You are on page 1of 2

Transfer Pump

Description To prevent overpressure conditions, non- Applications


The transfer pump (PMP) is designed to pump centrifugal PMP models are fitted with a
pressure relief bypass valve. The centrifugal
■ Well testing surge tanks or gauge
oil from a tank to a burner or from a tank into tank transfer
an existing flowline. Normally fitted with an models are self protected. PMPs are shock-
explosion-proof electrical motor for opera- protected by a frame, and some are rated to ■ Reinjection of separator oil into
tions in Zone 2 regions, the PMP can also be Det Norske Veritas (DNV) 2.7-1 standard. an existing flowline
fitted with a diesel engine for remote location All PMPs are manufactured under Type ■ Pump liquids to a tanker
operations. Approval or Design Verification Review and
Gear, screw, and centrifugal pump designs are provided with a Certificate of Conformity Benefits
are available. The characteristics of the fluid and a full quality file.
■ Provides a means to empty one
being pumped and the specific application tank compartment while filling
for the pump determine which pump tech- another
nology is most suitable.
■ Increases pressure for burner
operation
Transfer pump.
Features
■ Can be used in remote locations
when fitted with a diesel engine,
or in Zone 2 regions when fitted
with an electrical motor
■ Protected against overpressure
by a relief bypass (except cen-
trifugal designs, which are self
protected)
■ Explosion-proof electrical motors
■ Shock-protected by a frame
■ Compliant with ASME† B31.3;
electrical motor compliant with
EExd‡ IIB T4

† American Society of Mechanical Engineers


‡ Induction motors certified for explosive areas
Transfer Pump Specifications
Model Motor Pump Pumping Service Pump Maximum Working CE† Part
Type Type Application Capacity, Working Temperature, Marking Number
m3/d [bbl/d] Pressure, degC [degF]
at Pressure, kPa [psi]
kPa [psi]
PMP-EA Electrical Screw Tank transfer Standard 636 [4,000] 2,069 [300] –20 to 100 Yes 100079604
at 2,069 [300] [–4 to 212]
PMP-ECB Electrical Gear Tank transfer Standard 317 [2,000] 1,379 [200] 0 to 100 No M816551
at 1,379 [200] [32 to 212]
PMP-EDB Electrical Centrifugal Diesel for Standard 254 [1,600] 3,793 [550] –20 to 100 No M809932
mud burner at 3,793 [550] [–4 to 212]
PMP-EDC Electrical Screw Tank transfer Standard 636 [4,000] 2,069 [300] 0 to 100 No M835701
at 2,069 [300] [32 to 212]
PMP-EFE Electrical Centrifugal Tank transfer H2S 1,590 [10,000] 4,965 [720] –29 to 100 No M816514
at 2,620 [380] [–20 to 212]
PMP-GE Electrical Centrifugal Tank transfer H2S 795 [5,000] 4,965 [720] –20 to 100 No P485910
at 2,069 [300] [–4 to 212]
PMP-HA Electrical Gear Tank transfer Standard 1,081 [6,800] 1,724 [250] 0 to 100 Yes 100157683
at 1,724 [250] [32 to 212]
PMP-TCB Diesel Gear Tank transfer Standard 317 [2,000] 1,379 [200] 0 to 100 No M837654
at 1,379 [200] [32 to 212]
PMP-TDC Diesel Screw Tank transfer Standard 636 [4,000] 2,069 [300] 0 to 100 No M837657
at 2,068 [300] [32 to 212]
PMP-TDW Diesel Screw Tank transfer Standard 636 [4,000] 2,069 [300] 0 to 100 No 100097403
at 2,069 [300] [32 to 212]
† Conformité Européenne

Transfer Pump Specifications and Codes


Model Connections Fluid Supply Supply Dimensions, Weight, Applied Codes
Pumped Voltage, V Power, kW (L × W × H), m [ft] kg [lbm]
Inlet Outlet
PMP-EA 3-in 3-in Oil 460, 60 Hz 33 3.40 × 0.85 × 1.42 1,500 [3,307] PED† 97/23/EC, ASME B31.3,
Fig 602 Fig 602 400, 50 Hz [11.16 × 2.79 × 4.66] ATEX‡ 94/9/EC,
Female Male CE Marked
PMP-ECB 3-in 3-in Oil 440, 60 Hz 11 1.30 × 0.68 × 0.86 430 [950] Explosion-proof
Fig 602 Fig 602 380, 50 Hz [4.27 × 2.23 × 2.82] EExd IIB T4, IP55-7
Female Male
PMP-EDB 3-in 3-in Diesel oil 460, 60 Hz 33 2.20 × 1.10 × 1.47 1,000 [2,200] Explosion-proof
Fig 602 Fig 602 400, 50 Hz [7.22 × 3.61 × 4.82] EExd IIB T4, IP55-7
Female Male
PMP-EDC 3-in 3-in Oil 440, 60 Hz 35 3.35 × 0.85 × 1.42 1,500 [3,307] Explosion-proof
Fig 602 Fig 602 380, 50 Hz [11 × 2.79 × 4.66] EExd IIB T4, IP55-7
Female Male
PMP-EFE 3-in 3-in Oil 440, 60 Hz 130 2.05 × 1.47 × 2.34 2,954 [6,512] Explosion-proof
Fig 602 Fig 602 380, 50 Hz [6.73 × 4.83 × 7.68] EExd IIB T4, H2S
Female Male (NACE MR0175)
PMP-GE 4-in 3-in Oil 440, 60 Hz 75 2.70 × 1.29 × 2.80 3,500 [7,716] Explosion-proof
Fig 602 Fig 602 380, 50 Hz [8.86 × 4.23 × 9.19] EExd IIB T4, IP55-7, H2S
Female Male (NACE§ MR0175), DNV 2.7-1
PMP-HA 4-in 3-in Oil and 460, 60 Hz 55 2.65 × 1.50 × 1.50 2,700 [5,953] Explosion-proof
Fig 602 Fig 602 water 400, 50 Hz [8.70 × 4.93 × 4.92] EExd IIB T4, IP55-7,
Female Male DNV 2.7-1
PMP-TCB 3-in 3-in Oil Diesel 11 1.50 × 0.93 × 0.72 425 [937] None
Fig 602 Fig 602 engine [4.92 × 3.05 × 2.36]
Female Male
PMP-TDC 3-in 3-in Oil Diesel 39 3.70 × 0.85 × 1.53 2,000 [4,410] None
Fig 602 Fig 602 engine [12.14 × 2.79 × 5.02]
Female Male
PMP-TDW 3-in 3-in Oil Diesel 39 3.70 × 0.85 × 1.53 2,300 [5,070] None
Fig 602 Fig 602 engine [12.14 × 2.79 × 5.02]
Female Male
† Complies with European Pressure Equipment Directive 97/23
‡ Complies with ATEX directive or explosive atmospheres directive
§ National Association of Corrosion Engineers International

www.slb.com/welltesting
06-WT-041 September 2006
*Mark of Schlumberger
Copyright © 2006 Schlumberger. All rights reserved.
Produced by Schlumberger Marketing Communications

You might also like