You are on page 1of 28

SchneiTec CHINT Introduction A CHINT Company

About SchneiTec-CHINT

SchneiTec CHINT Co.,LTD was founded in


March 2021, which is a Joint Venture
company that under SchneiTec Group and
CHINT Group respectively. The factory is built
to focus on MV Products, gradually realize
the design ability, local manufacturing ability,
installation and after sales ability, and
cultivate the local sales, management and
technical team.
Milestone of SchneiTec-CHINT

Trial Operation for


JV Agreement Signing SchneiTec CHINT factory

10/2020 11/2020 06/2021 02/2022

Foundation Construction for Opening Ceremony


SchneiTec CHINT factory for SCHNEITEC CHINT on
Feb. 28, 2022
Factory Construction Process

Mar. 2021 Apr. 2021

Jun. 2021 Jun. 2021 May. 2021


Factory View of SchneiTec-CHINT

11/2020 06/2021 02/2022


Products Scope

SchneiTec Chint is a manufacturer of MV electrical products

MV Products

MV Switchgear MV Transformer Capacitor Bank

KYN28 XGN15 S Series TBB Series


MV Switchgear

Field of application (Indoor)

 Energy: HV/MV substations, MV/MV substations, Power


Generation

 Infrastructure and Buildings: Hospitals, Airports, Subways,


Railways, Industrial & Commercial Buildings.

 Industries: Oil & Gas, Metal & Mines, Automotive, Food &
Beverages.

Target Customer

Airport Data Center Power Generation Oil & Gas Metal & Mines Buildings Substation
MV Switchgear
KYN28 Withdrawable VCB

Panel Solution

Single Line Diagram

Incomer Bus Coupler Bus Riser Feeder PT Panel


Incomer PT Feeder Bus Coupler Bus Riser Feeder PT Incomer
MV Switchgear
KYN28 Technical Data
IEC Standard: 62271-200

SN Item Technical Data

1 Rated Voltage 12kV 24kV

2 Rated Current 630~5000 A 630~3150 A

Power Frequency
42kV/48 kV 65kV/79 kV
withstand Voltage (1min)
Rated
3
Insulation Level
Lightning Impulse
75kV/85 kV 125kV/145 kV
withstand Voltage (Peak)

4 Rated Short Circuit Breaking Current 25~50 kA 16~31.5 kA

5 Rated Short-time withstand Current (4S) 25~50 kA 16~31.5 kA

6 Rated Short Circuit Making Current (Peak) 63~125 kA 40~80 kA

7 Rated Peak Withstand Current (Peak) 63~125 kA 40~80 kA

8 Protection Class IP4X IP4X


Project Case
Customization and Standard Marketing

 End User: Electricity of Sihanouk Province


 Highlight: Combination with ABB Panel
 Local Service: Installation and Commissioning
Customized Design
KYN28-24 EDC Structure

Combination

EDC Standard Design


800(W) x 1900(D) x 2400(H)
MV Switchgear
XGN15 Semi-insulated RMU

Panel Solution

Panel Feature
-Compact structure
-Easy Operation
-Safe Reliability
Main Switch
-SF6 Load Break Switch -630A/25kA
-SF6 Load Break Switch with fuse -125A/31.5kA.
Dimension W x D x H (mm)
- 500 x 1000 x 1725
MV Switchgear
XGN15 Technical Data
SN Item Technical Data

1 Product Type XGN15-12(F) XGN15-12(F-R) XGN15-12(Z) XGN15-24(F) XGN15-24(F-R)

2 Rated Voltage 12kV 24kV

3 Rated Current 630A 125A 1250A 630A 125A

Power Frequency withstand


Rated 42kV/48kV 42kV/48kV 42kV/48kV 65kV/79kV 65kV/79kV
Voltage (1min)
4 Insulation
Level Lightning Impulse withstand
75kV/85kV 75kV/85kV 75kV/85kV 125kV/145kV 125kV/145kV
Voltage (Peak)

5 Rated Short Circuit Breaking Current / 31.5kA 31.5kA / 31.5kA

6 Rated Short Circuit Making Current (Peak) 63kA 80kA 80kA 63kA 80kA

7 Rated Transfer Current / 1500A / / 1000A

8 Rated Short-time withstand Current 25kA/4s / 31.5kA/4s 25kA/4s /

9 Protection Class IP4X IP4X IP4X IP4X IP4X


Full Industry Chain
MV Panel Components

Main Components

Comprehensive
VCB CT PT
Protection Relay

Zero-sequence CT Surge Arrestor Earthing Switch Load Break Switch


Distribution Transformer
Oil-immersed transformer up to 22kV/3150kVA

Applied for Power Generation, Substation, Industries end user etc.


(Indoor & Outdoor)

Material: Copper or Aluminum Coil, Iron Core.

Technical Requirement as per IEC Standard: 60076


-Low Loss -Low Noise
-Low Temperature rise -High Efficiency
-Maintenance-free

Accessories: Temperature Gauge, Oil Level Gauge etc.


Distribution Transformer
Production Process

HV Coil Production LV Coil Production


Distribution Transformer
Production Process

Winding Assembly

Vacuum Drying
Distribution Transformer
Assembly Production Equipment

Oil Filter Test Area

Vacuum Drying Oven


Project Case
Fast Reaction, Shortest Lead Time

 End User: Pursat Glove Factory


 Highlight: 3 Days delivery after Contract Sign
 Local Service: Installation and Commissioning
Power Transmission
Improve Power Quality Solution
Loss 10% of Energy in the System

Energy will be loss due to the resistance and


the heating of conductors when current
through the power transmission and
distribution line.

The losses are equivalent to approximately


10% of the total electricity that transported
between power plant and end users.

To ensure that Region A would supply


100MW to Region B, the Generator shall
export 110MW energy.
Improve Power Quality Solution
Improve Power Quality

Compensate the Power Factor for Power Grid


Reduce the energy loss during the Power T&D
Enhance the power voltage quality and equipment
utilization.

Capacitor Unit Capacitor Bank Capacitor Installation


Green Energy Solution
Solar Home System

Invertor
Green Energy Solution
Solar Home System Characteristic
Project Case
Empower Cambodia by SHS

 End User: Khmer Family in Cambodia


 Highlight: Bring the electricity to local family
 Local Service: Installation and Commissioning
Factory Strength

Full Industry Quality


Technical Support Sales & Service
Chain Management

To be Competitive Electrical Manufacturer


Thanks

You might also like