You are on page 1of 3

Types 2089, 2086 & 2084

Precision Digital Test Gauge


FEATURES Socket Location: Lower (6 o’clock) 3 and 9 o’clock
• Industry Leading Accuracy Mounting: Stem (standard), Panel (optional)
Ranges: Vac. thru 7000 psi (see engineering units below
• Breakthrough Display Height for other units of measurement) Non-cataloged avail-
• Rugged & Portable Design able ranges on application.
Operating Temp.: 0/150°F (–18/63°C)
• Configurable Options Including: Storage Temp.: –40/180°F (–40/82°C)
- Twelve Engineering Units Temp. Corrected: Yes
- Seven Languages Proof Pressure: 200% of full scale
- Adjustable Update and
Dampen Modes DISPLAY
- Field Calibration Capability Type: LCD
- Disable Mode Display Digits: 5, 99,999 counts
Character Height: .66˝
Is your digital gauge as Backlite: Off by default
accurate as you think? Bar Graph: Yes
Gauge accuracy can be dramatically Battery Life: >1000 hrs. (3 AAA batteries included, NOT
installed)
impacted by changes in temperature,
Agency Approvals: FM/CSA approval not available on
re-zeroing of gauges and other factors. Until vacuum ranges and compound ranges up to 15 psi
now there has been no one s­ ingle solution
to address these concerns. The Ashcroft KEYPAD FUNCTIONS
precision digital test gauge is that solution. On/Off: Manually turns unit on and off (auto off options in
­configuration menu (CONFIG) )
What you should know about digital test Backlite: Manually turns backlite on and off (auto off
options in c­ onfiguration menu (CONFIG) )
LOOK FOR THESE AGENCY MARKS ON OUR PRODUCTS gauge accuracy…“Terminal Point” ver- Min/Max: Stores min. and max. values when displayed
sus “Best Fit Straight Line Accuracy.” Zero/Clear: Zeros display or clears min. and max. values
Ambient Temperature Changes when displayed
Enter: Selects items in configuration menu (CONFIG)
Other manufacturers of digital gauges may
Configuration Mode (CONFIG): Allows scrolling through
­specify operating temperature range with-
tal configuration menus to select available options
.05% To nd out specifying the additional error associ- Engineering Units: psi,˝Hg, ˝H2O, ftSW, Bar, mBar, kPa,
a
ErrorcorrBected full-scale ated with changes in ambient temperature. mPa, mmHg, cmH2O, mmH2O, kg/cm2
Update Rate: Four Options: 10x/sec, 5x/sec, 2x/sec, 1x/
ture racy Errors can range as high as .04%/°F. A
Tempera inal-point accu sec
term
from 0 to
150°F 25°F change from an ambient of 70°F may
Auto Off: Five Options: Never, 2 min., 5 min., 15 min.,
add an additional 1% to the s­ tated accura- 30 min.
cy of the gauge! The Ashcroft digital gauge Dampening: Five Options: None, average 2, 4, 6, 8
with total error band ensures accuracy from readings
0-150°F. Language: Seven Languages: English, Spanish, French,
Italian, German, Portuguese, Dutch
Backlite: Five Options: On/off, 10 sec., 30 sec.,
PRODUCT SPECIFICATIONS 1 min., 5 min.
Type: 2089 (0.05% F.S. accuracy), 2086 (0.10% F.S. Calibrate: Zero and Span (password protected)
accuracy), 2084 (0.25% F.S. accuracy) Zero Disable: Allows for disabling of Zero button
Accuracy: 0.05%, 0.10% or 0.25% all Full Scale, Contrast: Seven available options
Terminal Point, Total Error Band (TEB) Including Disable: Allows for “lock-out” of CONFIG options
Hysteresis, Linearity, Repeatablilty and Temperature Calibration Chart: 10 point individual calibration chart,
(0/150°F) standard for Type 2089,
Case Size: 3˝ others optional
Case Material: 300 Series Stainless Steel Standard Features: 300 Series SS Protective Cover,
Case Finish: Electropolished Protective Carrying Pouch
Case Rating: Weatherproof, IP65, NEMA 4
Case: Available with Optional Protective Rubber Boot
Wetted Parts: 316 Stainless Steel
Socket Size: 1⁄4 NPT Male, (contact factory for other
options)

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN DTG-1 © Ashcroft Inc. 2017 Rev. A 07/17 email: info@ashcroft.com • www.ashcroft .com
Types 2089, 2086 & 2084
Precision Digital Test Gauge
IS YOUR DIGITAL GAUGE AS  What you should know about The Bottom Line…
ACCURATE AS YOU THINK? digital test gauge accuracy…
Ashcroft Digital Test Gauge
Gauge accuracy can be dramatically impacted Terminal Point versus Best Fit Accuracy Includes
by changes in temperature, re-zeroing of gaug- Straight Line Accuracy. Linearity Total Error Band
U    
es and other factors. Until now there has been Ambient Temperature Changes Hysteresis U (TEB)
no one ­single solution to address these con- Other manufacturers of digital gauges may s­ pecify
Repeatability U …An Ashcroft
Temperature (0/150°F) U Exclusive
cerns. The Ashcroft precision digital test gauge operating temperature range without specifying the
Terminal Point Accuracy U
additional error associated with changes in ambient
is that solution. temperature. Errors can range as high as .04%/°F.
A 25°F change from an ambient of 70°F may add an
Unmatched Accuracy Performance additional 1% to the s­ tated accuracy of the gauge!
n .05% Full Scale Total Error Band (TEB). The Ashcroft digital gauge with total error band
ensures accuracy from 0-150°F.
INDUSTRY LEADING
Includes the effects of linearity, hysteresis,
repeatability and temperature from 0 to150°F
Ashcroft Precision Digital Gauges with CONFIGURABLE OPTIONS
Terminal Point Accuracy • UNITS of measurement –
nG  auge also available with .1% or .25% full BENEFIT
scale TEB accuracies 12 options including ˝ H2O with three
• All points between
nT  erminal point accuracy allows re-zeroing to 100% Terminal
T Point: end points (zero temperature offerings
zero and full-scale
eliminate sensor offset by a straight line will be within stated • LANGUAGES – Seven available options
PRESSURE

n 12 units of measurement accuracy


• UPDATE RATE – Four options
• Allows zeroing of
n Inches of water range for three reference • DAMPENING – Five averaging options
gauge at start-up to
temperatures: 4°C, 20°C and 60°F eliminate any sensor • PASSWORD PROTECTED
offset
INDUSTRY LEADING FEATURES 0%
RANGE 100%
– Calibration, Zero & Span
Rugged Design •D
 ISABLE – Password protected
nS  tainless steel case and socket welded for Competitive Digital Gauges with Best Fit •B ACKLITE – Five options including
strength Straight Line (BFSL) Accuracy NEVER
nP  olyester window protects display from • Linearity error mini-
100%
BFSL minimizes linearity error mized by “best” fitting •C
 ONTRAST – Seven available options
damage. by “best” fitting a straight line
to a non-linear curve a straight line to a •A UTO OFF – Five options   
nS  tainless steel cover protects keypad non-linear curve.
PRESSURE

nW  eatherproof, NEMA 4, IP65 case


n Intrinsically safe, FM/CSA approval not • BFSL gauges have
available on vacuum ranges and compound a zero offset at cali-
bration that must be
ranges up to 15 psi 0%
RANGE 100% maintained to ensure
nS  train relief to protect wiring while replacing accuracy throughout
batteries  range
nO  ptional Protective Rubber Boot.
PROBLEM
Industry Leading Display and Portable Size • Re-zeroing gauge may invalidate published .66˝ high digital display
accuracy specification
n Industry’s smallest case size (3˝) • Zero offset at start-up may
n Largest display height of .66˝ be the result of either:
n Seven languages - BFSL Calibration
n%  of range bar graph - Zero Drift

Safety Bar graph % of full scale


n The only portable digital test gauge that meets
ASME B40.7
nP  ressure range on keypad and bar graph
reduces accidental overpressure
nP  roof pressure = 2 x gauge range

Flashing display when


unit pressured beyond
range or below zero

Battery level indicator

Press to indicate minimum Range on keypad, complies


or maximum pressure with ASME B40.7, reduces
gauge has measured. the possibility of accidental
Stores minimum and ­overpressure
maximum values

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN DTG-1 © Ashcroft Inc. 2017 Rev. A 07/17 email: info@ashcroft.com • www.ashcroft .com
Types 2089, 2086 & 2084
Precision Digital Test Gauge
DIMENSIONS

3.34 4.34

0% 100%

1.70
www
.ashcr oft.com

.61

Panel Mounting .17


Dimension Drawing HOLE
CUTOUT 1.860
DIAMETER
3.406
(313⁄32 ±1⁄32)

4.00

STANDARD PRESSURE RANGES:


Compound Bar/ Compound mBar/ Absolute
psi (psi) kPa KSC (bar) mmH2O MPa cmH2O (psia)
vac. 15# & vac. –100/0 1 –1 to 0 3000 1 250 15
5 30# & vac. 25 1.6 –1 to 1 5000 1.6 300 25
10 60# & vac. 40 2.5 –1 to 2 10,000 2.5 400 50
15 100# & vac.6 60 4 –1 to 3 6 500
30 100 6 –1 to 30 40 600
60 160 10 1000
100 250 16 1600
160 400 25 2000
200 600 40 2500
300 1000 60 4000
500 160 5000
600 250 6000
800 400 10,000
1000 500
2000
2500
3000
5000
7000

TYPICAL PRODUCT CODING 1 2 3 4 5
30 – 2089 – SD – 02L – 100#
1. Dial Size: 3˝
2. Type: 2089
3. Wetted Parts: 316 SS
4. Connection: 1⁄4 NPT lower
5. Range: 100 psi

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN DTG-1 © Ashcroft Inc. 2017 Rev. A 07/17 email: info@ashcroft.com • www.ashcroft .com