Annexure- 2

Design of Pumping Machinery for lifting water from source to


Proposed/existing RCC Sump.
Data :
1 Population as per Census 2001 7868 Souls
2 Present population in the year of 2010 13376 Souls
3 Intermediate stage population in the year of 2025 16720 Souls
4 Ultimate stage population in the year of 2040 20063 Souls
5 Rate of water supply 70 lpcd
Designing pumping machinery for intermediate stage requirements
6 Intermediate stage water requirement 1170365 lpd
7 Pumping hour /day 6 hrs
15 Rate of lifting water 3251.02 lpm
54.18 lps
16 Total pumping in 24 hours 4681469 lpd
= 4.68 mld
17 Static Head
a. GLRL near Source = 79.79 M
b. Lowest water level in bore/well = 72.35 M
c. FSL of proposed ESR/Cistern/Sump = 84.00 M
d. Static lift = 11.65 M
18 Friction losses
a. Dia of rising main = 160 MM
b. Type & class of pipe = PVC
c. Length of rising main = 8000 Rmt
d. Loss of head per 1000 M for C=140 = 2.24 M
e Veloity of flow = 0.77 mps
f Total loss of head in 1000 M long rising main = 17.92 M
19 Residual head = 2.00 M
20 Other losses = 1.79 M
21 Total head required = 33.36 M
Say = 35.00 M
22 Designing the capacity of motor required
Wx H
BHP =
75
54.18 x 35.00 = 25.28 BHP
=
75

Considering 10 % overload and 70% efficiency of the HSCF Pumping


Machineries. capacity of motor required
25.28 x 1.1 = 39.73 BHP
=
0.7
Say = 40.00 HP
Hence it is proposed to provide 2+1 sets of Three phase HSCF pumping
machinery having following characterstics
1 Design Discharge = 1500.00 lpm
2 Design Head = 35.00 M
3 Design HP = 40.00 HP