You are on page 1of 4
iF lash 1800 Unique Workstation Consolidation for the Average Lab Bench top size, top notch performance when compared to similar analyzers Less outsourced samples, more in-house controlled quality Eradication of the classical ELISA waste while obtaining results faster For the average lab, iFlash 1800 can do whatever the classical ELISA cannot dream of YHLO YHLO iFlash 1800 Tailored Automation to Average Labs Top Notch Performance Features Attriloutes Top Notch Workstation Consoli Features - Attributes + Upto 180 tests/hour 50 sample positions with STAT 20 refrigerated reagents onboard 500 cuvettes loading in seconds Continuous loading of reagents, samples and consumables, no interruption of the routine work ~ “a ‘Automation made affordable for average lab Results in minutes and not in hours as per classical Elisa jation 118 reagents, same as IFlash 3000 Complete hormonology assortment, Autoantibodies: and infectious diseases related panel matching classical Elisa Sample rack compatible with iFlash 3000 Replaces the dedicated analyzers Replaces the classical Elisa analyzers Top Notch “In Lab” Quality Features Attributes Tailored pack for consumables Minimized outsourcing, quality of results directly controlled by the lab More routines in house iFlash 1800 Speci General information Throughput Up to 180 tests/hour Time to First Result 12 minutes Detection Principle Magnetic particle-based direct chemiluminescence Luminescence Label Aeridinium Ester ‘Test Method Sandwich, competitive, indirect ‘Sample Supply System Sample Position 5 samples per rack, 60 sample positions with STAT function ‘Sample Tube Microcup and blood collecting tube Sample Volume SuL~150uL Cuvettes Loader Capacity 00, allows continuous loading Reagent System Reagent Position 20 positions with onboard refrigeration Reagent Carousel Temperature 2-80 Reagent Detection Reagent level tracking Reagent Pack 100 tests per kit Auto Dilution ‘Maximum of 1:400 (for valid test) Reaction Carousel Capacity Able to hold 75 reaction cuvettes Incubation Temperature 37.0°C:£0.3°C, with a fluctuation of 0.1°C Mixing System Non-contact eccentric vortex mixer Magnetic Separation System Washing Method 4-step magnetic Separation Temperature 87.0°C£0.3°C, with a fluctuation of 0.1°C ‘Operating Conditions Power Supaly 100-240v, 50/60Hz Power Consumption 1000VA Temperature 10-30°C ‘Temperature Fluctuation = 42°C/h Ambient Humidity 20%RH-70%RH (without condensation) Physical Dimensions 103cm(L)X7Sem(W)x71¢m(H) Weight 150k9 EE——————EEEEE iFlash Test Panels YHLO Main Stream Reproductive Hormonology Autoimmunity Heel Infection Thyroid Rheumatoid Arthritis, Fertility EBV TSH Anti-COP AM EBVGAIgG Anti-TPO RF IgG inhibin EBVCAIgM Anti-TSHR * RF IgM Inhibin A EBVOA IgA To RF Hl EBEA IgM Anti-T@ RAI 196 FSH EBNAIGG Fra Hea EBNAIQA Fra Connective Tissue Disease Prolactin 13 ANA DHEA-S Respiratory Di v4 dsDNA IgG ues Mycoplasma pn. laG SmigG e2 Mycoplasma pn. IgM Tumor Markers SS-Alga PAPP-A Chlamyaia pn. IgG Pal 88-8196 free betaHoG Chlamyaia pn. IgM Pail Scl-70 IgG Progesterone AFP. Jo-1 198 Testosterone Blood Bank CEA RNP70 Iga Anti-TP cat25 ToRcH Anti-HCV* CAt8-3° ‘Autoimmune Liver Toxo |g HBsAg’ CAat9-9 SMA IgG Toxo laM Anti-HBs * Froo PSA AMA-M2 cMViga HBeAg* Total PSA CMV IgM Anti-HBe* OYFRA21-1 Vasculitis Diagnostics HSV-119@ Anti-HBo* NSE PRI IgG HSV-2 IgG HIVCombo* GBM IgG HSV-1 toM ‘Anemia MPOIsG HSV-2 10M Inflammation Ferritin RubelialgG Pot Folate* Autoimmune Diabetes Rubella lgM Vitamin 812° 1a-20 Cardiac Markers ck-MB Myoglobin Troponin-| BNP Bone Metabolism 25-OH Vitamin D PTH Metabolism Insulin C-Peptide Cortisol ACTH Adiponectin Li HA PIIIPN-P cw Laminin F Fibrosis TAK GADA ICA ZnTBA* Anti-Phospholipid Syndrome CardiolipinigG Cardiolipin ia Cardiolipin igA ‘Anti-Cardiolipin B2-Giycoprotein | IgG £B2-Glycoprotein! IgA B2-Glycoprotein IgM Anti-B2-Glycoprotein |

You might also like