Multisim Convergence Assistant Summary Report

Convergence Assistant Summary Report

Outcome:

The simulation error was corrected successfully.

Changes Made:

-Initial Conditions was changed to Set To Zero

-Maximum Timestep (TMAX) was changed to 1.0000e-003

-Relative error tolerance (RELTOL) was changed to 1.0000e-002

-Shunt resistance from analog nodes to ground (RSHUNT) was changed to


1000000000

Multisim Convergence Assistant Log

Step 1: Verifying Error Scenario


...completed.

Step 2: Setting parameter Integration Method (METHOD) to Gear


Simulating...
...completed. Simulation error still occurs.

Step 3: Setting parameter Initial Conditions to Set To Zero


Simulating...
...completed. Simulation error still occurs.

Step 4: Setting parameter Maximum Timestep (TMAX) to 1.0000e-004


Simulating...
...completed. Simulation error still occurs.

Step 5: Setting parameter Maximum Timestep (TMAX) to 1.0000e-003


Simulating...
...completed. Simulation error still occurs.

Step 6: Setting parameter Relative error tolerance (RELTOL) to 1.0000e-002


Simulating...
...completed. Simulation error still occurs.

Step 7: Setting parameter Shunt resistance from analog nodes to ground (RSHUNT) to
1000000000
Simulating...
...completed. Simulation error fixed.

Step 8: Attempting rollback of Initial Conditions to Automatically Determine


Simulating...
...Error recurred - rollback unsuccessful.

Step 9: Restoring value of Initial Conditions to Set To Zero

Step 10: Attempting rollback of Maximum Timestep (TMAX) to 1.0000e-005


Simulating...
...Error recurred - rollback unsuccessful.

Step 11: Restoring value of Maximum Timestep (TMAX) to 1.0000e-003

Step 12: Attempting rollback of Relative error tolerance (RELTOL) to 1.0000e-003


Simulating...
...Error recurred - rollback unsuccessful.

Step 13: Restoring value of Relative error tolerance (RELTOL) to 1.0000e-002

Step 14: Attempting rollback of Shunt resistance from analog nodes to ground
(RSHUNT) to 1.0000e+012
Simulating...
...Error recurred - rollback unsuccessful.

Step 15: Restoring value of Shunt resistance from analog nodes to ground (RSHUNT)
to 1000000000

Step 16: Attempting rollback of Integration Method (METHOD) to Trapezoidal


Simulating...
...Rollback successful.

Convergence Assistant completed successfully.