You are on page 1of 1

Automatic Recirculation Valve Technical Data

Customer KSB Pumps Ltd.


Order: K11-0789.1 Datasheet:
SA.TD.037076 Rev.:2
Main Order TAG-No.: 5111063634, 5111063634
Reference no. IND-095-5094 Quantity: 2.00
Project: NSL Krishnaveni Sugars Ltd

Automatic Recirculation Valve type : TDM087UVW-CS


Valve inlet DN 2" PN 900lbs Code: ASME B16.5 - RF
Valve outlet DN 2" PN 900lbs Installation: Vertical
Bypass outlet DN 1" PN 900lbs Painting: Standard
Start-up DN PN Start-Up::
Mat.-/test certificates: EN 10204 / 3.1 IBR III C
Materials
Housing Internals Seals
A105 1.0460 SS; Cr>13% EPDM
Medium: Boiler Feed Water Operating Temp.: 105.00 °C
S.G.: 0,955 [kg/dm3] Design Temp.: 105.00 °C
Design Pressure:

Q100 = 27.40 m³/h H100 = 1000.00 m Suction pV 2.09 kg/cm^2


Qmax = 51.10 m³/h H0 = 1060.40 m Diff.-pressure pdiff 95.44 bar (Pdiff=P1-Pn)
QM = 13.50 m³/h HM = 1040.00 m Backpressure pN 4.09 Kv m = 1.4 m^3/h
kg/cm^2
QA = HA = Backpressure pA Kv a =
Notes:
Client: Cheema Boilers Limited
Pump Type: HDA 65/15
Indent No.: 34001910532
Qmax is pump runout flow
Pressure drop at rated conditions ~ 1 bar
Revision Date Description Name Signature
0 19.05.2011 prepared PUHL
2 01.09.2011 pressure drop added PUHL
1 04.08.2011 QM, HM revised PUHL

Q
H0 Operating range
P2 Tank
HM
H50 Duty
point Qmax
Head H in mF.S.

Qmin
H100
HQmax PN
Q
Bypass

QM 50 100 Pv
Flow Q in %
Pump

 
        !#"#$%'&(
) *+ ,'.-*/-01'2  345.67  88