You are on page 1of 15

Rapid Sand Filter, Design Calculation, Spreadsheets

DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA


FILTER BED
Flow through filter QF 2000 L/s
7,200 m3/h
Filtration rate VF 5 m/h ( 5 - 10 )
Nos. bed Lama backwash total sehari
Jml. dibackwash serentak tiap rit Nbw 4 unit > 1 19.5 min @ 3 min < 1440 min
(1 x 24 hours per unit) (Nopr1/Nbw) x (tbw )
(Jml. rit) x (lama 1 rit backwash)
Jml. total (sebelum ada backwashing) Nopr1 26 Unit > 2 Paralel QF1 = QF / Nopr1 277 m3/h per unit
Jml. operasi sisa (tdk dibackwash) Nopr2 22 unit QF2 = QF / Nopr2 327 m3/h per unit
Dimensi bed
Luas sebuah bed abed 55.4 m2 < 60 abed = QF1 / VF
Rasio panjang dan lebar L/W 1.25 ( 1.25 - 1.33 )
abed 0.5
Lebar sebuah bed W 6.7 m W = N opr1 ditambah
rasio L/W
Kebesaran X ! 10 m ( 2.4 - 5 ) Verifikasi
Panjang sebuah bed L 12.5 m L = (W) x (rasio L/W)
13 m ( 3 - 6 ) Verifikasi N ditambah !
Bed depth H 3.4 m
Freeboard h1 0.3 m ( 0.4 - 0.6 )
Water depth h2 1.5 m ( 1.5 - 2.5 )
Media depth (pasir) h3 0.7 m ( 0.6 - 0.9 )
(kerikil) h4 0.4 m ( 0.4 - 0.6 )
Underdrained depth h5 0.5 m ( 0.45 - 0.6 )
Cek Filtration rate saat ada backwash
Debit per bed QF2 327 m3/h
Luas per bed abed 55 m2
Filtration rate VF 5.9 m/h ( 5 - 10 )

DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA


UNDERDRAIN, TROUGH DAN RESERVOIR PENCUCI

Debit backwash
Backwash rate Vbw 30 m/h ( 20 - 50 )
Debit per bed qbw 3,900 m /h 3
qbw = Vbw L B
Debit total Qbw 15,600 m /h3
Qbw = qbw Nbw
Underdrain sebuah bed (L x B)
Luas total orifice AO 0.2 % L x B ( 0.2 - 0.5 )
0.2600 m 2

Luas total lateral Al 2 x AO ( 2 - 4 )

0.5200 m2

Luas total manifold Am 2 x Al ( 2 - )

1.0400 m2 1 m =100 cm = 1000 mm


Orifice per bed dO 8 mm ( 6 - 12 )
5175.2 holes
5180 holes
Lateral per bed dl 60 mm ( 60 - 90 )
184.0 unit
186 unit
Manifold per bed dm 1151.0 mm 1 unit
1152 mm
Debit backwash per bed qbw 3900.0 m3/h
Kecepatan di lateral vl 2.08 m/s < 2.25 vl = (qbw / 3600) / Al
Kecepatan di manifold vm 1.04 m/s < 2.25 vm = (qbw / 3600) / Am
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
Jarak as ke as antar-orifice So 8 cm So = 7.5 cm untuk do = 6 mm
So = 20 cm untuk do = 12 mm

Dilobangi pd dasar lateral, sudut (30-60)o

Jarak as ke as antar-lateral Sl 15 cm ( 15.0 - 30.0 )

dl

dl
So
S
do do 1/2 So So 1/2 So
o
dm L
l

Trough per unit


Debit backwash per bed (boks filter) qbw 3,900 m /h
3 0.3
1.08 m3/s b
h2 0.10
Debit per trough qtr 0.09 m /s
3
1.73 b h 1
1.5
=
Jumlah ntr 12.7 unit ntr = qbw / qtr h1 0.30
=
~ 13 unit h3 = 0.90
Jarak antar trough < 2m
Jarak trough ke dinding < 1m muka pasir
Slope S 0 m/m (tdk.
terekspansi)
muka pasir
(tdk.
terekspansi)

DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA


Air Pencuci dan Reservoir
Debit backwash total (serentak) Qbw 15600 m3/h Qbw = qbw Nbw
Backwash period tbw 3 min ( 3 - 10 )
Volume reservoir pencuci VR 195 m3 VR = Vbw tbw Abed
2.7 % ( 0.1 - 0.5 ) ~ VR / Q F
Tekanan backwashing pada lateral/orifice p1 10 mwc ~ m < 1
Head loss (pasir, underdrain dan pipa) p2 4 mwc ( 2 - 5 ) Maksimum
Tekanan total (tinggi reservoir) P 14.0 mwc P = p1 + p2

1 Nbw tidak berpengaruh pada total kebutuhan air pencuci


1 Nbw makin sedikit maka akan makin kecil ukuran elevated reservoir untuk backwash, tapi frekuensi pemompaan makin sering.
Total kebutuhan air pencuci tetap, untuk mencuci seluruh Nopr1 dalam 1 hari

Satuan :
d = day, hari; h = hour, jam; min = minute, menit; s = second, detik
mwc = meter water column
1 atm = 1 kg/cm2 = 10 mwc

Referensi :
1. Terence J. McGhee, Water Supply and Sewerage, 1991
2. Harry S. Harbold, Sanitary Engineering Problems and Calculation for the Professional Engineer, 1979
3. B S N Raju, Water Supply and Wastewater Engineering, 1995
Cara pengoperasian/pengisian data :

Sheet ini dapat diisi data sesuai huruf/angka hijau. Huruf hijau bisa diisi angka. Angka hijau tidak boleh diisi huruf.
Selain huruf/angka hijau tidak dapat diganggu karena diprotek. Yah, dilihat sajalah. Isinya mengenai mekanisme desain secara tabelaris.
Yang penting, pilih dan isi kode satuan yang diinginkan, mulai dari 0, 1, 2 dan seterusnya. Nilainya diisi sesuai dengan satuan yang dipilih.
Tidak semua angka, baik input maupun kriteria harus dirubah, kecuali ada pertimbangan khusus dari anda. (Jngn tersinggung loh)

Achmad Mufid, hp. 083872524586, 081284051151; achmad_mufid@yahoo.com; masterlimbah.blogspot.com


STOKE'S LAW
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
Karakteristik media (Pasir Silika S iO2)
Effective size (EZ) ES 0.55 mm ( 0.45 - 0.55 )
Diameter geometric mean media (backwash) d 0.98 mm
Uniformity Coefficient (UC) UC 1.50 ( 1.20 - 1.70 )
Gravitasi spesifik g 9.81 m/s 2

Gravitasi spesifik media SS 2.50


Porisitas stratified bed yang mixed sized pe 0.45
Viskositas dinamik pada temperatur T Co
mT 0.890 Centipoise T = 25 oC
Viskositas kinematik pada temperatur T oC nT 0.898 Centistoke T = 25 oC
0.898 x 10-6 m2/s
Kecepatan pengendapan partikel media Mula-mula diasumsi :
g (Ss - 1) d 2
Re1 < 1; CD1 = 24/Re
Settling VS1 0.8815 m/s VS =
18 uT

VS1 d
Cek Stoke's Law Re1 966 - Re1 = Re >1, jadi dg Stoke's itu tdk cocok
uT

Langkah lanjutan di bawah ini bila Stoke's Law di atas tidak disarankan untuk dipakai
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
Koefisien Drag CD2 0.2994 - CD2 = 18,5/Re10,6 Re2 = 1 - 2000
(Transisi)
4 g (Ss - 1) d
Pengendapan terkoreksi 1 VS2 0.254 m/s VS2 = (rumus umum)
3 CD2

VS2 d
Re3 278.26 - Re3 =
uT

CD3 0.63 - CD3 = 18,5 / Re30,6

4 g (SS - 1) d
Pengendapan terkoreksi 2 VS3 0.1748 m/s VS3 =
3 CD3

Re4 191.57 - Fungsi Vs3


CD4 0.79 -
Pengendapan terkoreksi 3 VS4 0.1563 m/s
Re5 171.27 - Fungsi Vs4
CD5 0.85 -
Pengendapan terkoreksi 4 VS5 0.1511 m/s
Re6 165.61 - Fungsi Vs5
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
CD6 0.86 -
Pengendapan terkoreksi 5 (trial terakhir) VS6 0.1496 m/s OK, VS6 ~ VS5, kecepatan pengendapan final
Vs 8.98 m/min

Pengendapan alternatif lain (kecepatan terminal) Vs 8.25 m/min Vs = 10 (Uc Es)

Backwashing rate (Upflow velocity)


Pengendapan terpilih Vs 8.25 m/min Pilih salah satu dari Vs di atas
Fluidizasi minimal (backwashing) Vbw 0.23 m/min Vbw = Vs pe4.5 (tdk/belum/nyaris terekspansi)
13.62 m/h
Normal (backwashing) Vbw 0.86 m/min Vbw = Uc Es mT -1/3 (pasti terekspansi)
51.45 m/h D60 = Uc Es

Untuk desain backwashing rate tentunya diambil di antara fluidizasi minimal dan normal.
( 20 - 50 ) m/h

1 gal/(min.ft2) = 2.4448 m/h


Achmad Mufid, hp. 083872524586; achmad_mufid@yahoo.com; masterlimbah.blogspot.com
g pe3
Vbw21.2 = (SG - 1) d01,8
130 nT0.8 (1 - pe)0.8

0.001553
VISKOSITAS
VISKOSITAS ABSOLUT VISKOSITAS
TEMPERATUR
(DINAMIK), m KINEMATIK, n

[Centipoise] [Centistoke]
[oC] [10-2 g/(cm.s)] [10-2 cm2/s]
[10-3 kg/(m.s)] [10-6 m2/s]
[10-3 N.s/m2]
[10-3Pa.s]
0 1.7921 1.7923
1 1.7330 1.7332
2 1.6740 1.6741
3 1.6208 1.6208
4 1.5676 1.5676
5 1.5201 1.5201
6 1.4726 1.4726
7 1.4299 1.4300
8 1.3872 1.3874
9 1.3484 1.3487
10 1.3097 1.3101
11 1.2743 1.2748
12 1.2390 1.2396
13 1.2069 1.2076
14 1.1748 1.1756
15 1.1452 1.1462
16 1.1156 1.1168
17 1.0879 1.0893
18 1.0603 1.0618
19 1.0345 1.0361
20 1.0087 1.0105
21 0.9847 0.9867
22 0.9608 0.9629
23 0.9384 0.9407
24 0.9161 0.9186
25 0.8953 0.8980
26 0.8746 0.8774
27 0.8554 0.8584
28 0.8363 0.8394
29 0.8183 0.8216
30 0.8004 0.8039

m [kg/(m.s)]
n [m2/s] =
r [kg/m3]
Ref. : BSN Raju, WATER SUPPLY AND WASTEWATER ENGINEERING

Achmad Mufid, hp. 083872524586


Rapid Sand Filter, Design Calculation, Spreadsheets
DESKRIPSI SIMBOL VOLUME UNIT Notes / Criteria
FILTER BED
Flow through filter QF 2000 L/s
7,200 m3/h
Filtration rate VF 5 m/h ( 5 - 10 )
Nos. bed Backwashing time total per day
Nos. backwashing Nbw 2 unit > 1 39 min @ 3 min < 1440 min
(Nopr1/Nbw) x (tbw )
(Jml. rit) x (lama 1 rit backwash)
Nos. total Nopr1 26 Unit > 2 Paralel QF1 = QF / Nopr1 277 m3/h per unit
Nos. filtering Nopr2 24 unit QF2 = QF / Nopr2 300 m3/h per unit
Dimensi bed
Area per bed abed 55.4 m2 < 60 abed = QF1 / VF
Rasio L/W L/W 1.25 ( 1.25 - 1.33 )
abed 0.5
Width per bed W 6.66 m W = rasio L/W

6.7 m
Length per bed L 8.38 m L = (W) x (rasio L/W)
8.4 m
Bed depth H 3.6 m
Freeboard h1 0.4 m ( 0.4 - 0.6 )
Water depth h2 1.5 m ( 1.5 - 2.5 )
Media depth (pas h3 0.7 m ( 0.6 - 0.9 )
(kerikil) h4 0.5 m ( 0.4 - 0.6 )
Underdrained depth h5 0.5 m ( 0.45 - 0.6 )
Check Filtration rate during backwashing
Flow per bed QF2 300 m3/h
Area per bed abed 56.3 m2
Filtration rate VF 5.3 m/h ( 5 - 10 )

DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA


UNDERDRAIN, TROUGH, RESERVOIR or PUMP

Backwash flow
Backwash rate Vbw 30 m/h ( 20 - 50 )
Flow per bed qbw 1,688 m /h3
qbw = Vbw L B
Flow total Qbw 3,377 m /h 3
Qbw = qbw Nbw
Underdrain per bed (L x B)
Area total orifice AO 0.2 % L x B ( 0.2 - 0.5 )
0.1126 m 2

Area total lateral Al 2 x AO ( 2 - 4 )

0.2251 m2

Area total manifold Am 2 x Al ( 2 - )

0.4502 m2
Orifice per bed dO 8 mm ( 6 - 12 )
2240.4 holes
2242 holes
Lateral per bed dl 60 mm ( 60 - 90 )
79.7 unit
80 unit
Manifold per bed dm 757.3 mm 1 unit
758 mm
Flow backwash per bed qbw 1688.4 m3/h
Velocity (lateral) vl 2.08 m/s < 2.25 vl = (qbw / 3600) / Al
Velocity (manifold) vm 1.04 m/s < 2.25 vm = (qbw / 3600) / Am
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
Distance orifice c/c So 8 cm So = 7.5 cm untuk do = 6 mm
So = 20 cm untuk do = 12 mm

Dilobangi pd dasar lateral, sudut (30-60)o

Distance lateral c/c Sl 15 cm ( 15.0 - 30.0 )

dl

dl
So So
S
do do 1/2 So So So 1/2 So
o
dm Ll

Trough
Flow backwash per bed (boks filter) qbw 1,688 m3/h 0.30 m
0.47 m3/s b 0.10 m
h2
Flow per trough qtr 0.09 m3/s 1.73 b h11.5
Nos. ntr 5.5 unit ntr = qbw / qtr h1 0.30 m
~ 6.0 unit
Distance trough c/c 2.0 m ( 1.5 - 2.5 ) h3 0.60 m
Distance trough to the near wall < 1m
Slope S 0 m/m level sand top
(un-expanded)
DESKRIPSI SIMBOL VOLUME UNIT CATATAN/KRITERIA
Air Pencuci dan Reservoir
Debit backwash total (serentak) Qbw 3377 m3/h Qbw = qbw Nbw
Backwash period tbw 3 min ( 3 - 10 )
Volume reservoir pencuci VR 84.4 m3 VR = Vbw tbw Abed
1.2 % ( 1 - 5 ) ~ VR / Q F
Tekanan backwashing pada lateral/orifice p1 10 mwc ~ m < 1
Head loss (pasir, underdrain dan pipa) p2 4 mwc ( 2 - 5 )
Tekanan total (tinggi reservoir) P 14.0 mwc P = p1 + p2

1 Nbw tidak berpengaruh pada total kebutuhan air pencuci


1 Nbw makin sedikit maka akan makin kecil ukuran elevated reservoir untuk backwash, tapi frekuensi pemompaan makin sering.
Total kebutuhan air pencuci tetap, untuk mencuci seluruh Nopr1 dalam 1 hari
1 Verifikasi = pembulatan

Satuan :
d = day, hari; h = hour, jam; min = minute, menit; s = second, detik
mwc = meter water column
1 atm = 1 kg/cm2 = 10 mwc
1 m =100 cm = 1000 mm

Referensi :
1. Terence J. McGhee, Water Supply and Sewerage, 1991
2. Harry S. Harbold, Sanitary Engineering Problems and Calculation for the Professional Engineer, 1979
3. B S N Raju, Water Supply and Wastewater Engineering, 1995
Cara pengoperasian/pengisian data :

Sheet ini dapat diisi data sesuai huruf/angka hijau. Huruf hijau bisa diisi angka. Angka hijau tidak boleh diisi huruf.
Selain huruf/angka hijau tidak dapat diganggu karena diprotek. Yah, dilihat sajalah. Isinya mengenai mekanisme desain secara tabelaris.
Yang penting, pilih dan isi kode satuan yang diinginkan, mulai dari 0, 1, 2 dan seterusnya. Nilainya diisi sesuai dengan satuan yang dipilih.
Tidak semua angka, baik input maupun kriteria harus dirubah, kecuali ada pertimbangan khusus dari anda. (Jngn tersinggung loh)

Achmad Mufid, hp. 083872524586, 081284051151; achmad_mufid@yahoo.com; masterlimbah.blogspot.com

You might also like