You are on page 1of 9

Product Selection by Product Type (Cylindrical)

Pre-wired Type Connector Type Pre-wired Connector Type


Specifications
Output Con-
Appear- Shielded/ Detecting Distance
Series
ance Unshielded
Size
(Unit: mm)
Features Power figuration Connector Different Robotics Model Page
Frequency Cable
Supply NPN Type
Type Type
PNP
etc.

M8 - E2E-X2D@-@
Proximity
2
Sensors
Shielded
M12 3 E2E-X3D@-@

M18 • Short type


○ E2E-X7D@-@
DC 2-Wire
7
• Oil resistant -Partially
M30 • Enhanced E2E-X10D@-@ Sensing
10 fastening
NO
○ ○*
strength DC or - -Partially -Partially
Guide
M8 4 • Equipped (2-Wire) NC - E2E-X4MD@-@
Cylindrical
with cable
Unshielded M12 protector E2E-X8MD@-@ Sensors
8
○ Special-purpose
M18 E2E-X14MD@-@
14
-Partially Cylindrical
Sensors
M30 20 E2E-X20MD@-@
Rectangular
M8 1.5 - E2E-X1R5@-@ Sensors
Separate Amp/
Shielded M12 E2E-X2@-@ Pre-wired
2 DC Connector
Type: Models
M18 NPN
○ E2E-X5@-@
5
DC 3-Wire, • Oil resistant
• Equipped
NO -Partially Capacitive
AC 2-Wire DC or PNP Sensors
E2E M30 E2E-X10@-@ 732
10 with cable
protector
(3-Wire) NC NO ○ ○*-
M8 2 • Enhanced
or or -Partially - Partially E2E-X2M@-@ Other
AC NC
fastening AC Type: Sensors
Unshielded strength
M12 5 NO E2E-X5M@-@
or Peripheral
M18 NC ○ E2E-X10M@-@ Devices
10
-Partially
M30 18 E2E-X18M@-@ Other
Information
3 dia. 0.6 E2E-CR6@@
DC 3-Wire
Shielded NPN PNP E2E-CR8@@
4 dia. 0.8 • Small NO NO
- - ○*
DC
M5 1
diameter or
(3-Wire) NC
or
NC
-Partially E2E-X1@@

5.4
1 E2E-C1@@
dia.
DC/AC M12 E2E-X3T1
3
2-Wire Shielded DC
• Ideal for
M18 7 maintenance AC NO - - - - E2E-X7T1
Selectable
M30 10 (2-Wire) E2E-X10T1

M12 4 • Long E2EM-X4X@-@


Shielded distance
M18 8 • Short type E2EM-X8X@-@
DC 2-Wire
• Oil resistant
NO
• Enhanced ○
M30 15 fastening DC or - -Partially - - E2EM-X15X@-@
(2-Wire) NC
strength
Unshielded M18 E2EM-X16MX@-@
16 • Equipped
with cable
E2EM M30 30 protector E2EM-X30MX@-@ 766
• Long
M8 2 E2EM-X2C@-@
distance
DC
DC 3-Wire • Oil resistant
Shielded M12 Type: E2EM-X4C@-@
4 • Equipped
NPN ○
with cable DC NO - -Partially - -
M18 8 protector (3-Wire) E2EM-X8C@-@
or
• Enhanced
NC
fastening
M30 15 E2EM-X15C@-@
strength
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
* Robotics cables are not provided on standard products but can be ordered by adding “-R” to the standard product model numbers.

723
Pre-wired Type Connector Type Pre-wired Connector Type
Specifications
Shielded/ Detecting Distance
Series Appearance Size Features Power Output Model Page
Unshielded (Unit: mm)
Supply Configuration
Long M12 E2EQ-X4X1-@
4
Distance
Shielded • Long distance type
Anti-Spatter • Pre-wired connector type NPN
Proximity M18 8 DC E2EQ-X8X1-@
• Metal case with NO
Fluororesin coating (2-Wire)
Sensors
M30 15 E2EQ-X15X1-@
E2EQ 784
M12 3 E2EQ-X3D1-@
Anti-Spatter
Shielded • Standard type
Sensing • Pre-wired connector type NPN
Guide M18 7 DC E2EQ-X7D1-@
• Metal case with NO
Fluororesin coating (2-Wire)
Cylindrical M30 10 E2EQ-X10D1-@
Sensors
Special-purpose All Stainless M8 1.5 E2FM-X1R5@-@
Cylindrical Steel Metal
Sensors Head Shielded M12 • Full Stainless Steel Body DC E2FM-X2@-@
2 2-Wire
• Enhanced strength and
Rectangular E2FM
wear resistance of sensor or NO 816
Sensors M18 5 surface 3-Wire E2FM-X5@-@
Separate Amp/
Pre-wired M30 E2FM-X10@-@
Connector 10
Models
High-
Capacitive Temperature, M12 3 E2EH-X3D@
• SUS316L Body
Sensors Washable Shielded DC NO or NC
• High temperature: 100°C NPN/PNP
E2EH Type M18 (120°C/1000 hrs) 2-Wire E2EH-X7D@ 774
7 or
or
Other • IP69K 3-Wire DC 2-Wire
Sensors • Detergent resistant
M30 12 E2EH-X12D@

Peripheral DC 3-Wire:
Devices Chemical M12 2 DC E2FQ-X2@
NPN NO
Resistant Shielded 2-Wire
Type or
Other E2FQ M18 5 • Fluororesin case DC 2-Wire E2FQ-X5@ 828
3-Wire and
Information
AC Types:
M30 10 AC NO E2FQ-X10@

Anti- DC 3-Wire:
M12 2 NPN NO E2EZ-X2D@-@
Aluminum DC
Chip Type Shielded • Pre-wired connector type 2-Wire
available or DC 2-Wire:
E2EZ M18 4 • Setting operation NO or NC
E2EZ-X4@-@ 802
3-Wire
indicator (DC 2-Wire)
M30 8 AC Type: E2EZ-X8@-@
AC NO
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.

724
Pre-wired Type
Specifications
Output
Shielded/ Detecting Distance Different
Series Appearance Size Features Power Configuration Connector Robotics Model Page
Unshielded (Unit: mm) Frequency
Supply NPN Type
Type
Cable Type
PNP
etc.
DC
M8 1.5 Type: - E2F-X1R5@
Proximity
NPN
• IEC NO Sensors
Resin Case Shielded M12 2 standard- or E2F-X2@
Type DC
IP68 NC
E2F
compliant
(3-Wire) or - - - 810
M18 5 protective AC AC ○ E2F-X5@
structure Type:
NO Sensing
M30 10 or E2F-X10@ Guide
NC
Cylindrical
Specifications Sensors
Shielded/ Detecting Distance
Series Appearance Size Features Power Model Page Special-purpose
Unshielded (Unit: mm) Output Configuration
Supply Cylindrical
All-metal and Sensors
Long- M12 4 E2V-X4@
• Long-distance Sensor Rectangular
distance
that is shielded
Detection Sensors
• Aluminum chip immunity
DC NPN/PNP
E2V
Pre-wired/ Shielded M18 8 function
NO or NC
E2V-X8@ 834 Separate Amp/
• Operation indicator is (3-Wire) Pre-wired
Pre-wired Connector
visible at any direction
Connector/ Models
Connector M30 15 E2V-X15@
Models Capacitive
For Sensors
M18 • Detects non-ferrous E2EY-X4C1
Aluminum Shielded 4 metals such as aluminum DC 3-Wire:
E2EY Detection and brass DC NPN 798 Other
• Iron and nickel not (3-Wire) NO Sensors
M30 8 E2EY-X8C1
detected
Peripheral
• Able to detect different Devices
M12 2 E2EV-X2C@
kinds of metals
All-metal Shielded • Detecting distance is
DC NPN
E2EV M18 5 three times longer for
NO or NC
E2EV-X5C@ 792 Other
aluminum (3-Wire) Information
M30 • Long distance detection E2EV-X10C@
10 of non-iron metals
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.

725
Product Selection by Product Type (Square)
Specifications
Output
Shielded/ Detecting Distance Different Robotics
Series Appearance Size Features Power Configuration Connector Model Page
Unshielded (Unit: mm) Frequency Cable
Supply NPN Type
Type Type
PNP
etc.
Miniature 5.5 E2S-W1@
Proximity Size, Square, × 19 1.6
× 5.5 E2S-Q1@
Sensors DC 2-Wire

• Miniature
DC - - E2S-W2@
D 8 (2-Wire)
size
L × 20 2.5
Unshielded
• Long
W ×8 E2S-Q2@
distance NO
W×L×D
Sensing E2S • Top and or - - 866
Guide front surface NC
5.5
DC 3-Wire detection
× 19 1.6 E2S-W@@
Cylindrical • Low current
× 5.5 NO
consumption
Sensors D
DC or ○
L 8 (3-Wire) NC
Special-purpose W
Cylindrical × 20 2.5 E2S-Q@@
W×L×D
Sensors ×8

Rectangular NPN PNP


24.9
NO NO
Sensors × 50 5 or or - - TL-W5@@
× 10
Separate Amp/ NC NC
Pre-wired
Connector Shielded
Models 8
× 25 1.5 TL-W1R5MC1
Capacitive × 5.5
• Top surface
Sensors Flat Type 3-Wire:
detection
DC NPN
10 • DC 2-Wire
○*-
Other TL-W D × 27 3 type (3-Wire), NO
or
- TL-W3MC@ 874
Sensors W L ×6 available for Partially Partially
(2-Wire) NC
W×L×D 18
5 mm type
(unshielded)
- ○
Peripheral 2-Wire:
Devices ×
5 NO TL-W5M@
Unshielded
30.5
× 10 or
Other NC
Information 40
× 53 20 - TL-W20ME@
× 23

@25
× 7 TL-N7MD@
38.5 • Long
NO
distance
@30
× 12 detection
DC or - - TL-N12MD@
(2-Wire) NC
52.5 • DC 2-Wire
@40
20 TL-N20MD@
× 53
@25
× DC ○ TL-N5ME@
Unshielded
38.5 (3-Wire) DC
5
TL-N Type: - ○ 882
W L @25
× 50 AC NPN - TL-N5MY@
NO
W×L
DC or
@30 TL-N10ME@
• DC 3-Wire NC
× 10 (3-Wire) - ○
52.5
• AC 2-Wire
AC
-Partially TL-N10MY@
AC
Type:
NO
DC TL-N20ME@
@40 or ○
20 (3-Wire) NC
× 53 -Partially TL-N20MY@
AC
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
* Robotics cables are not provided on standard products but can be ordered by adding “-R” to the standard product model numbers.

726
Product Selection by Product Type (Separate/Relay Type Amplifier)
Sensor Unit Amplifier Unit
Detection Re- Output
Series Appear-
Type Size Range peat- Model Appear- Classifi- Power Configuration Page
ance
(Unit: mm) ability ance cation Supply
NPN PNP
Output Output
3 dia. × E2C-EDR6-F
0.6 1 µm
18 mm *2

Twin Output
Proximity
E2C E2C
Cylindrical
-EDA11 -EDA41
Sensors

Advanced Type
5.4 dia. × E2C-ED01-@ Pre-wired
1 1 µm
18 mm *1*2*3 Type

External Input
8 dia. × 2 µm E2C-ED02-@ Sensing
Shielded 22 mm 2 *1*2*3 E2C E2C Guide
-EDA21 -EDA51
Cylindrical
Screw

E2C- M10 × E2C-EM02-@ Sensors


2 2 µm
EDA 22 mm *1*2*3 DC 912
Special-purpose

Twin Output
Cylindrical
30 × 14 × E2C-EV05-@ E2C E2C Sensors
Flat

5 2 µm -EDA6 -EDA8
4.8 mm *1*2*3

Advanced Type
Connector Rectangular
Type Sensors
Screw

M18 × E2C-EM07M-@ Separate Amp/


Unshielded 7 5 µm
46.3 mm *1*2*3

External Input
Pre-wired
Connector
E2C E2C Models
-EDA7 -EDA9
Screw

M12 × E2C-EM02H Capacitive


Heat-resistant 2 2 µm
22 mm *2 Sensors

*1 A protective spiral tube is supplied. This is indicated by “-S” at the end of the model number. (Example: E2C-ED01-S)
Other
*2 Two types of cable length are available. (3 dia. is a free-cut cable. Heat-resistant type comes only with the standard cable length.) Sensors
Total length of standard length type: 2.5m / Distance between head and preamplifier: 2m (Example: E2C-ED01)
Total length of free-cut type: 3.5m / Distance between head and preamplifier: 0.5m. This is indicated by “-F” at the end of the model number. (Example: E2C-ED01-F) Peripheral
*3 Models with protective spiral tube (indicated by “-S”) and free-cut cable type (indicated by “-F”) are available on a custom-made basis. Devices

Other
Information

727
Product Selection by Product Type (Separate/Relay Type Amplifier)
Pre-wired Type
Sensor Unit Amplifier Unit
Series Appear- Shielded/ Stable Detection Maximum Model Power Page
Size Model Features
ance Unshielded Range (Unit: mm) Operating Distance Supply
3.5 E2C-CR8A E2C-GE4B
dia.
Proximity 0.8 1.8
3.8 E2C-CR8B E2C-GF4B
Sensors dia. Miniature
Size
E2C-GE4A
M5 E2C-X1A
1 2 E2C-GF4A
Shielded 5.4 E2C-C1A
Sensing dia.
E2C-WH4A DC
Guide M8 E2C-X1R5A Slim DIN Rail
E2C 1.5 3
Mount
E2C-WH4AF 928
Cylindrical
M12 2 5 E2C-X2A
Sensors
E2C-JC4AP Slim Off-
Special-purpose M18 5 10 E2C-X5A Delay Timer
Cylindrical E2C-JC4A Feature
Sensors
M30 10 18 E2C-X10A Adjustable
E2C-AM4A
Rectangular Hysteresis
Sensors Unshielded 40 dia. 20 50 E2C-C20MA Adjustable
Hysteresis
Separate Amp/ E2C-AK4A AC
Pre-wired Solid-state
Connector Relay Output
Models
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Capacitive
Sensors
Pre-wired Type
Other Specifications
Sensors Output Con-
Shielded/ Detecting Distance Different
Series Appearance Size Features Power figuration Connector Robotics Model Page
Unshielded (Unit: mm) Frequency
Peripheral Supply NPN, Type Cable Type
PNP Type
Devices etc

Other E2EC-MC2D1
Information Amplifier
• Stainless DC
Relay Type Shielded
Steel Head 2-Wire
E2EC-M
E2EC-Q 8 dia. 2 • Robotic Cable or NO NO ○ - ○ E2EC-MC2B1 906
• Fluororesin 3-Wire
Coating(-Q)
E2EC-QC2D1
-M1GJ-T

3 dia. 0.8 E2EC-CR8D@


Amplifier
Relay Type Shielded 5.4 E2EC-C1R5D@
dia.
1.5 • Equipped with
NO
E2EC
robotic cable
DC or - - ○ ○ 898
8 dia. 3 (2-Wire) NC E2EC-C3D@

M12 4 E2EC-X4D@

728
Specifications
Shielded/ Detecting Distance
Series Appearance Size Features Power Output Model Page
Unshielded (Unit: mm)
Supply Configuration
Separate E2CY-X1R5A
Amplifier for M5
+ E2CY-T11
Aluminum 1.5
Detection 5.4 • Detects non-ferrous metals E2CY-X1R5A-1
Shielded dia. such as aluminum and DC 3-Wire: + E2CY-T11
D copper NPN Proximity
E2CY DC E2CY-C2A(F) 950
W
8 dia. 2 • Comes with teaching and (3-Wire) NO/NC Sensors
L sensitivity margin displays (Selectable) + E2CY-T11

12 ×
E2CY-V3A
25 × 3 + E2CY-T11
4.5
W×L×D Sensing
Heat- E2C-X1R5AH Guide
M8 1.5
Resistant + E2C-JC4CH
Type Shielded E2C-X2AH Cylindrical
M12 2 NPN
• Applicable at 200°C DC + E2C-JC4DH Sensors
E2C-H NO/NC 928
• Compact Type (3-Wire) (Selectable)
E2C-X5AH Special-purpose
M18 5 Cylindrical
+ E2C-JC4EH
Sensors
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using. Rectangular
Sensors
Separate Amp/
Pre-wired
Connector
Models

Capacitive
Sensors

Other
Sensors

Peripheral
Devices

Other
Information

729
Product Selection by Product Type (Capacitive Type)
Pre-wired Type
Specifications
Output
Shielded/ Detecting Distance
Series Appearance
Unshielded
Size
(Unit: mm)
Features Power Configuration Connector Different Robotics Model Page
Frequency
Supply NPN, Type
Type
Cable Type
PNP
etc
Proximity DC
Sensors DC
Type:
(3-Wire) NPN
Long E2K-C25M@
Distance 3 to 25 or NO
Type Unshielded AC or
• Adjustable NC
E2K-C 34
dia. Sensitivity - - - - 956
Sensing DC AC
Guide (3-Wire) Type:
NO E2K-C20M@
3 to 20 AC/DC
Cylindrical selectable or
Sensors NC
(2-Wire)
Special-purpose DC
Cylindrical M12 4 Type: E2K-X4M@
Sensors NPN
General- NO
Rectangular purpose Type Unshielded DC or
Sensors (3-Wire) NC
Separate Amp/
E2K-X M18 8 - or
- - - - E2K-X8M@ 964
Pre-wired AC
Connector AC Type:
Models NO
M30 15 or E2K-X15M@
Capacitive NC
Sensors

Other
Flat Type 10 E2K-F10MC@
Sensors Unshielded 50 × NPN
• Thickness: NO
Peripheral E2K-F
W D
20 ×
10mm
DC
or - - - - 970
L 10.1 (3-Wire)
Devices NC
W×L×D 4 to 10 E2K-F10MC@-A
Other
Information Flat,
Separate 20 × E2J-W10MA
Amplifier 30 × 4 to 10 • Must be NPN +
Type Unshielded 5.5 used NO E2J-JC4A
together with DC or
E2J
W
D
E2J-JC4A NC - ○ - ○ 982
(3-Wire)
L
30 × Amplifier (Select- E2J-W20MA
40 × Unit able) +
5.5 8 to 20 E2J-JC4A
W×L×D
Chemical • Fluororesin
Resistant Case
Unshielded • Adjustable
Type
NPN
E2KQ-X M18 6 to 10 Sensitivity DC
NO - - - - E2KQ-X10ME1 978
Type (3-Wire)
(Except for
Cable)
Note:The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.

Bypass Pipe Mount Type


Applicable Specifications
Appear-
Series Pipe Features Power Output Model Page
ance
Diameter Supply Configuration

8 to 11 dia. • Supports a wide range of pipe E2K-L13MC1


NPN
E2K-L diameters DC
NO
974
• Built-in amplifier, space-saving (2-Wire)
12 to 26 dia. E2K-L26MC1

Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.

730
Product Selection by Product Type (Other Proximity Sensors)
Specifications
Detecting Distance
Series Appearance Power Output Model Page
(Unit: mm)
Supply Configuration

DC NO or NC TL-M2ME@
(3-Wire)
Micro Switch Type 2
AC NO TL-M2MY1 Proximity
(2-Wire) Sensors
TL-M 894
DC NO or NC TL-M5ME@
(3-Wire)
5
AC NO TL-M5MY1
(2-Wire) Sensing
Guide
Cylindrical Type
Cylindrical
Current Output Sensors
TL-L 100 DC
Type NO
TL-L100-7 Web
(3-Wire)
Special-purpose
Cylindrical
Sensors
Series Type Model Page Rectangular
Sensors
Set GLS-1
Separate Amp/
GLS Switch Unit GLS-S1 988 Pre-wired
Connector
Models
Magnet Unit GLS-M1
Capacitive
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using. Sensors

Other
Sensors

Peripheral
Devices

Other
Information

731

You might also like