You are on page 1of 10

ODIN Meter

An electricity energy meter from ABB

Technical documentation
ODIN Meter

Contents
General description .............................................................................................................. 2
OD4165 direct connection, 3 phase meter up to and including 65 A ............................... 3
OD4110 transformer connection, 3 phase meter ............................................................... 4
Accessories .......................................................................................................................... 5
Wiring diagrams ................................................................................................................... 6
Device dimensions ................................................................................................................ 7
Examples of connections ...................................................................................................... 8

ABB 1
ODIN Meter
General Description

ODIN Meter is a compact electricity energy meter made for measuring active
electrical energy and designed to be mounted on a DIN rail in distribution boards
or in standard cabinets.

During the development process creating SIMPLICITY was the number one priority.
The ODIN Meter shall be perceived as easy to install, use and distribute.
St375010

Examples of this can already be seen on the front of the electricity energy meter,
clear marking, strong screws in the connecting terminal and an easy to read display.
Enclosed in the carton are easy to understand instructions, which use text and
diagrams to describe in detail how the installation should be carried out.

The ODIN Meter is certified according to the international standard IEC 61036. The
standard covers several technical requirements including climate, mechanics,
electronics, EMC and accuracy. Furthermore the ODIN Meter has a national
approval from Sweden’s Test and Research Institute (SP) as a revenue meter. This
guarantees the ODIN Meter is highly reliable, has a long life expectancy and
maintains its measuring accuracy.

2 ABB
ODIN Meter
OD4165 direct connection, 3 phase meter up to
and including 65 A

Article number Type Voltage (V) Pulse output frequency

2CMA131024R1000 OD4165 230/400V 100 imp./kWh

Technical Data
St375010

Voltage:
3x230/400 V AC
Voltage range -20% to +15%
Max current 65 A
Start current 25 mA
Power consumption of current circuits < 3 VA/phase
Frequency 50/60 Hz
Accuracy of measurement Class 2 (±2%)
Standard IEC 61036
Temperature range -25 to +55oC
Material of front cover Polycarbonate
Material of back cover Polycarbonate/glass fibre
Resistance to heat and fire Equivalent to IEC 695-2-1
Protection against penetration of dust and water IP 20
Connection area in the current connecting terminals 1 – 16 mm2

Pulse output

Connection area in the connecting terminal 0.5 – 2.5 mm2


External pulse voltage 5 – 40 V DC
Max. current 100 mA
Pulse length 100 ms ±2.5 ms
Pulse frequency 100 imp/kWh
Standard IEC 62053-1 (S0)

LED

Pulse frequency 100 imp/kWh


Pulse length 40 ms

Display LCD with 7 digits without a


decimal place, 6 mm

Front view

Direct connection

Type description Wiring diagram

OD4165

LED
frequency
St375004

Drestromzahler 5(65)A Kl.2


Electricity meter 5(65)A Cl.2

Phase indicator Identification No. National approval Pulse output


Load indicator symbol (SP) frequency

ABB 3
ODIN Meter
OD4110 connection via external current transformers,
3 phase meter

Article number Type Voltage (V) Pulse output frequency

2CMA131025R1000 OD4110 230/400V 1 imp./kWh

Technical Data
St375010

Voltage: 3x230/400 V AC
Voltage range -20% to +15%
Max. current 10 A
Starting current 15 mA
Power consumption of current circuits < 0.02 VA/phase
Power consumption of voltage circuits < 2 VA/phase
Frequency 50/60 Hz
Accuracy of measurement Class 2 (±2 %)
Standard IEC 61036
Temperature range -25 to +55oC
Programmable transformer ratios 5/5, 75/5, 100/5
150/5, 200/5, 250/5, 300/5,
400/5, 500/5, 600/5, 700/5
750/5, 800/5, 900/5 A/A
Material of front cover Polycarbonate
Material of back cover Polycarbonate/glass fibre
Resistance to heat and fire Equivalent to IEC 695-2-1
Protection against penetration of dust and water IP 20
Connection area in the current connection terminal 1 – 16 mm2
Connection area in the voltage connection terminal 0.5 – 6 mm2

Pulse output

Connection area in the connection terminal 0.5 – 2.5 mm2


External pulse voltage 5 – 40 V DC
Max. current 100 mA
Pulse length 100 ms ±2.5 ms
Pulse frequency 1 imp/kWh
Standard IEC 62053-1 (S0)

LED

Pulse frequency 1000 imp/kWh


Pulse length 40 ms

Display LCD with 7 digits whitout a


decimal place, 6 mm

Front view

Connection via current transformer

Type description Adjustable transformer ratio Wiring diagram

LED
frequency
St375005

Phase indicator Identification No. National approval Pulse output


Load indicator symbol (SP) frequency

4 ABB
ODIN Meter
Accessories

Article number Type Use Picture No.

09 809 25 Protective sealable flap When sealing

09 811 84 Front mounting kit For panel mounting 2


St375002

09 809 50 Enclosure (6 modules) For wall mounting 3

Picture No. 2

45,5
80
St375003

106
161

Mt375003

Picture No. 3

160 92
St375001

180

175

Mt375001

ABB 5
ODIN Meter
Wiring diagrams

Wiring diagrams

Direct connection Connection via current transformer

P1 P1 P2
L1
S1 S2
P1
L2
P1
L3
N
St375006

PE

2 5 8 11 1 4 7

St375007
+ -
20 21 11 3 6 9

Pulse output
St375008

St375009

6 ABB
ODIN Meter
Device dimensions

Device dimensions

4,7
6.6 5.7
7.1

57.4

8.75 17.5 44
O 5.3 O 7.4
85

45
O 4.4 24.8 20 63,4

105

Mt375002

ABB 7
ODIN Meter
Examples of connections

Connections with cables

The electricity meter will


function correctly with the
neutral connected to either the
upper or lower terminal

Connections with cables and busbar

8 ABB
Österbergs & Sörmlandstryck, 23410
29551 Eng Oct 01 ODIN Meter

ABB Automation Technology Products AB


Cewe
Box 1005
S-611 29 Nyköping, Sweden
Phone Int +46 155-29 50 00
Fax Int +46 155-28 81 10

You might also like