Product Overview
1
2
Find out today what will not happen tomorrow
Reporting critical operating states today, so that unwanted inci- methods and design. Along with precise measurement
dents such as operational interruptions, costly material damage technology, the ISOMETERs® provide many functions for early
or even physical injuries do not happen. detection and quality assurance with user-friendly and intuitive
operation, reliable evaluation and simple communication.
Safety of power supply
To ensure electrical safety for people and electrical installations Fast localisation of insulation faults
in an efficient way on a long-term basis, Bender offers insulation Bender insulation fault location systems enable fast localisation
monitoring devices for all the key industries. In particular, and elimination of insulation faults even during operation.
these devices are used anywhere where a safe power supply is Disconnection of the electrical installation is not required.
an essential requirement to prevent system failures, eliminate Portable Bender solutions facilitate the use in large installations
the risk of serious or fatal injuries and to avoid material with sub-distributions.
damage.
For more than 70 years, Bender has been a name for advanced
Top-level productivity and maximum safety for technology using the latest „Made in Germany“ measurement
people and the electrical installation technology and outstanding technical expertise. Because of
With Bender insulation monitoring devices for unearthed this, Bender offers an exceptionally long warranty period of
power supplies (IT systems) you are already using the tech- five years.
nology of tomorrow with respect to reliability, measurement
Contents
■■ Unearthed power supply systems................................................. 4 ■■ Insulation fault location systems EDS............................26
■■ IT systems – information ahead of time....................................... 5 – Insulation monitoring devices with
■■ Insulation monitoring devices ISOMETER® locating current injector..............................................................27
– High system availability in main circuits.................................. 6 – Insulation fault locators ISOSCAN®..........................................28
– Control and auxiliary circuits......................................................10 – Insulation fault locators with
– Main circuits.....................................................................................12 integrated transformer.................................................................31
– Specific applications......................................................................14 – Portable equipment for insulation fault location...............32
■■ Communication solutions..............................................................34
■■ Accessories
■■ Retrofit...................................................................................................36
– Coupling devices............................................................................22
■■ POWERSCOUT®...................................................................................37
– Measuring instruments................................................................23
■■ Support during all phases...............................................................38
– Gateways...........................................................................................24
3
For a high level of operational and electrical system safety:
Unearthed power supply systems (IT systems)
4
IT systems - information ahead of time
ISOMETER®s in IT systems are an effective means of damage prevention, they enable increased productivity and optimised
maintenance, which in turn lead to considerable reduction in costs. Bender's wide range of products allows the implementation
of individual safety solutions and safeguards your investment.
Optimised maintenance
■■ Recognise and signal insulation deteriorations early
■■ Localising faulty circuits automatically
■■ Optimising the planning of time and personnel resources
■■ Displaying information about the status of the electrical installation at a central location
■■ Remote diagnosis via Internet/Ethernet
ON
■■ No interruption to operation in the event of a phase-to-earth fault
■■ No control malfunction in the event of insulation faults
■■ Electrical installations are kept at a high level of availability
■■ Monitoring electrical installations also during standstill
5
High system availability in main circuits
Main circuits
3(N)AC
Voltage system
AC
AC/DC
DC
AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V
Nominal system voltage Un offline
DC 0…1000 V DC 0…1000 V DC 0…1000 V (60 Hz)
Tolerance of Un + 15 % + 15 % + 15 % + 15 %
Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation
Screw mounting
Panel mounting/
wall fastening
Web server
Interfaces
6
Ordering information
Supply voltage US Nominal system voltage Un Panel mounting Option W 1) Type Art. No.
– iso685-D B91067010
–
-40…+70°C, 3K5, 3M7 iso685W-D1) B91067010W
– iso685-S + FP200 B91067210
-40…+70°C, 3K5, 3M7 iso685W-S + FP200W1) B91067210W
– iso685-D-B B91067020
–
AC, 3(N)AC 0…690 V; 1…460 Hz/ -40…+70°C, 3K5, 3M7 iso685W-D-B1) B91067020W
DC 0…1000 V – iso685-S-B + FP200 B91067220
AC 24…240 V; 50…400 Hz/
DC 24…240 V -40…+70°C, 3K5, 3M7 iso685W-S-B + FP200W1) B91067220W
– iso685-D-P B91067030
–
-40…+70 °C, 3K5, 3M7 iso685W-D-P1) B91067030W
– iso685-S-P + FP200 B91067230
-40…+70 °C, 3K5, 3M7 iso685W-S-P + FP200W1) B91067230W
AC, 3(N)AC 0…690 V (60 Hz) – isoNAV685-D B91067014
–
offline – isoNAV685-D-B B91067024
1)
Increased shock and vibration resistance 3K5 and 3M7.
Example applications
IT system 1 IT system 2
PE PE
Ethernet
COM465
7
High system availability in main circuits
Equipment for
Special applications
insulation fault location
Control circuits
Circuits
Main circuits
3(N)AC
Voltage system
AC
AC/DC
DC
Tolerance of Un + 15 % + 15 % + 15 %
System leakage capacitance Ce ≤ 500 µF ≤ 500 µF ≤ 500 (150) µF
Response value Ran 1 kΩ…1 MΩ 1 kΩ…1 MΩ 1 kΩ…1 MΩ
Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation
Screw mounting
Panel mounting/
wall fastening
Interfaces – BMS
Ordering information
applicable for coupled IT systems Nominal system voltage Un Supply voltage US Type Art. No.
COM465
Coupled IT systems
9
Maximum operational safety in
control and auxiliary circuits
Control circuits
Circuits
Main circuits – – –
3(N)AC – – –
Voltage system
AC
AC/DC –
DC –
AC 19,2…265 V,
Nominal system voltage Un AC 0…300 V AC/DC 0…300 V
DC 19,2…308 V
Frequency range fn AC 42…460 Hz DC, 42…460 Hz DC, AC 15…460 Hz
System leakage capacitance Ce µF ≤ 20 µF ≤ 10 µF ≤ 20 µF
Response value Ran kΩ 1…200 kΩ 10…200 kΩ 1…200 kΩ
Alarm contacts 2 changeover contacts 1 changeover contact 2 changeover contacts
Response value
Operating principle N/O or N/C operation N/C operation N/O or N/C operation
Response time tan
≤1s ≤6s ≤2s
(at RF = 0.5 x Ran and Ce = 1 µF)
Start-up delay t 0…10 s – 0…10 s
Response delay ton 0…99 s – 0…99 s
LC display –
Indication
Power On LED
Alarm LEDs
DIN rail
Installa-
tion
Screw mounting
Ordering information
Accessories
Type designation Art. No.
Mounting clip for screw mounting (1 piece per device) B 9806 0008
10
In localised areas, such as machine control systems or safety lighting where space is limited, control and auxiliary circuits provide
additional functions, such as command output, interlocking, messaging and measuring. For these circuits, particular emphasis is
placed on operational reliability.
Example applications
11
High system availability in main circuits
Control circuits – –
Circuits
Main circuits
3(N)AC
Voltage system
AC
AC/DC – –
DC – –
AC 0…1000 V/ AC 0…1000 V/
Nominal system voltage Un AC, 3(N)AC 0…793 V 1) AC, 3(N)AC 0…793 V 1)
DC 0…1500 V DC 0…1500 V
Frequency range fn AC 40…460 Hz AC 40…460 Hz DC 0,1…460 Hz DC 0,1…460 Hz
System leakage capacitance Ce µF ≤ 20 µF ≤ 20 µF ≤ 500 μF ≤ 2000 μF
Nominal voltage range Un
expandable AGH204S-4/AGH520S AGH204S-4/AGH520S – –
(via coupling devices)
10…100 kΩ
Response value Ran kΩ 1…200 kΩ 200 Ω…1 MΩ 200 Ω…1 MΩ
35…500 kΩ
LC display – – –
Communication
Power On LED
Alarm LEDs
RS-485 interface – –
DIN rail – –
Installation
Screw mounting
Panel mounting/wall
– – – –
fastening
Ordering information
Absolute values
1)
12
Main circuits provide the power supply for electrical installations or buildings. These circuits include equipment for generating,
converting, distributing, switching and consuming electrical energy. From the user's point of view, different types of loads should
be distinguished between: pure AC loads (e.g. motors), AC/DC loads containing electronic components (e.g. converters) and pure
DC loads (e.g. battery systems).
Example applications
13
Recognising faults at an early stage
in specific applications
AC, DC or AC/DC
medium voltage Medical locations Photovoltaic
systems
Control circuits – – – – – – –
Circuits
Main circuits
3(N)AC – – –
Voltage system
AC – –
AC/DC – – – –
DC – –
via AGH-PV
AC, 3(N)AC/DC AC 230 V DC 0…1100 V,
Nominal system voltage Un AC 70…264 V 1) 3(N)AC 0…793 V DC 0…1500 V DC 0…1500 V
0…15,5 kV AC 127 V AC 0…793 V 1)
DC 0…1100 V 1)
via AGH-PV via AGH420
Frequency range fn DC, AC 0,2…460 Hz AC 47…63 Hz AC 50…60 Hz DC DC
DC, 10…460 Hz DC, 10…460 Hz
System leakage capacitance Ce ≤ 5 µF ≤ 5 µF ≤ 5 µF ≤ 2000 µF ≤ 500 µF ≤ 2000 µF ≤ 2000 µF
Response value Ran kΩ 100 kΩ…10 MΩ 50…500 kΩ 50…500 kΩ 0,2…100 kΩ 1…490 kΩ 200 Ω…1 MΩ 200 Ω…1 MΩ
LC display – –
Power On LED – –
Alarm LEDs
Indication
RS-485 interface
BMS
RS-485 interface
– – – – – –
MODBUS
CAN – – – – –
DIN rail – –
Installa-
tion
Screw mounting
Ordering information
Example applications
Rf Rf
Rf
Ce <2000µF
PV generator unearthed (IT system) with nominal voltage ≤ DC 1100 V and ISOMETER® isoPV with coupling device AGH-PV
15
Specific applications
ISOMETER® isoLR275 ISOMETER® IR470LY2-60 ISOMETER® IR420-D6 ISOMETER® IR423 ISOMETER® IR123
Control circuits – – – – –
Circuits
Main circuits
3(N)AC – –
Voltage system
AC
AC/DC – – – –
DC – – –
via AGH-LR
AC, 3(N)AC
Nominal system voltage Un 3(N)AC 0…793 V Offline AC 0…300 V AC 100…300 V
0…793 V 1)
DC 0…1100 V 1)
via AGH-LR via AGH520S,
Frequency range fn AC 40…460 Hz AC 30…460 Hz AC 22…460 Hz
DC, 10…460 Hz AGH676S-4
System leakage capacitance Ce µF ≤ 500 µF ≤ 10 µF ≤ 10 µF ≤ 5 µF ≤ 1 µF
10…1000
Response value Ran kΩ 0.2…100 100…10000 1…200 46/23
500…5000
LC display – –
Power On LED – –
Indication
Alarm LEDs –
RS-485 interface – – – –
PWM output – – – –
DIN rail –
Installa-
tion
Screw mounting
Example applications
isoLR275-327 + AGH-LR-3
DC 19.2…72 V consisting of: B 9106 5702W
isoLR275-327 (B 9106 5700W), AGH-LR-3 (B 9803 9022W)
AC 0…793 V, DC 0…1100 V
isoLR275-335 + AGH-LR-3
AC 88…264 V, DC 77…286 V consisting of: B 9106 5703W
isoLR275-335 (B 9106 5701W), AGH-LR-3 (B 9803 9022W)
AC 230 V IR470LY2-60 B 9104 8010
AC 90…132 V1) IR470LY2-6013 B 9104 8013
AC 0…793 V
AC 400 V IR470LY2-6015 B 9104 8009
DC 9.6…84 V1) IR470LY2-6021 B 9104 8014
AC 16…72 V, 42…460 Hz/DC 9.6…94 V IR420-D6-1 B 7101 6415
– IR420-D6-2 B 7101 6407
AC 70…300 V, 42…460 Hz/DC 70…300 V
IR420-D64-2 B 7101 6408
AC 16…72 V, 30…460 Hz/DC 9.6…94 V IR423-D4-1 B 7101 6304
AC/DC 70…300 V, 30…460 Hz IR423-D4-2 B 7101 6305
AC 0…300 V
AC 16…72 V, 30…460 Hz/DC 9.6…94 V IR423-D4W-1 B 7101 6304W
AC/DC 70…300 V, 30…460 Hz IR423-D4W-2 B 7101 6305W
AC 100…300 V, 22…460 Hz US = Un IR123P-4-2 B 9101 6308
1)
Absolute values
Elektromobilität
Control circuits – – –
Circuits
Main circuits
3(N)AC – – –
Voltage system
AC – – –
AC/DC – – –
DC
DC 0…1000 V
Nominal system voltage Un DC 0…1000 V DC 0…600 V
AC 0…690 V, 15…460 Hz
+ 10 %
Frequency range fn +0% + 15 %
+ 15 %
System leakage capacitance Ce ≤ 1 µF ≤ 5 µF ≤ 1 µF
30 kΩ…1 MΩ;
Response value Ran 100…10000 kΩ 10…990 kΩ
40 kΩ…2 MΩ
DIN rail
Installa-
– –
tion
Screw mounting
Interface
Modbus – RTU –
BMS – –
Ordering information
18
Example applications
Vehicle
Charger
coupler iso-F1
HV DC Circuit
AC
IMD
vehicle
L1
L2
L3 RCD required
N by IEC 60364
Mode 4 IT system
PEN
PE
Load Switch
DC contactor RESS
F F Inverter
DC+ DC + F V = M
DC - F
F L
RB I∆n DC ≥ 6 mA (Option)
DC-
RCD
Isolating = Air condition
PFC
type A other
transformer IMD = consumers
Earthing Control CP N
CP AC on-board
at the source Pilot
CP Control Pilot
charger
Function
Function
PE PP
with electrical IMD 14 V on-board
separation
(Option)
RPE PE power system
= (electrical
Note:
RA Earthing in the Only one IMD may separated)
distribution be active in each
interconnected IT system © www.bender-de.com Electrical Chassis / Protective equipotential bonding
RAE
RTyre
19
Specific applications
Control circuits –
Circuits
Main circuits
3(N)AC
Voltage system
AC
AC/DC
DC
Nominal system voltage Un AC/DC 0…400 V AC, 3(N)AC 0…690 V, DC 0…1000 V
Frequency range fn + 25 % + 15 %
System leakage capacitance Ce ≤ 300 ≤ 1000
Response value Ran 1…990 1…10000
DIN rail
Installa-
tion
Screw mounting
Web server –
Modbus RTU TCP
Interface
BCOM –
BS –
BMS –
Ordering information
System leakage
Nominal system voltage Un Supply voltage 1) US Type Art. No.
capacitance Ce
3(N)AC, AC/DC 0…400 V AC 100…240 V/DC 24…240 V < 300 µF isoRW425-D4W-4 B71037000W2)
AC 0…690 V, 1…460 Hz/DC 0…1000 V AC 24…240 V, 50…400 Hz/DC 24…240 V ≤ 1000 isoRW685W-D B91067012W
1)
Absolute values
2)
Device version with screw terminal on request.
20
Application example
IT system
IT system
S1
S1
K1 S2 S3
ISOMETER®
isoRW425 K1 S2 S3
ISOMETER®
isoRW425
Emergency lighting
Electrical brakes Distribution Lorem
M ipsum
Emergency lighting
Door control AC+DC
Distribution M M
Electrical brakes
Air conditioning loads
AC+DC IMD
Door control M
Air conditioning loads
Lorem ipsum
Auxiliary circuits
IMD
IMD
3AC 400 V, 50/60 Hz
Auxiliary circuits IMD
Supply of coaches (train)
G 3AC 400 V, 50/60 Hz
3~ Supply of coaches (train)
G
3~
G M M M M
3~ 3~ 3~ 3~ 3~
Universal use of the isoRW685 for IT systems > 400 V
AC overhead lines e.g. 15 kV, 16.7 Hz
Emergency lighting
Electrical brakes Distribution Auxiliary circuits
AC+DC 3(N)AC 380 V
Door control IMD
loads 50/60 Hz
Air conditioning
Emergency lighting IT system
Electrical brakes Distribution Auxiliary circuits
AC+DC Supply of coaches 3(N)AC 380 V
Door control IMD
IMD
Air conditioning loads E.g. 1000 V, 16.7 50/60
Hz or Hz
1500 V, 50/60 Hz
IT system
G M M
Supply of coaches M M
3~ 3~ 3~
E.g. 1000 V, 16.7 Hz or 1500 V, 50/60 Hz IMD3~ 3~
G M M M M
3~ 3~ 3~ 3~ 3~
Coupling devices
IRDH275BM – – – –
IR420-D64 – – – – –
iso685-D – –
iso685-S – –
Ordering information
22
Measuring instruments
IRDH275/375 – –
IRDH275B/375B –
IRDH575 –
iso685…
Ordering information
Midscale
Scale Input current Dimensions Type Art. No.
(SKMP)
23
Accessories
Gateways
Condition Monitor/
Application BMS-Modbus RTU-Gateway Condition Monitor/Gateway Condition Monitor/Gateway
PROFIBUS-Gateway
Protocol input BMS BMS/Modbus RTU/TCP BMS/Modbus RTU/TCP BMS/Modbus RTU/TCP
Ethernet/Modbus TCP,
Protocol output Modbus RTU Ethernet/Modbus TCP Ethernet/Modbus TCP
PROFIBUS DP
Indication LCD/LED LED LED 7“-Farb-LCD
Alarm messages 1, 2)
1, 2)
1, 2, 3)
Measured values 1, 2)
1, 2)
1, 2, 3)
Device parameter
1)
1)
1)
setting
Alarm list 1)
1)
1, 3)
Functions
History memory 1)
1)
1)
Diagrams 1)
1)
1, 3)
Visualisation 1)
1)
1)
E-mail notification 1, 4)
1, 4)
1, 4)
Device tests 1, 2)
1, 2)
1, 2)
PEM… and
1)
1)
1)
energy meter support
SNMP 1)
1)
1)
Data logger 1)
1)
1)
AC/DC 76…276 V DC 24 V
DC 24V DC 24V
System
Browser Internet Explorer, Chrome, Firefox etc. Internet Explorer, Chrome, Firefox etc. Internet Explorer, Chrome, Firefox etc.
1)
Available functions on the web server – Accessible by means of a PC using a browser
2)
Available via protocol
3)
On the device‘s own LC display
4)
TLS/SSL support
24
Ordering information
Funktionsmodul
Anwendung Art.-Nr.
(Software-Lizenz)
25
Insulation monitoring devices ISOMETER®
with locating current injectors
Auxiliary circuits
Main circuits
Un (B1)
Un (B1)
3AC/AC 20…150 V/DC 20…150 V
3AC/AC 20…575 V
(Version IRDH575B1-4227,
AC, 3(N)AC 0…690 V, DC 20…575 V (B1-Version)
Nominal system voltage Un IRDH575B1-4235) AC 70…230 V
DC 0…1000 V
Un (B2)
Un (B2)
3AC/AC 340…760 V
–
DC 340…575 V (B2-Version)
Tolerance of Un + 15 % + 15 % + 15 % + 15 %
System leakage capacitance Ce µF ≤ 1000 ≤ 500 (150) ≤ 500 (150) ≤5
Response value Ran kΩ 1…10000 kΩ 1…10000 kΩ 1…10000 kΩ 50…500 kΩ
Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation
Screw mounting
Panel mounting/
wall fastening
Web server
Modbus TCP
Interfaces
BCOM
BS
BMS
Ordering information
2)
Device „Option-W“ with increased shock and vibration resistance : Indicated by the letter „W“ at the end of the order number.
26
Insulation fault location system EDS
They are operated/used for main and control circuits in, for example:
■■ Power stations ■■ Paper industry
■■ Hospitals ■■ Oil and natural gas industry
■■ Shipbuilding ■■ Mining, open-cast mining
■■ Traffic engineering ■■ Rolling mills
■■ Industrial plants ■■ Mechanical engineering
Application example
ISOMETER®
iso685-D-P
BS
EDS44...-L EDS44...-L
EDS440
EDS440
ISOSCAN®
ISOSCAN®
TEST
CHANNELS TEST
ON CHANNELS
ON
1 2 3 4 5 6
COM 1 2 3 4 5 6
RESET COM
7 8 9 10 11 12 RESET
SERVICE 7 8 9 10 11 12
SERVICE
ALARM I∆ L SLAVE ADDRESS
MUTE ALARM I∆ L SLAVE ADDRESS
MUTE
ALARM I∆ n
ALARM I∆ n
COM465
P591SDE
®
NACSOSI
EDS440
ISOSCAN®
TEST
CHANNELS
ON
1 2 3 4 5 6
COM
7 RESET
8 9 10 11 12
SERVICE
EDS195P EDS44...-L
27
Insulation fault locators ISOSCAN®
ISOSCAN® EDS440-S ISOSCAN® EDS440-L ISOSCAN® EDS441-S ISOSCAN® EDS441-L ISOSCAN® EDS441-LAB
High-resistance insulation
faults in case of high system
Special applications – – – –
leakage capacitances and low
test current value
Control circuits – –
Circuits
Main circuits – – –
3(N)AC – – –
Voltage system
AC
AC/DC
DC
see Locating current injector see Locating current injector AC 20…276 V, AC 20…276 V, AC 20…276 V,
Nominal voltage Un max
(e. g. ISOMETER® iso685-D-P) (e. g. ISOMETER® iso685-D-P) DC 20…308 V DC 20…308 V DC 20…308 V
Response value Ran kΩ acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve
LED display – –
DIN rail
Installa-
tion
Screw mounting
Interfaces BB BS BB BS BS
Bestellangaben
– EDS440-S-1 B91080201
2…10 mA
EDS440-L-4 B91080202
AC/DC 24…240 V – EDS441-S B91080204
0,2…1 mA EDS441-L-4 B91080205
EDS441-LAB-4 B91080207
28
Application example
Un
L1
L2
L3
PE
US
6A 6A
BB-Bus (2 EDS max.)
ISOSCAN®
EDS440 I L I n EDS440
EDS440 I L I I nL
ISOSCAN®
ISOSCAN®
IT-System TEST
CHANNELS
ON
ON ON
1 2 3 4 5 6
OK COM
RESET
PGH ON 7 8 9 10 11 12
>20 MΩ SERVICE
3
4
MUTE
2
6
3
5
8
1
7
2
ALARM I∆ n 7
0
1 1
8
R(an) 40kΩ/10kΩ 0
9
X1
l l
BS-Bus
29
Insulation fault locators ISOSCAN®
ISOSCAN® ISOSCAN®
EDS490-D… EDS491-D… EDS460-L… EDS461-L… EDS490-L… EDS491-L…
EDS460-D… EDS461-D…
Main circuit – – – –
Control circuit – – – –
US: DC 16…94 V,
EDS460-D-1 EDS461-L-1 EDS490-D-1 EDS490-L-1 EDS460-L-1 EDS461-L-1 EDS490-L-1 EDS491-L-1
AC 16…72 V, 42…460 Hz
US: AC/DC 70…276 V
EDS460-D-2 EDS461-L-2 EDS490-D-2 EDS490-L-2 EDS460-L-2 EDS461-L-2 EDS490-L-2 EDS491-L-2
AC 42…460 Hz
Scanning time < 10 s for up to 1080 measuring channels
Response value 2…10 mA 0.2…1 mA 2…10 mA 0.2…1 mA 2…10 mA 0.…1 mA 2…10 mA 0.2…1 mA
Residual current indication 100 mA…10 A 1) 10 mA … 1 A 100 mA…10 A 10 mA … 1 A 100 mA…10 A 10 mA … 1 A 100 mA…10 A 10 mA … 1 A
Parameter setting function –
Indication LC graphical display 7-segment display/LED indication
Error code indication
Number of measuring channels 12
Address range 1…90
Internal clock (RTC) –
History memory –
Alarm relay "Common alarm“ 2 x 1 changeover contact
Alarm relay per channel – 12 x 1 N/O contact – 12 x 1 N/O contact
Ordering information
Absolute values
1)
30
Insulation fault locators ISOSCAN®
with integrated measuring current transformers
AC
AC/DC
DC
Nominal voltage Un max – –
System leakage capacitance Ce µF acc. to characteristic curve acc. to characteristic curve
Response value Ran kΩ acc. to characteristic curve acc. to characteristic curve
DIN rail – –
Installation
Screw mounting
Panel mounting/wall fastening – –
Ordering information
31
Portable equipment for insulation fault location
Type EDS195PM
LC display 3 x 16 characters
Evaluating current IΔL 0.2…50 mA
Response value 0.2 … 1/2…10 mA selectable
Measuring clamps
32
Complete systems
EDS309… components
EDS195PM with accessories PGH18… with accessories for Measuring clamps
Aluminium case with carrying strap
Measuring clamps 52 mm
Terminal connector 4 mm
formers, optional
delivery)
EDS195P
optional
yellow
Ordering information
33
Bender monitoring systems
seamless communication
Ethernet
Modbus RTU
Modbus RTU ProfiBus-DP PEM PEM
ext. BMS bus
ATICS-4-XXXA-DIO
U1 U2 ATICS®
M
U3
I3
KNX/LON
BMS bus BMS bus BMS bus BMS bus BMS bus
ATICS-2-XXA-ISO
U1 U2 ATICS®
M
U3
I3 T IL RISO
34
COM460IP COM462RTU CP700
Condition Monitor with integrated BMS-Modbus RTU gateway for the Condition Monitor with integrated gate-
gateway for the connection of Bender connection of Bender devices with BMS way and touch screen for the connection
devices to Ethernet TCP/IP networks support using Modbus RTU of Bender devices to Ethernet TCP/IP
networks
MK800 MK2430
Universal alarm indicator and test Universal alarm indicator and test
combination for optical and acoustic combination for optical and acoustic
signalling of alarm messages from BMS signalling of alarm messages from BMS
capable Bender monitoring systems. capable Bender monitoring systems.
35
Retrofit
36
POWERSCOUT®
Find out today what won't happen tomorrow
This can be ensured, for example, by means of continuous monitoring of the Reports
installation carried out by qualified personnel. In this case, it would be smart to ■■ Historical comparisons
rely on continuous monitoring with multi-channel residual current monitoring ■■ Safe storage of measured values
systems (RCMS) and an evaluation (CP700) adapted to the system. The automatic
■■ Event and alarm statistics
POWERSCOUT® reports based on this monitoring enable the qualified person in
charge to adjust the time limits for the insulation test within the context of periodic
verification.
37
Support during all stages
Comprehensive service for your installation: remote, by phone, on site
Extension
& modernisation
Bender service
WORLDWIDE
Fault location –
made easy
Installation With portable fault location systems,
& commissioning existing insulation faults can be
Operation quickly located. They are the best
alternative if no stationary equip-
& maintenance ment for insulation fault location is
available.
From planning to modernisation – Our extensive know-how is at your disposal Bender Remote Assist
during all project phases. Bender Remote Assist offers you
support via remote access, high-
Furthermore, with our first-class service we guarantee maximum safety for quality service and advice for your
your electrical installations. challenging task consisting in
We offer services ranging from support over telephone to repairs and on-site ensuring consistent high safety in your
service – with modern measuring devices and competent employees. systems.
38
Bender. So that your world is safer.
Our world is networked on a global scale; it is digital, mobile and highly automated – whether in manufacturing
industry, inside or outside buildings, in operating theatres and power stations, in trains, underwater or underground:
it never stands still and it is more dependent than ever on a reliable and, above all, safe electrical power supply.
And exactly that is our mission: we make electricity safe. Using our technologies we ensure that electricity is
permanently available and guarantee faultless protection against the hazards of electric shock. We protect buil-
dings, plants and machinery and therefore your investments and plans. But what we primarily protect are the
lives of the people who are involved with electricity.
Hospital engineering,