DESIGN OF 2-WAY SLAB (USD) Direct Design Method


Yield strength of steel, fy 60.2 ksi 415 Mpa
Compressive strength of concrete fc' 3.6 ksi 25 Mpa Interior Negative Momen
Clear Length of Slab,L 16.2 ft 5 m l2/l1
Clear width of Slab,B 16.2 ft 5 m α1l2/l1=0
C/C Length of Slab,ln 16.8 ft 5.2 m α1l2/l1>=1
C/C Width of Slab,ls 16.8 ft 5.2 m
All direct Beam Size (h*b) 20.0 8.0 50 20
Ratio of Long & Short Span,β 1.00 All Positive Moment
Beam Inertia, Ib 8800.00 in4 l2/l1
Long Dir. Slab Inertia, Is 4416.60 in4 α1l2/l1=0
Short Dir. Slab Inertia, Is 4416.60 in4 α1l2/l1>=1
Long α1 1.99
Short α2 1.99
Long , l2/l1 1.00
Short , l2/l1 1.00
Long , α1*l2/l1 1.99
Short , α2*l2/l1 1.99
Average Stiffness, αm 1.99
Thickness of Slab by formula, hmin 4.76 in
Selected Thickness of Slab ,h 6.4 in 160 mm
Live Load on Slab, LL 40 Psf 2 kN/m2
Dead Load on Slab, FF 40 Psf 2 kN/m2
Filling Load, DL 0 Psf 0 kN/m2
Self Weight of Slab 80.00 Psf
Total Factored Load of Slab, Wu 236.00 Psf
Clear covering of Slab 0.8 in 20 mm
Used Rebar dia 0.39 in 10 mm
Max steel ratio, ρmax 0.0193
Effect. depth in Short Direc. ,ds 5.01 in
Effect. depth in Long Direc. ,dl 5.40 in
Ultimate Moment in Long Dire, Mu 130.44 K-ft
Ultimate Moment in Short Dire, Mu 130.44 K-ft
Short direction Moment Caclucation by Percentage.
Beam Moment by Percent 0.85
Column strip Neg. Moment by Percent 0.75
Column strip Post. Moment by Percent 0.75
Short Direction Negative Moment (-Mu) 84.78 K-ft
Short Direction Positive Moment (+Mu) 45.65 K-ft
Short Direction Column Strip Moment Calculation
Int. Negative Moment, (-Mu) 9.54 K-ft
Mid SpanPositive Moment, (+Mu) 5.14 K-ft
Short Direction Middle Strip Moment Calculation
Int. Negative Moment, (-Mu) 21.20 K-ft
Mid SpanPositive Moment, (+Mu) 11.41 K-ft
Long direction Moment Caclucation by Percentage.
Beam Moment by Percent 0.85
Column strip Neg. Moment by Percent 0.75
Column strip Post. Moment by Percent 0.75
Long Direction Negative Moment (-Mu) 84.78 K-ft
Long Direction Positive Moment (+Mu) 45.65 K-ft
Long Direction Column Strip Moment Calculation
Int. Negative Moment, (-Mu) 9.54 K-ft
Mid SpanPositive Moment, (+Mu) 5.14 K-ft
Long Direction Middle Strip Moment Calculation
Int. Negative Moment, (-Mu) 21.20 K-ft
Mid SpanPositive Moment, (+Mu) 11.41 K-ft
Length of Different Strip (Long and Short)
Length of Middle Strip Short Dire. 8.42 ft
Length of Middle Strip Long Dire. 8.42 ft
Length of Column Strip Short Dire. 5.49 ft
Length of Column Strip Long Dire. 5.49 ft
Used Rod Area,as 0.12 in2
Assume the Value of "a" 0.18 in
Short Direction Column Strip Steel Area Calculation in,C/C
2
Int. Negative Moment, (-As) 0.43 in 7.31 182.8 mm
Mid SpanPositive Moment, (+As) 0.23 in2 7.31 182.8 mm
Short Direction Middle Strip Steel Area Calculation in,C/C
Int. Negative Moment, (-As) 0.95 in2 7.31 182.8 mm
Mid SpanPositive Moment, (+As) 0.51 in2 7.31 182.8 mm
Long Direction Column Strip Steel Area Calculation in,C/C
Int. Negative Moment, (-As) 0.40 in2 7.31 182.8 mm
Mid SpanPositive Moment, (+As) 0.21 in2 7.31 182.8 mm
Long Direction Middle Strip Steel Area Calculation in,C/C
Int. Negative Moment, (-As) 0.88 in2 7.31 182.8 mm
Mid SpanPositive Moment, (+As) 0.48 in2 7.31 182.8 mm
Check the Value of "a" 0.18 in
Maximum Spacing of Steel is, S 7.31 in c/c 182.8 mm
Minimum Effective Depth, d 1.72 in OK
Interior Negative Moment
0.5 1 2
75 75 75
90 75 45

All Positive Moment


0.5 1 2
60 60 60
90 75 45
10
12
16