You are on page 1of 6

Any Company • Any Street 21 • 54321 Any Town

Any Company
Any Street 21
54321 Any Town

Tel.: +49 123 456-0


Fax: +49 123 456-100
E-Mail: info@any-company.de
Internet: www.any-company.de

Project: contoh Location: Indonesia / Palu


Project number: ---
Grid voltage: 230V (230V / 400V)

System overview

5 x .SMA SMA Demo Poly 240 (PV array 1)


Azimuth angle: 180 °, Tilt angle: 5 °, Mounting type: Roof, Peak power: 1.20 kWp

1 x SB 1.5-1VL-40

System Monitoring

Meter Connection Box Sunny Home Manager 2.0

Sunny Portal SMA Com Gateway

PV design data

Total number of PV modules: 5 Performance ratio*: 82.1 %


Peak power: 1.20 kWp Spec. energy yield*: 1363 kWh/kWp
Number of PV inverters: 1 Line losses (in % of PV energy): ---
Nominal AC power of the PV inverters: 1.50 kW Unbalanced load: 1.50 kVA
AC active power: 1.50 kW Annual energy consumption: 1,800 kWh
Active power ratio: 125 % Self-consumption: 423.40 kWh
Annual energy yield*: 1,635.23 kWh Self-consumption quota: 25.9 %
Energy usability factor: 100 % Self-sufficiency quota: 23.5 %

Signature

*Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no
responsibility for the real yield value which can deviate from the yield values displayed here. Reasons for deviations are various external
conditions, such as soiling of the PV modules or fluctuations in the efficiency of the PV modules.

1/6 Version: 4.0.4.R / 12/29/2018


Inverter designs
Project: contoh Location: Indonesia / Palu
Project number: Ambient temperature:
Annual extreme low temperature: 20 °C
Average high Temperature: 31 °C
Subproject Subproject 1 Annual extreme high temperature: 36 °C

1 x SB 1.5-1VL-40 (PV system section 1)

Peak power: 1.20 kWp


Total number of PV modules: 5
Number of PV inverters: 1
Max. DC power (cos φ = 1): 1.60 kW
Max. AC active power (cos φ = 1): 1.50 kW
Grid voltage: 230V (230V / 400V)
Nominal power ratio: 133 %
Dimensioning factor: 80 % SB 1.5-1VL-40
Displacement power factor cos φ: 1

PV design data

Input A: PV array 1
5 x .SMA SMA Demo Poly 240, Azimuth angle: 180 °, Tilt angle: 5 °, Mounting type: Roof

Input A:
Number of strings: 1
PV modules: 5
Peak power (input): 1.20 kWp

Typical PV voltage: 131 V


Min. PV voltage: 125 V
Min. DC voltage (Grid voltage 230 V): 50 V

Max. PV voltage: 188 V


Max. DC voltage: 600 V

Max. MPP current of PV array: 8.1 A


Max. operating input current per MPPT: 10 A
Max. input short-circuit current per MPPT: 18 A
Photovoltaic Output Circuit Current: 8.5 A

PV/Inverter compatible

2/6 Version: 4.0.4.R / 12/29/2018


Wire sizing
Project name: contoh Location: Indonesia / Palu
Project number:

Overview

DC LV Total

Power loss at nominal 7.11 W 6.11 W 13.22 W


operation

Rel. power loss at rated 0.58 % 0.51 % 1.09 %


nominal operation

Total cable length 20.00 m 10.00 m 30.00 m

Cable cross-sections 4 mm² 1,5 mm² 4 mm²


1,5 mm²

Graphic

DC cables

Cable material Single length Cross section Voltage drop Rel. power loss

Subproject 1

1 x SB 1.5-1VL-40 A Copper 10.00 m 4 mm² 782 mV 0.58 %


PV system section 1

Lines LV1

Cable material Single length Cross section Line resistance Rel. power loss

Subproject 1

1 x SB 1.5-1VL-40 Copper 10.00 m 1,5 mm² R: 229.333 mΩ 0.51 %


PV system section 1 XL: 1.500 mΩ

The displayed results are approximate values to give a general indication to users of possible operating results. The results are determined
mathematically. The actual operating results will be dictated significantly by the actual climatic conditions, the actual efficiency, the system
components' operating conditions and the individual consumption behavior and can deviate from the calculated results. SMA Solar
Technology AG therefore assumes no liability in the event of deviations between the calculated and actual operating results.

3/6 Version: 4.0.4.R / 12/29/2018


Design energy management
Project name: contoh Location: Indonesia / Palu
Project number:

PV system System Monitoring

Subproject 1 Within the PV system External


1 x SB 1.5-1VL-40 SMA Com Gateway Sunny Portal
PV system section 1 Communication gateway to Internet portal for monitoring PV
integrate RS485-wired existing systems and for the visualization
plants into control and monitoring and presentation of PV system data
solutions with SMA Speedwire.

Meter Connection Box


Capture of energy meter counting
pulses

Sunny Home Manager 2.0


The control center with integrated
measuring system for smart energy
management

Information

Meter Connection Box This device is no longer available.

Sunny Home Manager 2.0 For the implementation of the storage management and the limitation of the active power
feed-in, the internal measuring system of the Sunny Home Manager 2.0 for measuring the
grid feed-in and purchased electricity, must have been connected and configured (see
planning guidelines "SMA Smart Home").

General The maximum communication range for Bluetooth® Wireless Technology in free-field
conditions and for Speedwire (SMA Ethernet) is 100 m.

4/6 Version: 4.0.4.R / 12/29/2018


Self-consumption (electricity)
Project: contoh Location: Indonesia / Palu
Project number:

Information on self-consumption

Load profile: 1 adult, in full-time employment


Private household with one person in full-time employment and often out in the evenings.

Annual energy consumption: 1800 kWh

Increased self-consumption

Sunny Home Manager 2.0


The control center with integrated measuring system for smart energy management

Result

Without increased self-consumption

The displayed results are estimated values which are derived mathematically. SMA Solar Technology AG accepts no liability for the actual
self-consumption which may deviate from the values displayed here. The potential self-consumption essentially depends on individual load
patterns, which may deviate from the load profile on which the calculation is based.

5/6 Version: 4.0.4.R / 12/29/2018


Monthly values
Project name: contoh Location: Indonesia / Palu
Project number:

Diagram

Table

Month Energy yield [kWh] Self-consumption [kWh] Grid feed-in [kWh] Purchased electricity
[kWh]

1 121 (7.4 %) 37 83 124

2 115 (7.0 %) 33 81 111

3 146 (8.9 %) 38 108 130

4 143 (8.7 %) 37 106 116

5 148 (9.0 %) 37 111 117

6 140 (8.5 %) 34 105 111

7 151 (9.2 %) 21 130 65

8 143 (8.8 %) 29 114 114

9 141 (8.6 %) 35 107 114

10 140 (8.5 %) 41 98 122

11 129 (7.9 %) 39 90 120

12 120 (7.3 %) 41 79 132

6/6 Version: 4.0.4.R / 12/29/2018