You are on page 1of 3

Market Leading Heat Recovery Ventilation

Energy Saving

UP TO 93% HEAT
RECOVERY
Low Carbon EFFICIENCY.

Improved Air Quality

Combining market leading heat exchange efficiency with extremely low energy usage,
the aircycle 1.2 provides superior air comfort levels whilst minimising heat wastage. HIGH PERFORMANCE IN A COMPACT PACKAGE
Despite its size, the aircycle 1.2 is one of the best performing Heat Recovery Ventilation units in its
SUPERIOR AIR QUALITY class and is both SAP Appendix Q Approved and Energy Savings Trust ‘Best
The aircycle 1.2 operates by recovering heat from air that would normally be expelled into the Practice’ compliant. Its efficient performance significantly contributes to lower Dwelling Emission
atmosphere. This heat is transferred to fresh air drawn into the property, which is then filtered and Rates (DER’s) in SAP and is suitable for use in homes being built to levels 3,4,5 and 6 of the Code for
distributed throughout. Sustainable homes.

The aircycle 1.2 can significantly reduce the space heating bill of a domestic dwelling, whilst also AUTOMATIC CLIMATE REGULATION
delivering a healthier and more comfortable environment for the occupier. The aircycle 1.2 eliminates Sophisticated in-built technology enables the unit to respond intuitively to a range of internal and
many issues caused by poor indoor air quality within the home such as condensation and the
external temperature changes. The aircycle 1.2 offers in-built automatic frost protection and
resultant formation of ‘black mould’. Additionally, the advanced air filtration system ensures the home
humidity controls that respond to extreme cold spells and changes in humidity within the
environment is much more conducive to allergy and asthma sufferers alike.
dwelling, protecting the unit whilst ensuring a comfortable indoor environment for the occupier.

More Features The aircycle 1.2 also has the option of being supplied complete with a unique in-built ‘Tempering’
Summer Bypass suitable for warmer regions. Unlike most other Heat Recovery Units which offer
Tempering Summer Bypass Standard
simply a 100% Summer Bypass at a defined temperature, the Brookvent ‘Tempering’
Up to 93% Heat Efficiency
Down to 0.53 W/L/S SFP Summer Bypass operates on a linear scale between 20 Degrees Celsius (No Summer Bypass)
100% Variable Fan Speed Easy Access Filters (G2/3) and 27 Degrees Celsius (Full Summer Bypass). This gradually increases the amount of air directed
Independent Fan Speed Control Wall Mount around the Heat Recovery Core ensuring the delivery of a comfortable indoor environment for the
Express-fit Mounting Bracket occupier.
Light Weight, Impact Resistant
EPP Construction
SAP Approved VENTILATION SIMPLICITY
The aircycle 1.2 succeeds in making Heat Recovery Ventilation Installation much simpler. Supplied
Optional
Ceiling or Floor mount complete with a flying lead, the unit can be easily connected to a power supply. 100% variable
fan speed ensures precise commissioning through independent fan adjustment. Maintenance has
Integral Humidistat also been made much simpler with the only requirement being a regular filter change (every 9-12
months). The filters on the new aircycle 1.2 can be quickly and easily accessed via the airtight tabs on
the front of the unit.
Automatic Frost
Protection

manufactu
ar

ye

rer
s warran
NT
Timed Boost Facility

VE
y manufactured

t
BROOK

A range of compatible ducting and ancillaries are also available. Please enquire for further details. Brookvent operate a policy of continuous innovation and thus reserve the right to alter product specifications and appearances without notice.
SPECIFICATION
Dimensions 583mm x 600mm x 337mm
Weight 10kg
Materials Main enclosure: Impact Resistant EPP (Expanded Polypropylene)
PCB Enclosure: Nylon 6 V0
Drainage Tray: HIPS
Filters: Polyester Media (G2/3)
Mounting Bracket: Zinc Plated Steel
Electrical 240V EC
EC Low Energy Fans
Supplied with a flying lead
Controls Extremely efficient in-built control board (SAP Q Approved)
Independent Fan Speed Control (Trickle and boost settings for each fan)
Single 240v boost input (Light Switch, Humidistat, PIR, etc) 15 Min Over-run
In-built Humidity Sensor (Boost activation) Variable: 60% - 90% RH, Factory Set: 70%
Frost Protection, Variable Activation: 0 – 10 Degrees Cel., Factory Set: 5 Degrees Cel.
Optional ‘Tempering’ Summer Bypass (Variable between 20 and 27 Degrees Cel.)
Installation Wall mount. Ceiling and Floor mount versions are also available.

Standards Fully complies with Building Regulations for UK & Ireland | SAP Q Approved
Energy Savings Trust Best Practice | CE

Specific Fan Power: From 0.53 w/l/s


Heat Recovery Efficiency: Up to 93% Efficiency
Guarantee Period: 5 Years

SAP APPENDIX Q: APPROVED RESULTS

Specific Fan Power Heat Exchange


Configuration (W/l/s) Efficiency (%)

Kitchen + 1 Wet Room 0.53 93


Kitchen + 2 Wet Rooms 0.57 91
Kitchen + 3 Wet Rooms 0.67 90
Kitchen + 4 Wet Rooms 0.82 89
Kitchen + 5 Wet Rooms 0.97 88
Kitchen + 6 Wet Rooms 1.16 87

ACOUSTIC PERFORMANCE
Standard Configuration
Inverted Configuration

Extract to
Fresh outside
from
outside Fresh to
Extract
from home
house

Extract
from
FRONT house

Extract to
outside Fresh
AIRFLOW PERFORMANCE CURVE from
outside
Fresh to
home

Brook House
Dunmurry Industrial Estate
Dunmurry
Belfast BT17 9HU
t: +44 (0) 28 9061 6505
f: +44 (0) 28 9061 6518

e: info@brookvent.co.uk www.brookvent.co.uk

You might also like