You are on page 1of 3

TATA CUMMINS LIMITED Basic Engine Model : Curve Number : Page No.

ins
Cu
mm Jamshedpur-831004 , INDIA 6BTA 5.9 150 C TCL 011 1 of 3
INDUSTRIAL PERFORMANCE Engine Family : CPL Code : Date : Revision
CURVE 6B TC 502 10-Feb '04 1

Displacement : 5.9 litre Aspiration : TURBOCHARGED AND AFTERCOOLED


Bore : 102 mm Stroke : 120 mm No. of Cyl: 6
Emission Control : CMVR 96 Fuel system: MICO, (A2000) Advertised Power : 150 BHP @ 2200 RPM

All data is based on the engine operating with fuel system, water pump, lubricating oil pump & 380 mm H2O inlet air restriction and
with 75 mm Hg exhaust restriction; not included are alternator, fan, air compressor, optional equipment and driven components.

700
SPEED TORQUE
650
(RPM) (Nm)
600 1000 460
TORQUE (Nm)

550 1200 475


500 1500 655
450 1600 655
1800 628
400
2000 568
350
2200 485
300
1000 1200 1400 1600 1800 2000 2200
ENGINE SPEED (RPM)

120
SPEED POWER
110
(RPM) (kW)
100 1000 48
POWER (kW)

90 1200 60
80 1500 103
1600 110
70
1800 119
60
2000 119
50 2200 112
40
1000 1200 1400 1600 1800 2000 2200
ENGINE SPEED (RPM)

280
SPEED BSFC
(RPM) (g/kW.hr)
260 1000 232
BSFC (g/kW.hr)

1200 225
240 1500 207
1600 208
1800 211
220 2000 215
2200 225

200
1000 1200 1400 1600 1800 2000 2200
ENGINE SPEED(RPM)

PEAK TORQUE : 655 Nm @ 1600 RPM


Curves shown above represent gross engine performance capabilities obtained and corrected in accordance with ECE R 24 and
CMVR 115 (9) conditions.

PRODUCT ENGINEERING ALL VALUES MAY VARY WITHIN 5%


TATA CUMMINS LIMITED Basic Engine Model : Curve Number : Page No.

Cum
min
s Jamshedpur-831004 , INDIA 6BTA 5.9 150 C TCL 011 2 of 3
INDUSTRIAL PERFORMANCE Engine Family :CPL Code : Date : Revision
DATA SHEET TC 502 10-Feb '04 1

GENERAL
Reference ............. ............. ................ ........ .................... ................ ................AIR TO WATER AFTERCOOLING
Certification ............. ............. ................ ........ .................... ................ ................ ................ CMVR 96
Data on this sheet refers to installation diagram ........ .................... ................ ................ ................ .............. TBD
Weight Dry : kg ( with flywheel and alternator , but less starter and aircompressor ) ................ ................ .............. 413
Weight Wet : kg ............. ................ ........ .................... ................ ................ ................ .............. 437
Compression Ratio : ............. ................ ........ .................... ................ ................ ................ .............. 17.6 : 1
C . G . Distance from F.F.O.B mm ................ ........ .................... ................ ................ ................ .............. 328
C . G . Distance above crank center line : mm ........ .................... ................ ................ ................ .............. 155
Maximum Bending moment at R . F . O . B : Nm ........ .................... ................ ................ ................ .............. 1356
Thrust bearing load limit.
Maximum intermittent : N ................ ........ .................... ................ ................ ................ .............. 3781
Maximum continious : N ................ ........ .................... ................ ................ ................ .............. 1780

PERFORMANCE DATA
Idle Speed : rpm ................ ........ .................... ................ ................ ................ .............. 950
Maximum no load geverned speed : rpm ................ ........ .................... ................ ................ ................ .............. 2457
Maximum overspeed capability rpm (15 secs max) : ........ .................... ................ ................ ................ .............. 3750
Maximum altitude for continuous operation : m ........ .................... ................ ................ ................ .............. 2255
Clutch engagement torque @ 800 rpm : Nm ........ .................... ................ ................ ................ .............. N/A
When using Exhaust Brakes.
Exhaust pressure , at 2450 rpm , at turbo outlet must not exceed : kPa ................ ................ ................ .............. N/A
Brake blade must have orifice to control exhaust pressure.
Approximate engine retardation : kW ................ ........ .................... ................ ................ ................ .............. N/A

OIL AIR TO AIR FROM TURBOEXHAUST EXHAUST FUEL COOLANT HEAT REJECTION FRICTION
RPM PRESSURE TURBO FLOW PRESSURE FLOW TEMP FLOW FLOW COOLANT AIR POWER
kPa m3/min kg/min kPa m3/min Deg C kg / hr l / min kW kW kW

2200 345 10.9 14.1 120+10% 25.9 414 25.3 180 73.8 14.6 20

2000 345 10.2 13.1 124+10% 18 462 26.2 120 59.7 12.1 11

1500 345 6.7 8.6 100+10% 18.5 462 20.7 120 59.7 12.1 11

PRODUCT ENGINEERING ALL VALUES MAY VARY WITHIN 5% UNLESS SPECIFIED OTHERWISE
TATA CUMMINS LIMITED Basic Engine Model : Curve Number : Page No.

Cum
min
s Jamshedpur-831004 , INDIA 6BTA 5.9 150 C TCL 011 3 of 3
INDUSTRIAL PERFORMANCE Engine Family :CPL Code : Date : Revision
DATA SHEET TC 502 10-Feb '04 1

LUBRICATION SYSTEM
Oil Pan capacity :
High : Litre ............. ................ ........... .................... ................ ................ ................ .............. 15.3
Low : Litre ............. ................ ........... .................... ................ ................ ................ .............. 13.3
Total cpacity : Litre ............. ................ ........... .................... ................ ................ ................ .............. 17.4
Angularity low oil level : Deg Front up : 35 Rear up 35
: F/pump side up : 35 Exh side up: 35

AIR INTAKE SYSTEM


Max. temperature rise between ambient air and turbo air inlet : Deg C ................ ................ ................ .............. 15
Maximum intake restriction with dry type air cleaner , with clean filter
Medium Duty: mm H2O ................ ........... .................... ................ ................ ................ .............. 300
Heavy Duty: mm H2O ................ ........... .................... ................ ................ ................ .............. 380
Maximum intake restrication with dirty filter : mm H2O ........... .................... ................ ................ ................ .............. 635

CHARGE AIR COOLING


Design parameters for ambients : .................... ................ ................ LEVEL 2 .............. LEVEL 3
Maximum inlet manifold temperature : Deg.C .................... ................ ................ 55 .............. 50
Air onto charge cooler temperature : Deg.C .................... ................ ................ 25 .............. 20
Maximum ∆ P between turbo out/manifold in : mm Hg
. ................... ................ ................ ................ .............. 125
Intake pipe size normally acceptable : mm Hg .................... ................ ................ ................ .............. 65
For further information see European AEB PCD613

EXHAUST SYSTEM
Maximum back pressure imposed by piping and silencer : mm Hg .................... ................ ................ ................ .............. 75
Exhaust pipe size normally acceptable : mm dia ........... .................... ................ ................ ................ .............. 75

FUEL SYSTEM
Maximum restriction at fuel lift pump with clean filter : mm Hg .................... ................ ................ ................ .............. 102
Maximum return line restriction : mm Hg ........... .................... ................ ................ ................ .............. 510

COOLING SYSTEM
Engine coolant capacity : litre ............. ................ ........... .................... ................ ................ ................ .............. 10.0
Standard modulating thermostat (range) Deg. C ........... .................... ................ ................ ................ .............. 83.95
Maximum coolant pressure (no pressure cap/ thermostat closed) : kPa ................ ................ ................ .............. 276
Maximum coolant temperature (engine out) Deg.C ........... .................... ................ ................ ................ .............. 100
Maximum deaeration time : mins ................ ........... .................... ................ ................ ................ .............. 25
Maximum coolant flow to accesories : litres/min ........... .................... ................ ................ ................ .............. 75
Minimum coolant temperature L Deg. C ................ ........... .................... ................ ................ ................ .............. 70
Minimum fill rate : Litre/min ............. ................ ........... .................... ................ ................ ................ .............. 19
Minimum coolant expansion space % of system capacity : .................... ................ ................ ................ .............. 5
Mi nimum drawdown capacity excluding expansion space : litre .................... ................ ................ ................ .............. 5
Minimum allowable pressure cap : kPa .................... ................ ................ ................ .............. 50
Coolant alarm activation temperature : deg.C .................... ................ ................ ................ .............. 100
Air on fan , typical operating temperature range :Deg.C .................... ................ ................ ................ .............. 93
Shutter opening temperature : Deg.C ................ ........... .................... ................ ................ ................ DO NOT USE
Minimum cooling capacity @ nominal fuel rate : ........... .................... ................ ................ Level-2 .............. Level -3
Limiting Ambient temperature (LAT) @ rated rpm : deg. C ................ ................ 45 .............. 42
Limiting Ambient temperature (LAT) @ peak torque rpm : deg. C ................ ................ 40 .............. 37

ELECTRICAL SYSTEM
Maximum resistance of 24V starting circuit : Ohms ........... .................... ................ ................ ................ .............. 0.004
Minimum recommended battery capacity as per DIN 72311 and BS 3911.
Engine only with declutched load cold cranking amperes : ................ 12VOLT 500CCA 24VOLT 250CCA

STARTING SYSTEM
Minimum unaided cold start temperature -10 Deg.C at 120 average rpm
Minimum aided (Ether) cold start temperature -25 deg. C at 110 average rpm

ALL DATA SUBJECT TO CHANGE W ITHOUT NOTICE