Two Identical Pumps Are Configured in Series. Develop The Combined Pump H-Q Curve
Two Identical Pumps Are Configured in Series. Develop The Combined Pump H-Q Curve
ID: e20160127
Group: I4A-wRI
Solution
1. Two identical pumps are configured in series. Develop the combined pump H-Q curve.
1000
2 Pumps In series
800
600
400
200
Head…
0 E%
0 100 200 300 400 500 600
2. Two identical pumps data are configured in parallel. Determine the combined pump head
and efficiency curves.
2 Pumps in Parallel
1000
800
600
Head(m)
400 E%
200
0
0 1000 2000 3000 4000 5000 6000 7000
3. Develop the combining pump head and efficiency curve
1800
1600
1400
1200
1000
800
600
400
200
0
0 200 400 600 800 1000 1200 1400 1600