Sepam 100 is a group of modules that may description


be used:
■ individually to perform a function, The front of Sepam 100 RT includes:
■ in combination with Sepam 1000 ■ 7 indicator lamps:
or 2000. ■ device "on" indicator,
■ "In3" to "In5" indicators: electrically
Each module has been designed to perform latched indicators which store the activated
a complete function. It includes all the status of each of the 3 'tripping" inputs,
elements required, such as: ■ "In1" and "In2" indicators: electrically
■ tripping output relays,
latched indicators which store the activated
■ annunciation,
status of the 2 "alarm" inputs and indicate
■ connections.
the status of the "alarm 1" and "alarm 2"
output relays,
applications ■ "out" indicators: latching indicator which
Sepam 100 RT shows switching of the "tripping" output
Specially designed for transformer relay.
protection applications, offering a ■ a "reset" pushbutton: for acknowledgment
combination of DGPT2 or Buchholz plus of the relay outputs and associated display
thermostat information. when the inputs return to their normal
position.
While activated, this pushbutton may be
advantages used for a lamp test of the indicators on the
Simple to use: front of the device .
■ three "tripping" inputs, The back of Sepam 100 RT includes:
■ two "alarm" inputs with the possibility of ■ input/output connectors:
individual "tripping" input parameter setting, ■ a 21-pin connector for the "alarm" inputs
■ electrically latched inputs, and outputs,
■ a "tripping" output with high breaking ■ an 8-pin connector for the "tripping"
capacity linked with two other outputs: output and for the power supply,
"inhibit closing" and "annunciation", ■ a 4-pin connector for the "power ON"
■ two "alarm signal" outputs linked with the output.
Sepam 100 RT. two "alarm" inputs,
■ local or remote acknowledgment,
Sepam 100 RT has:
■ 5 common-point logic inputs, named "In1"
■ integrated "lamp test".
to "In5" ,
on ■ an isolated remote "reset" input,
Clear information
■ a 3-contact "tripping" output relay (2
■ display of "tripping" input and output
in1
status on the front of the device. normally open contacts and 1 normally
in2 closed contact),
in3 Dependable operation ■ 2 "alarm" relays (changeover contacts),
■ high level of immunity to electromagnetic ■ a "power ON" relay (1 normally open
in4
disturbances: Sepam 100 RT is designed contact and 1 normally closed contact).
in5
to operate safely in the highly disturbed Sepam 100 RT operates in 3 ranges of
electromagnetic environments of HT supply voltage (please specify when
out
substations. ordering):
■ 24-30 V DC ±20%,
■ 48-125 V DC ±20%,
■ 220-250 V DC -20% +10%.

reset

sepam 100
S01 RT

Front of device with display and control


of acknowledgement/lamp test.
.

2
parameter setting Access to and identification of
microswitches SA-1 and SA-2.
The parameters of the 2 "alarm" inputs
made be set so as to make them "tripping"
inputs.
"Alarm" inputs In1 and In2 may be set
individually as "tripping" inputs. SA-2
The choice is made via two microswitches SA-1
that are accessible on the left-hand side of
Sepam 100 RT.
Access to the microswitches is closed off
by a removable plastic cover.
The plastic cover should be replaced after
the setting has been made. Parameter setting

"Alarm" position.
Move the microswitch tab to the left.

"Tripping" position
Move the microswitch tab to the right.

functional and connection


diagram
0 A
3
4 alarm 1
O4
2 output
10 0 A 1
com
7
11 8 alarm 2
In1 O5
6 output
5
S
SA - 1 1
R In1
12 "alarm"
In2
inputs

S
SA - 2 1
R In2
13
In3

S
1
R In3
14
In4

S "tripping"
1 inputs
R In4
15
In5

S 1
R In5
21
1
reset out
20
1
1 A
8
O1
reset PB 7
6 tripping
O2 outputs
5
4
1A O3
1 3
+
aux. on
sup. 2 1 B
- 4
3 power
O6 on
2
1 output

3
connection

Sepam 100 RT 0 A 21-pin CCA 621 connector ("alarm" 0A


inputs and outputs), screw terminal wiring
1 A 8-pin CCA 608 connector (power
with wires 0.6 to 2.5 mm2 max., each
supply and "tripping" outputs), screw AS RT
terminal capable of receiving two 1.5 mm2
terminal wiring with wires 0.6 to 2.5 mm2 1A
wires. A
max. Each terminal capable of receiving
two 1.5 mm2 wires. 8 21

1 B CCA 604 connector (power ON), 7 20


screw terminal wiring for wires 0.6 to 2.5
6 19
mm2 max. Each terminal capable of
receiving two 1.5 mm2 wires. 5 18

4 17

3 16

1A 8 2 – 15
O1 0 A 21
7 tripping 20 reset 1 + 14

O2 6 19 A 13

5 annunciation 18 12
O3 4 17

220-240VAC
inhibit 11
3 closing 16 inputs
10
2 15

220-240VAC
– aux In5
1 14 9
+ supply In4

220-250VDC
100-127VAC
13 8
In3

100-127VAC
12 P
In2 7
11 In1 1B
6

48-125VDC
10

220-250VDC
common
9 B 5

8 4 4
05

48-125VDC
7

24-30VDC
alarm 2 3 3
6 output
O6 2 2
5

24-30VDC
1B 4 1 1
4
3 04 3
power on alarm 1 B A
2 2 output
output
1 1

Terminal identification
earthing terminal Each terminal is identified by 3 characters.

1 A 4

board slot number (0 to 1)

connector identification letter


(A or B)
connector terminal number

4
-C +C SEPAM 100 RT
Example of input wiring
remote reset 0 A 21
(transformer protection) reset
0 A 20

0 A 15 In 5
thermostat (tripping) 0 A 14 In 4
buchholz (tripping) 0 A 13 In 3
thermostat (alarm) 0 A 12 In 2
buchholz (alarm) 0 A 11 In 1
0 A 10 Com

1 A 1
+
1 A 2 power
-

Example of circuit breaker control +C


output contact wiring
on off

1A3 1A7 1A5

Sepam 100 RT 03 01 02

1A4 1A8 1A6

M
TRIP
CLOSE

–C

5
characteristics

electrical characteristics
logic inputs
24/30 Vdc 48/127 Vdc 220/250 Vdc
power consumption 10 mA 5 mA 4 mA
typical filtering time 5 ms
logic outputs (relays)
breaking capacity (1) 24/30 Vdc 48 Vdc 127 Vdc 220/250 Vdc
contact O1 7A 4A 0.7 A 0.3 A
contacts O2 to O5 3.4 A 2A 0.3 A 0.15 A
making capacity 8A
permissible steady state current 8A
number of operations under full load 10 000
response time typical 15 ms
(inputs to outputs) max. 25 ms
power supply
range typical maxi inrush current
consumption consumption
24/30 Vdc ± 20% 2.5 W 6,5 W < 10 A during 10 ms
48/127 Vdc ± 20% 3.5 W 7.5 W < 10 A during 10 ms
220/250 Vdc - 20%, + 10% 4W 9W < 10 A during 10 ms

environmental characteristics
climatic
operation IEC 68-2 -10°C to +70°C
storage IEC 68-2 -25°C to +70°C
damp heat IEC 68-2 95% to 40°C
mechanical
degree of protection IEC 529 IP 51 on front
vibrations IEC -255-21-1 class I
shocks IEC 255-21-2 class I
seismic tests IEC 255-21-3 class I
fire NFC 20455 glow wire
dielectric
power frequency IEC 255-4(1) 2 kV - 1 min.
1.2/50 µs impulse wave resistance IEC 255-4 5 kV
electromagnetic
radiation IEC 255-22-3 class x 30 V/m
electrostatic discharge IEC 255-22-2 class III
damped 1 MHz wave IEC 255-22-1 class III
5 ns fast transients IEC 255-22-4 class IV
(1)
published in 1976 and amended in 1979.
“ ” marking on our product guarantees their conformity to European directives.

6
installation

dimensions and weight Sepam 100


mounting latch
cut-out

222 201 202

A
86 max
20 175

88 84 max

e = 3 mm max

weight: 2 kg. mounting details A

7
Ordering information

Sepam 100 S01 RT

quantity: ...................................................................................................
auxiliary power supply: 24 to 30 Vdc .............................................................
48 to 125 Vdc ...........................................................
220 to 250 Vdc .........................................................

Schneider Electric SA postale address As standards, specifications and designs change from This document has been
F-38050 Grenoble cedex 9 time to time, please ask for confirmation of the information printed on ecological paper.
tel: (33) 04 76 57 60 60 given in this publication.
telex: merge 320842 F

Publishing: Schneider Electric SA


AC0400/2EN Design, production: Idra
ART.62383 Printing: 11 / 1996

You might also like