You are on page 1of 3

Rebound Hammer Measurement

Sr. No. Location Direction Rebound Numbers

1 Girder No.1 Span 1 → 30 30 40 36 36 40

2 Girder Span 2 → 52 50 52 56 54 55

3 Girder 2, Span3 → 52 54 52 52 54 68

4 Girder No:-3 Span → 64 60 60 54 58 60


4

Pier LP5 (Delhi


5 → 62 60 66 64 64 62
Face)

Pier LP5 (Gurgaon


6 → 60 58 58 58 60 6
Face)

7 Pier LP4 (Delhi → 56 58 52 54 56 52


Face)

Pier LP4 (Gurgaon


8 → 60 62 58 60 58 58
Face)

Pier LP1 (Delhi


9 → 50 50 50 50 50 50
Face)

Pier LP1 (Gurgaon


10 → 50 52 48 50 42 50
Face)
easurement
Cube
Avg.
Compressive
d Numbers Rebound
Nos
Strength MPa

42 44 50 52 40 40.5

60 64 68 64 58 68.9

66 68 64 64 59 68.9

64 64 66 64 61 68.9

62 60 64 62 63 68.9

60 60 60 62 54 67

54 58 52 52 54 67

58 60 60 58 59 68.9

50 50 50 50 50 59.2

52 54 54 60 51 61.1
LP5A

2 3 4

LP4A

You might also like