7.3.2.1 Objectives
1. Check that the valves are open and that there is a countercurrent flow
configuration.
2. Check that the heating tank is full of water, above the level switch.
5. Fix the hot water flow in about 3 l/min (SC1) and adjust cold water flow
until reaching stationary operating conditions, keeping the temperature set
in the tank constant.
sheet.
7. Repeat steps 5 and 6 for different water temperatures in the tank: 50ºC,
55ºC and 60 ºC.
8. Once the measurements have been taken, calculate the heat transferred
by the hot water, the heat absorbed by the cool water, the heat losses, the
log mean temperature and the overall heat transfer coefficient.
ST-16 (C) 45 50 55 60
ST-1 (C)
ST-2 (C)
ST-3 (C)
ST-4 (C)
ST-5 (C)
ST-6 (C)
ST-7 (C)
SC-1 (l/min) 3 3 3 3
SC-2 (l/min)
Table 3.5.1
PRACTICAL EXERCISES MANUAL
qh ( w )
qc ( w )
ql ( w )
Tlm ( k )
U ( w/m2k )
Table 3.5.2