You are on page 1of 4

1. bItem No.

*****
Reinforced cement concrete works (f’c= 25 Mpa, f’cr= 30MPa) using Batching Plant (on
site)

Batching Plant Reinforced cement concrete works using steel shutter having f’cr= 30 MPa and
satisfying a specified strength f’c= 25 Mpa at 28 days on standard cylinders by using minimum
389 kg of cement per cum of concrete as per standard practice of Code ACI/BNBC/ASTM & Cement
conforming to BDS EN-197-1-CEM1, 52.5N (52.5 MPa)/ASTM-C 150 Type-I and adding approved
high range water reducing admixture of complying specific type (generally be Type-G) under
ASTM-C 494, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well
graded stone chips conforming to ASTM C-33 including breaking chips and screening through proper
sieves, making and placing shutter in position and maintaining true to plumb, making shutter water
tight properly, placing reinforcement in position.

Providng and laying in position concrete manufactured in fully automatic batching plant and
transported to site of work, manufactured as per mix design of specified grade for reinforced cement
concrete works including pumping of concrete to site of laying, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time approved; including
cost of water, electricity, additional testing charges of materials and cylinders required by engineer,
other charges etc. all complete approved and accepted by the Engineer. (Rate is excluding the cost of
reinforcement and its fabrication, placing and binding)
2. Item No. *****
Reinforced cement concrete works (f’c= 32Mpa, f’cr= 40MPa) using Batching Plant (on site)

Batching Plant Reinforced cement concrete works using steel shutter having f’cr= 40MPa and
satisfying a specified strength f’c= 32Mpaat 28 days on standard cylinders by using minimum 446
kg of cement per cum of concrete as per standard practice of Code ACI/BNBC/ASTM & Cement
conforming to BDS EN-197-1-CEM1, 52.5N (52.5 MPa)/ASTM-C 150 Type-I and adding approved
high range water reducing admixture of complying specific type (generally be Type-G) under
ASTM-C 494 , best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well
graded stone chips conforming to ASTM C-33 including breaking chips and screening through proper
sieves, making and placing shutter in position and maintaining true to plumb, making shutter water
tight properly, placing reinforcement in position.

Providng and laying in position concrete manufactured in fully automatic batching plant and
transported to site of work, manufactured as per mix design of specified grade for reinforced cement
concrete works including pumping of concrete to site of laying, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time approved; including
cost of water, electricity, additional testing charges of materials and cylinders required by engineer,
other charges etc. all complete approved and accepted by the Engineer. (Rate is excluding the cost of
reinforcement and its fabrication, placing and binding)
Specification of Concrete Works

1) Specification of Concrete Works ( 25MPa):

 Material Specification:
o Cement : BDS EN-197-1- CEM1, 52.5N(52.5 MPa)ASTM- C150 Type-I
o Fine Aggregate : Best quality Sylhet sand or coarse sand of equivalent F.M=2.2
o Coarse Aggregate: 20 mm down well graded stone chips
o Admixture: Type G (Water reducer / super plasticizer)

 Concrete Specification:
o Specified Compressive Strength, fc’= 25MPa
Crushing Strength, fcr’= 30MPa.(at 28 days on standard cylinder)
o Minimum Cement Content= 389 kg per cum of concrete
o Pouring Method : Pumping

2) Specification of Concrete Works( 32MPa):

 Material Specification:
o Cement : BDS EN-197-1- CEM1, 52.5N(52.5 MPa)ASTM- C150 Type-I
o Fine Aggregate : Best quality Sylhet sand or coarse sand of equivalent F.M=2.2
o Coarse Aggregate: 20 mm down well graded stone chips
o Admixture: Type G (Water reducer / super plasticizer)

 Concrete Specification:
o Specified Compressive Strength, fc’ = 32 MPa
Crushing Strength, fcr’= 40MPa.(at 28 days on standard cylinder)
o Minimum Cement Content= 446 kg per cum of concrete
o Pouring Method : Pumping