Catalog 2011
Components
Fuel Cells
Applications
Quintech e.K. · Danziger Str. 8 · DE-73035 Goeppingen · phone: +49 (0)7161/94 63 18 · email: info@quintech.de
www.quintech.de
Table of Contents
Accessories .................................................................................................................... 45
Mass Flow Controller ........................................................................................................... 45
Swagelok™ Fittings ............................................................................................................. 45
Nylon Washers and Teflon™ Shoulder Washers ...................................................................... 45
End Plates - Collector Copper Plates ..................................................................................... 45
Gas Flow Meters ................................................................................................................ 45
Die-Cuts for Gaskets, Electrodes, MEAs ................................................................................ 45
Methanol Fuel Cell System ............................................................................................ 46
EFOY Pro Series ................................................................................................................. 46
Hydrogen Fuel Cell System ........................................................................................... 48
Grid-off Power Supply - The Stromschachtel .......................................................................... 48
10kW Fuel Cell Subsystem ................................................................................................... 49
PEM FC Systems ............................................................................................................. 50
H-200 PEM FC System - 200 W ........................................................................................ 50
H-300 PEM FC System - 300 W ........................................................................................ 50
H-500 PEM FC System - 500 W ........................................................................................ 51
H-1000 PEM FC System - 1 kW ........................................................................................... 51
H-2000 PEM FC System - 2 kW ........................................................................................... 52
H-3000 PEM FC System - 3 kW ........................................................................................... 52
H-4000 PEM FC System - 4 kW ........................................................................................... 53
H-5000 PEM FC System - 5 kW ........................................................................................... 53
Hydride Storage Filling Station .................................................................................... 54
Reformer ....................................................................................................................... 55
Fuel Processing Modul FPM-C1 ............................................................................................ 55
Reformer Compact C1 ........................................................................................................ 55
Metal Hydride Storage System ...................................................................................... 56
10 Liter Hydrogen Storage - HB-SCF-0010-Q ................................................................ 56
50 Liter Hydrogen Storage - HB-SCF-0050-Q ................................................................ 57
100 Liter Hydrogen Storage - HB-SCF-0100-Q ................................................................ 58
300 Liter Hydrogen Storage - HB-SCF-0300-N ................................................................ 59
500 Liter Hydrogen Storage - HB-FR02-0500-B ................................................................ 60
500 Liter Hydrogen Storage - HB-FR07-0500-B ................................................................ 61
660 Liter Hydrogen Storage - HB-SCF-0660-N ................................................................ 62
2400 Liter Hydrogen Storage - HB-PR2400 ........................................................................ 63
3300 Liter Hydrogen Storage - HB-SS3300 ........................................................................ 64
16500 Liter Hydrogen Storage - HB-SS16500 ...................................................................... 65
Purchasing Procedures ................................................................................................. 66
Terms and Conditions of Sale, Delivery and Payment of QuinTech e.K. ...................... 67
For more fuel cell test systems and fuel cell test equipment please check our test equipment
catalog or www.fuelcell-testsystems.com
Shipping, handling, taxes or duties not included in the listed price. Technical details, components and prices are
subject to change without notice. Printing errors reserved. All orders must be printed and signed.
Description:
A system built upon the successful and versitle architecture of ElectroChem's standard MTSA 450 adding new available
options:
• computer control option with Notebook PC • key pad programmed for a wide range of gases
• programmable mass flow controller / temperature controller • digital flow rate display (sccm)
• customize data collection and aquisition with LabVIEW™ • 1000 sccm capacity
• custom graphics • 2 back pressure regulators
• versatile electronic load (0,1 - 400 W) • analog pressure display (psi)
• constant current and constant voltage mode • 1 temperature controller
• 2 precision calibrated mass flow controllers • precision PID algorithm
• dual load channels (3 V / 100 A and 20 V / 20 A) cover • 400 W AC output
the load profile over micro fuel cells, single cells, and fuel
cell stacks
MTSA-450-N
with gas management, humidification system and electronic load
MTSA-450 is a cost effective fuel cell test station which puts together a gas management unit, a humidification system and an
electronic load that provides a complete control features for conducting reliable fuel cell testing. All gas channels have
stainless steel construction. The gas management unit consists of 2 gas flow meters, 2 back pressure regulators and 2
pressure gauges. The humidification system includes two 1,5 liter stainless steel water vessels and provides 100 %
humidification with gas flow rates up to 3 SLPM. The temperature of the fuel cell and two gas humidifiers is controlled by
three temperature controllers. A solid state electronic load is capable of providing up to 400 W (20 V and 20 A max. or 3 V
and 100 A) and can be selected to operate at both constant current and constant voltage modes.
MTSA-450-NL
with gas management, humidification system, electronic load and laptop an LabVIEW™ software
The MTSA-450-L has all the advantage control feature of the MTSA-450 which puts together a gas management unit, a
humidification system and an electronic load that provides a complete control features for conducting reliable fuel cell testing.
In addition it comes with a laptop an Labview software compatibility. Electrochem has integrated the LabVIEW™ software to
facilitate fuel cell testing. Researchers have the freedom to customize the software to their individual needs.
Description:
Specification:
Manual controls:
load enable switch
Current control / Voltage control switch
(20 V / 20 A) / (3 V / 100 A) range switch
10 turn Potentiometer manual setpoint
Electrical accessories:
2 high flexibility, high Current leads
2 banana jack cell Voltage probes
rear panel screw terminal for input / output
frequency response to 10 kHz
Physical characteristics:
Size (w x h x d): 19” x 5,25” x 13”
(48 x 14 x 33 cm)
Weight: 10 lbs. (4,5 kg)
Electrical requirements:
110 V AC 5 A (or 220 V AC 2,5 A)
Description:
Specification:
Humidifiers (each): 100 % saturation at 75 °C for input gas flow 2 l/min., 2 liter water bottles (max. fill
capacity 1,6 liters)
Measure: (w x h x d) 17 1/2" x 12 1/4" x 18 1/2" (44 x 31 x 47 cm)
Gas connections: 1/ ”
4 Swagelok™ tubing connectors, front panel: output humidified reactant gases to
fuel cell (2), ports for refill of humidifier bottles (2), input reactant gases (2)
Electrical requirements: 110 V AC or 220 V AC
HSA™ - 7 A or 3,5 A
HSA-TC™ - 10 A or 5 A
HSA-TC-GTL™ - 10 A or 5 A
Description:
Hovacal is a portable calibration gas generator for accurate gas- vapor mixtures with selectable humidity and temperatures
up to 200 °C.
HOVACAL is based on the principle of dynamic evaporation of liquids and mixture with carrier gas. The calibration gas
generator consists of a supply unit and an evaporator. The supply unit containing the pump for liquid, flow controller for
carrier gas and temperature controller for the evaporator. The evaporator is installed separately from the supply unit. Both are
connected via a link for carrier gas, liquid and power supply. The gas output of the evaporator can be fed in a heated line or
directly in the gas analyzer. Accuracy, reproducibility and stability of the calibration gas mixture are achieved with a precision
mass flow controller for carrier gas and a peristaltic pump for liquid. The liquid flow can be verified with help of a balance,
the carrier gas flow with a gas meter. This guarantees the verification with primary standards at any time.
The complete calibration gas generator is mounted in a portable case. The calibration of emission monitoring systems needs
span gas with hydrogen chloride, ammonia, hydrogen fluoride and mercury chloride. Cheap standard solutions in a wide
concentration range are available for these components. The reagents have nearly infinite stability over time. No gas cylinders
are necessary. Precise water vapor mixtures for calibration of moisture analyzers or for gas humidifying can be produced with
water and air or with another carrier gas. Vapor gas mixtures with organic components can be generated with organic
reagents. Span gas for multi component analysis can be easily achieved with mixed reagents. The elevated temperature of the
gas vapor mixture avoids adsorption and corrosion of gas exposed surfaces.
Schematic:
Technical Benefits:
• high accuracy: due to precise mass flow meter and balance controlled liquid metering
• can be verified with primary methods: by means of gas meter and balance
• quick gas response time: due to minimized adsorption effects
• moisture content up to 60 Vol.-%: due to liquid evaporation of up to 6 ml/min
• wide range of output: concentration range of 1:100 with one standard solution
• gas flow up to 1000 l/h as standard (higher gas flows as options)
• independent of temperature since evaporates completely
• gas temperatures up to 200 °C: adjustable depending on the application
• quick change of components by replacing the standard solution
• gas mixtures produced from combined standard solutions
• customer-defined components can be generated by the user
• point-of-use generation: the separate evaporation unit generates the span gas where it is needed
• easy portable in the portable case for quick change of location
Safety Benefits:
• low pressure of the generated span gas • no leakage problems: only the required amount of gas is produced
• fewer high-pressure cylinders lessen the safety risk • simple transport without safety precautions
• simple disposal e.g. by means of neutralization • simple storage of the standard solutions in plastic bottles
Technical Data:
Vaporizer
Total flow range: max. 300 l/min gas/vapor mixture
Capacity of evaporation: max. 110 g/min water
Mass flow range water: 30 to 120 g/min
Flow range carrier gas: max. 155 l/min
Operating temperature: max. 120 °C
Outlet temperature: max. 120 °C
Ambient temperature: max. 50 °C
Gas connector inlet: 8 mm Swagelok™
Gas connector outlet: 12 mm Swagelok™
Liquid inlet: 1/ "Swagelok™
8
Wetted material: 1.4571
Power supply: 3 x 240 V AC, 9,6 kW
Dimensions: 50 x 50 x 30 cm (w x h x d)
Temperature control
Type: 2 x PID controller
Accuracy: ±5K
Operating elements: set point and parameterization at keypad, switch for heater power
Power supply: 3 x 240 V AC, 50 / 60 Hz, max. 10 kW
Metering pump water
Type: speed controlled precision pump
Flow rate: max. 150 ml/min
Accuracy: approx. 4 %
Operating elements: potentiometer, ON/OFF
Analog interface: 0 ... 10 V for set point
Power supply: 1 x 240 V, 50 Hz, 250 W
Dimension: approx. 24 x 15 x 26 cm (w x h x d)
Option: humidity control
Type: humidity controlled precision pump
Controller: PID
Humidity sensor: capacitive polymer
Operating temperature: max. 120 °C
Flow range pump: max. 150 ml/min
Operating elements: set point and parameterization at keypad, switch for pump
Power supply: 1 x 240 V, 50 Hz, 250 W
Dimensions: approx. 24 x 15 x 26 cm (w x h x d)
Price on request
Description:
Specification:
Fluid connection: 1/
4" Swagelok™ tube adapter
1/
4 Swagelok™ tube fitting
"
Measure: 60 cm, 100 cm
Weight: 1,0 kg
Specification:
Connection of single cells to the LENA PRO system is achieved through two 37 SUB-D connectors. Pin assignment as follows:
SUB – D Connector1: SUB – D Connector 2:
Negative terminal Cell 1 Pin 1 Negative terminal Cell 33 Pin 1
Cell 1 (plus) to Cell 32 (plus) Pin 2 through Pin 33 Cell 33 (plus) to Cell 64 (plus) Pin 2 through Pin 33
nc Pin 34 through Pin 37 nc Pin 34 through Pin 37
Connection to SPS or controller system is achieved via an RS232 interface.
The unit functions fully autonomously and will measure at maximum speed. Measured data is stored. The transmission of the
ASCI character [S] (call for data) over the interface will cause measured values to be transmitted in return. They are formatted
as follows (all ASCI characters):
[s] (start of data sequence)
value of cell 1 up to lowest value 3
value of next cell cell number of lowest value 3
up to value of last cell total voltage value
lowest value 1 CR/LF (end of data sequence)
cell number of lowest value 1
Value output is in mV. Separation of values by semicolon [;], start of sequence [s], end of sequence [CR/LF]. The cell to be
measured is assigned by transmitting [Z+numeric digit(s)+CR/LF]. Command confirmed output of [z;>Number<].
Description:
Performance
• CVMS is a realtime multichannel data acquisition system. It is
optimized for measuring the voltages of fuel cells, electrolytical
processes and capacitors with ultra-high capacitance (high-caps).
• CVMS is a modular system. Up to 31 measurement modules can
be connected into a system with up to 2790 channels. The system
operates stand-alone, configuration and measurement data are
exchanged via two CAN buses.
• The CVM measurement modules are equipped with a
microcontroller with comprehensive firmware functions. This allows real time measurements and enables later updates
through reprogramming.
• CVMS is a complete system. The hardware modules are complemented by software libraries for measurement and control.
Data can be visualized and stored for further processing.
Features:
Benefits:
• cost Reduction
- useable throughout the whole product life cycle (design, qualification, production, service).
• time Saving
- mature and field-proven product lets you concentrate on your project.
- fast and efficient installation through tailored software packages.
- all components perfectly matched
• quality and safety
- CVMS data enable a detailed analysis of fuel cell systems (ageing, degradation, water content, inhomogeneities of
the stack, etc).
- field proven design yields reliable results even in extreme environments.
Resolution: - 12 - Bit
Price on request
Accessories
• CAN-PC interfaces
- PC interface cards for USB, PCI bus and PCMCIA slot
• CVMLIB!pro:
- Windows library for configuration and communication for C, C++
• CVMView!pro
- Graphical user interface for configuration and visualisation
• Cables
- System cable set for one CVM module (CVMproFP-CS). Individual cables for CAN bus (CVMproCAN) and for
supply voltage (CVMproBAT)
- Principal features
• multi-channel measuring equipment and signal generation in the
smallest possible space: mearsurement channels, power drivers,
signal simulation, loads, relay matrix
• modular unit configuration on the basis of the MCM family
assemblies
• high scalability from a few up to several hundred channels
• time-synchronous processing of all inputs and outputs, even
across several units
• signal conditioning, digitisation and measurement value
processing in one assembly
• power consumption can be reduced by switching off channels that are not needed
• robust electrical design and small mechanical dimensions
• customer-specific assemblies can be added
- Application examples
• test bench technology: HIL systems, endurance testing, EOL test
• solar, fuel and lithium cell monitoring
• rapid prototyping applications
- Customer benefits
• low costs and small unit volume per channel combined with high performance
• easy integration into existing measuring environments
• low channel costs compared to solutions with conventional A/D cards and external signal conditioning (no assembly
and wiring effort)
• fast and effective start-up
Concept description:
The MCM concept unites all kinds of different types of channel under a single communication and data processing interface.
Apart from measurement inputs and signal outputs, this also includes power drivers, load and switching modules.
In addition to the excellent electrical properties of the individual channels, the integrated signal conditioning, time-
synchronous operation of all IOs and an extremely compact design were important design criteria.
Available IO-modules:
Description IO-size Channel number Analog / Digital Input / Output Coupling Further
MCM-MainControl Control modules for MCM-IO-modules
MCM-U08AII voltage 8 analog input isolated -
MCM-T08AII-TE temperature 8 analog input isolated thermocouple
Description:
The MCM-U08AII has an individual ADC, including associated voltage reference, available per channel. The supply and data
transmission of the channel is carried out via a separate insulated path.
This design guarantees completely time-synchronised acquisition and complete galvanic decoupling of all channels. In
addition, it permits maximum flexibility in the use of the measurement channels and effectively prevents mutual interference.
Each channel also possesses an individual measurement range switching circuit, automatic contact interruption detection and
a protection circuit that effectively intercepts dangerous voltage peaks.
Review:
- Principal features
• time-synchronised data acquisition on all measurement channels
• full galvanic decoupling of each individual measurement channel
• cascadeable to multichannel units
• DC voltage measurements up to 100 V
• measurement resolutions <100 µV
• individual channel measurement range selection
• automatic contact interruption detection
• signal conditioning, digitalisation and measurement value processing in one assembly
• early digitalisation reduces interference
• power consumption can be reduced by switching off measurement channels that are not needed
• robust electrical design and small mechanical dimensions
• 100 % compatible with other MCM assemblies
- Areas of application
• multi-channel voltage acquisition on test and HIL systems
• Voltage monitoring on fuel cells, battery stacks, lithium-based accumulators, electrolysers
• signal detection and pre-processing for rapid prototyping platforms
• EOL test benches and fatigue testing
- Customer benefits
• high freedom of use of each channel due to galvanic decoupling and individual configuration
• low channel costs compared to solutions with conventional A/D cards and external signal conditioning (no
assembly and wiring effort)
• robust design and permanent channel monitoring ensure a high degree of operational safety
• small amount of space needed even with a larger number of channels (for modularity and scalability, see
MCM unit concept)
Technical Data:
Resolution in 20 V ranges: 1 - mV
Parameter Values
Termination: MCM-Businterface
Operationg altitude / mounting position: max. 2000 m above sea level / any
Price on request
Description:
The MCM-T08AII-TE has an individual ADC, including associated voltage reference, available per channel. The supply and
data transmission of the channel is carried out via a separate insulated path.
This design guarantees completely time-synchronised acquisition and complete galvanic decoupling of all channels. In
addition, it permits maximum flexibility in the use of the measurement channels and effectively prevents mutual interference.
Each channel also has an input protection circuit, which effectively intercepts harmful voltage peaks. In addition, one PT100
temperature element per channel is used cold junction compensation.
Review:
- Principal features
• time-synchronised data acquisition on all measurement channels
• full galvanic decoupling of each individual channel
• cascadable to multichannel units
• thermocouple type "K"
• temperature measurement up to 800 °C
• automatic contact interruption detection
• signal conditioning, digitalisation and measurement value processing in one assembly
• early digitalization reduces interference
• power consumption can be reduced by switching off measurement channels that are not needed
• robust electrical design and small mechanical dimensions
• 100 % compatible with other MCM assemblies
- Areas of application
• multi-channel temperature acquisition in test facilities and test benches
• signal detection and pre-processing for rapid prototyping platforms
• process monitoring in process engineering
• crash tests (safe and reliable decoupling of measuring equipment and device under test)
- Customer benefits
• high freedom of use of each channel due to galvanic decoupling and individual configuration
• Low channel costs compared to solutions with conventional A/D cards and external signal conditioning (no
assembly and wiring effort)
• robust design and permanent channel monitoring ensure a high degree of operational safety
• Small amount of space needed even with a larger number of channels (for modularity and scalability, see
MCM unit concept)
Technical Data:
Parameter Values
Termination: MCM-Businterface
Operating altitude / mounting position: max. 2000 m above sea level / any
Price on request
Description:
Security:
FumaGen H2 provides hydrogen "on demand" and shows - inherent to the system - a better
security. Unlike bottled gas supplies, where gases are compressed up to a pressure of 200 bar,
there is no need for special precautions (e.g. security cabinets). The maximum pressure is 10
bar. The generator stores ca. 1 - 1,5 l compressed gas. In an ordinary ventilated room the
explosion limit of hydrogen-air mixtures of 4 % will even locally never achieved. Additionally the
electronic system control notifies creeping leakages, gives an acoustic alarm and provides an
automatic system shut down, if the failure is not removed within 20 minutes from the onset.
We offer with the new product family fumaGen H2 a new generation cost effective generators for hydrogen and/oroxygen
production. They are easy to use, show nearly maintenance free operation and excel in a great extend of flexibility. A supply
with deionised water and a power socket are sufficient in order to supply hydrogen and /or oxygen all over there, where
bottled gas supply is too circuitous or needs to much footprint. Continuousoperation or for casual service. Firm - quiet -
simple. Application areas are e.g. supply of fuel cell test stations, gas supply for small soldering or welding tools and for
laboratory purposes.
Technical Data:
Unit QT-HG-200 QT-HG-400 QT-HG-1500 QT-HG-3000 QT-HG-5000
O2-production
(pressureless): NL/min 0,100 0,200 0,750 1,500 2,500
Turndown: % 0 ... 100 0 ... 100 0 ... 100 0 ... 100 0 ... 100
Delivery pressure
regulated: 10 Pa (bar) 0 ... 30 0 ... 30 0 ... 30 0 ... 30 0 ... 30
Purity standard 5.0: H20 ppm <5 <5 <5 <5 <5
Cooling: air cooled air cooled air cooled air cooled/water air cooled/water
Total weight: kg 35 45 50 80 100
Price continuous
drying process: Euro inquire inquire 4.500,- 5.800,- 6.500,-
Or Sample:
H2 purity: < 5 ppm O2 purity: < 2 ppm
H2 production: 1,5 NL/min O2 production: 0,75 NL/min, pressure-free delivery
H2 pressure: at 10 bar adjustable Display: 4-line LCD, set points, status, alarm display, acoustical alarm
Safety feature: auto shut-off Electrical connectors: 230 V; 50 - 60 Hz
Measure (w x h x d): 31 x 55 x 46 cm Weight: 50 kg
Electrolysis Cells
Description:
We offer various PEM electrolysers and cell stacks in a sturdy construction. In addition to
single cells with active areas from 20 to 80 cm² also stacks up to 800 cm² surface are
affered. At current densities up to 400 mA/cm² electrolysers up to a power of 600 W are
realised. All of our delivered cells and stacks are designed for long life under industrial
conditions. Another characteristic is the high pressure resistance of our electrolysers.
Generally, all systems designed, so that hydrogen pressure up to 20 bar can be supplied.
So these electrolysers are used in hydrogen supply of laboratories and for continuous
emission measurements. The titanium electrolysers meet the highest demands on reliability,
even under high load while achieving a long life time.
The anode, used in all models, is made from titanium, the cathode is made of graphite,
titanium and stainless steel. In the described systems, it is possible to work permanently up
to the thermal limitation of the membranes. Even frequent load changes are easily coped.
Cathode and anode plates work wear-free.
Number of cells: 1 5 8 10
Water supply: 1/
8" clamping ring 1/
8" clamping ring 1/
8" clamping ring 1/
8" clamping ring
Gas outflow: 6 mm 6 mm 6 mm 6 mm
up to 10 bar 550,-
up to 30 bar 1.200,-
Description:
This is the most basic operational form of the PEM fuel cell. It consists of
the two metal current collector plates on either end, two flow field graphite
plates on the inside of those, carbon paper further inside, platinum on the
inside of that and the Nafion™ based membrane electrode assembly (MEA)
in the middle. All the fuel cell requires to generate electricity is hydrogen
and oxygen gas.
We now provide you with ElectroChems single cell fuel cells combining our
durable fuel cell hardware with our MEA. Performance curves are provided for use with H2 and O2. Standard MEA
specifications: 1 mg/cm² 20 wt. % Pt/C loading w/ Nafion™ 115. Custom specifications are available. A reference electrode
is provided in the EFC-05-REF and EFC-25-02-REF unit. It consists of a high purity platinum wire inserted into the anode flow
field so that it is in direct contact with the input hydrogen gas stream. Individual electrode potentials can be directly measured
relative to this reference electrode to allow researchers to identify individual electrode characteristics using a high impedance
potentiometer.
Complete single cell hardware with MEA and polarisation curve (IV curve)
• quality assurance
• reproducibility
• quick & easy assembly
• increased productivity
qCf innovative cell concept
The cross-section of a cellFixture below helps to
understand the principle of a qCf. The pressure
impact of the pneumatic actuator is applied directly to
the active fuel cell area in the cellFixture.
SFPU – support frame pressure unit; will be fully connected to the test-stand environment
cF cellFixture – for easy integration of specimens like MEAs, CCMs, GDLs, GDEs, etc.
Optimised for use in the qCf FC25/100; two sided frame for testing fuel cell internal components (flow fields, CCMs,
MEAs, GDLs, GDEs, membranes etc.). Easily closed and inserted into the qCf as a compact unit by using quick clamps.
Media supply and pickup of the measurement data over the qCf.
• max. operating temperature: 130 °C • fuel: methanol, H2, reformate
• active cell area: 25 cm² (50 x 50 mm) • standard flow field: Graphite, 5 x Serpentine
• custom flow field design possible
cF25/100 LT Gr V1.1 Price in Euro: 2.240,-
• during the measurement an optional cellFixture can be prepared • potential free pickup of cell voltage
cF25/100 LT Gr V1.1 with humidity sensor Price in Euro: not available
• with integrated capacitive humidity sensor • potential free pickup of cell voltage
• during the measurement an optional cellFixture can be prepared
cF25/100 LT Gr CSL V1.1 Price in Euro: 15.900,-
Integrated current scan lin to analyse the current density distribution, for optimisation and failure diagnostics of fuel cell
internal components and optimisation of operating conditions. Sensor with a resolution of 7 x 7 mm (1 x 1 mm Current
Scan High Res optional)
• with integrated Current Scan lin • Current density up to 2,5 A/cm²
• with USB connection, cable and power source; User Interface operable under WINDOWS 2000 and XP
Optimised for use in the qCf FC50/125; two sided frame for testing fuel cell internal components (flow fields, CCMs,
MEAs, GDLs, GDEs, membranes etc.). Easily closed and inserted into the qCf as a compact unit by using quick clamps.
Media supply and pickup of the measurement data over the qCf.
• max. operating temperature: 130 °C • fuel: methanol, H2, reformate
• active cell area: 50 cm² (70 x 71 mm) • standard flow field: Graphite, 5 x Serpentine
• custom flow field design possible
cF50/125 LT Gr V1.1 Price in Euro: 2.890,-
• during the measurement an optional cellFixture can be prepared • potential free pickup of cell voltage
cF50/125 LT Gr V1.1 with humidity sensor Price in Euro: not available
• with integrated capacitive humidity sensor • potential free pickup of cell voltage
• during the measurement an optional cellFixture can be prepared
cF50/125 LT Gr CSL V1.1 Price in Euro: 17.800,-
Integrated current scan lin to analyse the current density distribution, for optimisation and failure diagnostics of fuel cell
internal components and optimisation of operating conditions. Sensor with a resolution of 7 x 7 mm (1 x 1 mm Current
Scan High Res optional)
• with integrated Current Scan lin • Current density up to 2,5 A/cm²
• with USB connection, cable and power source; User Interface operable under WINDOWS 2000 and XP
Description:
We offer custom fuel cell stacks. Fuel cell stacks are multiple cells attached in series. The EFC50-CST custom stack is
designed for the researcher to be able to select the operating characteristics of the fuel cell stack. The user specifies the
number of cells, with a minimum of 7 MEAs (50 W) and a maximum of 30 MEAs (300 W). The stack design incorporates the
same 50 cm² active area, identical to those of the 50 W stack. The total power output may vary based upon the environment
(temperature, humidification, etc.) of the stack.
ElectroChems fuel cell stack is designed for ease of use and reliability. This unit will give you years of trouble free operation.
The fuel cell stacks can operate without external humidification at pressures up to 3 atmospheres of H2 and O2. The EFC50-
ST unit generates 50 W of power under normal operating conditions and can provide up to 100 W peak power. No gas
recirculation is required, under normal operating conditions. ElectroChems stacks can be operated at utilization levels for
pure H2 and O2 close to 98 %. The recommended pressure for hydrogen and oxygen gases is 50 psig. Each plate includes a
thermocouple well and a banana jack for accurate temperature and voltage measurement.
Specification:
Average cell voltage: 0,65 +/- 0,05 V
Current density: 350 +/- 50 mA/cm²
Total power: 180 - 280 mW/cm²
Humidification: not required at 50 W, 100 W, 200 W operation, dependent on power density
Complete Stack with conditioned MEAs (tested and delivered with polarisation curve)
FC-50-02-17-ST 50 cm² PEM fuel cell hardware; 17 cells; 18 graphite plates; serpentine flow pattern;
fittings; gold plated copper current collectors; voltage monitor banana jacks on each plate;
2 banana plugs inquire
FC-50-03-7-ST 50 cm² PEM fuel cell hardware; 7 cells; 8 graphite plates; straight channel flow pattern;
fittings; gold plated copper current collectors; voltage monitor banana jacks on each plate;
2 banana plugs 4.746,-
FC-50-03-17-ST 50 cm² PEM fuel cell hardware; 17 cells; 18 graphite plates; straight channel flow pattern;
fittings; gold plated copper current collectors; voltage monitor banana jacks on each plate;
2 banana plugs inquire
Description:
The phosphoric acid fuel cell uses a liquid phosphoric acid electrolyte in a
silicone carbide matrix to carry hydrogen ions from the anode to the
cathode. The operating temperature range is 100 - 200 °C.
The fuel cells are designed for ease of use and many years of service. Gas
diffusion electrodes (ordered separately) are held in place between graphite
cellblocks. Flow fields machined into the blocks allow for the flow of
reactants and provide excellent electrical contact to the Membrane
Electrode Assembly electrodes. Current is collected by connection to copper
contact plates; separate voltage connectors are provided directly in the
cellblocks for maximum accuracy in iR measurement. Each unit includes
resistive heaters and thermocouple wells for accurate temperature control.
The cell is equipped with a reservoir for the continuous supply of
phosphoric acid to electrodes.
Accessories
Since the electrolyte in a Phosphoric Acid fuel cell is a liquid, the solution must be soaked in a matrix so that it can
be contained in the fuel cell.
ElectroChem’s phosphoric acid matrix assemblies are designed to provide consistent and reproducible
performance. Wet-proofed carbon paper is used as a support for 10 wt. % Pt/C based electrodes. High purity
silicon carbide, SiC, is used as the matrix.
Description:
The Conductivity Cell is a fixture for loading a membrane sample into your fuel cell
hardware for performing four-electrode conductivity tests.
The Conductivity Cell, with the membrane sample loaded, fits between the anode and
cathode conduction plates of your fuel cell hardware, making use of the existing gas flow
paths of the cell hardware. Your cell hardware and test stand are used to control the
sample temperature and pressure as well as the incoming gas composition and humidity
level.
The advantage of the four-electrode conductivity measurement is the ability to separate the
following measurements:
• voltage drop due to ion creation
• voltage drop due to ion flow
By considering only voltage drops due to ion flow, accurate assessments of membrane Fuel Cell Hardware
conductivity (and resistivity) can be made. The CdC-115 Conductivity Cell was designed Conductivity Cell - Assembled
for use with ElectroChem fuel cell hardware (for 5 and 25 cm²). in place of the MEA for pure
membrane testing
Components of Conductivity Cell:
• The Conductivity Cell is manufactured from PTFE (Teflon™), which is chemically inert, seals well against the carbon plates
of the cell hardware, and has the ability to withstand higher temperatures (up to 200 °C).
• Provides a gas-tight environment (when assembled in the fuel cell test hardware) for better control of humidity, pressure,
and temperature of the membrane sample during test.
• contains five ports:
- two for voltage measurement
- two for application of current
- one for insertion of a thermocouple near the membrane
• PTFE clamps secure the membrane in the Conductivity Cell
• Platinum wire carries voltage and current signals from the membrane to the controller
• Platinum gauze serves as catalyst site
Sample Data:
Following is a sample of conductivity test results for Nafion™112 using a scanning DC method.
Optional Designs:
CdC-110 Conductivity Clamp: for use in a beaker or in your humidity chamber.
CdC-112 Conductivity Cell: for use with Fuel Cell Technologies fuel cell hardware (5, 10 and 25 cm²).
Description:
Technical Benefits:
Digital Humidity Sensor Hygroclip-IM-1, Active Converter Cable AC3001 to USB: 830,-
For universities, industrial researchers, different other interested institutions for test and demonstration purposes, prototyping,
power supply und special conditions etc.
Operations Conditions:
PEM fuel cells are working in a temperature range of 20 ° up to 70 °C. The best working-temperature is between 50 ° up to
60 °C. The stacks are able to start at room temperature.
Usually the stack operates with pure hydrogen and air. Optional we deliver stacks for reformat gas or pure oxygen. The
construction-conditioned low pressure drop between inlet and outled of a cell enables to operate the stacks nearby ambient
pressure. The BZ 100 and BZ 560 have optionally the possibility for pressurised operation.
PEMFC-Stack BZ 560
Description:
The fuel cell stack BZ 560 is developed for outputs from 3 kWel up to 15
kWel. The BZ 560 is working at a temperature of 20 ° up to 70 °C and
allows on demand a pressurised operation up to 2 bar abs. The different
variation possibilities in using pure hydrogen, reformate gas with different
hydrogen concentrations, air or pure oxygen allows the use in a wide
range of applications. A very low pressure drop.
Specification:
Nominal load P (kW) Voltage U (V) at nominal load Dimensions (l x w x h in cm) Weight (kg)
3 12 31 x 37 x 27 39
5 21 39 x 37 x 27 52
10 36 52 x 37 x 27 66
Price on request
PEMFC-Stack BZ 100
Description:
The PEM-fuel-cell-stack BZ 100 has an active area of 100 cm² per single-cell.
The stack is provided with fuel gas (reformate or H2) and oxidant (air or O2)
through external connectors and the gases are distributed to the single cells by
internal manifolding. An additional cooling water circuit allows heat removal and
the utilisation of the waste heat. The BZ 100 is working between a temperature
rangeof 20 ° up to 70 °C and allows a pressurised operation up to 2 bar abs on
demand.
Specification:
Nominal Voltage U (V) at Dimensions Weight
load P (W) nominal load (l x w x h in cm) (kg)
100 2,4 13 x 14 x 14 4,5
Price on request
PEMFC-Stack BZ 130
Description:
The fuel-cell-stack BZ 130 has an external cathode gas manifolding open to
the ambient air. For this reason the active area compared with the BZ 100
increases up to 126 cm². In addition to that you can use a radial fan for
supplying that stack with air. The very low pressure drop between cathode-inlet
and -outled makes by reducing peripheric losses a system very efficient. With a
very simple air-recirculation-system, you can create a system-integrated air-
humidifiacation. The BZ 130-stack is also with an air-cooled design available.
Specification:
Nominal Voltage U (V) at Dimensions Weight
load P (W) nominal load (l x w x h in cm) (kg)
100 2,4 14 x 14 x 14 4,6
Price on request
Nafion™ Membranes
Description:
In order for a fuel cell to work, a membrane is needed that will carry the hydrogen ions from the anode to the cathode
without passing the electrons that were removed from those atoms. In a PEM fuel cell, DuPont’s Nafion™ material (a solid
polymer similar to Teflon™) is used.
We offer DuPont’s Nafion™ perfluorinated ion-exchange membranes. Standard size is 30 x 30 cm. Standard types are
below. The last digit represents the thickness in mils (thousandths of an inch, or 25,4 µm) - Nafion™ 112 is 2 mils thick, etc.
Item and Price:
Nafion™ NM-112, 212 NM-115 NM-117
10 x 10 cm 30,- 35,- 40,-
100 x 60 cm 750,- - -
fumapem Membranes
Description:
Prices:
20 x 30 cm 58,- currently not available currently not available 60,- currently not available
Electrodes
Description:
Anode and cathode electrodes for a fuel cell consist of catalyst loaded onto a gas diffusion backing. Gas diffuses through the
backing and is broken down by catalysis. Electrodes conduct current out of the cell. On the other end of the membrane
platinum is again used to bind the proton, electron, and an oxygen atom together to create water, ending the reaction.
ElectroChem’s gas diffusion electrodes are used in PAFC and PEM membrane electrode assemblies as well as in different
types of batteries. We use Platinum/Carbon catalyst with various loadings laminated to a hydrophobic backing (graphite fiber
paper or cloth is considered the best). Our standard electrode is made with 20 wt. % Pt/C catalyst on carbon paper.
Specification and Price:
Item Description Price
CCM-H25-N212 active area 5 x 5 cm (total 10 x 10 cm); cathode 0,6 mg/cm² Pt (Pt on advanced
carbon); anode 0,3 mg/cm² Pt (Pt on advanced carbon); Nafion™ 212 45,-
CCM-M25-N115 active area 5 x 5 cm (total 10 x 10 cm); cathode 1,2 - 1,4 mg/cm² Pt (Pt on advanced
carbon); anode 3,0 mg/cm² PtRu (PtRu black; molar ratio 1:1); Nafion™ 115 79,-
CCM-M25-N117 active area 5 x 5 cm (total 10 x 10 cm); cathode 1,2 - 1,4 mg/cm² Pt (Pt on advanced
carbon); anode 3,0 mg/cm² PtRu (PtRu black; molar ratio 1:1); Nafion™ 117 79,-
CCM-H50-N212 active area 7,23 x 7,27 cm (total 10 x 10 cm); cathode 0,6 mg/cm² Pt (Pt on
advanced carbon); anode 0,3 mg/cm² Pt (Pt on advanced carbon); Nafion™ 212 79,-
CCM-M50-N117 active area 7,23 x 7,27 cm (total 10 x 10 cm); cathode 1,2 - 1,4 mg/cm² Pt (Pt on
high surface area carbon); anode 3,0 mg/cm² PtRu (PtRu black; molar ratio 1:1); 106,-
Nafion™ 117
CCM-H100-N212 active area 10 x 10 cm (total 12 x 12 cm); cathode 0,6 mg/cm² Pt (Pt on advanced
carbon); anode 0,3 mg/cm² Pt (Pt on advanced carbon); Nafion™ 212 106,-
Please ask for prices for different membranes, different sizes, different loadings or when ordering 5 - 10 pieces.
Please indicate any changes according to the available options. We can make customized MEA's to meet your research needs.
We offer the materials not only as raw materials but also hydrophobic. PTFE loadings from
5 % to 30 % are available. The third possibility is a Plasma treated surface. The advantage
of this nano-technology is that the material can be made hydrophobic without any
substantial change of the bulk properties. In this case the water handling is facilitate,
without altering compressibility, weight, thickness and consequently conductivity and gas
permeability.
Specification and Price:
Item Weave Count Thickness Porosity PTFE Size Pric
warp/cm - weft/cm µm % % cm x cm
CC-G-5N 23 - 25 277 76 none 30 x 30 95,00
CC-G-7 23 - 25 367 78 none 30 x 30 97,00
CC-G-8 30 - 36 400 79 none 30 x 30 108,00
CC-G-5N 23 - 25 277 76 5 - 30 30 x 30 127,00
CC-G-7 23 - 25 367 78 5 - 30 30 x 30 129,00
CC-G-8 30 - 36 400 79 5 - 30 30 x 30 140,00
CC-060 - - - - 19 x 19 54,00
CC-060T - - - - 19 x 19 95,00
CC-CMPL - - - - 17 x 17 368,00
Please inquire for other materials and sizes (in lfm available).
Description:
Freudenberg has developed a full line of Gas Diffusion Layers designed to meet the various requirements in Hydrogen
(PEMFC) and Direct Methanol Fuel Cells (DMFC). Our Gas Diffusion Layers are manufactured by our proprietary nonwoven
technology that allows a high degree of flexibility in the design in order to meet the specific needs of our customers.
Performance: Our application specific GDLs perform consistently well in almost all PEM and DMFC applications. Our
uniform and smooth MPLs ensure a high performance level for the application they are specially developed for.
Processability: Freudenbergs flexible GDLs are ideally suited for continuous post-treatments and roll to roll laminations.
Since our GDLs are resistant to tear and cracking they are also the preferred material for GDLs and MEAs with integrated
seals.
Quality: Freudenbergs vertically integrated production process from the fibrous raw material to the final product guaranties
consistent quality and performance. Statistical process controls and additional ex-situ measurements are standard procedures
at Freudenberg FCCT.
Technical Support: In an emerging and
continually improving technology, it is
essential to fully understand the
requirements and applications of our
customers. Our global team of highly
qualified experts can assist our customers
in choosing the best possible solutions for
their GDL needs.
Item H2315 H2315 H2315 H2315 H2315 H2315 H2315 H2315 H2315 H2315
Features T10A T20A I6 C2 C4 I3 C1 I3 C4 I2 C6 I2 C8
Hydrophobic treatment: x x x x x x x
MPL: x x x x x x
Description:
The N series is a porous carbon paper that adapts PAN-based carbon-fiber with high
gas-permeability and conductivity. The 2nd generation of carbon substrate has very
even pore size in carbon structure. The paper material is suitable for all the fuel cell
configurations.
The W series is a unique design for carbon cloth GDL. The 2nd generation of carbon
substrate in woven type is developed to be highly suitable for the MEA process.
Currently, we have two different carbon cloths in the new generation, in which they are
typically varied in thickness. This series product items can all be furthermore adjusted
the hydrophobicity level to ensure the best fuel cell efficiency. Please be informed that
advantages of W Series include its high strength and even pore size; besides, the two
properties can also be reinforced by MPL coating.
Using TECLOCK
Thickness: µm 360 410 180 210 310
SM-114
Tensile Strength:
Flexural Modulus:
Air Permeability: secs Gurley Method** <6 <8 < 10 < 30 < 16
Through-Plane: mΩ* cm² ASTM C-611*** <5 < 13 <7 < 15 < 15
Type: Cloth substrate Cloth + MPL Paper substrate Paper + MPL Paper + MPL
Size: cm 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20
* Sample width: 24,4 mm; Effective specimen length: 45 mm; rate of grip separation: 6,35 mm/min
** Test condition: 300 cc; 0,1 sq in orifice; CFC-030
*** 4-probe measurement , circular (50 mm diam) copper-plated contacts under 200 psi
Description:
Nafion™ Solution, solution (a diluted, liquid form of the same chemical used for a PEM fuel cell membrane) drastically
reduces the amount of platinum needed as a catalyst by exposing a larger fraction of the platinum to the hydrogen gas. Also,
the Nafion™ acts as a binding agent to hold the platinum, membrane, and carbon paper together. Nafion™ perfluorinated
ion-exchange solution is in a mixture of lower aliphatic alcohols and water. Contains 15 - 20 % water.
Teflon™, like the Nafion™, acts as a binding agent and sometimes replaces the Nafion™ solution for that purpose because it
is less expensive. Also, coating the carbon paper with Teflon™ prevents the paper from being saturated by liquid water, while
still letting water vapor through the pores.
NS-5-AQ Nafion™ solution; balanced with water (non HazMat); 250 ml 484,50
* The first number of the FLI solutions (namely 9 or 10) shows the equivalent weight in 100 g/eq.
For more products or sizes, please inquire.
Catalysts
Description:
The fuel cell creates power by oxidizing a hydrogen atom into a proton and an electron on anode electrode and reduced
oxygen atom with proton on cathode. In a PEM fuel cell, Platinum is used as the catalyst. A direct methanol fuel cell requires
the addition of Ruthenium as a catalyst. It is used to promote the oxidation and redirection reactions.
Electro catalysts for fuel cell applications contain 10 % or 20 % Pt on VULCAN XC-72R carbon support. Typical electro-
chemical area (ECA) for 20 % Pt/C is 100 m²/g. Typical ECA for 10 % Pt/C is 140 m²/g.
Pt/Ru electro-catalysts carbon monoxide tolerant electro-catalyst for direct methanol fuel cell applications contains 20 % Pt
and 10 % Ru (50 : 50 atomic ratio) on VULCAN XC-72R carbon support. 20 % Pt and 10 % Ru catalyst exhibits better
resistance to CO poisoning and it is well suited for direct methanol conversion fuel cells. The catalyst can also be used in
fuel cells operating in conjunction with gas reformers.
Vulcan black:
Graphite Plates
Description:
Attached to the electrode backings of a fuel cell stack on either side are large
graphite plates. These plates serve a double purpose. One purpose is to act as a
conductor by receiving the energy from the electrodes. Its other purpose is to
guide the flow of the hydrogen and oxygen through their respective ends of the
stack, making sure that the maximum amount of the gasses and moisture comes
in contact with the membrane. To prevent gasses from leaking out through the
normally porous graphite, the plates are constructed using a much longer and
more complex process that creates nonporous plates.
Specification: ISOTROPIC GRAPHITE of ElectroChem graphite plate GP-50MP*
Flexural strength: 10,000 psi 6000 psi
Thermal conductivity: 120 W/mK 50 W/mK
Specific resistivity: 10,8 µohm-m -
GP-05-02-H2R-MP machined graphite plate for 5 cm² reference for EC fuel cell; serpentine flow pattern; built
in hydrogen reference electrode 1.381,-
GP-25-01-MP-DM machined graphite plate for 25 cm² for EC fuel cell; PIN flow pattern for direct methanol 856,-
GP-25-02-MP machined graphite plate for 25 cm² for EC fuel cell; serpentine flow pattern 856,-
GP-25-02-REF-MP machined graphite plate for 25 cm² reference for EC fuel cell; serpentine flow pattern 1.381,-
GP-50-02-O-MP machined graphite unipolar output plate for 50 cm² for EC fuel cell; serpentine flow field 1.166,-
GP-50-02-I-MP machined graphite unipolar input plate for 50 cm² for EC fuel cell; serpentine flow pattern 1.166,-
GP-50-02-B-MP machined graphite bipolar plate for 50 cm² fuel cell; serpentine flow pattern; for EC 531,-
GP-50-03-O-MP machined graphite unipolar output plate for 50 cm² fuel cell; straight channel flow pattern 1.166,-
GP-50-03-I-MP machined graphite unipolar input plate for 50 cm² fuel cell; straight channel flow pattern 1.166,-
GP-50-03-B-MP machined graphite bipolar plate for 50 cm² fuel cell; straight channel flow pattern 531,-
CP-05-C cooling graphite plate for 5 cm² for EC inquire
Gaskets
Description:
The components of the fuel cell do not in and of themselves make a good seal, so medical grade silicone gaskets (having
precise thicknesses for reproducible sealing) are used to create airtight seals between components. These are the standard
gaskets that are precision cut to fit ElectroChem fuel cells.
EC-GS-SIL-NC04 Silicone Gasket; non cut sheet 4" x 4" (customer specifies thickness 8, 10, 12 or 16 mils) 54,-
EC-GS-SIL-NC12 Silicone Gasket; non cut sheet 12" x 12" (customer specifies thickness 8, 10, 12 or 16 mils) 289,-
EC-GS-TFE-NC04 Teflon™ Gasket; non cut sheet 4" x 4" (customer specifies thickness 5, 7, 9, 10, 12 or 44,-
15 mils)
EC-GS-TFE-NC12 Teflon™ Gasket; non cut sheet 12" x 12" (customer specifies thickness 5, 7, 9, 10, 12 or 230,-
15 mils)
FGS Family Base Price
EC-GS-FGS-10 Silicone Coated Fiberglass Gasket; 10 mils; with assembly holes for ElectroChem Fuel 68,-
Cells; 10 x 10 cm
EC-GS-FGS-NC04 Silicone Coated Fiberglass Gasket; 10 mils; no assembly holes; 10 x 10 cm 68,-
EC-GS-FGS-NC12 Silicone Coated Fiberglass Gasket; 10 mils; no assembly holes; 30,5 x 30,5 cm 293,-
EC-GS-FGT-NC12 Teflon™Coated Fiberglass Gasket; 10 mils; no assembly holes; 30,5 x 30,5 cm 273,-
If you would rather we didn't cut them to our design, please let us know.
Heaters
Description:
While a PEM fuel cell will run at room temperature, it has maximum efficiency
at just below the boiling temperature of water (but not over, otherwise the
membrane will dry up, rendering it unable to carry protons). Therefore, heaters
are recommended for the test cells to run efficiently. The silicone rubber heater
is a small resistance heater pad that is attached to either end of the fuel cell.
The fire rod heater also a resistive element that is inserted into a matching
diameter hole in the graphite plates.
Specification and Price:
Item Description Price
H-SR1 silicone rubber heater for 5 cm², 25 cm², 50 cm² fuel cell; 60 W, 120 V; set of two 124,-
H-FR1 fire rod heater od 1/8 ", l 1,5 "; 60 W, 120 V 116,-
H-FR2 fire rod heater od 1/8 ", l 2,0 "; 100 W, 120 V 116,-
H-RP1 fiberglass rope heater 1 feet long; 60 W, 120 V 57,-
H-RP2 fiberglass rope heater 2 feet long; 104 W, 120 V 68,-
Moisture Trap
We offer a moisture trap that separates out the water from the exit gas streams
and prevent water clogging inside the backpressure regulator. You can also use
the collected water to calculate the efficiency of your fuel cell.
Specification and Price:
Operating pressure: 2 - 10 bar
Max. operating temperature: 52 °C
Max. flow: 260 l/min
Connection: 1/
4 " Swagelok™
Automatic drain
Automatic drain moisture trap MT-1: 406,-
Back flow back pressure regulators control the fuel cell operating pressure.
Gas flow back pressure regulator BPR-1: 0 - 50 psig (0 - 3,45 bar) Price in Euro: 774,-
Swagelok™ Fittings
Description:
Swagelok™ tube fittings provide a leak proof, torque free seal at all tubing connections and eliminate costly, hazardous leaks
in instrumentation and process tubing. All the action in the fittings moves along the tube axially instead of with a rotary
motion. Since no torque is transmitted from the fitting to the tubing, there is no initial strain, which might weaken the tubing.
Specification:
• gaugeable tube and adaptor fitting • easy to disconnect and retighten
• available in tube sizes from 1/16 to 2 inches and 2 to 50 mm • wide variety of materials and configurations
• consistent gaugeability upon initial make up
Item and Price:
Item Description Price
SWL-N-05 Nylon Swagelok™ fittings; male-connector 1/4 x 1/8 NPT 4,20
SWL-N-25 Nylon Swagelok™ fittings; male-connector 1/4 x 1/16 NPT 8,90
SWL-TFL-05 Teflon™ Swagelok™ fittings; male-connector 1/4 x 1/8 NPT 22,80
SWL-TFL-25 Teflon™ Swagelok™ fittings; male-connector 1/
4 x 1/
16 NPT 47,30
Description:
• Robust industrial construction: EFOY Pro are delivered in a robust metal casing. The integrated user interface allows
monitoring and control directly on the unit.
• More freedom when refueling: EFOY Pro can be hooked up directly to all EFOY Fuel Cartridges. Selecting the
optimum size of fuel cartridge for your requirements allows you to optimise the weight and operating time of your appliance.
• More flexible installation in your appliance: EFOY Pro can be fitted in your appliance in a variety of ways. Thanks
to the extended fuel cartridge hose, the positioning of the fuel cartridge can be chosen freely for example beneath the EFOY
Pro.
• One for all – charges 12 V and 24 V batteries: EFOY Pro are compatible with 12 V and 24 V batteries. The inte-
grated charge control system identifies the battery in use and automatically adjusts the charge process accordingly.
Accessories:
Specification:
Nominal output: 25 W 65 W 90 W
Nominal voltage: 12 V / 24 V 12 V / 24 V 12 V / 24 V
Weight: 7,8 kg (17,9 lbs) 8,4 kg (18,7 lbs) 8,8 kg (19,4 lbs)
Price on request
Dimensions (l x w x d): 190 x 145 x 283 mm 230 x 193 x 318 mm 420 x 280 x 360 mm
Price on request
Electricity is available nearly everywhere and anytime. But still the availability of
a powerful and stable electric grid can not be guaranteed, e.g. In lodges, on
boats, in caravans. The assembling and the operation of such grid-off power
supply stations are also often very expensive. The fuel cell technology offers a
new possibility to supply such applications with electricity, especially if there is a
demand on low-noise, zero-emission electricity production and maintainability.
Description:
This fuel cell system is controled by a microprocessor control unit, which takes care
on all necessary conditions to ensure an reliable use of the system.
Usually the fuel cell system is build as a hybrid system including a standard
accumulator. This configuration (electricity out of the fuel cell as well as out of the
accumulator) results in higher dynamic behaviour, improved reliability, but also in
lower system costs. The fuel cell is designed for the base load and not for peak
loads. This results in a smaller fuel cell which is cost driver of such a system. Many
applications need much higher peak loads than average loads (e.g. starting current
at electric motors). The “Stromschachtel” provides 12 V DC or 24 V DC and
optionally 230 V AC with an permanent electrical power output of 1,2 kWel. Peak loads can be covered depending on the
type and size of accumulators.
Specification:
Hydrogen purity: > 3,0 (hydrogen from electrolysers or hydrogen without CO, sulfur compounds)
Weight: approx. 30 kg
Ambient temperature: 10 ° - 40 °C
Price on request
Description:
The 10 kW fuel cell subsystem is the latest result of continuous system optimization.
Based on the BZ 560 fuel cell stack design. The main focus of this system is to achieve a
high overall efficiency by eliminating parasitic losses and reduced system dimensions.
Possible fuel options are pure hydrogen or reformate gas. The nominal electrical output
is 5 to 10 kWel, depending on application needs. Compact system architecture with
clearly arranged external interfaces allows an easy integration of the system into different
customer applications. Possible applications are off grid power supplies, power supplies
for mobile hybrid power generators or as a cogeneration system to supply heat and
electricity.
Specification:
Rated power: 10 kW
Rated voltage: 32 V DC
Weight: approx. 85 kg
Coolant temperature: 60 ° - 70 °C
Price on request
The H-200 PEM fuel cell system includes a rated 200 W air-cooled, air-breathing
and self-humidified PEM fuel cell stack with integrated fan and aluminium casing,
and electronic controls. The fuel cell weighs only 1,5 kg and measures only
223 x 109 x 94 mm. At maximum power output, the H-200 system consumes
2,8 l of H2 per minute, and has a peak power of 220 W.
Specification and Price:
Number of cells: 48 Humidification: self-humidified
Rated power: 200 W Cooling: air (integrated cooling fan)
Performance: 28 V at 7,2 A Weight (with fans & casing): 1,5 kg
H2 supply valve voltage: 12 V Dimensions with fans: 223 x 109 x 94 mm
Purging valve voltage: 12 V Flow rate at rated output: 2,8 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 40 % at 28 V
External temperature: 5 ° - 30 °C Controller: 400 g
Max. stack temperature: 65 °C Low voltage shut down: 24 V
Composition: 99,999 % dry H2 Over current shut down: 12 A
H2 Pressure: 5,8 - 6,5 PSI Over temperature shut down: 65 °C
Price in Euro: 1.375,-
Description:
The H-300 PEM fuel cell system includes a rated 300 W air-cooled, air-breathing
and self-humidified PEM fuel cell stack with integrated fan and aluminium casing,
and electronic controls. The fuel cell weighs only 2000 g and measures only
324 x 109 x 94 mm. At maximum power output, the H-300 system consumes
4,2 l of H2 per minute, and has a peak power of 330 W.
Specification and Price:
Number of cells: 72 Humidification: self-humidified
Rated power: 300 W Cooling: air (integrated cooling fan)
Performance: 43 V at 7,2 A Weight (with fans & casing): 2,0 kg
H2 supply valve voltage: 12 V Dimensions with fans: 324 x 109 x 94 mm
Purging valve voltage: 12 V Flow rate at rated output: 4,2 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 40 % at 43 V
External temperature: 5 ° - 30 °C Controller: 400 g
Max. stack temperature: 65 °C Low voltage shut down: 36 V
Composition: 99,999 % dry H2 Over current shut down: 12 A
H2 Pressure: 5,8 - 6,5 PSI Over temperature shut down: 65 °C
Price in Euro: 1.900,-
Description:
The new H-500 is the lightest, most compact (and most competitively priced) 500 W system in the
global market and features an integrated LCD screen. We deliver systems to engineers and
researchers within large corporations, government organizations, research institutes and
universities around the world. They are known to be the world's lightest, most compact, and most
affordable units worldwide. The fuel cells are simple, air-breathing, air-cooled, self-humidified
systems that limit peripherals to the bare minimum. The new H-500 500 W system is a semi-
integrated unit that comes in a kit format for more integration flexibility.
Specification and Price:
Number of cells: 36 Humidification: self-humidified
Rated power: 500 W Cooling: air (integrated cooling fan)
Performance: 21 V at 24 A Weight (with fans & casing): 2,8 kg
H2 supply valve voltage: 12 V Dimensions with fans: 250 x 190 x 75 mm
Purging valve voltage: 12 V Flow rate at rated output: 6,5 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 40 % at 21 V
External temperature: 5 ° - 30 °C Controller: 450 g
Max. stack temperature: 65 °C Low voltage shut down: 18 V
Composition: 99,999 % dry H2 Over current shut down: 30 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 2.675,-
Description:
The new H-1000 is the lightest, most compact (and most competitively priced) 1 kW system in the
global market and features an integrated LCD screen. We deliver systems to engineers and researchers
within large corporations, government organizations, research institutes and universities around the
world. They are known to be the world's lightest, most compact, and most affordable units worldwide.
The fuel cells are simple, air-breathing, air-cooled, self-humidified systems that limit peripherals to the
bare minimum. The new H-1000 1 kW system is a semi-integrated unit that comes in a kit format for
more integration flexibility.
Specification and Price:
Number of cells: 72 Humidification: self-humidified
Rated power: 1000 W Cooling: air (integrated cooling fan)
Performance: 43 V at 23,5 A Weight (with fans & casing): 4,2 kg
H2 supply valve voltage: 12 V Dimensions with fans: 324 x 220 x 122 mm
Purging valve voltage: 12 V Flow rate at rated output: 14 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 40 % at 43 V
External temperature: 5 ° - 30 °C Controller: 450 g
Max. stack temperature: 65 °C Low voltage shut down: 36 V
Composition: 99,999 % dry H2 Over current shut down: 30 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 3.150,-
Description:
The new H-2000 is the lightest, most compact (and most competitively priced) 2 kW system in the
global market and features an integrated LCD screen. We deliver systems to engineers and
researchers within large corporations, government organizations, research institutes and universities
around the world. They are known to be the world's lightest, most compact, and most affordable
units worldwide. The fuel cells are simple, air-breathing, air-cooled, self-humidified systems that limit
peripherals to the bare minimum. The new H-2000 2 kW system is a semi-integrated unit that
comes in a kit format for more integration flexibility.
Specification and Price:
Number of cells: 48 Humidification: self-humidified
Rated power: 2000 W Cooling: air (integrated cooling fan)
Performance: 28,8 V at 70 A Weight (with fans & casing): 7,7 kg
H2 supply valve voltage: 12 V Dimensions with fans: 250 x 160 x 220 mm
Purging valve voltage: 12 V Flow rate at rated output: 29 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 45 % at 28,8 V
External temperature: 5 ° - 30 °C Controller: 1000 g
Max. stack temperature: 65 °C Low voltage shut down: 24 V
Composition: 99,999 % dry H2 Over current shut down: 75 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 5.900,-
Description:
The new H-3000 is the lightest, most compact (and most competitively priced) 3 kW system in the
global market and features an integrated LCD screen. We deliver systems to engineers and
researchers within large corporations, government organizations, research institutes and
universities around the world. They are known to be the world's lightest, most compact, and most
affordable units worldwide. The fuel cells are simple, air-breathing, air-cooled, self-humidified
systems that limit peripherals to the bare minimum. The new H-3000 3 kW system is a semi-
integrated unit that comes in a kit format for more integration flexibility.
Specification and Price:
Number of cells: 72 Humidification: self-humidified
Rated power: 3000 W Cooling: air (integrated cooling fan)
Performance: 43,2 V at 70 A Weight (with fans & casing): 11,0 kg
H2 supply valve voltage: 12 V Dimensions with fans: 380 x 160 x 280 mm
Purging valve voltage: 12 V Flow rate at rated output: 42 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 45 % at 43,2 V
External temperature: 5 ° - 30 °C Controller: 1000 g
Max. stack temperature: 65 °C Low voltage shut down: 36 V
Composition: 99,999 % dry H2 Over current shut down: 75 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 8.250,-
Description:
The new H-4000 is the lightest, most compact (and most competitively priced) 4 kW system in
the global market and features an integrated LCD screen. We deliver systems to engineers
and researchers within large corporations, government organizations, research institutes and
universities around the world. They are known to be the world's lightest, most compact, and
most affordable units worldwide. The fuel cells are simple, air-breathing, air-cooled, self-
humidified systems that limit peripherals to the bare minimum. The new H-4000 4 kW system
is a semi-integrated unit that comes in a kit format for more integration flexibility.
Specification and Price:
Number of cells: 96 Humidification: self-humidified
Rated power: 4000 W Cooling: air (integrated cooling fan)
Performance: 57,6 V at 70 A Weight (with fans & casing): 14,0 kg
H2 supply valve voltage: 12 V Dimensions with fans: 380 x 160 x 360 mm
Purging valve voltage: 12 V Flow rate at rated output: 58 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 45 % at 57,6 V
External temperature: 5 ° - 30 °C Controller: 1000 g
Max. stack temperature: 65 °C Low voltage shut down: 48 V
Composition: 99,999 % dry H2 Over current shut down: 75 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 10.200,-
Description:
The new H-5000 is the lightest, most compact (and most competitively priced) 5 kW system in the
global market and features an integrated LCD screen. We deliver systems to engineers and
researchers within large corporations, government organizations, research institutes and universities
around the world. They are known to be the world's lightest, most compact, and most affordable units
worldwide. The fuel cells are simple, air-breathing, air-cooled, self-humidified systems that limit
peripherals to the bare minimum. The new H-5000 5 kW system is a semi-integrated unit that comes
in a kit format for more integration flexibility.
Specification and Price:
Number of cells: 120 Humidification: self-humidified
Rated power: 5000 W Cooling: air (integrated cooling fan)
Performance: 72 V at 70 A Weight (with fans & casing): 17,0 kg
H2 supply valve voltage: 12 V Dimensions with fans: 380 x 160 x 460 mm
Purging valve voltage: 12 V Flow rate at rated output: 70 l/min
Blower voltage: 12 V Start up time: immediate
Reactants: hydrogen and air Efficiency of stack: 40 % at 72 V
External temperature: 5 ° - 30 °C Controller: 1000 g
Max. stack temperature: 65 °C Low voltage shut down: 60 V
Composition: 99,999 % dry H2 Over current shut down: 75 A
H2 Pressure: 7,2 - 9,4 PSI Over temperature shut down: 65 °C
Price in Euro: 11.800,-
Description:
Technical Data:
1. 0 ... 10 bar
2. 10 ... 15 bar
3. 15 ... 40 bar
Flow: adjustable
Range of temperature: - 10 °C … 80 °C
Connections
Weight: approx. 10 kg
Description:
The reformer technology opens PEM fuel cells the door to commercial fuels and the exisiting fuel
infrastructure.With our unique and patented FLOX reforming process, we offer the key to simple and
cost effective PEM fuel cell systems.
Based on the benefits of FLOX®-Reformer compact C1, the FPM-C1 offers easy systemintegration
to the customer: all BOP-components, the desulfurization- unit and the water treatment system are
scope of supply. Our contribution to cost-reduction.
Features:
· Minimised space requirement · Optimised insulation · Load change in seconds · Increased reformate pressure without gas compressor
Reformer Compact C1
Description:
The reformer technology opens PEM fuel cells the door to commercial fuels and the exisiting fuel
infrastructure.With our unique and patented FLOX reforming process, we offer the key to simple and cost
effective PEM fuel cell systems.
The product line FLOX®-Reformer compact is designed for PEM-fuel cell systems in the range from 1-10
kWel in 3 sizes. The compact design, realised by the thermal integration of reformer, evaporator and
CO-Shift in one housing offers new freedom in the architecture of the fuel cell system.
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and
unique techniques of alloy loading the HB-SCF-0010-Q is one the most advanced
hydrogen storage system. The HB-SCF-0010-Q can safely store hydrogen in the solid
state and release it steadily at ambient temperature without additional energy source - an
important issue for fuel cell application. The enhanced discharge gas flow rates of the HB-
SCF-0010-Q make it a highly competitive gas supply source for various PEM fuel cells (up
to 5 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully hydrogen charged tanks do not result
in any combustible reaction, which clearly demonstrates the safety level of the product. Unlike the high-pressure hydrogen
cylinders, here hydrogen is bonded with the alloy chemically. So, it will take hours, before the system will release it fully in
event of gas leakage caused by system’s damage. The system life cycle is incredibly long – our storage is able to pass few
thousand charge/discharge cycles without any essential changes in working technical characteristics.
While charge with only 99,99 % purity hydrogen the HB-SCF-0010-Q is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SCF-0010-Q an ideal pure hydrogen source for Fuel Cell systems, that is in addition easy to use
and very safe.
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and unique
techniques of alloy loading the HB-SCF-0050-Q is one the most advanced hydrogen storage
system. The HB-SCF-0050-Q can safely store hydrogen in the solid state and release it steadily at
ambient temperature without additional energy source - an important issue for fuel cell
application. The enhanced discharge gas flow rates of the HB-SCF-0050-Q makes it a highly
competitive gas supply source for large variety of PEM fuel cells (from 1 W up to 20 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully hydrogen
charged tanks do not result in any combustible reaction, which clearly demonstrates the safety
level of the product. Unlike the high-pressure hydrogen cylinders, here hydrogen is bonded with
the alloy chemically. So, it will take hours, before the system will release it fully in event of gas
leakage caused by system’s damage. The system life cycle is incredibly long – our storage is able to pass few thousand
charge/discharge cycles without any essential changes in working technical characteristics.
While charge with only 99,99 % purity hydrogen the HB-SCF-0050-Q is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SCF-0050-Q an ideal pure hydrogen source for Fuel Cell systems, that is in addition easy to use
and very safe.
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 0,5 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and unique
techniques of alloy loading the HB-SCF-0100-Q is one the most advanced hydrogen storage
system. The HB-SCF-0100-Q can safely store hydrogen in the solid state and release it steadily
at ambient temperature without additional energy source - an important issue for fuel cell
application. The enhanced discharge gas flow rates of the HB-SCF-0100-Q makes it a highly
competitive gas supply source for large variety of PEM fuel cells (from 20 W up to 100 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully
hydrogen charged tanks do not result in any combustible reaction, which clearly demonstrates
the safety level of the product. Unlike the high-pressure hydrogen cylinders, here hydrogen is
bonded with the alloy chemically. So, it will take hours, before the system will release it fully in
event of gas leakage caused by system’s damage. The system life cycle is incredibly long – our storage is able to pass few
thousand charge/discharge cycles without any essential changes in working technical characteristics.
While charge with only 99,99 % purity hydrogen the HB-SCF-0100-Q is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SCF-0100-Q an ideal pure hydrogen source for Fuel Cell systems, that is in addition easy to use
and very safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 0,5 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and
unique techniques of alloy loading the HB-SCF-0300-N is one the most advanced
hydrogen storage system. The HB-SCF-0300-N can safely store hydrogen in the solid
state and release it steadily at ambient temperature without additional energy source - an
important issue for fuel cell application. The enhanced discharge gas flow rates of the HB-
SCF-0300-N makes it a highly competitive gas supply source for large variety of PEM fuel
cells (from 30 W up to 150 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully
hydrogen charged tanks do not result in any combustible reaction, which clearly demonstrates the safety level of the product.
Unlike the high-pressure hydrogen cylinders, here hydrogen is bonded with the alloy chemically. So, it will take hours, before
the system will release it fully in event of gas leakage caused by system’s damage. The system life cycle is incredibly long – our
storage is able to pass few thousand charge/discharge cycles without any essential changes in working technical
characteristics.
While charge with only 99,99 % purity hydrogen the HB-SCF-0300-N is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SCF-0300-N an ideal pure hydrogen source Fuel Cell systems, that is in addition easy to use and
very safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 1,0 (25 °C) MPa
Hydrogen discharge flow rate**: 0,5 - 1,5 (1,5 - 3,0 in water bath) 25 °C
Description:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 0,5 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and unique
techniques of alloy loading the HB-FR07-0500-B is one the most advanced hydrogen sto-
rage system. The HB-FR07-0500-B can safely store hydrogen in the solid state and release it
steadily at ambient temperature without additional energy source - an important issue for
fuel cell application. The enhanced discharge gas flow rates of the HB-FR07-0500-B make it
a highly competitive gas supply source for large variety of PEM fuel cells (up to 150 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully
hydrogen charged tanks do not result in any combustible reaction, which clearly
demonstrates the safety level of the product. Unlike the high-pressure hydrogen cylinders,
here hydrogen is bonded with the alloy chemically. So, it will take hours, before the system will release it fully in event of gas
leakage caused by system’s damage. The system life cycle is incredibly long – our storage is able to pass few thousand
charge/discharge cycles without any essential changes in working technical characteristics.
While charge with only 99,99 % purity hydrogen the HB-FR07-0500-B is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-FR07-0500-B an ideal pure hydrogen source Fuel Cell systems, that is in addition easy to use and
very safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 0,5 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and
unique techniques of alloy loading the HB-SCF-0660-N is one the most advanced
hydrogen storage system. The HB-SCF-0660-N can safely store hydrogen in the solid state
and release it steadily at ambient temperature without additional energy source - an
important issue for fuel cell application. The enhanced discharge gas flow rates of the HB-
SCF-0660-N makes it a highly competitive gas supply source for large variety of PEM fuel
cells (from 100 W up to 400 W).
At present, this type of storage is considered as safest one. Even gunshot tests with fully
hydrogen charged tanks do not result in any combustible reaction, which clearly demonstrates the safety level of the product.
Unlike the high-pressure hydrogen cylinders, here hydrogen is bonded with the alloy chemically. So, it will take hours, before
the system will release it fully in event of gas leakage caused by system’s damage. The system life cycle is incredibly long – our
storage is able to pass few thousand charge/discharge cycles without any essential changes in working technical
characteristics.
While charge with only 99,99 % purity hydrogen the HB-SCF-0660-N is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SCF-0660-N an ideal pure hydrogen source Fuel Cell systems, that is in addition easy to use and
very safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 1,0 (25 °C) MPa
Description:
HB-PR2400 is a hydrogen storage system, based on the latest achievements in solid metal
hydride technology of AB5-type alloys as well as on unique techniques of alloy loading. It
allows to store and release the gas at ambient temperature and at designed pressure
range from 1 up to 5 atm with very high stability of gas flow: 95 % of stored gas can be
released with designed maximum flow rate at almost constant temperature.
At present, this type of storage is considered as safest one: even gunshot tests with full
hydrogen charged tanks do not result in any combustible reaction, which clearly
demonstrates the safety level of the product. Unlike to high-pressure hydrogen storages,
here hydrogen is bonded with the alloy chemically. So, it will take hours, before the system
will release it fully in event of gas leakage cased by system’s damage. The system is able to
pass a few thousand charge/discharge cycles without any essential changes in working
technical characteristics, while exploited properly.
In addition to this HB-PR2400 is capable to provide high purity hydrogen (over 99,9999 %) while for charging only 99,99 %
purity hydrogen is required. It makes HB-PR2400 an ideal pure hydrogen source for Gas Chromatography and many other
gas purity-sensitive systems.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 0,5 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and
unique techniques of alloy loading the HB-SS3300 is one the most advanced hydrogen
storage system. The HB-SS3300 can safely store hydrogen in the solid state and release it
steadily at ambient temperature without additional energy source - an important issue for
fuel cell application. The enhanced discharge gas flow rates of the HB-SS3300 makes it
a highly competitive gas supply source for large variety of PEM fuel cells (from 500 W up
to 1 kW).
At present, this type of storage is considered as safest one. Even gunshot tests with fully
hydrogen charged tanks do not result in any combustible reaction, which clearly demonstrates the safety level of the product.
Unlike the high-pressure hydrogen cylinders, here hydrogen is bonded with the alloy chemically. So, it will take hours, before
the system will release it fully in event of gas leakage caused by system’s damage. The system life cycle is incredibly long – our
storage is able to pass few thousand charge/discharge cycles without any essential changes in working technical
characteristics.
While charge with only 99,99 % purity hydrogen the HB-SS3300 is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SS3300 an ideal pure hydrogen source Fuel Cell systems, that is in addition easy to use and very
safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 1,0 (25 °C) MPa
Description:
With the latest achievements in solid metal hydride technology of AB5-type alloys and unique
techniques of alloy loading the HB-SS16500 is one the most advanced hydrogen storage system.
The HB-SS16500 can safely store hydrogen in the solid state and release it steadily at ambient
temperature without additional energy source - an important issue for fuel cell application. The
enhanced discharge gas flow rates of the HB-SS16500 make it a highly competitive gas supply
source for large variety of PEM fuel cells (up to 5 kW).
At present, this type of storage is considered as safest one. Even gunshot tests with fully hydrogen
charged tanks do not result in any combustible reaction, which clearly demonstrates the safety
level of the product. Unlike the high-pressure hydrogen cylinders, here hydrogen is bonded with
the alloy chemically. So, it will take hours, before the system will release it fully in event of gas
leakage caused by system’s damage. The system life cycle is incredibly long – our storage is able
to pass few thousand charge/discharge cycles without any essential changes in working technical characteristics.
While charge with only 99,99 % purity hydrogen the HB-SS16500 is capable to provide high purity hydrogen (over
99,9999 %). It makes HB-SS16500 an ideal pure hydrogen source Fuel Cell systems, that is in addition easy to use and very
safe.
Specification and Price:
Hydrogen discharging pressure (at 25 °C): > 0,1; ≤ 1,0 (25 °C) MPa
3. Prepayments are required until credit has been established. All first time orders
must be prepaid. Any order over 10.000 must be 50 % prepaid.
6. Customers who cancel their purchase orders will be responsible for 50% of the
original price of the order.
Payment of QuinTech e. K.
4. Conditions of payment, price alterations, compen- 7. Industrial proprietary rights, tools, secrecy
sation for returned goods 7.1 As regards any moults, samples, diagramms, technical docu-
4.1 Prices quoted shall be ex-works prices. Charges for packing ments, price estimates or offers, we reserve ownership and all
and freight shall be at the customer`s expense. Invoice shall be industrial proprietary rights and copyrights. It is not allowed to
paid in full, net, due at the indicated date, free of charges for us reproduce them without our agreement. The customer may use
in Euro, to our account in the Federal Republic of Germany. We them only in the agreed way. The contractual goods may not,
shall accept bills of exchange or cheques only with a view to without our agreement in writing, be produced by the customer
performance at the customer`s expense. For new customers or are on his behalf.
customers with which we do not do business regulary, in case of 7.2 If we deliver products in accordance with drawings, models
delay in payment regarding a previous delievery or if there are or samples provided by the customer, he shall take responsibility
good reasons for doubting the customer`s credit-worthiness, we on our behalf that in producing and delivering the goods, we
reserve the right to make each individual delievery dependent on shall not be infringing the industrial property rights or other rights
payment in advance or on lodging of security to the invoice of third parties, and shall pay – should the situation arise – any
amount. compensa-tion to us for any obligation which may arise from
4.2 All invoices are due within 10 days of shipping. Finance such infringements of rights, including our own efforts.
charges on past due invoices are 5 % annually upon the German 7.3 Any knowledge which is not public knowledge and which the
Basiszins. customer has acquired through the business connexion must be
4.3 In case of delay of payment of an invoice, the total amount kept secret in respect of third parties.
of the customers liabilities towards us shall be payable
immediately, and we shall be released from our obligations to
effect any further delivery resulting from any current contract of
delivery. Any period allowed for payment shall be discontinued