You are on page 1of 5

Advanced 128

PRODUCT DATA
Supria 16 Slice CT Puts You On The Path of High Solid Capabilities
Quality, Cost-Effective CT Scanning Are Built Into the Supria

Hitachi’s Supria CT comes equipped with a robust set of features and functions that enable lower dose and faster
Addressing the challenges of controlling workflow with high quality imaging across a wide range of clinical applications.
Supria Advantage
healthcare organization costs effectively •

Meets and surpasses Smart Dose Standard XR-29
Intelli IP Advanced – Hitachi’s powerful iterative reconstruction
technology, a standard feature of Supria
• Compact design fits into as little as 250sq. ft.
is at the core of Hitachi technology.
Scan Parameters
•• Rotation speeds: 0.75, 1.0, 1.5, 2.0 sec.
The Supria CT is the latest in a family of •• Data collection speed: 1,200 views per second
•• Minimum sice thickness: 0.625mm
•• FOV: 20-500mm
Hitachi CT Solutions providing superb •• Max scan range 71in/1800mm
•• Max scan rotations: 100
•• Volume scan pitch: 0.56 to 1.56
image quality, dependability, reliability and
Scan Acquisition Types
•• S canogram with real-time display: AP & Lateral
support Hitachi is known for – at a lower •• Normal scan: Axial Mode
•• Volume scan: Helical Mode
•• Dynamic scan mode: Time Density Analysis
cost of ownership.
Protocols*
•• Pre-programmed emergency
•• Pre-programmed normal
•• Pre-programmed user default
•• Limitless user-defined, customizable protocols
•• Access Controls (locked protocols, XR-26)

Image Quality**
•• Spatial resolution: 17.2 lp/cm @ 0% MTF, 50mm FOV
•• Contrast resolution: 2.5mm @ 0.25%, 160mm FOV

* All Hitachi protocols provided are reviewed and optimized by


HMSA’s Protocol Committee to ensure ALARA practices are met.

** With Hitachi Performance Phantom.


Compact Design with Enhanced Patient Access Chest Abdomen Orthopedic

and Comfort Define the Supria CT

75cm

47.5cm

Hitachi’s patient centric design delivers on comfort and


ease-of-access, culminating an optimal patient experience. Simple User Interface
Gantry Operator’s Console Image Processing
Enhancing positioning ease and Technologist interaction with the patient, From acquisition and reconstruction through post-processing, the operating •• Multi-Planar Reconstruction (MPR)
the Supria includes an information display on the Gantry face to easily control console clearly displays all the information on one monitor. For enhanced •• Maximum Intensity Projection (MIP)
positioning and set-up functions from table-side. efficiency, the software team at Hitachi incorporated a quick-entry mode to •• Minimum Intensity Projection (MinIP)
minimize action steps. •• Surface Rendering
•• Gantry aperture: 75cm
•• 3D Volume Rendering
•• Gantry tilt: ± 30 degrees •• Display: single 24-inch LCD widescreen monitor
•• Auto MPR, automatic MPR Processing
•• Gantry Display: Digital display of gantry tilt angle and table postiion X-ray Generator •• Display resolution: 1920 x 1200
selected from Scanogram
•• Scan localizer: Laser marker Integrated with the performance characteristics of the high-heat unit •• Fully automated, interactive software platform
•• Exam-Split
(at preparatory position and scan position) X-ray tube, the generator delivers the optimal X-ray power per protocol. •• Pre-programmed patient demographics and protocol selection
•• Gantry, table controls: emergency stop, •• Complete protocol-driven scan control
•• Type: High-frequency inverter control Network Capability
start/stop scan, home, preset, move to scan •• Auto-archive
•• Output: 48kW •• IHE-SWF
plane, table reset, tilt, laser alignment lights, demo breath hold •• Auto-film
•• kVp selection: 80, 100, 120, 140kV •• DICOM Modality Worklist
buttons/lights, table in/out, table up/down, collision sensor •• UPS for console and image processor
•• mA selection: 10–400mA (5mA steps) •• DICOM MPPS
•• Foot pedal controls: home, preset •• Max tube current: 400mA (≤120kV), 340mA (140kV) •• DICOM Query/Retrieve (optional)
•• Breathing lights Patient Registration
•• Patient communication: intercom, auto-voice •• Pre-registration
Patient Table Computer Processing
•• Emergency registration mode
The high-weight-capacity table accommodates a wide variety of patients •• OS – Windows 7 Embedded (64 bit)
X-ray Detector without compromising patient comfort or access. And the low minimum •• CPU – Intel Core3- 3GHz
•• Type: Solid state ceramic table elevation facilitates placement of disabled and elderly patients. Image Reconstruction •• Main Memory – 8GB
•• Anatomical coverage per rotation: 2cm •• Slice thickness: 0.625 –10mm
•• Detector elements: 28,160 (32 x 880) •• Table-top width: 19in (475mm) •• FOV: 20 – 500mm, by 1mm steps
•• Detector output: 880 channels x 16 rows •• Table length: 106in (2688mm) •• Matrix: 512 x 512
Storage Capacity
•• Table weight capacity: 500 lbs. (227kgs) •• Images: 110 GB holds 200,000 images
•• Image reconstruction time: up to 10 images/second
•• Horizontal accuracy: ±0.25mm •• Raw data: 200GB holds >6,000 scans
X-ray Tube •• Vertical travel range: 18in (450mm) to 39in (1000mm)
(depending on recon parameters)
•• Archive: 9.4 GB DVD (non-cartridge) holds approximately
Supria’s X-ray tube is highly durable and provides the power needed for larger •• Immediate image review
•• Tabletop travel: from 5mm/sec to 150mm/sec 16,000 images
patients and long-term image quality. A tube chiller is not required, enhancing •• CT number range: -32,768 to +32,767
•• Horizontal travel range: 75in (1910mm) •• Also accepts CD-R and DVD-R
system reliability and simplifying the installation process. And Interscan times
are minimized with a fast tube-cooling rate – helping promote faster scanning Image Display and Analysis
and throughput. •• Up to 1024 x 1024 Matrix
Remote Service
•• Sentinel™ diagnostic tools
•• Anode heat capacity: 5.0MHU •• Multi-frame layout
•• WW/WL
•• Anode max. cooling rate: 748kHU/min
•• Magnify
TeraRecon Server Solutions
•• Tube cooling: Oil/Air To enhance clinical applications and workflow capabilities Hitachi offers
•• Focal Spot (mm): 0.7 x 0.8; 1.2 x 1.4 •• Pan
a range of optional 3D visualization solutions through a partnership with
•• ROI
TeraRecon, Inc. which can deliver advanced clinical analysis capabilities
•• Image Rotation
to multiple thin-client users – simultaneously.
•• Measurement
•• Cine
•• Edge Enhancement/Smoothing
Supria Includes Powerful Technologies Efficient and Cost Effective Siting

Surpassing the feature-set required by the Predict Scan


MITA Smart Dose Standard (XR-29), Supria Monitors contrast uptake to a user-selectable threshold value and
automatically initiates the scan for optimized image contrast at a
integrates leading edge technology that lower radiation dose and reduced injected contrast volume.
puts the focus on patient dose reduction*
and exam dose reporting. Reduced kV Imaging
Allows selection of lowest appropriate kV for the individual patients’
Automatic Exposure Control – Intelli EC size – supports scanning at:
Hitachi’s proprietary 3D mA modulation technology, Intelli EC automatically •• 80kV
modulates mA to lower individual patient dose levels depending on patient •• 100kV
anatomy and size. •• 120kV
•• 140kV
Pediatric and Adult Reference Protocols
Separate pre-loaded protocols for Pediatric and Adult patients ensures that
doses are tailored to lower levels for Pediatric patients who are more dose
sensitive and need the greatest attention to reducing radiation risks.

CT Dose Check A Typical Floor Plan – 342 sq. ft. A Minimum Floor Plan – 265 sq. ft.
Notifies the operator during the patient’s exam protocol set-up (and adjustment)
if the dose levels resulting will exceed predetermined reference dose levels.
(Complies with NEMA Standard XR-25) The compact footprint of Supria fits most existing rooms.
So whether you are replacing a CT or expanding your imaging
DICOM Dose Structured Reporting (Dose SR) capabilities, Supria will fit your specifications.
Creates DICOM Standard format dose report for each Supria patient examination
and enables submission of reports to your PACS and/or national or other dose
registries. Physical Specifications
Simple Dose Report Height(mm) Depth(mm) Width(mm) Weight in Kg
Power and Environmental Requirements
Provides dose reporting information as a DICOM image making it easily
accessible to review dose information as part of an image series. Gantry 1843 920 1600 1600 •• Voltage: 208 VAC, ±10% or less
•• Main breaker: 200 AMP service
Patient Table 450-1000 2262 577 324 •• Peak power capacity: 75kVA. Regulation 5% or less
Intelli IP Advanced •• Input frequency: 50/60Hz
Intelli IP Advanced is Hitachi’s latest proprietary processing engine that makes use Operator’s •• Operating temperature: 20 – 28 degree C
of adaptive iterative reconstruction processes in both projection and image space. Console 660 745 400 76 •• Operating humidity: 35 – 80%
Its use will reduce pixel noise at a given level of mAs as compared to filtered
backprojection without Intelli IP Advanced.
Table for monitor, keyboard and mouse supplied by HMSA.
* In clinical use, dose saving features may reduce CT patient dose depending on the
clinical task, patient size, anatomical location and clinical practices employed. Consultation
with a radiologist and physicist are recommended to determine the appropriate dose
needed to obtain diagnostic image quality for a particular clinical task.
Hitachi Medical Systems America, Inc.
1959 Summit Commerce Park
Twinsburg, Ohio 44087 USA
Tel: 330.425.1313 800.800.3106
Fax: 330.425.1410
www.hitachimed.com

Hitachi Medical Corporation


4-14-1 Akihabara UDX
Soto-Kanda, Chiyoda-ku
Tokyo, 101-0021 Japan
www.hitachi-medical.co.jp © 2015 Hitachi Medical Systems America, Inc.

1115/3000/DM#106005-V2
Printed in U.S.A.

Hitachi reserves the right to change specifications described herein


Follow us on:
without prior notice. This document provides general technical
LinkedIn: www.linkedin.com/company descriptions of both optional and standard features.
/hitachi-medical-systems-america

Twitter: @Hitachi_Health