You are on page 1of 7

MAX-TEMP CTVB/CTVT

5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

Centrifugal roof mounted fans in vertical discharge format, designed for smoke extraction in fire conditions and
specially recommended for extracting smoke from the fireplaces, suitable for air stream temperature up to 120ºC and
certified F400-120 (CE marked). Base is manufactured from galvanized sheet steel and cowl is manufactured from spun
aluminium and it incorporates a bird-proof guard.
Motor
Motor is IP55, Class F and equipped with ball bearings greased for life.
Electrical supply:
Three phase 400V-50Hz.
This model is speed controllable by frequency. When is using a speed controller, the electrical installation must be
equipped with a security system which allows the maximum speed of the fans in case of fire.
Brand Soler Palau model CTVT/4/8-450 (400V50HZ) VE for an airflow 3.593 m³/h and static pressure 746 Pa.

Theoretical Working Point Performance Chart


Airflow 3.000 m³/h 1000
Static Pressure 520 Pa
Temperature 20 °C 900 Speed 1

Altitude 0m
Density 1,2 kg/m³ 800
Frequency 50 Hz

Working Point 700


Airflow 3.593 / 1.796 m³/h
Static Pressure (Pa)

Static Pressure 746 / 186 Pa 600


Dynamic pressure 23,7 / 5,93 Pa
Total Pressure 770 / 192 Pa 500
Efficiency 32
Input power 2,40 / 0,600 kW 400
Outlet speed 6,3 / 3,1 m/s
Fan speed 1400 / 700 rpm 300
Specific Fan Power 3,01 / 0,75 W/l/s Speed 2

Construction 200

Discharge diameter 450 mm


100
Fan size 450
Weight 77,00 kg
0 50Hz

Motor Characteristics 0 2000 4000 6000 8000 10000


Number of poles 4/8
Q- Airflow (m³/h)
Voltage 3-400V-50Hz
Maximum absorbed current 6,1 / 2,5 A
IP Rating IP55
Motor insulation class F Sound Performance
Drawing 63 125 250 500 1k 2k 4k 8k Overall

Inlet (LwA) 60/45 71/56 76/61 78/63 76/61 72/57 71/56 68/52 83/68

Inlet LpA @ 1m 49/34 60/45 65/50 67/52 65/50 61/46 60/45 57/41 72/57

Outlet (LwA) 60/44 72/57 76/61 79/64 78/63 74/59 69/54 63/48 84/69

Outlet LpA @ 1m 49/34 61/46 65/50 68/53 67/52 63/48 58/43 52/37 73/58

AV BV C D E F

950 741 710 500 590 14

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
1/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

Performance Chart
1000

900
Speed 1

800

700

600
Static Pressure (Pa)

500

400

300

Speed 2

200

100

0 50Hz

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Q- Airflow (m³/h)

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
2/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

Sound Performance

63 125 250 500 1k 2k 4k 8k Overall

Inlet (LwA) 60/45 71/56 76/61 78/63 76/61 72/57 71/56 68/52 83/68

Inlet LpA @ 1m 49/34 60/45 65/50 67/52 65/50 61/46 60/45 57/41 72/57

Outlet (LwA) 60/44 72/57 76/61 79/64 78/63 74/59 69/54 63/48 84/69

Outlet LpA @ 1m 49/34 61/46 65/50 68/53 67/52 63/48 58/43 52/37 73/58

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
3/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

Drawing

AV BV C D E F

950 741 710 500 590 14

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
4/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

Accessories
5138907600 - JBR-710 N

CIRCULAR DUCT FLANGE

Dimensions

D E H J

503 69 560 581

5136885000 - JCA-710 N

BACK DRAFT SHUTTER

Dimensions

D E F H J

503 285 300 560 581

5416722600 - BI-7

Support base for inclined curb mounted installations. To ensure a proper installation of the CRHB-CRHT roof fan it is essential to specify the roof pitch angle
(a) and the distance (d) between the roof beam profiles.

Dimensions

B C D

694 590 50

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
5/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS

5136865200 - JAA-710

ACOUSTIC UPSTAND

Corrections Dimensions

63 125 250 500 1k 2k 4k 8k


A B C D H G
-0 -2 -8 -14 -24 -28 -16 -11
D(M) (18
875 695 590 1000 785
(MI4))

5138908400 - JAE-710 N

CIRCULAR FLEXIBLE COUPLING

Dimensions

D E H J

503 254 560 581

C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 consultas@solerpalau.com - www.solerpalau.es
6/7
6/2/2022, 10:41:06 PM - EasyVent v.27/1/2022 Rev.25912 | Selection Id dd74a6b3-ba4b-45e7-8fca-1391413b1d62
MAX-TEMP CTVB/CTVT
5136331500 - CTVT/4/8-450 (400V50HZ) VE - ROOF MOUNTED FANS