Professional Documents
Culture Documents
NSGAFÖU, 1.8/3kV
according to VDE 0250 Part 602
Application
Special rubber insulated single core used in rail cars and buses, in dry rooms, pipes and closed installation ducts, for fixed installation or
flexible installation. Protected against accidental earthing for low voltage plant up to 1000V.
Construction
Conductor Bare stranded conductor, fine wire to IEC 60228 Cl.5
Inner sheath EPR (Ethylene Propylene Rubber)
Outer sheath PCP Neoprene Rubber, outer sheath black colour
Flame retardant, abrasion & oil resistant
Technical Data
Nominal voltage 1800/3000 V
Test voltage 6 kV
Temperature range Flexing: -25°C to +80°C Fixed: -40°C to +80°C
Min. bending radius Approx. 5 x cable Ø
Specifications
No of cores x Approx. Approx.
cross sec. outer diameter cable weight
mm² mm Kg/km
1 x 1.5 6.30 53
1 x 2.0 6.70 66
1 x 4.0 7.40 83
1 x 6.0 7.90 105
1 x 10 9.50 165
1 x 16 10.50 225
1 x 25 12.80 350
1 x 35 14.10 450
1 x 50 15.90 615
1 x 70 17.80 815
1 x 95 20.10 1,060
1 x 120 22.00 1,340
1 x 150 24.00 1,575
1 x 185 26.30 1,900