You are on page 1of 2

VITROS 5600 Integrated System1

®
“Results matter.”
Specifications Sheet

Measurement Principle: Calibration:


+ Colorimetric/Rate + Up to 25 lots per assay with automatic lot switching
+ Potentiometric (direct ISEs) + MicroSlide and MicroTip assays stable up to lot change
+ Immuno-rate + MicroWell stable for up to 28 days
+ Turbidimetric + Random-access calibration
+ Enhanced Chemiluminescence + Bar-coded calibrators for MicroSlide and MicroWell assays

Reagents: System Startup:


+ No preparation*, no mixing or reconstitution + 24-hour ready mode
required for Integrated Reagent Packs, Signal + No manual primes, purges, washes or tubing
Reagent, Universal Wash Reagent, Electrolyte maintenance
Reference Fluid (ERF), or Immuno-Wash
Fluid (IWF) + No daily calibrations or calibration checks
+ Onboard stability up to 84 days + Automatic integrated prime/purge for
MicroWell assays
+ Shelf life stability up to 18 months from
date of manufacture** Time for Single Result:
+ Onboard test capacity: + Potentiometric: ~ 2.5 minutes
• Up to 11,440 assays + Colorimetric: ~ 6 minutes
• 150 reagent positions: + Immuno-rate: ~ 8 minutes
- 89 MicroSlide Cartridges (18, 50, or 60 tests/cart) + MicroTip: ~ 8-16 minutes
- 31 MicroWell Packs (50 or 100 tests/pack) + MicroWell: ~ 16-73 minutes
- 30 MicroTip Packs (50 or 100 tests/pack) + Real-time results data stream to LIS available
User-Defined Channels: Throughput:
+ 10 available (MicroTip) + Maximum theoretical throughput is up
to 945 tests per hour
Consumables:
+ Actual throughput will vary by test mix and
+ VersaTips, MicroTips, Cuvettes, Signal Reagent and sample workflow
Universal Wash Reagent can be replenished without
interrupting system operation. Reagents replenished Sample Types:
without interrupting incubation. ERF and IWF can
be replenished when all MicroSlides have completed + Serum, Plasma, Urine, CSF, Whole Blood,***
Amniotic Fluid****
+ Onboard capacity:
• VersaTips: 2000 Sample Volume:
• MicroTips: 384 + Per assay: 2-80μL
• Cuvettes: 348 + Dead volume: minimum 35μL
• Signal Reagent: 3 packs
Sample Capacity:
• Universal Wash Reagent: 5 liters
+ Continuous load and unload
• ERF: 800 drops
+ 80 samples in Universal Sample Trays
• IWF: 300 drops
+ 10 samples in dedicated STAT lane
Sample and Reagent Management Incorporating System Dimensions:
Intellicheck Technology:
®
+ Width: 2.79 m/110 inches
+ Single-use Tip Metering verifies sample aspiration + Depth: 0.89 m/34.9 inches
and dispense, eliminates carryover and addresses + Height: 1.73 m/68 inches
cross-contamination concerns
+ Weight: 1070.5 kg/2360 pounds
+ Clot, bubble, low and high viscosity, thin layer fluid
and short sample detection Power:
+ Save-the-Sample Clot/Bubble Management + Line Voltage: 2 dedicated 20 amp power lines
+ Liquid level sensing or 1 dedicated 30 amp power line with UPS,
nominal 200-240V AC
+ MicroSlide, MicroWell and Cuvette Dispense Verification
+ Line Frequency: 47-63 Hz
+ Reagent aspiration and dispense verifications
+ Onboard IntelliReport provides complete traceability Environment:
and documentation of result quality + Operating temperature: 15°-30°C/59°-86°F

Sample Containers: + Ambient relative humidity: 15%-75% RH

+ Universal Sample Trays accommodate: + Altitude: up to 2,439 m/8,000 feet

• 5mL, 7mL, 10mL collection tubes + Plumbing: No water or drain required; self-contained
onboard waste management eliminates
• 1.5mL micro-collection containers special requirements for off-board plumbing
• VITROS® microsample cups and 0.5mL and
2.0mL cups Communications:
+ Laboratory Information System (LIS):
Sample Bar Code Identification:
• Bidirectional interface for ASTM and HL7
+ Autodiscriminates by simultaneously recognizing protocols
all standard symbologies:
• Broadcast download and Host Query
• Code 128
• Results can be uploaded individually or as an
• ISBT 128 entire sample
• Code 39 + Laboratory Automation System (LAS):
• Codabar • AT ready at launch
• Interleaved 2 of 5 • 2 LAS interfaces, point-in-space
Dilution Capabilities: + Ports:
+ Auto reflex dilution • RS 232 serial ports (for LIS and LAS)
+ Operator requested dilution • USB ports (for printers)
+ Off-board dilution calculation • Ethernet ports (for e-Connectivity,™ LIS)

Automatic Reflex Testing (based on user-configuration): e-Connectivity™ Interactive System Management:


+ Reflex to different assays + Using the facility’s Internet connection or
+ Reflex to the same assay DSL, VPN establishes a secure connection
between system and Ortho Clinical Diagnostics
Operator Interface: Technical Support to enhance troubleshooting
and increase uptime
+ Color-coded graphical user interface
+ Automatic two-way data exchange to automatically
+ Ergonomic flat, low-glare, LCD, 17-inch
send and retrieve data
touchscreen monitor
+ Automatic download of system software updates
+ Numeric keypad on monitor
+ Remote connectivity provides the ability to enable
+ Detached keyboard for maximum flexibility
remote diagnostics and remote control operation
+ Onboard documentation and animated Help (V-Docs)
+ Enhance uptime with predictive alerts
+ Onboard maintenance documentation

Data Storage:
1 Availability is subject to local regulatory requirements
+ Read/write disk drive for data input and archiving
* Except Caffeine
+ USB flash drive (memory stick) capabilities ** Gentamicin: 24 months; Caffeine: 36 months
*** For %Hemoglobin A1c and Red Cell Folate
+ 5,000 sample programs **** Not commercially available in the United States
+ 25,000 samples with ability to archive and
retrieve through CD-ROM or USB flash drive

www.orthoclinical.com
All trademarks are the property of Ortho-Clinical Diagnostics, Inc. © Ortho-Clinical Diagnostics, Inc. 2013 CL12219 OCD8950715

You might also like