECHNOLOGY
2 x 58W Varient A
B
181
II 2 GD Ex em IIC T4 -45°C to
+50°C*
119
350
Ingress protection to IP66, IP67
IP68 (on application)
2 x 20mm Dia. holes for
GOST-R Approved cable entry, supplied
TIS Approved with 1 Ex e blanking
plug & 1 traveling plug.
GB (China) Approved
*For operation below -20°C Fitting wattage Overall length Dim A Fixing centres Dim B
2x18W 995 400
please contact technical sales
2x36W 1605 700
2x58W 1905 700
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 9
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE CLASSIFICATION
Cable entry devices (ie. glands) must maintain the IP rating for Optional ceiling, wall, pole mounting brackets, and eye
the luminaire. bolts are available on request.
Std. Cat Ref. Wattage Lamp Type Pole mount bracket (38-42mm)
SPOL4-100004
TRIE/218/BI 2x18W Bi-Pin
TRIE/236/BI 2x36W Bi-Pin Pole mount bracket (48-52mm)
TRIE/258/BI 2x58W Bi-Pin SPOL4-100005
M8 eye bolt
SEXCE-00008
Wall bracket
OPTIONS - SUFFIX TO CATALOGUE REF. SEXCE-00009
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
10 TRIDENT VL126
End of Life
Protection
3 Hour
Operation
II 2 GD Ex em IIC T4 -15°C to
+55°C
B
A 181
2 x 58W Varient
119
II 2 GD Ex em IIC T4 -15°C to
+50°C 350
TIS Approved
GB (China) Approved Fixing centres suitable for M8 bolts
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 11
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE CLASSIFICATION
T8, Ø26mm, G13 cap bi-pin fluorescent. Gas environments: T4.
Available in the following configurations: 2 x 18W, Dust environments: T100°C.
2 x 36W, 2 x 58W
AMBIENT TEMPERATURE RANGE
POWER SUPPLY
-15°C to +55°C (18W & 36W versions)
220V-254V, 50/60Hz AC/DC (2 x 18W, 2 x 36W and 2 x 58W)
-15°C to +50°C (58W version)
110V-130V, 50/60Hz AC/DC (2 x 18W and 2 x 36W)
Two x 20mm clearance holes supplied with 1 x transit plug Direct spigot mounting option for up to 42mm diameter is
and 1 x Ex blanking plug. available for the 18W and 36W versions.
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire. ACCESSORIES
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
12 TRIDENT
POLE MOUNT BRACKET SPOL4-100004 (38-42mm dia)
SPOL4-100005 (48-52mm dia)
SPOL4-100006 (58-62mm dia)
A 20
B 10
1
C
POL E DIAMETER
DEPENDANT ON
C
M6 Full Nut
M6 Spring Washer
M6 x 30mm Lg
Hex Head Screw
1
M8 x 20mm Lg
Pan Head Screw
M8 Full Nut
M8 Spring Washer
PART DETAILS
Part I.D. Part Code Part Description A B C
1 SPOL4-100004 POLE MTG 38-42 DIA ASSY 80mm 66mm 26mm
1 SPOL4-100005 POLE MTG 48-52 DIA ASSY 90mm 76mm 32mm
1 SPOL4-100006 POLE MTG 58-62 DIA ASSY 94mm 80mm 38mm
NPRO4-0007
NPRO4-0008/0012
MOUNTING OPTIONS 13
/120
/ 25
/T
/ SC
14 EXCALIBUR VL19E
End of Life
Protection
2 x Ø9.0
GOST-R Approved 94
TIS Approved
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 15
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE CLASSIFICATION
Mono pin - T8, Ø26mm. 18W and 36W ‘cold start’ with Fa6 caps. Gas environments: T4.
Bi-pin - T8, Ø26mm. 18W and 36W with G13 caps. Dust environments: T100°C.
CABLE ENTRIES Standard via two saddle brackets (fixing centres 633mm - 18W
& 1243mm - 36W). Other fixings available upon request.
Two x M20 threaded entries, supplied with 1 x transit plug
and 1 x Ex blanking plug. Optional ceiling, wall, pole mounting brackets, and eye bolts
are also available on request.
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire. The luminaire may be mounted in any orientation.
Std. Cat Ref. Wattage Lamp Type Pole mount bracket (38-42mm)
SPOL4-100004
EXCE/218/BI 2x18W Bi-Pin
EXCE/236/BI 2x36W Bi-Pin
EXCE/218/MO 2x18W Mono-Pin Pole mount bracket (48-52mm)
SPOL4-100005
EXCE/236/MO 2x36W Mono-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
16 EXCALIBUR VL24E
End of Life
Protection
3 Hour
Operation
2 x Ø9.0
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 17
TECHNICAL SPECIFICATION
LAMP TYPES CABLE ENTRIES
Mono pin - T8, Ø26mm. 18W and 36W ‘cold start’ with Fa6 caps. Two x M20 threaded entries supplied with 1 x transit plug
Bi-pin - T8, Ø26mm. 18W and 36W with G13 caps. and 1 x Ex blanking plug.
EMERGENCY OPERATION Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
Typically 3 hours duration for 18W and 36W versions
at 25°C ambient. TEMPERATURE CLASSIFICATION
18W - 35% of one lamp. 36W - 30% of one lamp Gas environments: T4.
Dust environments: T100°C.
BATTERY
AMBIENT TEMPERATURE
12V 4Ah external Ni-Cad
-10°C to +55°C.
POWER SUPPLY
MATERIALS
Standard voltage 220V-254V AC 50/60Hz.
Low voltage 110V-130V AC 50/60Hz. (/120) Control Gear Housing Polycarbonate with silicone rubber
gaskets.
POWER FACTOR Lamp Envelope Polycarbonate end mouldings and
extruded tube.
Better than 0.95. Reflector/Battery Tube Epoxy powder coated stainless steel.
External Fasteners Stainless steel.
TERMINALS
SUSPENSION
4 core up to 4 mm2 conductors with looping.
Through wiring is available as an option. Standard via two saddle brackets (fixing centres 633mm - 18W
Terminals for live constant, live switched, neutral & earth are & 1243mm - 36W). Other fixings available upon request.
provided. Internal earth is on gland entry plate, external earth
terminal is supplied as standard with an M6 brass stud.
Optional ceiling, wall, pole mounting brackets, and eye bolts are
also available on request.
WEIGHT
18W luminaire - 10.5kg. 36W luminaire - 12.0kg. The luminaire may be mounted in any orientation.
Std. Cat Ref. Wattage Lamp Type Pole mount bracket (38-42mm)
SPOL4-100004
EXCE/218/BI/EM 2x18W Bi-Pin
EXCE/236/BI/EM 2x36W Bi-Pin
EXCE/218/MO/EM 2x18W Mono-Pin Pole mount bracket (48-52mm)
SPOL4-100005
EXCE/236/MO/EM 2x36W Mono-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
18 PATHFINDER VL114
3 Hour
Operation
GOST-R Approved
GB (China) Approved M20 Entries View ‘A’
TECHNICAL SPECIFICATION
LAMP TYPES CABLE ENTRIES
11W and 18W compact fluorescent lamps are factory fitted. Two x 20mm clearance holes supplied with 1 x transit plug
and 1 x Ex blanking plug.
POWER SUPPLY
Cable entry devices (ie. glands) must maintain the IP rating for
VL114S 220V-254V, 50/60Hz only (1x11W) the luminaire.
VL114S 110V-254V, 50/60Hz (2x18W)
VL114E 220V-254V, 50/60Hz only (1x11W) TEMPERATURE
POWER FACTOR Gas environments are dependant on gas and ambient temperature
Non-Maintained : T4, T5 & T6. Maintained : T3
Better than 0.95. Dust environments : 100°C
BATTERY MATERIALS
SUSPENSION
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
20 RECESSIBLE TYPE VL77C
End of Life
Protection
GOST-R Approved
Prismatic Diffuser (/PD)
SOLAS B15 Fire rated
TECHNICAL SPECIFICATION
LAMP TYPES AMBIENT TEMPERATURE RANGE
Std. Cat Ref. Wattage Lamp Type There are no accessories for this product
V77E/218/BI 2x18W Bi-Pin
V77E/236/BI 2x36W Bi-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
22 RECESSIBLE TYPE VL78C
End of Life
Protection
90 Min
Operation
3 Hour
Operation
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
Std. Cat Ref. Wattage Lamp Type There are no accessories for this product
V78E/218/BI/EM 2x18W Bi-Pin
V78E/236/BI/EM 2x36W Bi-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
24 M300 PLANK CEILING TYPES
Typical aperture:
DIMENSIONS
18W - 700
36W - 1315
18W - 720
36W - 1335 133
18W - 600
36W - 1215 193
A
235
77
0
.6
17
A (1:8)
Ø9
18W - 820
162 36W - 1435
25 18W - 750
35 36W - 1365
260
235
208
621
275
Dimensions in millimetres
SOLID CEILING TYPES 25
Typical aperture:
DIMENSIONS
18W - 770
36W - 1385
18W - 720
18W - 700 36W - 1335 133
36W - 1315
18W - 600
36W - 1215 193
310
235
94
24
34
60
Min. - 34mm
Swing out arms Max. - 70mm
162
18W - 775
10 36W - 1390
621
260
208
315
Dimensions in millimetres
26 RECESSIBLE VL104C
End of Life
Protection
II 2 GD Ex eqm II T4
GOST-R Approved
TECHNICAL SPECIFICATION
LAMP TYPES AMBIENT TEMPERATURE RANGE
3 x 20mm holes located on the rear panel, two at one end, one SUSPENSION
at the other end. Supplied with 1 x transit plug and 2 x Ex
blanking plugs. Standard mounting is fixed cantilever side brackets, there is also
a provision for drop rod mounting.
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire. For details of appropriate ceiling types and dimensions
see pages 30 and 31.
TEMPERATURE
Std. Cat Ref. Wattage Lamp Type There are no accessories for this product
104E/218/BI* 2x18W Bi-Pin
104E/418/BI 4x18W Bi-Pin
104E/236/BI* 2x36W Bi-Pin
104E/436/BI 4x36W Bi-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
28 RECESSIBLE VL104 Em
End of Life
Protection
90 Min
Operation
3 Hour
Operation
II 2 GD Ex eqm II T4
GOST-R Approved
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE
3 x 20mm holes located on the rear panel, two at one end, one
at the other end. Supplied with 1 x transit plug and 2 x Ex
blanking plugs.
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
Std. Cat Ref. Wattage Lamp Type /MET Modular - Exposed "T" ceiling
104E/218/BI/EM* 2x18W Bi-Pin
/MST Modular - Spring "T" ceiling
104E/418/BI/EM 4x18W Bi-Pin
104E/236/BI/EM* 2x36W Bi-Pin /120 Specific voltage (110/130V)
104E/436/BI/EM 4x36W Bi-Pin
/25 25mm Entries
* Only available in 600mm x 600mm (2 x 18W) and
600mm x 1200mm (2 x 36W) body /LG Low glare louvre
The standard VL104 is supplied with a 3mm clear outer panel /3H 3 hour battery duration (Light output -
and prismatic diffuser.
30% 18W, 25% 36W)
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
30 CEILING TYPE OPTIONS
View of Exposed “T” Ceiling with recessed luminaire, typical 600mm x 600mm tile grid mounting system (/MET).
View of Spring “T” Ceiling with recessed luminaire, typical 600mm x 600mm tile grid mounting system (/MST).
18W - 500
36W - 1100
116
48.5
120.5
35
6
104
44
547
500
18W - 651
164.5 36W - 1261
120.5
18W - 500
36W - 1100
104
4 Holes Ø7.8
18W - 599
36W - 1199 599
4 Holes Ø7.8
18W - 702
36W - 1311
530
18W - 650
500 36W - 1250
109.5 60 NOM
34.5
18W - 470
36W - 1080
72
572
18W - 774
36W - 1374 644
Overall height (including cover) 144mm
Overall height (excluding cover) 138.5mm
Dimensions in millimetres
External earth
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 33
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
VISD/218/BI 2x18W Bi-Pin T8 T6 85 -20°C to +55°C
VISD/136/BI 1x36W Bi-Pin T8 T6 85 -20°C to +53°C
T8 T5 100 -20°C to +55°C
VISD/236/BI 2x36W Bi-Pin T8 T6 85 -20°C to +53°C
T8 T5 100 -20°C to +55°C
VISD/158/BI 1x58W Bi-Pin T8 T6 85 -20°C to +49°C
T8 T5 100 -20°C to +55°C
VISD/258/BI 2x58W Bi-Pin T8 T6 85 -20°C to +49°C
T8 T5 100 -20°C to +55°C
110V-254V, 50/60Hz AC/DC (2 x 18W) /3-4” NPT 3/4 inch NPT cable entry
220V-254V, 50/60Hz AC/DC (2 x 36W and 2 x 58W)
110V-130V, 50/60Hz AC/DC (2 x 36W) /IIC Suitable for IIC gas areas (18W only)
POWER FACTOR
TERMINALS
2
3 core up to 4 mm conductors with looping.
ACCESSORIES
Terminals for live constant, neutral & earth are provided.
Internally earthed, external earth terminal also as standard. Pole mount bracket (38-42mm)
SPOL4-100004
CABLE ENTRIES
Two M20 x 1.5 entries as Standard with an option for two M25 x Pole mount bracket (48-52mm)
1.5 entries. Other cable entries available on request. SPOL4-100005
AMBIENT TEMPERATURE
Wall bracket
Refer to table above. SEXCE-00009
MATERIALS
Wire guard - 18W
Main body LM6 aluminium alloy. SVISD-00008
Lampglass Borosilicate glass overtube.
Reflector Stainless steel.
Wire guard - 36W
WEIGHT SVISD-00009
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
34 VISCOUNT VL52A
End of Life
Protection
3 Hour
Operation
II 2 GD Ex d IIC (18W) A
II 2 GD Ex d IIB (36W & 58W)
External earth
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 35
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
VISD/218/BI/EM 2x18W Bi-Pin T8 T6 85 -20°C to +55°C
VISD/236/BI/EM 2x36W Bi-Pin T8 T6 85 -20°C to +52°C
T8 T5 100 -20°C to +55°C
VISD/258/BI/EM 2x58W Bi-Pin T8 T6 85 -20°C to +48°C
EMERGENCY OPERATION
BATTERY
POWER FACTOR
Two M20 x 1.5 entries as Standard with an option for two M25 x
Pole mount bracket (58-62mm)
1.5 entries. Other cable entries available on request.
SPOL4-100006
Supplied with 1 x transit plug and 1 x Ex blanking plug.
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
Ceiling mount bracket assembly
SEXCE-00001
AMBIENT TEMPERATURE
WEIGHT
Wire guard - 36W
2 x 18W Lamps - 9Kg SVISD-00009
2 x 36W Lamps - 16Kg
2 x 58W Lamps - 18Kg
Wire guard - 58W
SVISD-00010
SUSPENSION
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
36 VISCOUNT 8W
End of Life
Protection
3 Hour
Operation
II 2 GD Ex d IIB
External earth
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 37
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
VISD/108/BI 1x8W Bi-Pin T5 T6 85 -20°C to +55°C
VISD/208/BI 2x8W Bi-Pin T5 T6 85 -20°C to +55°C
VISD/108/BI/EM* 1x8W Bi-Pin T5 T6 85 -20°C to +55°C
* Maintained as standard
Two M20 x 1.5 entries as Standard with an option for two M25 x Wall bracket
1.5 entries. Other cable entries available on request. SEXCE-00009
Supplied with 1 x transit plug and 1 x Ex blanking plug.
Cable entry devices (ie. glands) must maintain the IP rating for Wire guard
the luminaire.
SVISD-00007
TEMPERATURE
Exit sign chain hanging (no direction)
Gas environments: T6. SPATE-00005
Dust environments: T85°C
Exit sign chain hanging (up arrow)
AMBIENT TEMPERATURE SPATE-00006
-20°C to +55°C
Exit sign chain hanging (down arrow)
MATERIALS SPATE-00007
Main body LM6 aluminium alloy. Exit sign chain hanging (right arrow)
Lampglass Borosilicate glass overtube. SPATE-00008
Reflector Stainless steel.
Exit sign chain hanging (left arrow)
WEIGHT
SPATE-00009
1 x 8W Lamp - 5kg
2 x 8W Lamp - 5kg Exit sign, rigid plastic, chain hanging (double
1 x 8W Lamp Emergency- 5.5kg sided arrow left & arrow right)
SPATE-00011
SUSPENSION
Exit sign, adhesive (up, down, left and right)
Standard support channel supplied will accept Ø 12mm
fasteners with variable fixing points and compatible with SPATE-00012
existing cable support systems.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
38 VANGUARD VL34 HELI-DECK
90 Min
Operation
Ex e mb IIC T4 Gb
64 CRS
206
Ex tb IIC T100°C Db
Emergency:
II 2 GD
Ex e ib mb IIC T4 Gb 4 fixing holes
Ex tb IIC T100°C Db Ø10.3
13
292 B-B
Meets current CAA (CAP 437)
and ICAO guidelines for
helicopter landing area lighting
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 39
ORDERING REFERENCE
POWER SUPPLY
TERMINALS
2
3 core up to 4 mm conductors with looping.
CABLE ENTRIES
3 x M20 entries, two at one end & one at the other end.
MATERIALS
Main body LM6 die cast aluminium, with epoxy paint finish.
Lampglass Clear borosilicate (diffused pattern).
Gaskets Silicone.
Wire guard 10 SWG zinc plated wire epoxy powder coated.
External fastners Stainless steel.
WEIGHT
SUSPENSION
EMERGENCY OPERATION
BATTERY
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
40 VANGUARD VL35 LED
90 Min
Operation
B
Non Emergency: Entries
II 2 GD B
152.5 CRS
Ex e mb IIC T4 Gb
206
Ex tb IIC T100°C Db
64 CRS
Emergency:
II 2 GD
Ex e ib mb IIC T4 Gb 4 fixing holes
Ex tb IIC T100°C Db Ø10.3
186
48
24
B-B
292
Dimensions in millimetres
ZONE 1 TYPE Ex ‘e’ INCREASED SAFETY 41
ORDERING REFERENCE
CABLE ENTRIES
3 x M20 entries, two at one end & one at the other end.
MATERIALS
Main body LM6 die cast aluminium, with epoxy paint finish.
Lampglass Clear borosilicate (diffused pattern).
Gaskets Silicone.
Wire guard 10 SWG zinc plated wire epoxy powder coated.
External fastners Stainless steel.
WEIGHT
SUSPENSION
EMERGENCY OPERATION
BATTERY
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
42 TITAN VL38
303
275 CRS
292
ATEX Certificate SIRA01ATEX1049 100 1 Hole Ø13
2 Holes Ø9
II 2 GD Ex de II C T4*
GOST-R Approved
276
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 43
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
TI8D/050/HS 50W HPS E27 T4 110 (-50°C**) -20°C to +60°C
TI8D/050/MV 50W Mercury Vapour E27 T4 120 -20°C to +60°C
TI8D/070/MS 70W HPS & Metal Halide E27 T4 110 (-50°C**) -20°C to +60°C
TI8D/080/MV 80W Mercury Vapour E27 T4 120 -20°C to +60°C
TI8D/125/MV 125W Mercury Vapour E27 T4 123 -20°C to +48°C
TI8D/100/GL 100W GLS E27 T4 108 (-50°C**) -20°C to +68°C
TI8D/200/GL 200W GLS E27 T4 115 (-50°C**) -20°C to +55°C
TI8D/113/CF 1x10/13W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/118/CF 1x18W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/126/CF 1x26W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/213/CF 2x10/13W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/218/CF 2x18W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/226/CF 2x26W Compact Fluorescent G24q T4 85 -20°C to +60°C
TI8D/055/QL 55W QL QL T4 93 -50°C to +63°C
TI8D/085/QL 85W QL QL T4 97 -50°C to +57°C
TECHNICAL SPECIFICATION
LAMP TYPES SUSPENSION
SON - 50W & 70W Mounting supplied with luminaire is for pendant operation
MBF - 50W, 80W & 125W suitable for two Ø 10mm fasteners on 275mm centres.
Optional stirrup mounting available for wall/directional
GLS - 200W Max (E27)
applications.
Compact Fluorescent - Single & Twin 10/13W, 18W & 26W
Philips QL - 55W & 85W
Better than 0.85 for High Intensity Discharge Luminaire /LT Low temperature version (-50°C)
Better than 0.95 for QL & Compact Fluorescent Luminaire
*** T rating and ambient may vary for universal (stirrup) mounting.
Please contact technical sales.
TERMINALS
WEIGHT
HID & QL Luminaire 10.0 kg
GLS & Compact Fluorescent 7.5 kg Pole clamp
STI8D-00005
(For use with 40-60mm dia. pole)
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
44 TITAN VL39
410
370 CRS
1 Hole Ø21
100 100
ATEX Certificate SIRA01ATEX1274 2 Holes Ø13
II 2 GD Ex de II C T4*
GOST-R Approved
TIS Approved
490
344
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 45
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
TI9D/150/MS 150W HPS & Metal Halide E40 T3 145 -20°C to +50°C**
T4 125 -20°C to +35°C**
TI9D/250/MS 250W HPS & Metal Halide E40 T3 145 -20°C to +50°C**
T4 125 -20°C to +35°C**
TI9D/400/MS 400W HPS & Metal Halide E40 T3 170 -20°C to +40°C**
T4 130 -20°C to +40°C**
TI9D/250/MV 250W Mercury Vapour E40 T3 145 -20°C to +50°C**
T4 125 -20°C to +35°C**
TI9D/400/MV 400W Mercury Vapour E40 T3 170 -20°C to +40°C**
T4 130 -20°C to +40°C**
TI9D/500/GL 500W GLS E40 T3 170 -20°C to +35°C**
T4 130 -20°C to +30°C**
TI9D/165/QL 165W QL QL T4 105 -20°C to +55°C**
TECHNICAL SPECIFICATION
LAMP TYPES SUSPENSION
SON - 150W, 250W & 400W Mounting supplied with luminaire is for pendant operation
MBI - 150W, 250W & 400W suitable for two M12 fasteners on 370mm centres.
MBF - 150W, 250W & 400W Optional stirrup mounting available for wall/directional
GLS - 500W Max applications.
Philips QL - 165W (not suitable for reflector lamps).
POWER SUPPLY
OPTIONS - SUFFIX TO CATALOGUE REF.
SON, MBI & MBF 220V, 230V, 240V & 250V, 50Hz or 60Hz
GLS 250V Max /60 60Hz
QL Lamps 200V - 240V 50/60Hz AC/DC (standard)
110V - 130V 50/60Hz AC/DC (optional) /M25 M25 Entries
/S Stirrup version for universal mounting***
POWER FACTOR
/SLC Sealed lamp chamber - Maintenance free
(QL version)
Better than 0.95 for QL, GLS
Better than 0.85 for High Intensity Discharge Luminaire. /120 120V - QL lamps only
CABLE ENTRIES
ACCESSORIES
Two M20 x 1.5 entries as Standard with an option for two M25 x
1.5 entries. Other cable entries available on request.
Stirrup mount bracket
Supplied with 1 x transit plug and 1 x Ex blanking plug. STI9D-00001
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
Wire guard
STI9D-00002
MATERIALS
HID 23.0 kg
QL Luminaire 20.0 kg Pole clamp
GLS 19.0 kg STI9D-00005
(For use with 70-80mm dia. pole)
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
46 TITAN II VL147
II 2 GD Ex de II C T4*
Ø13
Ambient temperature range:
-50°C to +70°C* Standard Configuration
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 47
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
TI7D/050/HS 50W HPS E27 T4 120 -50°C to +70°C
TI7D/050/MV 50W Mercury Vapour E27 T4 120 -20°C to +70°C
TI7D/070/HS 70W HPS E27 T4 120 -50°C to +70°C
TI7D/070/MH 70W Metal Halide E27 T4 120 -50°C to +70°C
TI7D/080/MV 80W Mercury Vapour E27 T4 128 -20°C to +68°C
TI7D/125/MV 125W Mercury Vapour E27 T4 130 -20°C to +50°C
TI7D/150/HS 150W HPS E27 T3 122 -50°C to +47°C
E27 T4 100 -50°C to +25°C
TI7D/200/GL 200W GLS E27 T4 130 -50°C to +65°C
TECHNICAL SPECIFICATION
LAMP TYPES WEIGHT
Terminals for live, neutral & earth are provided. /60 60Hz
Cable entry devices (ie. glands) must maintain the IP rating for There are no accessories for this product.
the luminaire.
MATERIALS
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
28
48 VL64 EQUAL PLUS
Stainless steel aiming quadrant for Large surface area of cover glass ensures a
accurate and consistent floodlight high light output ratio (LOR) and optimum
positioning. photometric performance.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
50 VL64 EQUAL PLUS
490
II 2 GD Ex de IIB T*
300 370
GOST-R Approved (2 holes 13mm Dia.)
TIS Approved
2xM20 Entries
Exe Terminal
box
Aiming quadrant
for stirrup
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 51
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
64ED/150/MS 150W HPS & Metal Halide E40 T4 128 -20°C to +70°C
T3 145 -20°C to +70°C
64ED/250/MS 250W HPS & Metal Halide E40
T4 175 -20°C to +55°C
64ED/400/MS 400W HPS & Metal Halide E40 T3 160 -20°C to +55°C
64ED/500/TH 500W Tungsten Halogen E40 T3 175 -20°C to +55°C
POWER FACTOR
TERMINALS
MATERIALS
Wire guard (cannot be used with
Main Body LM6 aluminium with epoxy paint finish anti-glare shield)
as standard. S6428-0003
Lampglass Toughened soda lime glass plate.
External fasteners Stainless steel.
Combined Anti-glare shield
WEIGHT and wire guard
S6428-0004
Discharge lamp versions - 31.0Kg.
Tungsten halogen lamp versions - 26.0Kg
SUSPENSION
BEAM PATTERNS
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
52 FLOODLIGHT VL65
387 206
II 2 GD Ex de IIB T3
315
267
GOST-R Approved
Dimensions in millimetres
ZONE 1 TYPE Ex ‘d’ FLAMEPROOF 53
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
V65D/050/HS 50W HPS E27 T3 200 -50°C to +55°C
V65D/050/MV 50W Mercury Vapour E27 T3 200 -50°C to +55°C
V65D/070/MS 70W HPS/Metal Halide E27 T3 200 -50°C to +55°C
V65D/080/MV 80W Mercury Vapour E27 T3 200 -50°C to +55°C
V65D/125/MV 125W Mercury Vapour E27 T3 200 -50°C to +55°C
V65D/250/TH 250W Tungsten Halogen E27 T3 200 -50°C to +30°C
POWER FACTOR
TERMINALS
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
MATERIALS
WEIGHT
MOUNTINGS
BEAM PATTERNS
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
54 MARQUIS II VL53
End of Life
Protection
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
IECEx Certificate IECEx SIR 06.0055X end.
TECHNICAL SPECIFICATION
LAMP TYPES TEMPERATURE CLASSIFICATION
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire. SUSPENSION
Std. Cat Ref. Wattage Lamp Type Pole mount bracket (38-42mm)
SPOL4-100004
MA2N/218/BI 2x18W Bi-Pin
MA2N/136/BI 1x36W Bi-Pin
Pole mount bracket (48-52mm)
MA2N/236/BI 2x36W Bi-Pin SPOL4-100005
MA2N/158/BI 1x58W Bi-Pin
Pole mount bracket (58-62mm)
MA2N/258/BI 2x58W Bi-Pin
SPOL4-100006
A stainless steel body version is also available. Offset ceiling bracket assembly
To order substitute MA2N with MS2N.
S3004-100001
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
56 MARQUIS II VL54
End of Life
Protection
3 Hour
Operation
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
IECEx Certificate IECEx SIR 06.0055X end.
TECHNICAL SPECIFICATION
LAMP TYPES TERMINALS
2
T8, Ø26mm, G13 cap bi-pin fluorescent. 4 core up to 4 mm conductors. Through wiring facility as
Available in the following configurations: 2 x 18W, standard. Terminals for live constant, live switched neutral &
2 x 36W, 2 x 58W. earth are provided. Internal earth.
BATTERY WEIGHT
Std. Cat Ref. Wattage Lamp Type Pole mount bracket (38-42mm)
SPOL4-100004
MA2N/218/BI/EM 2x18W Bi-Pin
MA2N/136/BI/EM 2x36W Bi-Pin
Pole mount bracket (48-52mm)
MA2N/236/BI/EM 2x36W Bi-Pin SPOL4-100005
MA2N/158/BI/EM 1x58W Bi-Pin
Pole mount bracket (58-62mm)
MA2N/258/BI/EM 2x58W Bi-Pin
SPOL4-100006
A stainless steel body version is also available. Offset ceiling bracket assembly
To order substitute MA2N with MS2N.
S3004-100001
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
58 MONARCH VL14
II 3 G Ex nR II T4 T135°C
& T5 T100°C
-20°C to +50°C*
178
GOST-R Approved
Ø385
Dimensions in millimetres
ZONE 2 TYPE Ex ‘n’ RESTRICTED BREATHING 59
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
MONN/070/HS 70W HPS E27 T5 100 -20°C to +50°C
MONN/080/MV 80W Mercury Vapour E27 T5 100 -20°C to +40°C
MONN/100/GL 100W GLS E27 T4 135 -20°C to +45°C
MONN/125/MV 125W Mercury Vapour E27 T4 135 -20°C to +35°C
MONN/160/MB 160W MBTF E27 T4 135 -20°C to +40°C
MONN/200/GL 200W GLS E27 T4 135 -20°C to +40°C
TECHNICAL SPECIFICATION
LAMP TYPES WEIGHT
2
3 core up to 2.5 mm conductors with looping. Through wiring
facility as standard. Terminals for live, neutral & earth are
provided. External earth is an option.
CABLE ENTRIES
AMBIENT TEMPERATURE
MATERIALS Reflector
SMONN-00002
Main Body LM6 aluminium - with epoxy paint finish.
Lamp glass Borosilicate glass.
(prismatic pattern).
External fasteners Stainless steel.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
28
60 MONARCH II
1
Once
Ingressthe base is secure,
protection hang the main
to IP66, IP67 The main body can now be swung into
bodyIP68
via(on
theapplication)
hook on the base. This will place and secured using a screwdriver
remain suspended leaving your hands or nut driver. The terminal chamber
freeGOST-R Approved
to complete the connections is now sealed.
to the terminal block.
ZONE 2 Ex ‘n’ PENDANT LUMINAIRE 29
61
4 5
Now safely screw the appropriate Finally attach the unique threaded
lamp into the body. lamp glass and turn until a secure
seal is achieved.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
62 MONARCH II VL15
327
M8 mounting
II 3 GD Ex nA nR II
447
Ceiling mounted
Ambient temperature range:
-45°C to +55°C*
TIS Approved
460 Dia.
Enclosed reflector model
Dimensions in millimetres
ZONE 2 TYPE Ex ‘n’ RESTRICTED BREATHING 63
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
MO2N/050/HS 50W HPS E27 T4 110 -45°C to +55°C
MO2N/070/HS 70W HPS E27 T4 110 -45°C to +55°C
MO2N/100/MS 100W HPS/Metal Halide E40 T4 110 -45°C to +55°C
MO2N/150/MS 150W HPS/Metal Halide E40 T4 110 -45°C to +55°C
MO2N/250/MS 250W HPS/Metal Halide E40 T4 130 -45°C to +50°C
MO2N/400/MS 400W HPS/Metal Halide E40 T3 160 -45°C to +45°C
MO2N/080/MV 80W Mercury Vapour E27 T3 135 -45°C to +45°C
MO2N/125/MV 125W Mercury Vapour E27 T3 135 -45°C to +45°C
MO2N/250/MV 250W Mercury Vapour E40 T3 135 -45°C to +40°C
MO2N/400/MV 400W Mercury Vapour E40 T3 180 -45°C to +35°C
220, 230, 240V 50Hz (50, 80, 100 & 125W) /ST Stanchion mounted version
220, 230, 240, 254V 50Hz (70, 150, 250 & 400W)
/PE Pendant mounted version
TERMINALS (single M25 entry from top)
3 core up to 6 mm2 conductors with looping. Terminals for live /TI Timed cut out ignitor
constant, neutral & earth are provided. External earth terminal as
an option. /ER Enclosed spun reflector
CABLE ENTRIES
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
ACCESSORIES
TEMPERATURE
Refer to matrix above for maximum ambient temperature for Wire guard for low wattage glass globe
lamp, T rating & orientation. (up to 150W)
E0850-0042
MATERIALS
Main body and base Painted alluminium alloy. Wire guard for high wattage glass globe
Lamp glass Borosilicate glass. (200W/400W)
Gasket Silicone rubber. E0850-0044
WEIGHT
Wire guard for enclosed reflector
HPS - 7.5Kg (50W), 9.0Kg (100W) E0850-0043
HPS/Metal Halide - 8.0Kg (70W), 11.0Kg (150W),
15.0kg (250W), 15.5Kg (400W)
Mercury Vapour - 7.5Kg (80W), 8.0Kg (125W), 15.0Kg (250W),
15.5Kg (400W) Dome reflector
HEC20-0001
SUSPENSION
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
64 MONARCH II
CEILING and FLUSH MOUNTING
353
327
345
WALL MOUNTING (/WM)
146
430
279
146
127
73
36
353
327
345
164
458
294
460
428
374
66 VANGUARD VL20
B
48
206
II 3 G Ex nR II T4
254 CRS
Ingress protection to IP66 and IP67
292
GOST-R Approved
48
Dimensions in millimetres
ZONE 2 TYPE Ex ‘n’ RESTRICTED BREATHING 67
ORDERING REFERENCE
POWER SUPPLY
POWER FACTOR
TERMINALS
2
3 core up to 4 mm conductors with looping. Through wiring
facility as standard. Terminals for live constant, neutral & earth
are provided. External earth terminal as an option.
CABLE ENTRIES
MATERIALS
Main Body LM6 die cast aluminium, with epoxy paint finish.
Lampglass Borosilicate (diffused pattern).
Gasket Silicone.
External Fasteners Stainless steel.
WEIGHT
SUSPENSION
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
68 REGENT VL71
465 105
80 24.5
250
II 3 GD Ex nA nR II
280
-50°C to +60°C*
5 holes Ø13mm
56 56
150 150
Dimensions in millimetres
ZONE 2 TYPE Ex ‘n’ RESTRICTED BREATHING 69
ORDERING REFERENCE
POWER FACTOR
TERMINALS
2
3 core up to 6 mm conductors with looping. Terminals for live
constant, neutral & earth are provided. Internally earthed,
external earth terminal as standard.
CABLE ENTRIES
Main Body Epoxy painted marine grade stainless Spigot mount bracket
steel. S2400-0007
Lampglass Toughened glass.
Gasket Silicone rubber.
External Fasteners Stainless steel. Anti-glare shield
S8644-0002
WEIGHT (Requires /WA suffix when ordering)
150W - 19Kg
250W - 20.5Kg
400W - 21Kg
500W - 16.5Kg
110/120V - 23Kg
MOUNTING
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
70 FLOODLIGHT VL100
II 3 GD Ex nR II T3 T200°C
464.5
-50°C to +50°C
Gear chamber
anti-vibration
TIS Approved washer.
138.2
102.5
125 125
45
141.1 404
187.5
3 mounting holes:
centre hole Ø21mm
outer holes Ø14mm
Dimensions in millimetres
ZONE 2 TYPE Ex ‘n’ RESTRICTED BREATHING 71
ORDERING REFERENCE
Std. Cat Ref. Wattage Lamp Type Lampholder T Class T °C(Dust) Ambient °C
V10N/150/MS 150W HPS/Metal Halide E40 T3 200 -50°C to +50°C
V10N/250/MS 250W HPS/Metal Halide E40 T3 200 -50°C to +50°C
V10N/250/MV 250W Mercury Vapour E40 T3 200 -50°C to +50°C
V10N/400/MS 400W HPS/Metal Halide E40 T3 200 -50°C to +50°C
V10N/400/MV 400W Mercury Vapour E40 T3 200 -50°C to +50°C
V10N/500/TH 500W Tungsten Halogen E40 T3 200 -50°C to +50°C
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
3 core up to 4 mm2 conductors with looping. Terminals for live /60 60Hz
constant, neutral & earth are provided. Internally earthed.
/M Medium beam reflector
CABLE ENTRIES
TEMPERATURE
Gas environments: T3
Dust environments: T200°C
ACCESSORIES
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
72 MARQUIS II VL55 I
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
Ingress protection IP65 end.
to EN60529 A
Designed & manufactured C
to EN60598-1
Stainless Steel Body
D
B
3x20mm Dia.
cable entry
clearance
holes.
A
2x1 end
1x opposite.
C GRP Body
1 x 18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 702 1312 1612
B 500 800 1100
C 102 / 172 102 / 172 102 / 172
D 106 106 106
Stainless Steel Body
1x18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 700 1312 1612
B 500 800 1100
C 172 172 172
Dimensions in millimetres D 106 106 106
INDUSTRIAL AREA FLUORESCENT LUMINAIRE 73
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
T8, Ø26mm, G13 cap bi-pin fluorescent. Body Corrosion resistant glass reinforced
Available in the following configurations: 2 x 18W, polyester (GRP) or stainless steel.
2 x 36W, 2 x 58W. Diffusers Polycarbonate.
Clips Stainless Steel (18Wx6, 36Wx8 & 58Wx10).
POWER SUPPLY Gear Tray White polyester painted zinc
coated steel.
230V/240V 50Hz
CONTROL GEAR
POWER FACTOR
Copper & Iron pulse start ballast.
Greater than 0.80
WEIGHT
TERMINALS
GRP Body Stainless Body
4 core up to 4 mm2 conductors. Through wiring is available as an 1 x 18W Lamp - 2.5Kg 1 x 18W Lamp - 5.5Kg
option. Terminals for live constant, live switched, neutral & earth 1 x 36W Lamp - 3.6Kg 1 x 36W Lamp - 6.6Kg
are provided. Internally earthed. 1 x 58W Lamp - 4.2Kg 1 x 58W Lamp - 7.2Kg
2 x 18W Lamps - 3.2Kg 2 x 18W Lamps - 6.2Kg
CABLE ENTRIES 2 x 36W Lamps - 4.2Kg 2 x 36W Lamps - 7.2Kg
2 x 58W Lamps - 5.1Kg 2 x 58W Lamps - 8.1Kg
Pre-drilled Ø20mm.
SUSPENSION
Supplied with 1 x transit plug and the required number of
blanking plugs. 8mm clearance holes, sealing washers are provided.
Cable entry devices (ie. glands) must maintain the IP rating for A range of mounting accessories are available. See below:
the luminaire.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
74 MARQUIS II VL55 I H/F
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
Ingress protection IP65 end.
to EN60529 A
Designed & manufactured C
to EN60598-1
Stainless Steel Body
D
B
3x20mm Dia.
cable entry
clearance
holes.
A
2x1 end
1x opposite.
C GRP Body
1 x 18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 702 1312 1612
B 500 800 1100
C 102 / 172 102 / 172 102 / 172
D 106 106 106
Stainless Steel Body
1x18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 700 1312 1612
B 500 800 1100
C 172 172 172
Dimensions in millimetres D 106 106 106
INDUSTRIAL AREA FLUORESCENT LUMINAIRE 75
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
T8, Ø26mm, G13 cap bi-pin fluorescent. Body Corrosion resistant glass reinforced
Available in the following configurations: 2 x 18W, polyester (GRP) or stainless steel.
2 x 36W, 2 x 58W. Diffusers Polycarbonate.
Clips Stainless Steel (18Wx6, 36Wx8 & 58Wx10).
POWER SUPPLY Gear Tray White polyester painted zinc
coated steel.
120V-254V, 50/60Hz AC
175V-270V DC CONTROL GEAR
Supplied with 1 x transit plug and the required number of 8mm clearance holes, sealing washers are provided.
blanking plugs.
A range of mounting accessories are available. See below:
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
76 MARQUIS II VL56 I
3 Hour
Operation
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
Ingress protection IP65 end.
to EN60529 A
Designed & manufactured C
to EN60598-1
Stainless Steel Body
D
B
3x20mm Dia.
cable entry
clearance
holes.
A
2x1 end
1x opposite.
C GRP Body
1 x 18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 702 1312 1612
B 500 800 1100
C 102 / 172 102 / 172 102 / 172
D 106 106 106
Stainless Steel Body
1x18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 700 1312 1612
B 500 800 1100
C 172 172 172
Dimensions in millimetres D 106 106 106
INDUSTRIAL AREA FLUORESCENT LUMINAIRE 77
TECHNICAL SPECIFICATION
LAMP TYPES TERMINALS
T8, Ø26mm, G13 cap bi-pin fluorescent. 4 core up to 4 mm2 conductors. Through wiring is available as an
Available in the following configurations: 2 x 18W, option. Terminals for live constant, live switched, neutral & earth
2 x 36W, 2 x 58W. are provided. Internally earthed.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
78 MARQUIS II VL56 I H/F
3 Hour
Operation
D
B
2x20mm Dia.
cable entry
clearance
holes 1 each
Ingress protection IP65 end.
to EN60529 A
Designed & manufactured C
to EN60598-1
Stainless Steel Body
D
B
3x20mm Dia.
cable entry
clearance
holes.
A
2x1 end
1x opposite.
C GRP Body
1 x 18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 702 1312 1612
B 500 800 1100
C 102 / 172 102 / 172 102 / 172
D 106 106 106
Stainless Steel Body
1x18W / 2x18W 1x36W / 2x36W 1x58W / 2x58W
A 700 1312 1612
B 500 800 1100
C 172 172 172
Dimensions in millimetres D 106 106 106
INDUSTRIAL AREA FLUORESCENT LUMINAIRE 79
TECHNICAL SPECIFICATION
LAMP TYPES TERMINALS
T8, Ø26mm, G13 cap bi-pin fluorescent. 4 core up to 4 mm2 conductors. Through wiring is available as an
Available in the following configurations: 2 x 18W, option. Terminals for live constant, live switched, neutral & earth
2 x 36W, 2 x 58W. are provided. Internally earthed.
220-254V, 50/60Hz AC (other voltages available) Body Corrosion resistant glass reinforced
120V 50/60Hz AC (option available) polyester (GRP) or stainless steel.
Diffusers Polycarbonate.
POWER FACTOR Clips Stainless Steel (18Wx6, 36Wx8 & 58Wx10).
Gear Tray White polyester painted zinc
Greater than 0.95 coated steel.
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
80 RECESSIBLE VL77 I
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
18W & 36W bi-pin fluorescent (T8) Enclosure White polyester painted zinc coated
steel body & frame.
POWER SUPPLY Diffuser Clear polycarbonate.
Reflector White polyester painted zinc
120-254V 50/60Hz AC, 175-270V DC coated steel.
Gasket Neoprene rubber.
TERMINALS
WEIGHT
3 core up to 4 mm2 conductors with looping. Through wiring
facility as standard. Terminals for live constant, neutral & earth 2 x 18W - 6Kg.
are provided. External earth terminal as standard. 2 x 36W - 11Kg.
4 x 20mm entries, two at each end (not suitable for looping both Standard mounting is fixed side brackets with swing out arms,
ends). with provision for drop rod mounting.
Supplied with 1 x transit plug and 3 x blanking plugs. For details of appropriate ceiling types and dimensions see
pages 84 and 85.
Cable entry devices (i.e. glands) must maintain the IP rating
for the luminaire.
Std. Cat Ref. Wattage Lamp Type There are no accessories for this product.
V77I/218/BI 2x18W Bi-Pin
V77I/236/BI 2x36W Bi-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
82 RECESSIBLE VL78 I
3 Hour
Operation
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
18W & 36W bi-pin fluorescent (T8) Enclosure White polyester painted zinc coated
steel body & frame.
POWER SUPPLY Diffuser Clear polycarbonate.
Reflector White polyester painted zinc
220-254V 50/60Hz AC, 120V 50/60Hz AC coated steel.
Gasket Neoprene rubber.
EMERGENCY OPERATION
WEIGHT
Typically 3 hours duration at 25°C
22% of one lamp (18W) 2 x 18W - 8.5Kg.
14% of one lamp (36W) 2 x 36W - 13.5Kg.
BATTERY SUSPENSION
6V, 4Ah internal Ni-Cad. Standard mounting is fixed side brackets with swing out arms,
with provision for drop rod mounting.
TERMINALS
Suitable for Danaccoustic m300 planks or damper cc300 planks.
4 core up to 4 mm2 conductors with looping. Through wiring
facility as standard. Terminals for live constant, live switched, For details of appropriate ceiling types and dimensions see
neutral & earth are provided. External earth terminal as standard. pages 84 and 85.
CABLE ENTRIES
Std. Cat Ref. Wattage Lamp Type There are no accessories for this product.
V78I/218/BI/EM 2x18W Bi-Pin
V78I/236/BI/EM 2x36W Bi-Pin
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
84 M300 PLANK CEILING TYPES
Typical aperture:
DIMENSIONS
18W - 700
36W - 1315
18W - 720
36W - 1335 133
18W - 600
36W - 1215 193
A
235
77
17
0
.6
Ø9 A (1:8)
18W - 820
125.5 36W - 1435
18W - 750
25 35 36W - 1365
235
621
208
260
309
275
Dimensions in millimetres
SOLID CEILING TYPES 85
Typical aperture:
DIMENSIONS
18W - 770
36W - 1385
18W - 600
36W - 1215 193
310
235
94
24
34
60
Min. - 34mm
Swing out arms Max. - 70mm
125
18W - 775
10
36W - 1390
260
621
208
315
Dimensions in millimetres
86 RECESSIBLE VL104 I
3 Hour
Operation
TECHNICAL SPECIFICATION
LAMP TYPES TERMINALS
18W & 36W bi-pin fluorescent (T8) 4 core up to 4 mm2 conductors with looping. Through wiring
facility as standard. Terminals for live constant, live switched,
POWER SUPPLY neutral & earth are provided. External earth terminal as standard.
Cable entry devices (i.e. glands) must maintain the IP rating Standard mounting is fixed cantilever side brackets, there is also
for the luminaire. a provision for drop rod mounting.
Please refer to pages 88 and 89 for details of ceiling types
and dimensions.
Std. Cat Ref. Wattage Lamp Type /MES Modular - Exposed “T” ceiling and Spring
“T” ceiling types
V104I/218/BI** 2x18W Bi-Pin
V104I/418/BI 4x18W Bi-Pin /120 Specific voltage 110/130V
V104I/236/BI** 2x36W Bi-Pin /254 Specific voltage 254V
V104I/436/BI 4x36W Bi-Pin
/25 25mm entry
V104I/218/BI/EM** 2x18W Bi-Pin
V104I/418/BI/EM 4x18W Bi-Pin /LG Low glare louvre
ACCESSORIES
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
88 CEILING TYPE OPTIONS
View of Exposed “T” Ceiling with recessed luminaire, typical 600mm x 600mm tile grid mounting system (/MES).
View of Spring “T” Ceiling with recessed luminaire, typical 600mm x 600mm tile grid mounting system (/MES).
45
18W - 617
36W - 1227
18W - 500
547 36W - 1100
X Sectional View 500
4 Holes Ø8
4 x Ø21mm Holes
for cable entry
18W - 547
36W - 1147
600
65
18W - 600
36W - 1200 107
38
X Sectional View
Dimensions in millimetres
4 Holes Ø8
500
570
X Sectional View
107
4 x Ø21mm Holes
for cable entry
18W - 617
36W - 1227 547
600
18W - 670
36W - 1280
X Sectional View
Dimensions in millimetres
178
Ø208
Ø385
Dimensions in millimetres
INDUSTRIAL AREA PENDANT LUMINAIRE 91
ORDERING REFERENCE
TECHNICAL SPECIFICATION
LAMP TYPES WEIGHT
TERMINALS
2
3 core up to 2.5 mm conductors with looping. Through wiring
facility as standard. Terminals for live, neutral & earth are
provided. External earth is an option.
CABLE ENTRIES
MATERIALS
Reflector
SMONN-00002
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
92 MONARCH II VL15 I
new shot?
327
M6 mounting
Designed & manufactured
to EN60598-1
447
Ceiling mounted
460 Dia.
Enclosed reflector model
Dimensions in millimetres
INDUSTRIAL AREA PENDANT LUMINAIRE 93
ORDERING REFERENCE
Mercury Vapour - 220, 230, 240V 50Hz (50, 80, 100 & 125W) /ST Stanchion mounted version
HPS/Metal Halide - 220, 230, 240, 254V 50Hz (70, 150, 220, 250 & 400W)
/PE Pendant mounted version
TERMINALS
/ER Enclosed spun reflector
Side entry luminaire, 3 core up to 6mm2 max conductors with
looping.
CABLE ENTRIES
Cable entry devices (ie. glands) must maintain the IP rating for
the luminaire.
MATERIALS ACCESSORIES
Enclosure Painted aluminium alloy.
Diffuser Borosilicate glass. Wire guard for low wattage glass globe
Gasket Silicone rubber. (up to 150W)
E0850-0042
WEIGHT
HPS - 7.5Kg (50W), 9.0Kg (100W) Wire guard for high wattage glass globe
(200W/400W)
HPS/Metal Halide - 8.0Kg (70W), 11.0Kg (150W), E0850-0044
15.0kg (250W), 15.5Kg (400W)
Mercury Vapour - 7.5Kg (80W), 8.0Kg (125W), 15.0Kg (250W),
15.5Kg (400W) Wire guard for enclosed reflector
E0850-0043
SUSPENSION
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
94 VANGUARD VL20 I
B
48
to EN60529
206
254 CRS
292
48
170
Dimensions in millimetres
INDUSTRIAL AREA BULKHEAD LUMINAIRE 95
ORDERING REFERENCE
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
SON - 70W Main Body LM6 die cast aluminium, with epoxy
MH - 70W paint finish.
MBF - 80W Lampglass Borosilicate (diffused pattern).
GLS - 150W (max). Gasket Silicone.
External Fasteners Stainless steel.
POWER SUPPLY
WEIGHT
HID: 220V / 230V / 240V / 254V 50Hz (60Hz option).
GLS: 250V (max). Discharge lamp versions - 6.5Kg.
GLS version - 4.85Kg.
POWER FACTOR
SUSPENSION
Better than 0.85
Four Ø10.3mm fixing holes are provided outside gasket to ensure
TERMINALS the IP rating.
3 core up to 4 mm2 conductors with looping. Through wiring The luminaire may be mounted in any orientation, the
facility as standard. Terminals for live constant, neutral & earth lampholder should be at the bottom when the lamp is
are provided. External earth terminal as an option. mounted vertically.
CABLE ENTRIES
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
96 REGENT VL71 I
465 105
80 24.5
250
to EN60529
500
to EN60598-1
100
522.5
219
50
5 holes Ø13mm
56 56
150 150
Dimensions in millimetres
INDUSTRIAL AREA FLOODLIGHT LUMINAIRE 97
ORDERING REFERENCE
POWER FACTOR
TERMINALS
2
3 core up to 6 mm conductors with looping. Terminals for live
constant, neutral & earth are provided. Internally earthed,
external earth terminal as standard.
CABLE ENTRIES
MOUNTING
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
98 FLOODLIGHT VL100 I
Gear chamber
anti-vibration
washer.
138.2
102.5
125 125
45
141.1 404
187.5
3 mounting holes:
centre hole Ø21mm
outer holes Ø14mm
Dimensions in millimetres
INDUSTRIAL AREA FLOODLIGHT LUMINAIRE 99
ORDERING REFERENCE
TECHNICAL SPECIFICATION
LAMP TYPES MATERIALS
SON - 150W Tubular Main body LM6 aluminium alloy (Die Cast).
SON and MBI - 250W Tubular Lampglass Toughened glass.
SON and MBI - 400W Tubular
Tungsten Halogen - 500W Max (single ended) WEIGHT
GLS - 500W Max
400W SON Lamps - 16Kg
POWER SUPPLY
SUSPENSION
220V, 230V, 240V and 250V 50/60Hz
250V Max for halogen & GLS Galvanised steel stirrup bracket with protractor for elevation
angle setting.
POWER FACTOR
CABLE ENTRIES
ACCESSORIES
To calculate photometric values for lighting design, please use the free Victor LiteGuide™ software package.
To request your copy, please contact your local Victor agent or download a copy from the website.
Design is subject to alteration without notice. Please refer to the website www.victor-lighting.com for the latest details.
All products are sold subject to our conditions of sale, available on request.
100 LAMP LUMEN OUTPUT AND EFFICACY
The following table shows typical lumen outputs for common lamp types which can be used with Victor Lighting luminaires.
Individual lamps form different manufacturers may vary for those stated in this table. If you require details on a specific lamp,
please check with the lamp supplier.
Lamp lumen output also decreases over time and with continuous usage.
18W T8 1350 75
36W T8 3350 93
58W T8 5200 90
Compact Fluorescent
11W 900 82
18W 1200 67
26W 1800 69
HPS, SON-T
70W 5900 84
150W 14500 97
HPS, SON-E
50W 3500 70
70W 5600 80
150W 14000 93
50W 4000 80
70W 6500 93
50W 3600 72
70W 6000 86
100W 9500 95
70W 4800 69
100W 8100 81
150W 12600 84
250W 17100 68
400W 32400 81
70W 4800 69
100W 7700 77
150W 11300 75
250W 20000 80
400W 38000 95
Mercury Vapour
50W 1800 36
80W 3800 48
125W 6300 50
250W 13000 52
400W 22000 55
Mercury-Tungsten Blended
160W 3100 19
Induction QL
55W 3500 64
85W 6000 71
165W 12000 73
GLS (frosted)
60W 720 12
100W 1360 14
150W 2200 15
200W 3100 16
102 VICTOR LIGHTING - COMMON SPARE PARTS
Although all the products on the Victor Lighting range are made to the highest standards using quality materials and
workmanship, over time these may need to be replaced. To assist you we have compiled a list of the most commonly
requested spare parts and ballasts for our Hazardous Area range.
If you need to replace an item that is not listed below, please contact your local agent or directly to info@victor-lighting.com
TRIDENT VL125/VL126
EXCALIBUR VL19E/VL24E
PATHFINDER VL114E/VL114S
VL77/VL78
VL104C
VISCOUNT VL51A/VL52A
TITAN VL38
TITAN VL39
TITAN II VL147
VL64 EP
VL65A
MARQUIS II
MONARCH VL14
MONARCH II VL15
VANGUARD VL20
REGENT VL71
VL100
EXPLOSIVE GASES
Using the table FIG. 1.0 below, ascertain first if the gas present is a group I or group II gas.
● Group I gases are firedamp methane gas. These are usually associated with mining applications.
● Group II gases are all other explosive gases as listed opposite with relevant subdivisions A, B or C according
to the nature of the chemical content. These are usually associated with surface applications.
FIG 1.0
COMBUSTIBLE DUSTS
If an area is classed as hazardous due to the presence of combustible dust, it is important to establish if it is a
metallic or non metallic dust. The latest series of standards for electrical apparatus in the presence of
combustible dust that will provide protection concepts, installation and selection requirements will be the
EN/IEC 61241 series.
The most commonly used part of the EN 61241 series applicable to luminaires will be EN 61241-1: Protection by
enclosures with marking "tD". It should be noted that this standard outlines to two techniques that provide
equivalence in safety but different requirements in terms of selection and installation.
The two techniques are "Practice A" and "Practice B", practice B is principally a prescriptive based technique
where practice A is performance based. Practice A is the most commonly used technique, where dust may
form in layers up to 5mm thick and where a temperature difference of 75K is specified between the maximum
surface temperature and the ignition temperature of the dust; the method of determining dust ingress is
according to IEC 60529 the IP code. Practice A and Practice B apply to Zones 21 and 22. For clarity the zones
for dust can be described as follows:
ZONE 21
Where a combustible dust, as a cloud, is likely to occur during normal operation in sufficient quantity to be
capable of producing an explosive concentration of combustible or ignitable dust in mixture with air.
ZONE 22
In this zone, combustible dust clouds may occur infrequently, and persist for only a short time, or in which
accumulation or layers of combustible dust may be present under abnormal conditions and give rise to
ignitable mixtures of dust in air. Where following an abnormal condition, the removal of dust accumulations or
layers cannot be assured, then the area shall be classified as zone 21.
112 INTERNATIONAL REFERENCE GUIDE TO HAZARDOUS AREAS
STEP 2
Now having established which gas or dusts are present, the next thing to establish is the hazardous area category.
FIG 1.1 below sets out the zone definitions to classify your area.
Zone 0 An area in which an explosive atmosphere is continuously present or for long periods or frequently
Zone 1 An area in which an explosive atmosphere is likely to occur in normal operation occasionally
Zone 2 An area in which an explosive atmosphere is not likely to occur in normal operation
and if it occurs it will exist only for a short time.
(Zone 2 is often described as the ‘remotely hazardous area’.)
FIG 1.1
Using the guide in FIG 1.1 you can now classify the hazardous area into a zone. If you are unsure as to which
zone an area should be classified as, please refer to your local health and safety officer or your fire brigade
for guidance. Victor Lighting or any other manufacturer of hazardous area equipment is not able to offer any
advice in this respect.
STEP 3
Having now identified the zone and gas/dust present in the hazardous area, the ignition temperature of the
gas/dust needs to be ascertained. For atmospheres containing explosive dust, the ignition temperature of the
dust needs to be established both when it is in a cloud and when it is in a layer. This information can be found
from the table in FIG 1.2.
EXPLOSIVE GASES
FIG 1.2
STEP 4
Knowing the ignition temperature of the explosive atmosphere, the zone and the gas grouping or dust type
we are better able to decide upon the appropriate type of electrical apparatus required. It is important
therefore to understand the certified protection concepts recognised for safe operation as used for an ATEX
category and/or within a zone.
The category in ATEX links to types of protection listed below. If the ATEX categories are used as a cross
reference to zones then the protection concepts listed apply.
1 Ex 'ia' Intrinsic Safety. EN 60079-11 Where the design limits the ignition spark energy to
below that which will ignite the explosive gas.
Safe even with two simultaneous faults.
Special protection for EN 60079-26 Special construction normally based on the use of
Category 1 [and Zone 1] two independent types of protection both
individually suitable for Category 1.
Ex 'e' Increased Safety EN 60079-7 Design prevents any ignition from occurring by
ensuring no normally sparking components are
used and other components reduce the risk of
causing a fault that may cause an ignition. This is
achieved by strictly controlling and limiting the
temperature of components, ensuring adequate
insulation is used, all electrical connections are
true and the IP rating offers adequate protection
against contamination.
Ex 'd' Flameproof EN 60079-1 The components may produce sparks that could
cause ignition of the explosive gas but which are
housed in an explosive proof enclosure. The design
of the enclosure may allows the gas to enter, but
any explosion is contained within the enclosure.
114 INTERNATIONAL REFERENCE GUIDE TO HAZARDOUS AREAS
Ex 'ib' Intrinsic Safety As Ex ia As Ex ia but allows for the occurrence of only one
component fault.
Ex 'q' Powder filling EN 60079-5 This technique involves the mounting of potentially
incendive components in an enclosure filled with
sand or similar inert powder. The sand prevents
explosive ignition. It was originally developed to
protect heavy duty traction batteries. It is now
primarily of use where the incendive action is the
abnormal release of electrical energy by the
rupture of fuses or failure of components used in
electronic apparatus. The likelihood of possible
incendive failure of the components is assessed
and precautions taken to minimise it. Usually Ex q is
used for discrete sub-assemblies and components
inside Ex e apparatus.
Ex 'nA' and Ex 'nR' EN 60079-15 The Ex non sparking 'nR' denotes the use of a
restricted breathing enclosure. This technique is
used where internal components run hotter than
the required T rating. The T rating is achieved by
mounting the offending components in a sealed
enclosure to prevent the explosive atmosphere
contacting them. This technique by virtue
incorporates high IP ratings of minimum IP65.
Ex 'o' Oil Immersion EN 60079-6 Ex 'o', involves the immersion of the sparking
components in oil with controlled venting.
FIG 1.3
115
STEP 5
Now that you have clarified the gases/dusts present, their ignition temperature, the zone and
applicable protection methods, the certified temperature codings must be understood for choosing the
correct luminaire. Failure to understand the relationships could result in selecting an inappropriate
luminaire for the zone and atmosphere. If the luminaires T rating code signifies the surface temperature
of the equipment is greater than the ignition temperature of the gas/dust present, the luminaire will
ignite the surrounding atmosphere causing an explosion.
Below FIG 1.4 shows the temperature codes related to surface temperatures. Using this table check the
ignition temperature of the gas/dust present, as shown in FIG 1.2. This will then indicate the suitability of
the equipment you have selected, or the temperature rating of the equipment you need to select.
T1 450
T2 300
T3 200
T4 135
T5 100
T6 85
FIG 1.4
STEP 6
The environment that the equipment will operate in is also important. Many environments are arduous
and may involve the equipment being subject to the following:
FIG 1.5
In order to ensure that the equipment selected will perform in the environment for which it is intended,
the following factors of equipment performance need to be considered.
● Ambient temperature - Does the equipment have certification to operate within the minimum
and maximum temperatures of the environment ?
● How much dust/liquid etc will the equipment be subjected to and for how long ?
● Will the equipment be subject to any likely impact during its service life ?
● Are there any chemicals/vapours present that could attack luminaires with plastic enclosures ?
When selecting equipment, the product information will state the certified operating temperature such
as the example below. If in selecting equipment the product information contains no statement or
reference to ambient temperature be very sceptical and do not assume. Always check and obtain
written confirmation from the manufacturer.
Example Floodlight VL65A
-50OC to +55OC
116 INTERNATIONAL REFERENCE GUIDE TO HAZARDOUS AREAS
Always check that the ambient temperature certification is applicable to your relevant choice of
product as maximum ambient performances are often quoted and may only be applicable to certain
product variants.
If the environment will subject the equipment to any dust/fibres/liquids, ensure it is certified to an
appropriate level of ingress protection. This can be done using the table below.
No Protected against solid Protected against solid Protected against solid Protected against solid Protected against dust Completely protected
Protection bodies of 50 mm and bodies of 12.5 mm and bodies of 2.5mm and bodies larger than 1 mm (no harmful deposit) against dust
greater (e.g. accidental greater (e.g. finger) greater (e.g. tools, wires) (e.g. thin tools and fine
contact with the hand) wires)
No Protected against Protected against Protected against Protected against Protected against Protected against Protected against Protected against
Protection vertically falling drops of water drops of water splashing water from jets of water from all powerful jets of the effects of the continuous
drops of water falling up to 15o falling up to 60o all directions directions water from all temporary effects of immersion
(condensation) from the vertical from the vertical directions immersion in water in water having
regard to specific
conditions
FIG 1.6
A third figure is sometimes used in the index of protection. This relates to the degree of mechanical
protection the equipment has been certified as having. This relates to the degree of impact energy the
equipment will stand before its hazardous area and ingress protection certification is compromised. FIG
2.2 below details the levels of protection.
IK CODE IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10
Impact a 0.14 0.2 0.35 0.5 0.7 1 2 5 10 20
energy
STEP 7... FINALLY
Joule
Having covered all the rules and safety considerations of the operation of electrical equipment in a
hazardous area it is
a not protected tonow possible to select a safe and appropriate product.
this standard
FIG 1.7
GOST-R (Russia)
Gosstandart of Russia is responsible for:
● establishment of the general rules and recommendations for certification of products,
services (works) and systems of quality and production harmonised with international
norms and rules;
● carrying out the State registration of the mandatory and voluntary certification systems
and of the conformity marks.
Russia participates in the following international certification systems:
● System of the International Electrotechnical Commission (IEC) for tests of electrical
equipment on conformity to the safety standards.
FSETAN
Rostekhnadzar (Federal service on ecological, technical and nuclear supervision) was
formally known as Gosgortekhnadzor (GGTN) and is responsible for the issue of permits and
licenses for a broad range of machinery and equipment. As a separate entity to
Gosstandart, FSETAN requires product types that fall under its jurisdiction to undergo a further
certification process.
All potentially hazardous machinery and equipment, such as pressure vessels, boilers, burners,
lifts and cranes is subject to FSETAN approval, even if it has already obtained a GOST-R Coc.
GB (China)
The GB mark is the Chinese national safety certification scheme. These standards are aligned
to the latest IEC standards.
TIS (Thailand)
Thai industrial standards are a national product certification scheme. This is designed to
ensure products used within the county meet minimum electrical and quality standards.
118 INTERNATIONAL REFERENCE GUIDE TO HAZARDOUS AREAS
STEP I
As detailed in the European section in STEP 1 the gas/dust/fibre present in the hazardous area needs to
be identified and classified under the CEC\NEC (North American) classifications detailed in FIG 1.9.
GROUP E
MATERIAL CLOUD LAYER MATERIAL CLOUD LAYER MATERIAL CLOUD LAYER
Aluminum 650 760 Alfalfa 460 200 Wheat flour 380 360
Magnesium 620 490 Cocoa 420 200 Cellulose acetate 450 390
Titanium 330 510 Coffee 410 220 Ethyl acetate 450 390
Zinc 630 430 Corn 400 250 Nylon 500 430
Bronze 370 190 Cornstarch 380 200 Polyethylene 450 380
Chromium 580 400 Malt 400 250 Polystyrene 560 -
Tin 630 430 Skim milk 490 200 Epoxy 540 -
Cadmium 570 250 Rice 440 220 Polyurethane 550 390
Sugar 350 400 Cork 490 280
GROUP F Wheat 480 220 Wood flour (white pine) 470 260
MATERIAL CLOUD LAYER
Coal (Pittsburgh Seam) 610 180
FIG 1.9
Using FIG 1.9 we can also ascertain the ignition temperatures of the identified gas/dust/fibre present.
STEP 2
Select the Gas/Dust/Fibre type present from FIG 1.9 and note:
● Material classification
I = Gas
II = Dust
III = Fibre
● If the material present is a dust or fibre and whether it forms a cloud or a layer on surfaces
STEP 3
Assess the hazardous area as in STEP 2 of the european section with regard to the potential frequency
and longevity of an explosive atmosphere. This can be done using the classifications below.
STEP 4
Now having defined the explosive gas/dust/fibres present, the nature of their presence, their ignition
temperature and the classification of the hazardous area we, need to determine the temperature
classifications to ensure the selection of equipment which will be safe in operation.
The classifications, which are similar to Europe, are further subdivided as follows
FIG 2.0
Product markings will often show the actual rated temperature in brackets next to the temperature
code to make judgement and selection easier.
STEP 5
Finally we need to take cognisance of the environment in which the equipment will be operating with
respect to the concentration of liquids/gas/dust/fibres and ambient temperature.
In North America environmental protection is classified using the NEMA standard as opposed to the
European IP protection standard.
On establishing these operating conditions we can determine the desired environmental protection
required of the equipment by using the table below.
FIG 2.1
* These fibres and flyings are non hazardous materials and are not considered sa Class II or III combustable dust or easily ignitable
fibres or flyings. For these types of material refer to the Canadian Electrical Code.
** External operating mechanism(s) shall not be required to operate when the enclosure is covered in ice.
*** External operating mechanism(s) shall be operable when the enclosure is covered in ice.
FIG 2.1
121
North American Gas & Vapour Groups CENELEC/IEC Gas and Vapour classification
Group A IIC
Group B IIC
Group C IIB
Group D IIA
122 HAWKE - CABLE GLANDS
Victor Lighting is a division of Hubbell Ltd and part of the Hubbell group of companies. Through its market
leading brands, Hubbell can also offer a range of related electrical connection and lighting products.
Most types of hazardous and industrial lighting requires a secure interface between the luminaire and the electrical
supply cable. Victor Lighting therefore recommends the use of Hawke International cable glands.
The following is a selection from the range of Hawke glands available for further information visit www.ehawke.com
501/421
501/453/UNIVERSAL
501/453/RAC
✓
hazardous areas.
Ex nR
Suitable for restricted breathing applications.
ICG 653/UNIVERSAL
✓
flameproof barrier seal on the individual insulated cable
Ex nR cores and prevents entry of the products of an explosion
into the cable's surrounding environment. It also provides
an IP seal on the cable outer sheath. The cable gland is
suitable for cables that are not effectively filled and for
cables with a 'soft' inner sheath that exhibit "Cold Flow"
characteristics.
The cable gland is dual certified EExd and EExe and is
suitable for installations in Zone 1 (21) and Zone 2 (22)
hazardous areas, where the enclosure is greater than 2
litres in volume and contains an ignition source and
Suitable for restricted breathing applications.
requires IIC apparatus.
HAWKE - HAZARDOUS AREA CONNECTORS 123
ATEX
Hawke International ATEX approved connectors are ideal for explosive environments commonly found in Oil and Gas exploration,
production and process plants. Their features, however, also offer numerous benefits in explosive dust environments as well as
harsh and hostile non-explosive applications where temporary but safe disconnection of power is critical.
Hawke International's Ex range of connectors permit the safe and rapid service, repair and replacement of key plant, provide
quick connection to temporary equipment and greatly reduce hook-up time in capital-intensive processes.
The Ex range of connectors cover three main application areas: Instrumentation, control and power.
For a guide as to which Ex connector may be best suited to an individual application the table below outlines the main variables.
SELECTION OVERVIEW
Connector Minimum Number Maximum Number Minimum Maximum Maximum Maximum Live
Type of Pins of Pins Conductor Size Conductor Size Voltage Current (amps) Demate
Instrum 4 8 0.14 2.5 250V 10 ✓
Control 3 60 1.5 35 660V 125 ✗
Power 1 4 50 630 750V* 780 ✗
INSTRUM Ex
This revolutionary design allows the live de-mating of signal and power in hazardous areas
safely and quickly. The Instrum connector is available with two insert options: the 4-way
option will accept cores ranging between 0.5mm² and 2.5mm² and can operate up to a
maximum current of 10A at 250V AC. The 8-way option, designed predominantly for
Ethernet applications, will accept cores ranging between 0.14mm² and 0.37mm²
and can carry 1A at 250V. Instrum connectors include an integral Hawke cable gland
for easy termination of both armoured and un-armoured cables.
CONTROL Ex
The 3rd generation of Control connectors include many features and refinements as a
result of consumer feedback. And are suitable for control and low/medium power
applications. The robust stainless steel body can hold up to 60 contacts and will accept
conductor sizes ranging between 0.5mm² and 35mm², operating up to 125A and 600V.
Further information on recommended cable glands for use with the ControlEx connectors
can be found at www.ehawke.com
POWER Ex
The Power range of connectors have been designed specifically for the extremely
demanding requirements of higher power applications. Inserts are available with 1 to 4
contacts with a conductor acceptance range of between 50mm² and 630mm² operating
up to 125A and 660V.
There are several innovative features common across the range of Hawke ATEX connectors. Despite their highly advanced
design and technical features, the range is extremely simple to use and quick to terminate.
Impossible to cross mate Ingress and deluge protected
The unique mechanical keying system prevents All Hawke ATEX connectors meet the
contact damage and ensures safe use by requirements of IP66 and IP67 to IEC60529.
eliminating the possibility of misconnection of They are also deluge protected to DTS01
circuits. Machined key and keyway also offering long term protection in onerous
ensures connector alignment. environments.
www.ehawke.com
124 HAWKE - HAZARDOUS AREA ENCLOSURES
Features Features
The Ultimate in Robust GRP Construction Robust Stainless Steel Construction
Designed to withstand impact resistance up to 20Nm. Enclosure material thickness ranges between
GRP Construction provides a high degree of resistance 1.2 - 2.0mm with 3mm thick gland plates.
to corrosive atmospheres. Durable stainless steel rating label.
Integral Steel Earth Continuity Plate (PL7 Series) Electropolished Surface Finish
Provides internal/external earth continuity through to Provides high levels of corrosion resistance.
the two external mounting feet.
Softer Finished Rounded Edges
Anti-Static Properties Safer manual handling of enclosure and gland plates.
Removes the risk of ignition sources through static
induced sparking. Rigid Slotted External Mounting Feet
Insulation Resistance in accordance with Allows enclosure to be hung onto the structure.
EN 50014 : 1998, which does not exceed 1 G Ω.
Corrosion Resistant Stainless Steel Lid Fixing
External Mounting Feet Screws with Nylon Retaining Washers
Eliminates the need to remove the lid when mounting Prevents loss of screws during assembly and
the enclosure on the wall. maintenance.
Corrosion Resistant Stainless Steel Lid Fixing Superior Silicone Sponge Gasket
Screws with Nylon Retaining Washers DTS01 deluge protection witnessed by EECS.
Prevents loss of screws during assembly and Provides ingress protection to IP66.
maintenance. Durable with excellent UV stability and
chemical resistance.
One Piece Durable Captive Moulded Good chemical resistance - EMC mesh option.
Silicone Gasket
DTS01 deluge protection witnessed by EECS. Extensive Range of Enclosure Sizes Available
Provides Ingress Protection to IP66. Nine enclosure sizes available. Sizes range from
Optimum performance at low and high temperature 153 x 233 x 130 to 740 x 1000 x 210.
extremes. Gland plates offered on two side faces and bottom
face of each enclosure.
Stainless Steel Rating Label
Highly durable and corrosion resistant.
• Better access for faster installation, easier inspection and on-site modification.
• Solid back plate and base frame with a removable clamshell style lid.
• Seals shielded from the environment.
• Clip-in quick release gland plate.
• Under-wiring possible.
• Superior Silicone Compression Gasket.
• Large Terminal Capacity.
KILLARK-NEC ELECTRICAL RANGE 125
The Killark range encompasses industrial and explosion proof fittings in both iron and
aluminium including: HID & fluorescent lighting, emergency lighting, floodlights,
enclosures & controls, plugs and receptacles, motor starters and distribution equipment.
Killark became a division of Hubbell in 1985 and since then, increased levels of capital
investment have funded major new product initiatives enabling the group to compete
worldwide with an extensive electrical construction product range covering, conduit
raceway fittings, junction boxes, enclosures, standard and custom control assemblies,
lighting fixtures as well as plugs and sockets.
As part of Hubbell, the strengths of Killark and Victor Lighting are now combined.
This partnership has created the largest, most comprehensive range of lighting products
and associated apparatus for hazardous locations available within the global market.
Hubbell and Killark are well represented on Codes and Standards committees in the US,
Canada, Mexico and internationally. This affords the most cost competitive solutions to be
offered to user requirements on a world wide basis, regardless of locality or installation
constraints.
Both companies have reputations for customer specific solutions to complex and
challenging hazardous location requirements, utilising proven designs and value added
engineering input, and these solutions are enhanced by access to comprehensive
laboratory facilities. In house testing laboratories allow product development efforts to
continually support new product development and solutions to specific user defined
requirements.
With a Total Quality Management programme and ISO 9001:2000 accreditation, Killark
and Victor Lighting are dedicated to meeting customer needs, with engineering solutions,
new product development and on-time delivery in every phase of the project. This
underlines an already proven ability to supply lower cost total system solutions and savings
over the entire lifetime of a project.
For further information on this NEW expanded range of products or to obtain a dedicated
Killark brochure, simply refer to your usual Victor Lighting personnel. Photometric data on
the Killark range is also available from the LiteGuide™ lighting design software.
www.hubbell-killark.com
Making Hazardous
Environments Work
Victor Lighting
PO Box 5571
Glasgow
G52 9AH
Scotland
Email: info@victor-lighting.com