You are on page 1of 1

Test Report 2.2 acc.

to DIN EN 10204
VISUAL INSPECTION [Option code YXX]

LESER GmbH & Co. KG  Postfach 26 16 51  20506 Hamburg, Germany


Customer Order No.: 4509794584
LESER – Job – No.: 20435923
PETROBRAS
LESER-Customers-No.: 180266
LESER-Contact: Thiago Silva
Fon: + 55 (21) 3195-5396
Fax: **
This LESER inspection certificate confirms that the tested components of
the test object was tested according to the under mentioned test references. eMail: silva.thiago@leser.com.br

1. Test object
xxx
xxx
Art.-No. Cold differential test pressure Option Code: xxx
4374.3152 113,80 barg 1.650,53 psig Further SV-Info: xxx

LESER – Pos.- Nominal size Pressure rating


Tag – No. Serial – No. Body material
Job – No. No. Inlet Outlet Inlet Outlet
PSV-1210001 20435923 10 11642957 1.4404/316L NPT 1/2” NPT 1/2” PN250 PN160

Inspected Components
Pos. Description
01 Body Inlet
02 Body Outlet
07 Disc
40 Cap
54 Spring

Note 1: Joints are inspected as an integral part of the Body.

2. Test reference
Visual Inspection acc. to: ASME Code Section V, Article 9
DIN EN 13018
3. Procedure
acc. to: LESER Standard LGS0218

4. Acceptance criteria
acc. to: MSS SP55; BNIF;
ASME Code Section V

5. Test result
The dimensional inspection has been executed in incoming goods inspections, after machining as well as during assembly and final
inspection. The requirements of the test references are fulfilled.

Testing were done by LESER GmbH & Co. KG

Thiago Silva
This certification is written digitally and requires no handwritten signature. (Acc.
Hohenwestedt, + 55 (21) 3195-5396 Inspection Representative
to EN 10204, chapter 5)