Professional Documents
Culture Documents
SIDE REINFORCEMENT
FOR ALL BEAMS DEEPER THAN 750
(OVERALL) U.N.O IN BEAM SCHEDULES
WIDTH OF BEAM SIDE REFT
200 T12-250
PMO
300 T12-200
GRID GRID GRID GREATER THAN 400 T12-150 8 LEGGED 12 LEGGED
COLUMN CORE EXTEND TENSION DEVELOPMENT LENGTH (Ld)
OR TENSION HOOKED DEVELOPMENT LENGTH (Ldh)
WHERE HOOKED INTO COLUMN CORE.
0.25 Ln1 0.3 Ln1 OR 0.3 Ln2 0.3 Ln1 OR 0.3 Ln2 0.3 Ln2 OR 1.25 Lnc 0.5 Lnc OR 50 dia
GREATER GREATER GREATER GREATER
LAP (TYP.) 0.25 Ln1 OR Ln2 LEAD ARCHITECT / PLANNER
0.25 Ln1 OR Ln2 0.25 Ln1 OR Ln2
GREATER
A2 A1 D GREATER C1 D C2 C1 TOP BARS
C2
S1 S2 S1 S1 S2 S1 S1 S2
6 LEGGED 4 LEGGED 2 LEGGED LEAD CONSULTANT
STIRRUPS
B1 (IN B2LAYER)
SIDE BARS STIRRUPS
D
0.10 Ln
B1 B2
0.125 Ln NOTE:
SIDE BARS SPACERS GREATER OF E1 (IN B2 LAYER) SPACERS GREATER OF SIDE BARS B1 B2 E1 (IN B2LAYER) SIDE BARS B1
25mmØ OR MAIN BARØ 25mmØ OR MAIN BAR∅ SPACER BAR 1. FOR TENSION SPLICE AND STANDARD HOOK REFER GENERAL NOTES.
MAIN BARS FROM BEAM IN MAIN BARS FROM BEAM IN
52,33 TYP. FIRST STIRRUPS (TYP) 2. REINFORCING BARS SHALL BE KEPT IN ONE LAYER WHERE POSSIBLE, DIFFERENT
TRANSVERSE DIRECTION (TYP.) TRANSVERSE DIRECTION (TYP.)
Ln1 Ln2 Lnc LAYERS ARE SHOWN FOR CLARITY.
BOTTOM BARS 3. STIRRUPS ARE NOT SHOWN FOR CLARITY.
(CANTILEVER SPAN) ARCHITECT CONSULTANT
4. CRANKING OF BARS SHALL BE DONE AT LAP LOCATIONS IN BEAMS TO PROVIDE
L1 L2 Lc ADEQUATE CLEAR SPACE BETWEEN BARS.
W
(CANTILEVER SPAN) 5. C1, C2 & E1 BARS TO BE THE LARGER DIAMETER FROM SPANS L1 AND L2.
SPAN L3 CL SPAN L4
CL C CL C CL C C
0.25L3 OR 1.25L4 OR 45 BAR DIA FACE OF 0.5L4 OR 45 BAR DIA
WHICHEVER IS GREATER SUPPORT WHICHEVER IS GREATER MIN 0.25L1 MIN 0.25L1 MIN 0.25L1
Ta MIN 0.3L1
PROVIDE LARGE
LAP LAP LAP LAP
RADIUS BEND (TYP.)
0.75 (L4) OR 0.15L2 OR 45 BAR DIA CJ
WHICHEVER IS GREATER
Ta
C -T2 Ta
D
D
WALL/
Ta COLUMN
C -T1
COLUMN/WALL LAP LAP Rev:
25 LAP COLUMN/WALL 25 LAP 25 LAP
COLUMN/WALL 25
A A A
A
50 END STIRRUPS SPAN STIRRUPS
TYPE-1 : Ta : MEANS THE LENGTH TYPE-2 : Ta : MEANS THE LENGTH TYPE-3 : Ta : MEANS THE LENGTH TYPE-4 : Ta : MEANS THE LENGTH
OF A NORMAL LAP LENGTH OF A NORMAL LAP LENGTH OF A NORMAL LAP LENGTH OF A NORMAL LAP LENGTH
(EDGE COLUMN) (EDGE COLUMN) (Ta CANNOT BE ACHIEVED WITHIN BEAM DEPTH) (LONG COLUMNS /WALLS)
B -B1 (EDGE COLUMN)
Seal/Signature
2nd LAYER OF MAIN BEAM REFT. 2nd LAYER OF MAIN BEAM REFT.
3 bd
h
Project Number
420
MIN.
OPTION-1 : FULL CONTINUITY OF BOTTOM REFT. OPTION-2 : SPLICE / LOOSE METHOD Scale
1 : 25 A1