Maintenance

What this Chapter Contains


This chapter contains preventive maintenance instructions.

Safety

WARNING! Read the "Safety Instructions" on the first pages of this manual before
performing any maintenance on the equipment. Ignoring the safety instructions can
cause injury or death.

Maintenance Intervals
If installed in an appropriate environment, the drive requires very little maintenance.
This table lists the routine maintenance intervals recommended by ABB.
Interval Maintenance For instruction, see section

Every 3 months UL Type 12 Checking and Replacing the Air Filters (min)
Cleanliness check Heatsink
Every year when Capacitor reforming Reforming
stored
Every 6 years UL Type 12 and all -0490-5 through -0610-5 Replacing the Cabinet Fan
Every 6 years Drive module cooling fan change (frame size R7) Replacing the Drive Module Fan (R7)
Every 6 years Drive module cooling fan change (frame size R8) Replacing the Drive Module Fan (R8)
Every 10 years Capacitor change Capacitors

Air FIlter Material


Enclosure Type Inlet (door) Outlet (roof)
UL Type 12 3AUA0000006723 (qty 1) 3AUA0000006722 (qty 2)

Note: When installing the filter media, the white side must face the outside of the cabinet and the
colored side must face the inside of the cabinet.