You are on page 1of 3

NevonSolutions Pvt Ltd © All Rights Reserved

Time & Distance Chart for 99.9% Virus Deactivation

1. C72 Minimum Time Dosage Chart (At Mesh Center)


Time (Seconds) Minimum Dosage Maximum Dosage
1 9.1 J/m2 11.0 J/m2
5 45.5 J/m2 55 J/m2
10 91 J/m2 110 J/m2
15 136.5 J/m2 165 J/m2
20 182 J/m2 220 J/m2
25 227.5 J/m2 275 J/m2
30 273 J/m2 330 J/m2
35 318.5 J/m2 385 J/m2
40 384 J/m2 440 J/m2
45 409.5 J/m2 495 J/m2
50 455 J/m2 550 J/m2

https://www.ncbi.nlm.nih.gov/pubmed/25806411

N95 Masks Degrade 1.25% at 120 J/cm2 = 1200000 J/m2

Thus, N95 Masks can be Disinfected considerable number of times before degradation

Summary of UV Doses Needed to Deactivate Coronaviruses (Verifiable)

Microbe D90 dose (exposure) required Source

Coronavirus 7 J/m2 Walker 2007

Berne virus (Coronaviridae) 7 J/m2 Weiss 1986

Murine Coronavirus (MHV) 15 J/m2 Hirano 1978

Canine Coronavirus (CCV) 29 J/m2 Saknimit 1988

Murine Coronavirus (MHV) 29 J/m2 Saknimit 1988

SARS Coronavirus CoV-P9 40 J/m2 Duan 2003

Murine Coronavirus (MHV) 103 J/m2 Liu 2003

SARS Coronavirus (Hanoi) 134 J/m2 Kariwa 2004

SARS Coronavirus (Urbani) 241 J/m2 Darnell 2004

NevonSolutions Pvt Ltd © All Rights Reserved


Design Specifications

NevonSolutions Pvt Ltd © All Rights Reserved

You might also like