You are on page 1of 5

www.hilti.in Profis Anchor 2.8.

0
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/29/2018
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HVZ M16x125
Dynamic set or any suitable annular gap filling solution
Effective embedment depth: hef = 125 mm, hnom = 145 mm
Material: 8.8
Evaluation Service Report: Z-21.3-1692
Issued I Valid: 10/14/2016 | 4/14/2020
Proof: Design method DIBTDYN; dynamic load type:pulsating
Number of load cycles: > 1000000
Stand-off installation: bending not allowed; eb = 0 mm (no stand-off); t = 13 mm
Anchor plate: lx x ly x t = 250 mm x 250 mm x 13 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: cracked concrete, C20/25, fc,cube = 25.00 N/mm2; h = 230 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
.

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/29/2018
E-Mail:

2 Load case/Resulting anchor forces y


Load case: 34, relevant loadcase

Anchor reactions [kN]


Tension force: (+Tension, -Compression)

Anchor forces steel


Anchor Tension force Shear force Shear force x Shear force y
1 15.260 0.000 0.000 0.000
1 x
Anchor forces concrete direction 1 Tension
Anchor Tension force Shear force Shear force x Shear force y
1 15.260 0.000 0.000 0.000

Anchor forces concrete direction 2


Anchor Tension force Shear force Shear force x Shear force y
1 15.260 0.000 0.000 0.000

max. concrete compressive strain: - [‰]


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 15.260 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid baseplate.

Safety factors
gF,N gF,V
1.000 1.000

3 Tension load
Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 15.260 19.259 801) OK
Pullout Strength* 15.260 22.222 69 OK
Concrete Breakout Strength** 15.260 22.361 69 OK
Splitting failure** N/A N/A N/A N/A
1
(gF,N · DNEd/DNRd)a; * anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength (relevant loadcase: 34)


DNRk,s [kN] gM,s DNRd,s [kN] DNEd [kN] a
26.000 1.350 19.259 15.260 1.000

3.2 Pullout Strength (relevant loadcase: 34)


DNRk,p [kN] yc gM,p DNRd,p [kN] DNEd [kN]
30.000 1.000 1.350 22.222 15.260

3.3 Concrete Breakout Strength (relevant loadcase: 34)


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm]
140,625 140,625 188 375
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1
0 1.000 0 1.000 1.000 1.000 7.2
N0Rk,c [kN] NRk,c [kN] hfat gM,c DNRd,c [kN] DNEd [kN]
50.312 50.312 0.600 1.350 22.361 15.260

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/29/2018
E-Mail:

4 Shear load
Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* N/A N/A N/A N/A
Pryout Strength* N/A N/A N/A N/A
Concrete edge failure in direction ** N/A N/A N/A N/A
Concrete edge failure parallel in direction ** N/A N/A N/A N/A
1 a
(gF,V · DVEd/DVRd) ; * anchor having the highest loading **anchor group (relevant anchors)

5 Combined tension and shear loads


Steel
bN bV Utilization bN,V [%] Status
Load case 34 0.792 - 80 OK

concrete
bN,c bV,c+ bV,c- bV,cp Utilization bN,V [%] Status
Load case 34 0.682 - - - 57 OK
bNV = bN + bV
1.5 1.5
bN,c + (bV,c+ + bV,c- + bV,cp) ≤ 1.0

6 Loadcases - combinations
Loadcase No. Static Loads Dynamic loads
N Vx Vy Mz Mx My
34 + + 0 0 0 0 0

7 Displacements

In the cases of single-anchor and multiple-anchor fastenings, max. displacement of 1 mm must be expected over the entire range of use under
fatigue-relevant action (pure tensile and shear loading).

8 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This
means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate
thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption
is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for
plausibility! 
• To install the anchor correctly the HILTI Dynamic Set is recommended
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software considers
that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can be

achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
• The anchor resistances used for this design are ONLY valid if the Seismic set will be installed on the jobsite as per IFU when the Seismic washer
was selected.
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/29/2018
E-Mail:

9 Installation data
Anchor plate, steel: - Anchor type and diameter: HVZ M16x125
Profile: no profile Installation torque: 0.090 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 13 mm Hole depth in the base material: 145 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 190 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

9.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • HVA square drive shafts
• Properly sized drill bit • Hilti seismic filling set
• Dynamic set
• Torque wrench
y

125 125

125

125

1 x
125

125

125 125

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 0 0 190 190 190 190

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/29/2018
E-Mail:

10 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan