You are on page 1of 4

PBMN

flush

Main features
Flush membrane
„„ „„High overpressure resistance
Fully welded version
„„ „„Available with optional ATEX
Robust stainless steel housing
„„ approval
„„ External programming of zero
point and span with FlexPro-
grammer 9701

Applications
„„Food
„„Beverage
„„ Water treatment
„„ Chemical

Main characteristics Protection rating IP65 (EN 60529) up to IP67 depending on


electrical connection
Measuring range -1 ... 0 bar up to 0 ... 400 bar
Vibration 1.5 mm p-p (10 – 57 Hz), 10 g (58 Hz – 2 KHz)
Turn down 5:1
IEC60068-2-6 10 cycles within 2.5 h per axis
Long term stability ≤ ± 0.1% FS / Year
Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Shock 50 g/11 ms 100 g/6 ms
(Linearity, hysteresis, re- IEC60068-2-27 10 x Imp. per axis and direction
peatabillity, error of span and
zero point) Bump 100 g/2 ms
Performance after [Turn-Down] * [Accuracy] FS IEC60068-2-27 4000 x Imp. per axis and direction
Turn-Down
Random 0.1 g2/Hz (20 Hz – 1 KHz)
Technical specifications IEC60068-2-64 30 min per axis (>10 g RMS)
Measuring principle Piezoresistive silicon sensor
Electrical specification
Measuring ranges -1 ... 0 bar up to 0 ... 400 bar
Type of pressure Relative / Absolute Output signal / 4 … 20 mA / 8 … 30 VDC
Power supply 0…10 V / 13 … 30 VDC
Turn down 5:1
Load impedance
Accuracy (20 °C) ≤ ± 0.5% FS, 0.25% FS, 0.1% FS Current ouput RΩ = (Usupply-8 V) / 20 mA
(Linearity, hysteresis, re-
peatabillity, error of span and
Voltage output > 5 KΩ
zero point) Insulation resistance >100 MΩ at 500 VDC
Zero thermal drift ≤ ± 0.03% FS/10 K Electrical connections See page 3
Span thermal drift ≤ ± 0.03% FS/10 K
Material
Long term stability ≤ ± 0.1% FS / Year
Design and specifications subject to change without notice

Response time ≤ 5 ms Process connection SS 1.4404 AISI 316L or Hastelloy-C


(10 … 90%) Housing SS 1.4404 AISI 316L
Process connections See page 3 Diaphragm SS 1.4435 AISI 316L or Hastelloy-C
Environment Sealing NBR, EPDM or FKM (Viton®)
Cable PUR
Temperature
Storage -40 ... + 85°C
Compensated range -40 ... + 85°C
Medium -40 ... +125°C
(without cooling neck)
Medium -40 ... +200°C
(with cooling neck)
Ambient -40 ... + 85°C
2013-04-16

www.baumer.com Data sheet A11.35 Page 1 / 4


PBMN
flush

ATEX Approvals
ATEX II 1G All versions without cooling neck, CE conformity EMC directive 2004/108/CE in accordance with
Ex ia IIC T4/T6 Ga DIN connector and with output EN61000-6-2, EN 61000-6-3
signal code A1
ATEX II 1/2G All versions without cooling neck,
Ex ia IIC T4/T6 with DIN connector and output
Ga/Gb
signal code A1
ATEX II 1G All versions with cooling neck,
Ex ia IIC T3/T4/T6 Ga output signal code A1 and without
DIN connector
ATEX II 1/2G All versions with cooling neck,
Ex ia IIC T3/T4/T6 DIN connector and output signal
Ga/Gb code A1
ATEX II 1D All versions with output signal
Ex ia IIIC T107°C code A1
IP6X Da
Barrier data Ui ≤ 30 V
Ii ≤ 100 mA
Pi ≤ 750 mW
Capacity Ci ≤ 31 nF
CCable ≤ 0.12 nF/m
Inductivity Li ≤ 3 μH
LCable ≤ 1.1 μH/m
Temperature class T1 ... T3: -40 <Tamb < 45/70/75/85 °C
(ambient temperature) T1 ... T4: -40 <T < 85 °C
amb
T1 ... T6: -40 <Tamb < 70 °C
Temperature class T1 ... T3: -40 <Tmed < 130/150/160/170/200 °C
(medium temperature) T1 ... T4: -40 <T < 115/130 °C
med
T1 ... T6: -40 <Tmed < 75/80 °C
For the application in Ex zone you have to respect the conditions
mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX
0129).
You find the certificates and manuals under http://www.baumer.com/

Measuring ranges and overpressure safety

Pressure in bar
Pressure 0 ... 0.1 -0.1 ... 0.1 0 ... 1.6 0 ... 6 0 ... 25 0 ... 40 0 ... 100 -1 ... 399
range 0 ... 0.16 -0.2 ... 0.2 0 ... 2 0 ... 10 -1 ... 24 -1 ... 39 0 ... 400
0 ... 0.25 0 ... 0.4 0 ... 2.5 -1 ... 9
Design and specifications subject to change without notice

0 ... 0.6 -1 ... 1.5 0 ... 16


0 ... 1 0 ... 4 -1 ... 15
-1 ... 0 -1 ... 3 0 ... 20
-1 ... 0.6 -1 ... 5
Over 1 3 15 60 70 135 400 690
pressure
Burst 2 6 30 120 140 270 800 1350
pressure
2013-04-16

www.baumer.com Data sheet A11.35 Page 2 / 4


PBMN
flush

Electrical connections

Signal
Signal at 4...20 mA /atSignal
4...20 at
mA / Signal at 0...10 V
0...10V

M12 Connector n.c. / +VOUT


4-pins DIN 43650
3
n.c. / +VOUT IOUT / GND
IOUT / GND 2 1
+VS / +VS
4 3
1 2
+VS / +VS n.c. / +VOUT

earth earth

Cable Field housing


output
Not included in delivery
(Red) / +VS / +VS clamping range: 8...10 mm
n.c. / +VOUT
4
(Blue) / IOUT / GND 3
IOUT / GND 2
(White) / n.c. / +VOUT 1
+VS / +VS
(Shield) / earth
(Shield) / earth

Dimensions (mm)

Field Housing, Cable gland


EN 175301-803A (DIN43650 A) stainless steel, IP67
4 pins, IP65

Shielded cable
(1,5 m), IP67
ø8..10

M12 4 pins, ø 6,3


IP67
94
59,1
52

ø 54,5

ø 22 ø 22 ø 22 ø 22

Code 14 Code 44 Code 53 Code 54


Design and specifications subject to change without notice
45,3

Code 41 Code 42 Code 46 Code 43 Code 44


LCN
33

39

39

43
2,5
16

51
22,3

20,5

20,5
10
9

27

ø 17,5
9

G 1/2 A ø 15,5 ø 18 f7 ø 30
G 1/2 B G 1/2 B G1 ø 25,5
G 1/2" A Flush
DIN3852 G 1/2" Flush G1
G 1/2" Flush G 1" Flush
(HEX 27) Cone (40°) G 1" Flush Cone
O-Ring at the front O-Ring at the front
(HEX 27) (40°, HEX 41)
(HEX 27) (HEX 41)

Cooling Code 71 Code 73 Code 74


Neck LCN = 77 mm N/A N/A 81 mm 89 mm
2013-04-16

www.baumer.com Data sheet A11.35 Page 3 / 4


PBMN
flush

Ordering details PBMN flush

PBMN – 2 . x . xxx . x . xx . xx . xx . x . x . x .
Model
Pressure transmitter PBMN

Housing material
Stainless steel 1.4404 AISI 316L 2
.
Accuracy
0.5% FS 3
0.25% FS 4
0.10% FS P > 250 mbar 5
.
Pressure range and unit in bar
-0.1...0.1 Only pressure type relative B2H
-0.2...0.2 Only pressure type relative B4G
-1...0 Only pressure type relative B59
-1...0.6 Only pressure type relative B72
-1...1.5 Only pressure type relative B74
-1...3 Only pressure type relative B76
-1...5 Only pressure type relative B77
-1...9 Only pressure type relative B79
-1...15 Only pressure type relative B81
-1...24 Only pressure type relative B82
-1...39 Only pressure type relative B1L
0...0.1 Only pressure type relative B08
0...0.16 Only pressure type relative B09
0...0.25 Only pressure type relative B10
0...0.4 B11
0...0.6 B12
0...1 B15
0...1.6 B16
0...2 B17
0...2.5 B18
0...4 B19
0...6 B20
0...10 B22
0...16 B24
0...20 B25
0...25 B26
0...40 B27
0...100 B31
0...400 B38
.
Kind of pressure
Relative R
Absolute A
.
Output signal
4...20mA A1
0...10V A2
.
Output connection
M12, 4 pins 14
DIN 43650, 4 pins 44
Shielded cable (1.5 m) 53
Fiel housing 54
.
Process connection
G½" A flush DIN3852 41
G½" flush, cone 42
G½" flush, o-ring at the front 46
G1" flush, o-ring at the front P ≤ 40 bar 43
G1" flush, cone P ≤ 40 bar 44
G½" A flush DIN3852 with cooling neck 71
G1" flush, o-ring at the front with cooling neck P ≤ 40 bar 73
G1" flush, cone with cooling neck cooling neck P ≤ 40 bar 74
Design and specifications subject to change without notice

.
Process connection material
Stainless steel 1.4404 AISI 316L 2
Hastelloy-C H
.
Sealing
NBR 1
EPDM 2
FKM (Viton®) 3
.
Oil filling
Silicon oil 1
FDA approved white oil T ≥ -10°C 2
.
Display
Without 0
ATEX
Without 0
ATEX according to SEV 11 ATEX 0129 In combination with output signal code A1 1
Approval
None 0
Downscale
Without downscale
2013-04-16

With downscale S0x

www.baumer.com Data sheet A11.35 Page 4 / 4