Professional Documents
Culture Documents
CONCLUSION
Rx Level (dB) from Service Antenna at 15.00 m from Service Antenna
19
70
-65
7
40
3.20
0
65
3.80
0.0024
A-LG-1 A-LM-1
3.80 3.80
10 10
5 5
15 15
-1.2 -1.2
-1 -1
0 0
1 1
-2.2 -2.2
7 7
8.6 8.6
15.00 15.00
62.0 62.0
-53.4 -53.4
Loss/Gai
Particulars n A-LG-1 A-LM-1
MS Output Power 30 30
Propogation loss b/n antenna & MS for n=4 environment 84.55 84.55
Indoor Omni antenna gain 3
Indoor Pannel antenna gain 7 1 1
EIRP at indoor antenna -47.55 -47.55
Total length of 1/2" corrugated coaxial cable in mtrs 0.08 15 15
Total length of 7/8" corrugated coaxial cable in mtr. 0.58
1M jumper loss 0.5 1 1
Total Cable loss 1.7 1.7
2 way broad band Splitter(loss at each O/P port) 3.25 1 1
3 way broad band Splitter(loss at each O/P port) 4.8
4 way broad band Splitter(loss at each O/P port) 6
Total Splitter Losses 3.25 3.25
7dB Broad band coupler(Through port loss) 1 0 0
7dB Broad band coupler(Attn port loss) 7 0 0
Total Coupler Loss 0 0
Signal level at Repeater -52.5 -52.5
Gain of the Repeater 65 65
Repeater O/P Power in uplink in dBm 12.5 12.5